Wyszukujesz frazę "removable denture" wg kryterium: Wszystkie pola


Wyświetlanie 1-3 z 3
Tytuł:
Chewing efficiency and occlusal forces in PMMA, acetal and polyamide removable partial denture wearers
Autorzy:
Macura-Karbownik, A.
Chladek, G.
Żmudzki, J.
Kasperski, J.
Powiązania:
https://bibliotekanauki.pl/articles/306359.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
materiał protetyczny
wyjmowana proteza częściowa
materiały termoplastyczne
denture base material
removable partial denture
chewing efficiency
occlusal force
thermoplastic materials
Opis:
Purpose: Thermoplastic materials, such as acetal (AC) and polyamide (PA), constitute an alternative to polymethyl methacrylate (PMMA) based resins as the materials for removable partial dentures. However, none of the previous studies compared chewing efficiency and occlusal forces in the wearers of dentures made of various materials. Therefore, the aim of this study was to determine and compare the chewing efficiency and occlusal forces in PMMA, PA and AC RPDs’ wearers. The hypothesis was that the type of denture base material shows a significant effect on chewing efficiency (expressed as a degree of food fragmentation) and occlusal force. Methods: The experiment included the group of 30 patients using removable partial dentures. The dentures made of PMMA, acetal and polyamide were tested in each patient. Each denture was worn for 90 days, with a random sequence of the denture manufacturing and insertion. After 7, 30 and 90 days of each denture wear, chewing efficiency coefficient was determined with the aid of a sieving method, and occlusal force was measured with a dynamometer. Results: The use of dentures made of PMMA or acetal was reflected by a marked increase in chewing efficiency and occlusal force. None of these parameters changed significantly with the time of denture wear. Moreover, no significant correlation was found between chewing efficiency and occlusal forces. Conclusions: Denture base material exerts significant effects on the degree of food fragmentation and the level of occlusal forces. The use of dentures and clasps made of materials with lower modulus of elasticity is associated with lower chewing efficiency and lower occlusal forces.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 1; 137-144
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The analysis of the effect of wrought wire clasps on the conditions of abutment teeth
Autorzy:
Kasperski, J
Chladek, G.
Płonka, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/307034.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
wrought wire clasp (WWC)
wear
removable partial denture
spring constant
zużycie zębów
sprężyna wielokrotna
wyjmowana proteza częściowa
Opis:
Laboratory evaluation of spring constants (k) of wrought wire clasps (WWC) separated from removable partial denture (RPD) and the results of tibological tests which represent the dependence of enamel wear with normal force have been presented in the paper. The results of laboratory examinations have been combined with the results of clinical assessment of the level of abutment teeth wear. On the basis of the examinations performed it has been revealed that the following factors have the greatest impact on tribological wear of abutment teeth: the time of using RPD and the normal force exerted by WWC on abutment tooth. Normal force depends to a great extent on the place of contact of WWC with the tooth. It has also been found that abutment teeth featuring higher scale of wear are more loosened. The diameter of wire used for making WWC, total length of the arm and k determined for the total length of the arm did not have any impact upon the scale of wear of abutment teeth.
Źródło:
Acta of Bioengineering and Biomechanics; 2013, 15, 1; 27-33
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the electrolytically polished skeletal dentures surfaces using various nano- and microscopic technologies
Autorzy:
Dąbrowa, Tomasz
Majstrzyk, Wojciech
Tamulewicz, Magdalena
Piasecki, Tomasz
Kunicki, Piotr
Więckiewicz, Włodzimierz
Gotszalk, Teodor
Powiązania:
https://bibliotekanauki.pl/articles/306706.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
chropowatość powierzchni
skaningowa mikroskopia elektronowa
proteza ruchoma
mikroskopia skaningowa
surface roughness
scanning electron microscopy
removable partial denture
scanning probe microscopy
optical profilometry
Opis:
The surface roughness of the dental restorations is significant to the denture plaque adhesion. Methods: In this work, we present the complex analysis of the electropolished CoCrW alloy remanium® star (Dentaurum, Germany) samples with laserengraved fiducial marks performed using complementary set of micro- and nanoscopic techniques: optical profilometry (OP), atomic force microscopy (AFM), scanning electron microscopy (SEM) and focused ion beam (FIB) milling. Results: Both mean and RMS roughness of the samples were reduced by electopolishing process, however, the results obtained using OP and AFM exhibited some discrepancies. This was caused by the relatively high local protruding defects developed on the processed surface. The cross-sections of the protrusions were made to analyze the cause of their formation as the EDS elemental content maps revealed that their composition was uniform. We also analyzed the local roughness in the smaller areas free from the defects. Conclusions: In that case, both OP and AFM techniques delivered the same results. Analysis of results showed that various methods used for the surface roughness evaluation have to be used simultaneously to obtain complete and true analysis of the technological CoCrW samples.
Źródło:
Acta of Bioengineering and Biomechanics; 2019, 21, 4; 123-129
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies