Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Yu, Q." wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
Plantar pressure analysis of above-knee amputee with a developed microprocessor-controlled prosthetic knee
Autorzy:
Cao, W.
Yu, H.
Meng, Q.
Li, S.
Powiązania:
https://bibliotekanauki.pl/articles/306983.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
ciśnienie podeszwowe
proteza stawu kolanowego
analiza chodu
plantar pressure
above-knee amputee
microprocessor-controlled
prosthetic knee
gait analysis
Opis:
Human gait motion analysis was one useful method for lower limb prosthesis study. The most often measured parameters were plantar pressure, kinetic and kinematic parameters. It was indispensable for prosthetic knee design and performance assessment. The aim of this study was to analysis the plantar pressure in traumatic above-knee amputee equipped with a developed microprocessor-controlled prosthetic knee. Methods: The maximum force of forefoot and rearfoot, the average vertical reaction force and pressure and the centre of pressure (COP) offset trajectories of ten above-knee amputees under different walking speeds were obtained. Results: Both forefoot and rearfoot force were bigger in intact leg than prosthetic leg. As the speed increased, the pressure increased in both sides. Forefoot bore more pressure than rearfoot in both legs. The average vertical pressure and force both increased along with the increase of speed. The force and pressure of intact side were always bigger than the prosthetic side. The trend of COP and gait line of the prosthetic and intact side had no significant difference. The length of the gait line of prosthetic side was greater than the intact side. Conclusions: The results of this study exhibited reduced plantar pressure in the prosthetic side. The typical butterfly diagrams were produced during different walking speeds. It indicated that the stability of the microprocessor-controlled prosthetic knee could be guaranteed.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 4; 33-40
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of the microcrack shape, size and direction on the poroelastic behaviors of a single osteon: a finite element study
Autorzy:
Cen, H-P.
Wu, X-G.
Yu, W-L.
Liu, Q-Z.
Yia, Y-M.
Powiązania:
https://bibliotekanauki.pl/articles/306642.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
poroelastyczność
mikropęknięcie
elementy skończone
osteon
poroelasticity
microcrack
finite element
Opis:
In this work, a finite element study is proposed by using the Comsol Multiphysics software to evaluate the effects of microcrack shape, size and direction on the poroelastic behaviors of a single osteon. Methods: This finite element model is established by using the Comsol Multiphysics software, and we just focus on the comparison of the influences of those microcrack geometric parameters on the osteonal fluid pressure and velocity. Results: The results show that: (1) microcracks in the osteon wall can induce a release of the fluid pressure, but enlarge the velocity in this region; (2) equal-area microcrack with ellipsoid-like shape produced a larger fluid pressure and velocity fields in the osteon than that of rectangular shape; (3) in the elliptic microcracks, the longer of the length (major semi-axis) induces a smaller fluid pressure and velocity amplitudes, whereas the width (minor axis) has little effect; (4) the direction of the microcracks (major axial direction) has an limited influence area around about 1/15 of the osteon cross-sectional area. Conclusions: This model permits the linking of the external loads and microcracks to the osteonal fluid pressure and velocity, which can be used for other purpose associate microcracks with the mechanotransduction and bone remodeling.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 1; 3-10
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies