Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Paluch, M." wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
Dielectric Spectroscopy Studies of 4-Cyano-3-fluorophenyl 4-Butylbenzoate Liquid Crystal at High Pressure
Autorzy:
Rozwadowski, T.
Massalska-Arodź, M.
Juszyńska, E.
Krawczyk, J.
Wojnarowska, Ż.
Paluch, M.
Powiązania:
https://bibliotekanauki.pl/articles/1419574.pdf
Data publikacji:
2012-08
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
64.70.M-
77.22.Gm
Opis:
For 4-cyano-3-fluorophenyl 4-butylbenzoate, nematic glassformer at ambient pressure, dielectric relaxation studies were performed under elevated pressure. In the isobaric experiment, on cooling the nematic phase two superarrhenius α-relaxations, ascribed to the reorientations of molecules around short axes and precession of long molecular axes were found and the Arrhenius β-relaxation related to intramolecular motions. Complexity of dynamics at elevated and ambient pressure is similar. Shift towards lower frequencies was found for both α-relaxations.
Źródło:
Acta Physica Polonica A; 2012, 122, 2; 378-381
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Enhanced External Counterpulsation in Patients with Advanced Ischemic Cardiomyopathy
Autorzy:
Przywara-Chowaniec, B.
Gawlikowski, M.
Kuczaj, A.
Bachorz, M.
Czechowski, P.
Kowalski, P.
Geodecki, M.
Kawecki, D.
Barańska, K.
Paluch, M.
Pluszczyk, M.
Opara, M.
Puzio, A.
Nowalany-Kozielska, E.
Powiązania:
https://bibliotekanauki.pl/articles/1418031.pdf
Data publikacji:
2012-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
47.63.Ec
82.60.Fa
Opis:
A significant increase in the number of patients with heart failure of varied etiology has been observed in the recent years. Apart from pharmacological and surgical therapies, new, non-invasive assistance methods of cardiovascular system are still sought. One of them is external counterpulsation. Within this study, effectiveness of such a form of therapy has been examined in a group of 10 patients with an ischemic left ventricular systolic dysfunction. It has been shown that external counterpulsation has a beneficial influence onto the result of a six-minute walk test and causes a slight decrease in the creatinine concentration in the patients undergoing the tests.
Źródło:
Acta Physica Polonica A; 2012, 122, 5; 866-869
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies