Tytuł:
Relationship between performance, dry-land power and kinematics in master swimmers
Autorzy:
Espada, M. C.
Costa, M. J.
Costa, A. M.
Silva, A. J.
Barbosa, T. M.
Pereira, A. F.
Powiązania:
https://bibliotekanauki.pl/articles/307228.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
pływanie
kinematyka
energia
master swimmers
kinematic
dry-land power
performance
Opis:
The purpose of the study was to analyze the relationships between sprint swimming performance, dry-land power, and kinematics in master swimmers. Twenty-two male master swimmers were separated in two groups based on their chronological age: (i) 30–39 years and; (ii) 40–49 years. Maximum dry-land power was determined through counter movement jump and 3 kg medicine ball throwing (Hmax and Tmax, respectively). Kinematic determinants of performance were measured during a maximal bout of 15, 25 and 50 m front crawl (T15, T25, T50). Stroke frequency (SF), stroke length (SL) and stroke index (SI) were calculated as kinematical aspects of the stroke. In the 30-39 group, SI25 was correlated to T25 (r = –0.76, p < 0.01, η2 = 0.96), the same was observed between SI50 and T50 (r = –0.83, p < 0.01, η2 = 0.96). Only SI50 was significantly correlated to T50 (r = –0.86, p < 0.01, η2 = 0.97) in the 40–49 years age cohort. In dryland power variables, Hmax and Tmax were only correlated in the younger master swimmers group (r = –0.87, p < 0.01, η2 = 0.97). There were no significant differences (p < 0.05) between younger (30–39 years) and older (40–49 years) swimmers groups in dry-land tests (Hmax 28.5 ± 5.9 vs. 26.5 ± 3.9 cm and Tmax 4.2 ± 1.0 vs. 4.2 ± 1.1 m). Our results suggest that swimming performance in younger master swimmers (30–39 years) seem more dependent on kinematic swimming variables than on strength parameters, which were most related to swimming performance in the older master swimmers (40–49 years).
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 2; 145-151
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tracking young talented swimmers : follow-up of performance and its biomechanical determinant factors
Autorzy:
Morais, J. E.
Saavedra, J. M.
Costa, M. J.
Silva, A. J.
Marinho, D. A.
Barbosa, T. M.
Powiązania:
https://bibliotekanauki.pl/articles/951824.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
prepubescent swimmers
longitudinal assessment
kinematics
drag force
anthropometrics
efficiency
kinematyka
efektywność
pływak
biomechanika
Opis:
The aim of the study was to follow-up the stability of young talented swimmers’ performance and its biomechanical determinant factors (i.e., anthropometrics, kinematics, hydrodynamics and efficiency) during a competitive season. Thirty three (15 boys and 18 girls) young swimmers (overall: 11.81 ± 0.75 years old and Tanner stages 1–2 by self-evaluation) were evaluated. Performance, anthropometrics, hydrodynamics, kinematics and efficiency variables were assessed at three moments during a competitive season. Performance had a significant improvement (with minimum effect size) and a moderate-very high stability throughout the season. In the anthropometrics domain all variables increased significantly (ranging from without to minimum effect size) between moments and had a moderate-very high stability. Hydrodynamics presented no variations between all moments and had a low-very high stability throughout the season. In the kinematics domain, there were no variations between moment one and three, except for an increase in stroke frequency (without size effect). Speed fluctuation remained constant, with no significant variations. All kinematic variables had a low-very high stability. Efficiency variables did not present variations between moment one and three and had a low-moderate stability. Overall, young swimmers showed a minimum improvement in performance and in anthropometric factors; and a moderate stability of performance and its determinant factors (i.e., anthropometrics, hydrodynamics, kinematics and efficiency) during the competitive season.
Źródło:
Acta of Bioengineering and Biomechanics; 2013, 15, 3; 129-138
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of isometric strength of the shoulder rotators in swimmers using a handheld dynamometer : a reliability study
Autorzy:
Coinceicao, A.
Parraca, J.
Marinho, D.
Costa, M.
Louro, H.
Silva, A.
Batalha, N.
Powiązania:
https://bibliotekanauki.pl/articles/306193.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
siłomierz
pływanie
młodzi pływacy
handheld dynamometer
prone position
young swimmers
swimming
Opis:
The purpose of this study was to determine the reliability of shoulder isometric strength assessment using the microfet 2™ dynamometer in adolescent swimmers. Methods: Twenty-nine participants (16.2 ± 1.2 years old; 59.05 ± 6.98 kg of body mass) were tested using the microfet 2™ dynamometer. Swimmers performed an isometric strength test (IST) in two distinct occasions with 7 days apart in order to calculate the reliability. All participants were asked to perform a maximal isometric contraction from the external and internal shoulder rotators in a prone body position. Results: The external and internal shoulder rotators showed an excellent intraclass correlation coefficients for both shoulders, with more than 0.90 and a low percentage of method error variation. The external/internal ratios reliability was good in dominant (ICC 0.80) and non-dominant (ICC 0.81) shoulders. The reliability using Bland–Altman method showed that systematic errors (mean difference between test-retest) were nearly zero and the 95% limits of agreement narrow, indicating a good reliability. Conclusions: It can be concluded that microfet 2™ is a reliable apparatus for measuring the strength of the external and internal rotation of the shoulder in swimmers. Its light weight and easy portable characteristics can help swimming coaches monitoring specific dry-land strength training programs for their swimmers.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 4; 113-119
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies