Tytuł:
Arc models for simulating processes in circuits with a SF6 circuit breaker
Autorzy:
Sawicki, Antoni
Powiązania:
https://bibliotekanauki.pl/articles/140610.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
switching arc
high-voltage circuit breaker
Mayr model
Opis:
This paper demonstrates that if a linear dependence of arc dissipated power on power supplied is introduced at an initial stage of analysis, then, with some simplifying assumptions, the classical Mayr model is obtained. Similarly, if this dependence is taken into account in a model with residual conductance, the modified Mayr model is obtained. The study takes into consideration the local phenomenon of sudden voltage drop accompanying linear current decrease occurring in the circuit breaker. To account for this phenomenon, the Dirac delta function and its approximation by a Gaussian function, representing power or enthalpy disturbances, are introduced to the power balance equation. It is demonstrated that both variants yield the same effect, leading to identical differential equations. Macromodels of the circuit-breaker arc are created and connected with the power source circuit with lin- early decreasing current. The results obtained were found to be consistent with experimental data available in the literature. The models presented are based on a fairly uncomplicated 1st order differential equation and offer a straightforward physical interpretation of the phenomena in question.
Źródło:
Archives of Electrical Engineering; 2019, 68, 1; 147-159
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dobór zabezpieczeń dla wyłączników sterowanych radiowo w liniach elektroenergetycznych średniego napięcia SN
Protection of radio controlled switches in MV power grids
Autorzy:
Chrzan, M.
Pietruszczak, D.
Sankowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/317030.pdf
Data publikacji:
2018
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
sterowanie radiowe
telematyka
wyłącznik średnich napięć SN
radio control
telematics
MV medium voltage circuit breaker
Opis:
W artykule zaprezentowano analizę technologiczno-konstrukcyjną wyłącznika średniego napięcia SN typu GVR RECLOSER sterowanego zdalnie oraz odpowiedniego doboru jego zabezpieczeń.
The paper presents the technology and construction analysis of the GVR RECLOSER MV switch, remotely controlled and the appropriate selection of its protections.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2018, 19, 12; 350-355
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indirect test circuit for testing high voltage fuses in overload conditions
Układ do zastępczych badań bezpieczników wysokiego napięcia na prądy przeciążeniowe
Autorzy:
Kuraszkiewicz, J.
Bandel, J.
Hejduk, A.
Krasuski, K.
Dzierżyński, A.
Staniszewski, K.
Powiązania:
https://bibliotekanauki.pl/articles/158595.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
bezpieczniki wysokiego napięcia
próba przeciążeniowa
cykl łączeniowy nr 3
metoda dwuźródłowa
przełącznik ultraszybki
high voltage fuse
fast operating switch
current circuit
voltage circuit
Opis:
Próba określenia zdolności wyłączania prądów przeciążeniowych bezpieczników na wysokie napięcie wykonywana w układzie bezpośrednim związana jest z koniecznością długotrwałego obciążenia bezpiecznika dużym prądem w obwodzie wysokiego napięcia. Zamiast układu do badań bezpośrednich można korzystać z układu zastępczego, dwuźródłowego, w którym nagrzewanie bezpiecznika odbywa się w obwodzie niskonapięciowym, a dopalanie w obwodzie wysokiego napięcia. Dla równoważności obu prób konieczne jest dokonanie przełączenia z jednego układu na drugi w możliwie najkrótszym czasie. W artykule opisano również ultra szybki przełącznik, który pozwala na takie przełączenie i pokazano przykładowy przebieg próby.
During direct tests of high voltage fuses in overload conditions, the tested fuse has to carry the rated overload current at the rated voltage for a long enough time to interrupt the overcurrent. These types of tests cannot be done in short circuit laboratories. A short circuit generator cannot be excited for the length of time needed to complete the test. Therefore the indirect test method is often applied. It uses separate current and voltage circuits in sequence: first the fuse is supplied from a low voltage current circuit to conduct a current of the recommended intensity and, at the moment of the current interruption, the fuse is disconnected from the low voltage circuit and switched to a high voltage circuit. To ensure the equivalence of the direct and indirect tests the switching time from the current to the voltage circuit should be as short as possible. This paper describes a fast operating switch for use in such tests.
Źródło:
Prace Instytutu Elektrotechniki; 2016, 274; 83-87
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Based on neural network adaptive linear quadratic regulator for inverter with voltage matching circuit
Autorzy:
Niewiara, Ł.
Tarczewski, T.
Grzesiak, L.M.
Powiązania:
https://bibliotekanauki.pl/articles/97686.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
adaptive linear-quadratic regulator
voltage matching circuit
artificial neural network
current ripple
Opis:
This paper describes a discrete adaptive linear quadratic regulator used to load current control in terms of variable DC voltage of inverter. Controller was designed by using linear quadratic optimization method. Adaptive LQR was used because of non-stationarity of the control system caused by Voltage Matching Circuit - VMC. Gain values of the adaptive controller were approximated by using an artificial neural network. The VMC was realized as an additional buck converter integrated with the main inverter. As the load of the 2-level inverter a 3-phase symmetric RL circuit was used. Simulation tests show the behavior of the load current regulation during DC bus voltage level step changes. The dependence between current RMS value and inverter DC bus voltage level was also shown. There were also made a comparison of the traditional 2-level inverter structure with the modified structure uses VMC. Simulation test was made by using Matlab Simulink and PLECS software.
Źródło:
Computer Applications in Electrical Engineering; 2014, 12; 434-443
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Neural network based adaptive state feedback controller for inverter with voltage matching circuit
Autorzy:
Niewiara, Ł.
Tarczewski, T.
Grzesiak, L. M.
Powiązania:
https://bibliotekanauki.pl/articles/376361.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
adaptive linear-quadratic controller
voltage matching circuit
artificial neural network
current ripple
Opis:
This paper describes a discrete adaptive state feedback controller used to load current control in terms of variable DC voltage of inverter. Controller was designed by using linear quadratic optimization method. Adaptive LQR was used because of non-stationarity of the control system caused by Voltage Matching Circuit - VMC. Gain values of the adaptive controller were approximated by using an artificial neural network. The VMC was realized as an additional buck converter integrated with the main inverter. As the load of the 2-level inverter a 3-phase symmetric RL circuit was used. Simulation tests show the behavior of the load current regulation during DC bus voltage level step changes. The dependence between current RMS value and inverter DC bus voltage level was also shown. Simulation test was made by using Matlab Simulink and PLECS software.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2014, 80; 231-238
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uwarunkowania czasowe wyznaczania napięcia zwarcia silników klatkowych metodą bez mechanicznej blokady wirnika
Time conditions relating to determination of short-circuit voltage of squirrel-cage motors by method of non-mechanical blocking of rotor
Autorzy:
Dzikowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/185972.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technik Innowacyjnych EMAG
Tematy:
napięcie zwarcia
ograniczenia czasowe
silnik klatkowy
short-circuit voltage
squirrel-cage motor
Opis:
Artykuł prezentuje ograniczenia czasowe jakie występują podczas wyznaczania napięcia zwarcia silników klatkowych metodą bez mechanicznej blokady wirnika. Oprócz symulacji komputerowych w artykule są przedstawione wyniki badań przeprowadzonych w laboratoriach Centrum EMAG wykonane dla grupy silników małej mocy.
The paper presents the time limits emerging during determination of a short-circuit voltage of squirrel-cage motors using a method of non-mechanical blocking of rotor. Besides the computer simulations, there have been presented the results of research works which were carried out in the laboratories of the EMAG Centre for a group of low power motors.
Źródło:
Mechanizacja i Automatyzacja Górnictwa; 2009, R. 47, nr 6, 6; 5-10
0208-7448
Pojawia się w:
Mechanizacja i Automatyzacja Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Switching and lightning overvoltages and the required withstand voltage betweeen the open contacts of 245 KV circuit breakers
Przepięcia łączeniowe i piorunowe a wymagany poziom wytrzymałości otwartych styków wyłączników 245 KV
Autorzy:
Bandel, J.
Hejduk, A.
Dzierżyński, A.
Korycki, P.
Sibilski, H.
Powiązania:
https://bibliotekanauki.pl/articles/159303.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
high voltage circuit breakers
switching inductive and capacitive currents
switching and atmospheric overvoltage
lightning arresters
wyłączniki najwyższych napięć
łączenie prądów indukcyjnych i pojemnościowych
przepięcia łączeniowe i atmosferyczne
ogranicznik napięcia
Opis:
Przedstawiono sposób oceny wartości przepięć generowanych w sieci pomiędzy otwartymi stykami wyłącznika podczas operacji łączeniowych i wyładowań piorunowych. Wartości przepięć porównano z wartościami napięć probierczych wyłączników. Zaproponowano sposób doboru ograniczników napięcia. Wyłączanie prądów zwarciowych może powodować osłabienie izolacji komory wyłącznika zmniejszając jego wytrzymałość elektryczną i trwałość łączeniową. W energetyce zgłaszano przypadki zapłonów łuku na otwartych stykach wyłączników, tego rodzaju awarie mogą być bardzo groźne w skutkach. Problem ten dotyczy przede wszystkim wyłączników jednoprzerwowych, w których naprężenia elektryczne izolacji przerwy pomiędzy stykowej wyłącznika są bardzo duże. Z tego powodu pojawiają się postulaty zwiększenia liczby łączeń podczas badań typu wyłącznika, jakie należy wykonywać bez wymiany jakichkolwiek części komory wyłącznika, czy też napędu.
This paper deals with the surges generated in the network during switching operations and lightning surges. The level of both kinds of surge was compared with the required dielectric strength between the open contacts of 245 kV circuit breakers. Overvoltages greater than the electrical withstand voltage of the circuit breaker can cause arc ignition between the circuit breaker’s open contacts and power engineering service s have reported such cases. The results of such failures can be very serious. This is a problem especially for single-break circuit breakers, in which the stresses on the electrical insulation between the open contacts of the breaker are very high. A method for selecting lightning arresters to lower the overvoltages is proposed. The switching of short-circuit currents by a circuit breaker may cause a weakening of the circuit breaker chamber’s insulation and reduce its electrical withstand and durability.
Źródło:
Prace Instytutu Elektrotechniki; 2016, 274; 43-60
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Unidirectional Protection Strategy for Multi-terminal HVDC Grids
Autorzy:
Mokhberdoran, A.
Silva, N.
Leite, H.
Carvalho, A.
Powiązania:
https://bibliotekanauki.pl/articles/136202.pdf
Data publikacji:
2016
Wydawca:
EEEIC International Barbara Leonowicz Szabłowska
Tematy:
DC circuit breaker
HVDC
Protection Device
voltage source converter (VSC)
Short-circuit
Opis:
Protection issue is identified as the main drawback of emerging multi-terminal HVDC grids. Multi-terminal HVDC grid demands fast short circuit fault current interruption. Fast DC circuit breakers as a promising solution can be implemented as either bidirectional or unidirectional devices. In addition to less implementation cost, the unidirectional DC circuit breakers have less power losses as compared to the bidirectional devices. A protection strategy for multi-terminal HVDC grid based on unidirectional breaking devices is discussed and assessed in this paper. The performance of unidirectional protection strategy is examined under different fault scenarios in a fourterminal MMC-HVDC grid model. Furthermore, the impacts of unidirectional protection strategy on power converters and also current interruption and surge arrester ratings of the DC circuit breakers are discussed.
Źródło:
Transactions on Environment and Electrical Engineering; 2016, 1, 4; 58-65
2450-5730
Pojawia się w:
Transactions on Environment and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of ferroresonance oscillations in capacitive voltage transformer
Autorzy:
Iżykowski, J.
Rosołowski, E.
Pierz, P.
Powiązania:
https://bibliotekanauki.pl/articles/410537.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
capacitive voltage transformer
ferroresonance
suppression circuit
chaotic behaviour
simulation
Opis:
Analysis of ferroresonance oscillations in capacitive voltage transformer is presented. For this purpose an analytical approach to ferroresonance is firstly introduced. With use of the harmonic balance method the condition for avoiding stable subharmonic oscillations of the 3rd mode is stated. In the next step the ATP-EMTP simulation based investigations are carried out to find the suppression circuit parameter (or parameters) which assure damping of the nonlinear oscillations in accordance to the requirements of the standards. Two kinds of suppression circuits designed for the considered capacitive voltage transformer construction are investigated. The possible chaotic phenomena resulting from nonlinear oscillations are also examined. The obtained results are pr esented and discussed.
Źródło:
Present Problems of Power System Control; 2015, 6; 43-66
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multiresonant ZVS CUK convertor
Autorzy:
Szychta, E.
Powiązania:
https://bibliotekanauki.pl/articles/262827.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
multiresonant converter
cuk circuit
zero voltage switching
resonant circuits
Opis:
The article presents properties of multiresonant ZVS Cuk converter. The control system of the converter is based on PWM technique. The operating range of the converter is defined where ZVS operation is assured. Control characteristics are given and the converter’s efficiency is defined. The converter’s operation is analysed on the basis of simulation testing.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2006, 12, 2; 95-101
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ jakości oleju na spektrum napięcia powrotnego w układach modelowych papier-olej
Influence of oil quality on recovery voltage spectrum of oil-paper insulation models
Autorzy:
Szymański, J.
Graczkowski, A.
Walczak, K.
Powiązania:
https://bibliotekanauki.pl/articles/153189.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
recovery voltage spectrum
oil resistivity
equivalent circuit of insulation
Opis:
Zbyt uproszczona interpretacja spektrum napięcia powrotnego może prowadzić do błędnej oceny zawilgocenia układu izolacyjnego papier-olej. Najwięcej kontrowersji wzbudza nieuwzględnienie w interpretacji wpływu jakości oleju na parametry spektrum polaryzacyjnego (system pomiarowy Tettex 5462 plus firmowy program do interpretacji wyników). W badaniach wykorzystano symulację komputerową oraz układy modelowe izolacji papierowo-olejowej do określenia wpływu rezystywności oleju na spektrum napięcia powrotnego. Wyniki przedstawiono w niniejszym artykule.
Very simple interpretation of recovery voltage spectrum can be the reason for incorrect evaluation of moisture content in oil-paper insulation system. The software for the recovery voltage spectrum analysis offered by Tettex does not take into consideration such important parameter like oil resistivity. In research authors used computer simulation and models of oil-paper insulation system in order to determine influence of oil quality on recovery voltage spectrum. The results of the investigations were presented in this paper.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 10, 10; 709-712
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of short-circuit ac currents on electrical contact resistance of low voltage relays
Autorzy:
Książkiewicz, A.
Janiszewski, J.
Batura, R.
Powiązania:
https://bibliotekanauki.pl/articles/378117.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
electrical contact resistance
ECR
short-circuit current
low voltage relays
Opis:
Electromagnetic relays can be exposed to many hazardous phenomena during their lifetime. The most vulnerable part of an relay to their adverse effects are his electrical contacts. One of many parameters describing electrical contacts is their resistance. In this article experiments regarding the impact of short-circuit currents at make on electrical contact resistance of electromagnetic relays is described.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2012, 70; 99-103
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Voltage induced by currents in power-line sagged conductors in nearby circuits of arbitrary configuration
Autorzy:
Budnik, K.
Machczyński, W.
Szymenderski, J.
Powiązania:
https://bibliotekanauki.pl/articles/140488.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power line
catenary
vector potential
overhead circuit
induced voltage
mutual inductance
Opis:
The study presents a calculation method of the voltage induced by power-line sagged conductor in an inductively coupled overhead circuit of arbitrary configuration isolated from ground. The method bases on the solution utilizing the magnetic vector potential for modeling 3D magnetic fields produced by sagging conductors of catenary electric power lines. It is assumed that the equation of the catenary exactly describes the line sag and the influence of currents induced in the earth on the distribution of power line magnetic field is neglected. The method derived is illustrated by exemplary calculations and the results obtained are partially compared with results computed by optional approach.
Źródło:
Archives of Electrical Engineering; 2015, 64, 2; 227-236
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transitional processes at capacitive currents switching-off by single and double-break interrupters of vacuum circuit breakers
Autorzy:
Lazimov, T.
Saafan, E.
Powiązania:
https://bibliotekanauki.pl/articles/410591.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
vacuum circuit breaker
double-break vacuum interrupters
SF6 circuit breaker
capacitor banks
transient recovery voltage
dielectric strength
breaking capacity
Opis:
Vacuum circuit breaker technology based on double-break vacuum interrupters has become the most requirements of high voltage circuit breakers that not environmentally harmful. The vacuum interrupter has an excellent ability to deal with the steep rising part of the transient recovery voltage, which makes it faster in the current interruption process. This paper presents results of computer simulations conditioned by capacitive currents switching-offs by using single and double interrupters of vacuum circuit breakers. These results demonstrate that use of double-break circuit breakers leads to notable decreasing of switching overvoltages and allows in the same time to meet the dielectric requirements for high voltage vacuum circuit breakers.
Źródło:
Present Problems of Power System Control; 2014, 5; 33-43
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Voltage dips reduction with a hybrid contectless short-circuit limiter
Ograniczenie zapadów napięcia za pomocą bezstykowego ogranicznika prądu
Autorzy:
Leśniewski, P.
Gohra, K.
Powiązania:
https://bibliotekanauki.pl/articles/152073.pdf
Data publikacji:
2003
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
łącznik hybrydowy
zapady napięcia
bezstykowy ogranicznik prądu
hybrid circuit breaker
voltage dip
contactless current limiter
Opis:
The paper presents operation of a hybrid contactless short-circuit current limiter on the basis of computer simulation. Special attention was paid to the possibility of improving of the quality of the delivered electrical energy, throught limiting of the voltage dips duration in the power grid owing to the application of a hybrid circuit breaker. The calculations were performed usingthe PSPICE and MATLAB software.
W artykule przedstawiono działanie bezstykowego ogranicznika prądów zwarciowych w oparciu o symulacje komputerową. SzczególnA uwagę zwrócono na możliwość poprawy jakości dostarczanej energii elektroenergetycznej, dzięki zastosowaniu wyłącznika hybrydowego. Modelowanie matematyczne wykonano w programie MATLAB i PSPICE.
Źródło:
Pomiary Automatyka Kontrola; 2003, R. 49, nr 12, 12; 74-76
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies