Tytuł:
Role of initial density distribution in simulations of bone remodeling around dental implants
Autorzy:
Nutu, E.
Powiązania:
https://bibliotekanauki.pl/articles/307275.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
energia odkształcenia
kość
warunki początkowe
przebudowa kości
strain energy density
bone quantity
initial conditions
bone remodeling simulation
Opis:
In this paper, the effect of initial density distribution upon the predicted density via numerical simulations of bone remodeling was evaluated. The main purpose was to correlate the numerical results with clinical data according to which the initial bone quantity is an essential factor for long term survival of dental implants. Methods: Two-strain energy density-based bone remodeling theories were employed, one which accounts for overload resorption and the second one, which does not. The remodeling parameters were derived from the mechanostat theory. Bone remodeling around an osseointegrated dental implant was simulated based on finite element method using a generic mandible plane model. A variable time step was introduced to increase the speed of the remodeling simulations by keeping the truncation errors small. The simulations were performed for several initial density distributions correlated with values from clinical classifications of bone quality. For each density value, the occlusal load was defined in two ways so that to consider normal and overload mastication forces, respectively. Results: The results showed that the initial density distribution influences the predictions of bone remodeling simulations. For the analyzed model, the remodeling algorithm predicted overload resorption only in the case of low initial density, which can be associated with low bone quality, which, from clinical perspective, may probably lead to implant loss. Conclusions: The paper demonstrated that when simulating bone remodeling around dental implants using finite element method, it is important to account for initial density distribution in correlation with the bone quantity.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 4; 23-31
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of the material’s stiffness on stress-shielding in osseointegrated implants for bone-anchored prostheses: a numerical analysis and initial benchmark data
Autorzy:
Prochor, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/27324152.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
Young’s modulus
bone mass
bone remodelling
osseointegration
bone-anchored prosthesis
moduł Younga
masa kostna
przebudowa kości
osteointegracja
proteza zakotwiczona w kości
Opis:
This study attempted to establish the link between design of implants for bone-anchored prostheses and stress-shielding, affecting the stability of the bone-implant coupling using numerical approach. The objectives were to share a numerical model capable to evaluate the long-term stability of implants and to use this model to extract data sets showing how shape and material stiffness of threaded, press-fit and modular press-fit implants affect stress-shielding intensity. Methods: Three designs were considered: threaded, press-fit and modular press-fit. The effect of shape and material stiffness of each design on stress-shielding intensity was assessed using Young’s modulus (10 to 210 GPa). Furthermore, the impact of the diameter of percutaneous part (10 to 18 mm) and thickness of medullar part (5 to 1 mm) was investigated for the modular press-fit implant. Results: The threaded design generated 4% more bone mass loss at the distal femur but an overall loss of bone mass was by 5% lower to press-fit design. The influence of Young’s modulus on bone mass changes was noticeable for modular press-fit implant, depending on diameter of percutaneous or medullary part. A 20 GPa change of stiffness caused a bone mass change from 0.65% up to 2.45% and from 0.07% up to 0.32% for percutaneous parts with 18 mm and 10 mm diameter, respectively. Conclusions: Results suggested that threaded implant provides greater stability despite an increased bone loss at the distal femur. Altogether, this work provided an initial model that could be applied in subsequent studies on the long-term stability of current and upcoming implants.
Źródło:
Acta of Bioengineering and Biomechanics; 2020, 22, 2; 69--81
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechanical response at peri-implant mandibular bone for variation of pore characteristics of implants: A Finite Element Study
Autorzy:
Sarkar, Sulagna
Sahu, Tikeshwar Prasad
Datta, Arijit
Chandra, Nimesh
Chakraborty, Arindam
Datta, Pallab
Majumder, Santanu
Chowdhury, Amit Roy
Powiązania:
https://bibliotekanauki.pl/articles/307131.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
implant stomatologiczny
uszczelnianie
FEM
porous dental implant
pore size
percentage porosity
bone-implant interface
finite element analysis
stress and strain
Opis:
In this paper, the mechanical response of generic dental implants having calculated porosities with varying pore-sizes has been evaluated. The purpose of this study was to compare the developed stress-strain of designed porous implants (i.e., stress at the implant and strain at the peri-implant bone) with that of the non-porous implant. Methods: 3D model of a mandible was prepared from CT scan data and nine generic dental implant models have been designed having 10%, 20%, and 30% porosity with 500, 700, and 900 micron pore size along with a non-porous model for carrying out FE analyses. First, failure analyses of implants, under a biting force of 250 N have been performed. Next, the remaining implants have been further evaluated under average compressive chewing load of 100 N, for mechanical responses at bone-implant interface. Results: Von Mises strain at the peri-implant mandibular bone increases with the increase in percentage porosity of the implant material and maximum implant stress remained much below the yield stress level. Conclusion: Implant stiffness and compressive strength vary as a function of porosity and pore size. Strain obtained on the peri-implant bone is sufficient enough to facilitate better bone growth with the 700 micron pore size and 30% porosity, thus reducing the effect of stress shielding.
Źródło:
Acta of Bioengineering and Biomechanics; 2019, 21, 2; 83-93
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies