Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Postural Stability Test" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Postural stability in Parkinson’s disease patients
Autorzy:
Wilczyński, J.
Pedrycz, A.
Zieliński, E.
Ambroży, T.
Mucha, D.
Powiązania:
https://bibliotekanauki.pl/articles/306998.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
stabilność posturalna
choroba Parkinsona
test stabilności
postural stability
Parkinson's disease
Postural Stability Test
Opis:
Purpose: The aim of the study was to analyze postural stability in Parkinson's disease patients. A total of 32 subjects were tested, including 26 (81.25%) women and 6 (18.75%) men. These were patients with advanced, idiopathic Parkinson’s disease. The disease duration was over 5 years. Methods: The study was conducted in the Posturology Laboratory at the Department of Medicine and Health Sciences, Jan Kochanowski University in Kielce (Poland). The Biodex Balance System was used for evaluation of postural stability. Postural Stability Testing was performed with both feet positioned on a stable surface with the eyes open. Results: The Overall Stability Index in the whole group was 0.5°. The higher Overall Stability Index in women is indicative of slightly worse postural stability compared to men, although in both groups, it was within norms (Z = 2.0545, p = 0.0399). Anterior-Posterior Overall Stability Index (A/P) was an average of 0.35°. The Medial-Lateral Overall Stability Index (M/L) was an average of 0.27°. Both women and men were observed to have higher postural sway in the sagittal plane than the frontal plane. The vast majority of the subjects maintained in Zone A during testing (99.94%), and was slightly bent backwards to the right and in Quadrant IV (61.53%). Conclusions: Regular control of postural stability in Parkinson's disease patients is significant due to the risk of falls.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 4; 135-141
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the accuracy of the postural stability measurement with the Y-Balance Test based on the levels of the biomechanical parameters
Autorzy:
Walaszek, R.
Chwała, W.
Walaszek, K.
Burdacki, M.
Błaszczuk, J.
Powiązania:
https://bibliotekanauki.pl/articles/306519.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
biomechanika
staw kolanowy
stabilność postawy
testy
biomechanics
motor control
postural stability
Y-Balance Test
structure test
Opis:
The testing of dynamic balance involves tests that assess the muscle control of spatial changes of the position of the centre of gravity over the base of support. The purpose of this work was to determine the structure of the Y-balance test and its accuracy based on the measurements of strength performance of the muscles acting on the knee joint, as well as the flexibility and balance in boys aged 14 years. Methods: The study included 43 schoolboys regularly participating in physical education lessons. The examination of postural stability was conducted with the use of the Y-balance test. The measurements of muscle strength and of resistance to fatigue of the extensors and flexors of knee joints in isometric contraction were performed on a measurement stand in a standard position with the use of tensometric sensors. The measurement of mobility range of the lower extremity joints was performed according to the SFTR. The examination of balance was performed with the use of the modified ‘Flamingo balance test’. Results: The factor structure of the Y-balance test results for the left and right lower extremities is similar and includes five principal independent factors that characterise the structure of analysed variables. They explain 76% and 74% of communality in total for the left and the right extremity, respectively. Conclusions: The extracted factor structure points to a hybrid structure of the Y-balance test and shows its accuracy in the measurements of the lower limb joint mobility and strength performance of knee joint extensors.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 2; 121-128
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The assessment of the relationships between body posture indices and the Y-Balance Test results in the adolescents
Autorzy:
Walaszek, R.
Chwała, W.
Walaszek, K.
Burdacki, M.
Powiązania:
https://bibliotekanauki.pl/articles/306499.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
postawa ciała
metoda fotogrametryczna
stabilność postawy
test
równowaga
body posture
photogrammetric method
postural stability
Y-Balance Test
Opis:
The purpose of this work was to assess the differences of the values of body posture indices, measured with the Moire’s method, between girls and boys aged 13 and the relationships of these values with the results of the Y-Balance Test. Methods: The study involved a group of healthy volunteers attending junior high schools in Cracow. The group consisted of 20 girls and 35 boys. Basic somatic parameters were measured within this work: body height and weight. Body posture was assessed according to the general methodology of the Moire’s technique and 14 body posture indices were obtained as a result: 6 in the sagittal plane, 1 in the axial plane and 7 in the coronal plane. Postural stability was assessed with the Y-Balance Test (YBT). Results: The studied girls and boys had practically the same body posture – statistical differences were found only in 3 out of 14 assessed indices measured with the Moire’s technique. Scoliosis was found in as many as 51% of the subjects, however, mean values of deviations from the C7-S1 line were not large. Conclusions: In the group of girls, the set of blades (below – above) was statistically significantly correlated with the global YBT result for the right inferior extremity, and in the group of boys – the set of the waist triangles (below – above) was statistically significantly correlated with the global YBT results for the right and left inferior extremities.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 2; 149-157
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Absolute and relative reliability of several measures of static postural stability calculated using a GYKO inertial sensor system
Autorzy:
Jaworski, Janusz
Ambroży, Tadeusz
Lech, Grzegorz
Spieszny, Michał
Bujas, Przemysław
Żak, Michał
Chwała, Wiesław
Powiązania:
https://bibliotekanauki.pl/articles/27324151.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
balance
postural stability
accelerometer
test-retest reliability
intraclass correlation coefficient
balans
stabilność postawy
akcelerometr
niezawodność testu-retestu
współczynnik korelacji wewnątrzklasowej
Opis:
The aim of this study was to analyse absolute and relative reliability of a number of postural static stability measures obtained from a GYKO inertial sensor system in young adults. Methods: The study examined 29 healthy non-athlete young adults. A test was performed for 30 s while standing on one foot, without moving, with eyes open and arms relaxed along the sides of the body. The examinations were performed twice, with a one-week interval. Relative reliability was measured using the intraclass correlation coefficient (ICC) and the 95% confidence interval (95% CI), whereas the absolute reliability was evaluated based on the standard error of measurement (SEM) and the minimal detectable change (MDC). Results: The results of this study showed moderate to good relative reliability scores for all the postural stability measures, with ICC values ranging from 0.62 to 0.70. For most of the analysed variables, SEM% ranged from ca. 10 to 14%. Relatively high SEM% values were obtained only for two variables (Area, Convex Hull Area). Conclusions: The low costs of GYKO inertial sensor systems, the fast and easy installation, the mobility and high reliability of the measurement of postural stability show that it can be effective alternative to stabilographic platforms.
Źródło:
Acta of Bioengineering and Biomechanics; 2020, 22, 2; 93--99
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies