Tytuł:
Technical aspects of prosthetically guided maxillofacial surgery of the mandible : A pilot test study
Autorzy:
Ciocca, L.
Mazzoni, S.
Marchetti, C.
Scotti, R.
Powiązania:
https://bibliotekanauki.pl/articles/306279.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
bone plate
CAD
CAM
maxillofacial prosthesis
zespolenie
biomechanika
Opis:
A test of the accuracy in transferring the virtual data into the surgical environment was carried out. Differences between the virtually planned and the actual position during surgery of the rapid prototyped guides and the bone plates were investigated. The accuracy of the method was evaluated in terms of the precision of cuts in the mandible, the final positions of the rami and condyles, and the sectioning precision of the fibula. The guide position presented a mean value dislocation of 0.6 mm in the right side and of 4.1 mm in the left side; the cut line of the mandible presented an angular deviation of 2.9° (right) and of 17.5° (left). The right condyle was positioned 2.5 ± 0.05 mm more medial than native position, and the left condyle 5.2 ± 0.05 mm medial. The total length was 0.3 ± 0.05 mm short of the virtually projected length at the inferior margin of the mandible and 1.9 ± 0.05 mm longer than projected at the superior margin. The Prosthetically Guided Maxillofacial Surgery (PGMS) is a viable way to improve the precision of mandibular reconstruction using a fibula free flap.
Źródło:
Acta of Bioengineering and Biomechanics; 2014, 16, 2; 21-29
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microstructural and micromechanical tests of titanium biomaterials intended for prosthetic reconstructions
Autorzy:
Ryniewicz, A. M.
Bojko, Ł.
Ryniewicz, W. I.
Powiązania:
https://bibliotekanauki.pl/articles/307469.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
CAD/CAM
protetyka stomatologiczna
DMLS
mikrostruktura
mikrotwardość
tytan
stop tytanu
CAD/CAM system
dental prosthetics
direct metal laser sintering
microstructure
microhardness
titanium
titanium alloy
Opis:
Purpose: The aim of the present paper was a question of structural identification and evaluation of strength parameters of Titanium (Ticp – grade 2) and its alloy (Ti6Al4V) which are used to serve as a base for those permanent prosthetic supplements which are later manufactured employing CAD/CAM systems. Methods: Microstructural tests of Ticp and Ti6Al4V were conducted using an optical microscope as well as a scanning microscope. Hardness was measured with the Vickers method. Micromechanical properties of samples: microhardness and Young’s modulus value, were measured with the Oliver and Pharr method. Results: Based on studies using optical microscopy it was observed that the Ticp from the milling technology had a single phase, granular microstructure. The Ti64 alloy had a two-phase, fine-grained microstructure with an acicular-lamellar character. The results of scanning tests show that titanium Ticp had a single phase structure. On its grain there was visible acicular martensite. The structure of the two phase Ti64 alloy consists of a β matrix as well as released α phase deposits in the shape of extended needles. Micromechanical tests demonstrated that the alloy of Ti64 in both methods showed twice as high the microhardness as Ticp. In studies of Young’s modulus of Ti64 alloy DMLS technology have lower value than titanium milling technology. Conclusions: According to the results obtained, the following conclusion has been drawn: when strength aspect is discussed, the DMLS method is a preferred one in manufacturing load structures in dentistry and may be an alternate way for the CAD/CAM system used in decrement processing.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 1; 121-127
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bond strength of modern self-adhesive resin cements to human dentin and different CAD/CAM ceramics
Autorzy:
Małysa, Andrzej
Weżgowiec, Joanna
Danel, Dariusz
Boening, Klaus
Walczak, Katarzyna
Więckiewicz, Mieszko
Powiązania:
https://bibliotekanauki.pl/articles/27324142.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
shear bond strength
self-adhesive resin cement
dentin
CAD/CAM ceramic
dental material
adhesion
wytrzymałość wiązania na ścinanie
samoadhezyjny cement na bazie żywicy
zębina
Ceramika CAD/CAM
materiał dentystyczny
przyczepność
Opis:
The aim of the study was to evaluate the shear bond strength of CAD/CAM ceramics to dentin after cementation with conventional or self-adhesive resin cements. Methods: Three self-adhesive, self-etching cements (Panavia SA, RelyX U200, Maxcem Elite), and one conventional cement (Panavia V5), were selected to lute three CAD/CAM ceramics (IPS Empress CAD, IPS e.max CAD, IPS e.max ZirCAD) onto the dentin. The bond strength was evaluated using a shear strength test according to the PN-EN ISO 29022:2013-10. Evaluation of the differences was performed using the Statistica software. Failure modes were analyzed using a light microscope. Results: All the studied cements differed (regardless of the ceramic type) in the bond strength. The highest bond strength was observed in Panavia V5, lower – in RelyX U200 and Panavia SA, and the lowest – in Maxcem. For IPS e.max ZirCAD, it was observed that compared to Panavia V5, the other cements were characterized by a significantly higher bond strength. For the IPS Empress CAD and the IPS e.max CAD, Panavia V5 displayed the highest bond strength. For all the studied self-adhesive cements, the failure of adhesion between the cement and dentin was predominant mode. Conclusions: Significant differences were found in the shear bond strengths of the CAD/CAM ceramics luted to dentin using tested self-adhesive and conventional cements. The bond strength depended on the combination of ceramic and cement. The IPS e.max ZirCAD had the highest bond strength to dentin after cementation with RelyX U200, while the IPS Empress CAD and IPS e.max CAD – with Panavia V5.
Źródło:
Acta of Bioengineering and Biomechanics; 2020, 22, 2; 25--34
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the effectiveness of training on a machine with a variable-cam
Autorzy:
Urbanik, C.
Staniszewski, M.
Mastalerz, A.
Karczewska, M.
Lutosławska, G.
Iwańska, D.
Madej, A.
Ostrowska, E.
Gwarek, L.
Tkaczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/307428.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
resistance training
elbow flexors
variable-cam
creatine kinase
trening
łokieć
mięśnie
kreatyna
kinaza
Opis:
The aim of the study was to assess the effectiveness of the training of elbow flexors through the use of 2 machines, one of which was equipped with a disc plate of constant radius, the other one with a variable-cam having a radius adjustable to muscle strength. The experiment included 45 men divided into 3 equal groups: training group A (variable-cam), training group B (circle), and control group C. The training lasted for 8 weeks, 3 times a week. In order to control the effects, the values of peak torque and power of the flexor muscles of the elbow were isokinetically measured for the angular velocities of 30°/s and 60°/s. Also taken were anthropometric measurements of the arm and the creatine kinase (CK) activity in the blood plasma. As a result of the training, significant increases of biomechanical values were noted only in group A: power increased over 20%, the peak torque over 14%. After the training, significant increases of arm circumference in the relaxed position were noted in group A (17 mm), as well as in group B (11 mm). Also, some changes in CK activity were observed between Monday and Friday in a training week. On the basis of the experimental measurements, it may be ascertained that training elbow flexor muscles on a machine with a variable-cam is more efficient for increases in strength and power, as well as for some anthropometric parameters, than training on a machine with a disc plate.
Źródło:
Acta of Bioengineering and Biomechanics; 2013, 15, 4; 93-102
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies