Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "fracture analysis" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Fixation of distal fibular fractures: A biomechanical study of plate fixation techniques
Autorzy:
Marvan, J.
Horak, Z.
Vilimek, M.
Horny, L.
Kachlik, D.
Baca, W.
Powiązania:
https://bibliotekanauki.pl/articles/306556.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
analiza FEM
osteosynteza
złamanie kości
fibular fracture
finite element analysis
osteosynthesis
fracture fixation
fibula
Opis:
Ankle fractures are complex injuries with variable prognoses that depend upon many factors. The aim of the treatment is to restore the ankle joint biomechanical stability with maximum range of motion. Most ankle fractures are fibular fractures, which have a typical oblique fracture line in the distal fibula located in the area of the tibiofibular syndesmosis. The aim of this study was to simulate numerically several fixation techniques of the distal fibular fractures, evaluate their stability, determine their impact on surrounding tissue load, and correlate the results to clinical treatment experience. The following three models of fibular fracture fixation were used: (a) plate fixation with three screws attached above/below and lag screws, (b) plate fixation with two screws attached above/below and lag screws, and (c) three lag screws only. All three fracture fixation models were analyzed according to their use in both healthy physiological bone and osteoporotic bone tissue. Based on the results of Finite Element Analysis for these simulations, we found that the most appropriate fixation method for Weber-B1 fibular fractures was an unlocked plate fixation using six screws and lag screws, both in patients with physiological and osteoporotic bone tissue. Conversely, the least appropriate fixation method was an unlocked plate fixation with four screws and lag screws. Although this fixation method reduces the stress on patients during surgery, it greatly increased loading on the bone and, thus, the risk of fixation failure. The final fixation model with three lag screws only was found to be appropriate only for very limited indications.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 1; 33-39
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biomechanical comparison of a transiliac internal fixator and two iliosacral screws in transforaminal sacral fractures: a finite element analysis
Autorzy:
Salasek, M.
Jansova, M.
Křen, J.
Pavelka, T.
Weisova, D.
Powiązania:
https://bibliotekanauki.pl/articles/306399.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
analiza MES
stabilizator
biomechanika
finite element analysis
transiliac internal fixator
iliosacral screw
pelvic ring
transforaminal fracture
Opis:
Purpose: Vertically unstable sacral transforaminal fractures can be stabilized with a transiliac internal fixator (TIFI) or two iliosacral screws (IS). This study was designed to compare stiffness between TIFI and IS. Methods: Using CT images finite element model of the pelvis was developed. Denis II type fracture was simulated and fixed either with TIFI or two IS. The sacral base was loaded vertically (250–500 N), displacement magnitudes on medial and lateral fracture surface and the maximum bone stress were calculated. The intact pelvis was used as a reference. Stiffness was determined by linear regression of load and displacement, computed stiffness ratio %. The von Mises stress was expressed as % ratio, evaluation of colour mapping was made. Results: The mean stiffness ratio medially in TIFI was 75.22%, in IS 46.54% ( p = 0.00005), laterally in TIFI 57.88%, in IS 44.74% ( p = 0.03996). The von Mises stress ratio of TIFI was 139.27%, of IS 565.35% ( p < 0.00001). Conclusions: Significantly higher stiffness and lower stress were found in TIFI model. TIFI provides a lower risk of over-compression of the fracture line in comparison with IS. TIFI thus exhibits superiority for fixation of transforaminal fractures, particularly with comminutive zone.
Źródło:
Acta of Bioengineering and Biomechanics; 2015, 17, 1; 39-49
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Finite element analysis of mini-plate stabilization of human mandible angle fracture – a comparative study
Autorzy:
Wądołowski, Piotr
Krzesiński, Grzegorz
Gutowski, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/27324127.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
finite element analysis
maxillofacial surgery
mandibular angle fracture
miniplate osteosynthesis
contact mechanics
analiza elementów skończonych
chirurgia szczękowo-twarzowa
złamanie kąta żuchwy
osteosynteza minipłytkowa
mechanika kontaktowa
Opis:
Purpose: The purpose of this study was to analyze three patterns of mandible angle fracture treatment by means of the finite element analysis. Methods: Investigation has been based on the mandible geometry reconstructed with use of hospitalized patient CT data. The KLS Martin mini-plates with corresponding screws were used to establish proper fracture stabilization. Models were run assuming isotropic and elasto-plastic material properties of connecting devices and cortical bone. The main masticatory muscles and artificial temporomandibular joint have been incorporated to assure mandible physiological movement. The gage loading has been applied in three different locations to cover wider range of possible mastication loading cases during daily routine. A different contact conditions have been applied to the fracture plane to simulate both load bearing and sharing behaviors. Prepared FEM models reflect the most frequently used surgery’s approaches to mandible angle fracture treatment. A specific nomenclature has been introduced to describe particular model. The tension plate, with one connecting mini-plate, two-point fixation and combined fixation, both using two mini-plates respectively. Results: Performed analysis allowed for a detailed estimation of the mini-plate connection response under the applied gauge loading. The equivalent stress within the mini-plates and surrounding cortical bone have been compared between all models. Regarding the fracture plane, the contact status and pressure have been considered. Conclusions: The combined fixation model, acting as a biplanar fastener system, presents the highest flexibility and connection efficiency.
Źródło:
Acta of Bioengineering and Biomechanics; 2020, 22, 3; 105--116
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies