Tytuł:
Patient-specific finite element analysis of frictional behavior in different esophageal regions during endoscopy
Autorzy:
Lin, Chengxiong
Ren, Pan
Li, Wei
Deng, Hengyi
Zhou, Zhongrong
Powiązania:
https://bibliotekanauki.pl/articles/27324143.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
human esophagus
frictional behavior
finite element model
patient
przełyk człowieka
zachowanie cierne
model elementów skończonych
pacjent
Opis:
Endoscopy is a common and effective method to treat digestive system diseases. Not only can it detect the physiological state of the digestive tract, but also can conduct clinical operations. As a result, it’s of great significance to make clear the relationship between the clinical operation and the complications. Methods: Considering the difficulty in measuring the contact force and determining the stress distribution in real time during endoscopy, a specific-patient finite element model for the frictional behavior at the endoscope-esophagus interface was built in current study. By collecting the CT data of the patient, a 3D esophagus model was built and divided into three characteristic regions (narrow region, thoracic region and abdominal region) according to the physiological structure. Results: Results showed that the radius of the narrowest position was the dominant factor for the maximum von Mises stress when the endoscope passed through the narrow region. For abdominal region and thoracic region, with the increasing coefficient of friction (COF) and amplitude, the total force duo to frictional force (CFSM), frictional dissipation (FD), strain energy (SE) and maximum von Mises stress (Max) all increased correspondingly. Meanwhile, the region of stress concentration gradually approached the initial contact stage. Conclusions: The results can provide theoretical basis and technical support for clinical application and offer some suggestions for medical workers during endoscopy as well.
Źródło:
Acta of Bioengineering and Biomechanics; 2020, 22, 2; 11--24
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of sound on standing postural stability in the elderly with and without knee osteoarthritis
Autorzy:
Hengsomboon, Pichaya
Hiengkaew, Vimonwan
Hsu, Wei-Li
Bovonsunthonchai, Sunee
Powiązania:
https://bibliotekanauki.pl/articles/306232.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
starzenie się
choroba zwyrodnieniowa
staw kolanowy
ageing
auditory
balance
knee osteoarthritis
sensory reweighting
Opis:
The aim of the study was to investigate the influence of sound on standing postural control in the elderly with and without knee osteoarthritis (knee-OA). Methods: Twenty-six elderly with knee-OA and 26 elderly without knee-OA who matched the age and height participated in this study. The standing postural stability was assessed by the 3D motion analysis system. Four testing conditions of the combination of sound (no sound and white noise sound) and surface (firm and soft surfaces) were tested three times with eyes closed for 30 sec. Postural stability variables included the standard deviation and velocity of the centre of pressure, the total body centre of mass, and centre of the head along the antero-posterior (AP) and medio-lateral (ML) directions. Results: Statistical significant reductions of all variables along ML direction were found in the elderly without a knee-OA in the presence of sound during standing on a firm surface. No significant effect of sound was found in the elderly with the knee-OA during standing on a firm surface. In the standing on a soft surface, both groups demonstrated no significant effect of sound on all postural stability variables. Conclusions: Application of sound improved the standing postural stability in the frontal plane for the elderly without knee-OA. However, the effect of sound was limited in standing on a soft surface for both elderly with and without knee-OA.
Źródło:
Acta of Bioengineering and Biomechanics; 2019, 21, 3; 99-108
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluating measurement accuracy and repeatability with a new device that records spatial knee movement
Autorzy:
Tian, Fei
Huang, Qiuyue
Zheng, Zhi
Li, Ningwei
Zhu, Ting
Dai, Wei
Wang, Shaobai
Powiązania:
https://bibliotekanauki.pl/articles/27324129.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
gait analysis
repeatability
motion analysis
three-dimensional
knee joint
analiza chodu
powtarzalność
analiza ruchu
trójwymiarowy
staw kolanowy
Opis:
Purpose: A novel portable system has been used to evaluate spatial knee movement, but its accuracy and repeatability is not known. The aim of this study was to investigate the accuracy and repeatability of the measurement. Methods: Ten healthy participants were included, and the knee motion trajectory during walking were assessed. Six evaluations were conducted (three days by two raters) for each participant. The motion parameters at the key points and the range of motion were statistically analyzed. Intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and the Bland–Altman method were used. Results: For intra-rater repeatability, 1) the ICC values range from 0.75 to 0.9 for rotations; and 0.64 to 0.96 for translations. Among the ICC values, 100% of rotations and 90% of translations were not less than 0.70; 2) among the SEM values, 100% of rotations were not more than 5°, while 73.3% of translations were less than 3 mm. For inter-rater repeatability, 1) the ICC values range from 0.68 to 0.99 for rotations; and 0.57 to 0.93 for translations. Among the ICC values, 95.6% of rotations and 82.2% of translations were not less than 0.70; 2) among the SEM values, 100% of rotations were not more than 5°, and 48.9% of translations were less than 3 mm. The Bland–Altman plots showed good agreement for intra- and inter-repeatability. Conclusions: The results indicated that the accuracy and repeatability of the measurement were acceptable, except for the inter-rater repeatability for translation. This may help researchers and physicians better interpret the measurement data.
Źródło:
Acta of Bioengineering and Biomechanics; 2020, 22, 3; 55--67
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biomechanical evaluation of tendon connection with novel suture techniques
Autorzy:
Chen, Z.
Wang, J.
Wei, J.- S.
Hou, Z.-Y.
Li, M.
Chen, Q.-X
Powiązania:
https://bibliotekanauki.pl/articles/306902.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
ścięgno Achillesa
IFLL
biomechanika
internal fixation with limited loop
Achilles tendon
biomechanics
Opis:
Achilles tendon rupture is a severe injury with poor curative effect due to its anatomical characteristic and mechanical peculiarity. Internal fixation of limited loop (IFLL) with steel-wire has been applied on patients with tendon rupture to fix the broken ends before physical rehabilitation. The purpose of this study is to investigate the biomechanical property and radiological characteristic of such suture technique for the repairment of tendon rupture. Methods: Tendons of pigs’ hint feet were separated for the biomechanical study. Suture surgery was performed according to the protocol of IFLL. Biomechanical Testing Machine was adopted to conduct the biomechanical tensile load examination. The maximal load, elastic modulus and tendon stiffness of the stitched tendons with or without reinforcement were examined. Results: The maximum tensile load of the stitched tendons using IFLL reached 1/4 of the uninjured tendon’s maximum tensile load, indicating that such suture technique is capable of providing enough tension for the ruptured tendon. Surprisingly, tendons fixed with titanium wire showed the highest load tension, which was comparable to the undamaged tendon. Therefore, we found the biomechanical basis of using IFLL in effectively connecting the rupture ends of tendons. Conclusions: In conclusion, we provide biomechanical evidence for the use of IFLL in treatment of Achilles tendon rupture, by providing enough strength for the ankle function. Such suture technique could help the patients with better rehabilitation and reduced in-hospital stay after Achilles tendon injury.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 1; 135-141
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies