Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "jama" wg kryterium: Wszystkie pola


Wyświetlanie 1-2 z 2
Tytuł:
Gait changes in patients after reconstruction of facial bones with fibula and iliac crest free vascularized flaps
Autorzy:
Syczewska, M.
Krajewski, R.
Szczerbik, E.
Kalinowska, M.
Powiązania:
https://bibliotekanauki.pl/articles/949745.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
wzorzec chodu
chirurgia rekonstrukcyjna
nowotwór złośliwy
jama ustna
gait pattern
reconstructive surgery
malignant tumour
oral cavity
Opis:
Patients with malignant tumours of the oral cavity require its surgical removal and reconstruction of the bone and soft tissues. The grafts are obtained either from leg (fibula) or pelvis (iliac crest). The removal of grafts from the locomotor apparatus can impair the gait. The aim of this study was to find out how the localization of donor site influences the gait pattern. Methods: Results obtained for 30 patients were analyzed (16 fibula graft, 14 iliac crest graft). Patients underwent instrumented gait analyses three times (VICON system): before surgery, 2–4 month after the surgery, and 4–8 months after the surgery. Results: In both groups several gait parameters were changed. Two parameters changed in both groups: gait speed and cadence. In patients receiving iliac crest graft the changed gait variables were: pelvic rotation, hip range in sagittal plane (operated side), knee range in sagittal plane (operated side), foot dorsiflexion in swing on both sides. In patients receiving fibula flap the changed gait variables were: tilt, range motion of the tilt, minimum hip flexion (operated side), time to maximum knee flexion (non-operated side), GGI (non-operated side) and step length (nonoperated side). Conclusions: The primary gait deviations occurring after surgery, and the compensatory mechanisms which subsequently arise depend on the localization of graft donor site. The results indicate that the patients in whom fibula flap was used have less problems with gait pattern after the surgery than the patients receiving iliac crest graft.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 1; 185-190
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of reliability of perioral muscle pressure measurements using a newly developed device with a lip piece
Autorzy:
Takahashi, M.
Koide, K.
Suzuki, H.
Satoh, Y.
Iwasaki, S.-I.
Powiązania:
https://bibliotekanauki.pl/articles/306575.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
nacisk
wiarygodność
mięśnie
jama ustna
tongue pressure
upper lip pressure
lower lip pressure
absolute reliability
relative reliabilit
Opis:
Purpose: We examined the reliability of measurements using a newly developed perioral muscle pressure measuring device with a lip piece in healthy adults. Methods: Subjects were 40 healthy men (25.8 years) with normal stomatognathic function. Perioral muscle pressure measuring device with a lip piece was used to measure upper lip, lower lip and tongue pressure, and a balloon-based measurement device was used to measure tongue and cheek pressure. Each measurement was taken twice with a 1-min interval between the two measurements. We determined intra-rater reliability by using the intra-class correlation coefficient as a test of relative reliability. As a test of absolute reliability, Bland–Altman analysis was used to assess systematic bias and the 95% confidence interval of the minimal detectable change was calculated. Additionally, the coefficient of variation was calculated. The Spearman–Brown formula was calculated the number of measurements needed to achieve a confidence coefficient ≥0.9. Each set of measurements was followed by a second set that were taken 1 week later. Results: All measurements showed high values of intra-class correlation coefficient. Upper lip, tongue, and cheek pressure can be determined based on a single measurement, while lower lip pressure requires averaging twice. No systematic bias was observed. The coefficients of variation of measurements were almost the same between the two devices. Conclusion: Measurements were highly reliable regardless of the type of perioral muscles. Our findings suggest that the method described in this study is useful as a quantitative chair side method for examining perioral muscle pressure.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 1; 145-153
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies