Tytuł:
Analysis of the influence of the transducer and its coupling layer on round window stimulation
Autorzy:
Liu, H.
Xu, D.
Yang, J.
Yang, S.
Cheng, G.
Huang, X.
Powiązania:
https://bibliotekanauki.pl/articles/306655.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
słuch
stymulacja
przetwornik
RW
FEM
implantable middle ear hearing device
round window stimulation
transducer
coupling layer
finite element analysis
Opis:
Purpose: In this work, a finite element study is proposed to evaluate the effects of the transducer and its coupling layer on the performance of round window (RW) stimulation. Methods: Based on a set of micro-computer tomography images of a healthy adult’s right ear and reverse engineering technique, a coupled finite-element model of the human ear and the transducer was constructed and verified. Then, the effect of the cross-section of the transducer, the elastic modulus of the coupling layer, the mass of the transducer, and the preload of the transducer were studied. Results: The increase of the transducer’s cross-section area deteriorates the RW stimulation, especially at the lower frequencies. This adverse effect of the cross-section area’s increase of the transducer can be reduced by adding a coupling layer between the transducer and the RW. However, the coupling layer’s improvement on the RW stimulation is reduced with the increase of its elastic modulus. Moreover, the mass loading of the transducer decreases the RW stimulation’s performance mainly at higher frequencies and applying a static preload on the transducer enhances its hearing compensating performance at higher frequencies. Conclusions: The influence of the transducer’s mass, the mass of the transducer, the applied static preload and the properties of the coupling layer must be taken into account in the design of the RW stimulation type implantable middle ear hearing device.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 2; 103-111
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pullout evaluation of sawbone experiment in different types of pedicle screws combined with bone cement augmentation for severe osteoporotic spine
Autorzy:
Yang, S.-C.
Liu, P.-H.
Tu, Y.-K.
Powiązania:
https://bibliotekanauki.pl/articles/307271.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
osteoporoza
kości
wytrzymałość
osteoporosis
bone cement augmentation
cannulated pedicle screw
sawbone
pullout strength
Opis:
Purpose: The conventional screw is unable to provide enough screw-bone interface strength for osteoporotic cencellous bone, and complications resulting from loosening or failure of the implants remain a significant clinical problem. Hence, the purpose of this study is to investigate pullout strength and energy in three types of the pedicle screws, including conventional solid pedicle screw, cannulated pedicle screw, and cannulated pedicle screw with a central pin, using osteoporotic sawbone test block with different bone cement volumes through pullout force testing. Methods: The control group (n = 15) of the osteoporotic sawbone test block includes groups A, B, and C to reflect three types of the pedicle screws without bone cement augmentation. The cemented group (n = 45) of the osteoporotic sawbone test block includes groups D1, D2, D3, E1, E2, E3, F1, F2, and F3 to reflect three types of the pedicle screws with PMMA bone cement of 2, 3, and 4 mL augmentation. Results: The results showed that the pullout strength and energy in the cemented group were significantly larger than that in the control group. Moreover, the best performances of the pullout strength and energy in the cemented group were evidenced obviously in the case of cannulated pedicle screw with a central pin with 4 mL bone cement augmentation. Conclusions: This study concludes that cement argumentation in the cannulated pedicle screw with a central pin can increase a pullout strength of pedicle screw for severe osteoporotic patients while bone cement of injective volume is limited.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 2; 55-64
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies