Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "quality of air" wg kryterium: Temat


Tytuł:
Ochrona powietrza przed zanieczyszczeniami – dlaczego w Polsce nie można odetchnąć pełną piersią?
Protection of Air against Pollution – Why Cannot We Get a Breath of Fresh Air in Poland?
Autorzy:
Pankowska, Marta
Gorczyca, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/417242.pdf
Data publikacji:
2015-06
Wydawca:
Najwyższa Izba Kontroli
Tematy:
quality of the air
air pollution
air protection programmes
pollutants
Opis:
At the time when Poland joined the European Union, the quality of the air in the country was far from the European standards. At the moment, the level of certain pollutants in the air is still high, which may result in legal proceedings of the European Union bodies against Poland, and consequent substantial financial charges. What is worse, it is estimated that as many as 45,000 Poles die every year due to air pollution. That is why NIK has decided to conduct an audit aimed at evaluating the activities of public entities undertaken with a view to improving the quality and protection of the air in the period between the year 2008 and the first half of the year 2014. The audit covered: the functioning of air monitoring, the development of air protection programmes by individual bodies of regional self-governments and the performance of tasks set out in these programs by competent self-government bodies, the financing of tasks related to air protection by regional funds for environmental protection and water management, as well as the coordination of activities and cooperation of organisational units with regard to the implementation of protection related measures. The audit was carried out in five regions (Małopolskie, Mazowieckie, Opolskie, Pomorskie and Śląskie), and it covered 25 auditees.
Źródło:
Kontrola Państwowa; 2015, 60, 3 (362); 60-78
0452-5027
Pojawia się w:
Kontrola Państwowa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena jakości powietrza w budynkach
Quality estimate of buildings air
Autorzy:
Basińska, M
Pańczak, M
Powiązania:
https://bibliotekanauki.pl/articles/362366.pdf
Data publikacji:
2011
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
fizyka budowli
mikrobiologiczna jakość powietrza
budynek pasywny
building physics
microbiological quality of air
passive house
Opis:
W artykule przedstawiono analizę zmienności parametrów mikroklimatu w budynku pasywnym Politechniki Poznańskiej oraz w dwóch budynkach mieszkalnych. Pomiary przeprowadzono w miesiącu grudniu 2010 roku. Badaniom podlegały parametry fizyczne oraz mikrobiologiczne powietrza. Otrzymane wyniki porównano z obowiązującymi przepisami.
The article attempts to assess the research conducted in the experimental facility of Poznań University of Technology - the passive house and in two one - family houses. Measurement was made in December 2010. The research concerns microbiological contamination of air inside the buildings. The identified mesophilic and psychrophilic bacteria, Staphylococcus, Actinomycetales, Pseudomonas fluorescens and microscopic fungi have been compared to the statutory standards.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2011, T. 6, nr 4, 4; 5-8
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jakość powietrza w pomieszczeniach edukacyjnych na podstawie kryterium stężenia CO2
The quality of air in studys`s accommodation based on criterion CO2
Autorzy:
Wolski, L.
Kamiński, A.
Powiązania:
https://bibliotekanauki.pl/articles/362659.pdf
Data publikacji:
2010
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
fizyka budowli
jakość powietrza
kryterium CO2
building physics
quality of air
criterion CO2
Opis:
W Zakładzie Instalacji Budowlanych i Fizyki Budowli prowadzone są od roku 1990 badania nad mikroklimatem pomieszczeń wielkokubaturowych. W niniejszym artykule zaprezentowano wyniki badań stężenia CO2 wewnątrz pomieszczenia Auli, jako podstawę do oceny jakości powietrza. Badania te są częścią analiz przeprowadzonych w pomieszczeniach dydaktycznych należących do Wydziału Budownictwa, Mechaniki i Petrochemii Politechniki Warszawskiej.
In the Departament of Building Instalations and Building Physics have been tracked the researches of large cuba-ture's microclimate since 1990. In this article will be presented the researches of concetraction of CO2 inide the assembly hall. These researches are the part of the main one what was executed in accommodation of studies room of Faculty Of Civil Engineering, Mechanics And Petrochemistry, Warsaw University of Technology.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2010, T. 5, nr 2, 2; 65-69
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fungia obiektów muzealnych na przykładzie Muzeum Pałacu Króla Jana III w Wilanowie
Fungi in museum objects: a case study of Museum of King Jan III’s Palace at Wilanów
Autorzy:
Wójcik, A.
Oleksiewicz, A.
Andres, B.
Laudy, A.
Powiązania:
https://bibliotekanauki.pl/articles/218601.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Konserwatorów Zabytków
Tematy:
grzyby pleśniowe
kolekcja muzealna
czystość powietrza
zarodniki grzybów
molds
museum collection
quality of air
fungi spores
Opis:
W artykule poruszony został problem występowania w obiektach muzealnych, gdzie wystawiane są lub przechowywane kolekcje zabytków: obrazy, meble, tkaniny i książki, grzybów pleśniowych. Praca dotyczy badania stanu natężenia zarodników grzybów w powietrzu w poszczególnych pomieszczeniach w Muzeum Pałacu Króla Jana III w Wilanowie i omówienia rozpoznanych tam rodzajów i gatunków grzybów pleśniowych, których zarodniki zostały pobrane w czasie badań.
The article described the problem of the presence molds in museum objects, which are issued or stored collections of historical paintings, furniture, textiles and books. The work concerns the research of the intensity of fungal spores in the air in individual rooms in the Palace Museum, King Jan III in Wilanów and discussion there recognized genus and species of fungi, whose spores were collected during the study.
Źródło:
Wiadomości Konserwatorskie; 2015, 41; 92-98
0860-2395
2544-8870
Pojawia się w:
Wiadomości Konserwatorskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ rodzaju spalanego paliwa oraz urządzenia grzewczego na jakość powietrza atmosferycznego
Impact of the type of fuel burned and the heating device on the quality of atmospheric air
Autorzy:
Wierzbińska, Monika
Adamus, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/400341.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
model Pasquill’a
imisja zanieczyszczeń
jakość powietrza
spalanie paliw
Pasquill’s model
immision
quality of atmospheric air
fuel combustion
Opis:
W artykule przedstawiono ocenę wpływu rodzaju paliwa oraz urządzenia grzewczego na jakość powietrza atmosferycznego na obszarze obejmującym 15 emitorów charakterystycznych dla gospodarstw jednorodzinnych. Analizę jakości powietrza przeprowadzono obliczając stężenia zanieczyszczeń pyłowych i gazowych w atmosferze w różnych odległościach od emitorów. Pod uwagę wzięto zanieczyszczenia pyłowe i gazowe, emitowane w wyniku ogrzewania domów jednorodzinnych oraz podgrzewania wody użytkowej: pył zawieszony PM10, dwutlenek siarki, dwutlenek azotu oraz dwutlenek węgla. Przyjęto 8 wariantów urządzeń, opalanych paliwami gazowymi, stałymi i ciekłymi, w wersjach starszego typu oraz nowoczesnej. Do obliczeń imisji zanieczyszczeń wykorzystano program Ek100w firmy Atmoterm. Obliczenia wykazały, że maksymalna imisja SO2 jest 963-krotnie niższa w przypadku spalania gazu ziemnego w kotłach nowoczesnych niż podczas opalania węglem kamiennym "ekogroszkiem", maksymalna imisja NO2 powodowana użytkowaniem nowoczesnych urządzeń grzewczych, jest niższa w przypadku spalania gazu ziemnego w kotłach nowoczesnych niż przy opalaniu węglem kamiennym "ekogroszek" prawie 5-krotnie, natomiast maksymalna imisja pyłu PM10 jest około 1283-krotnie niższa w przypadku spalania gazu ziemnego w kotłach nowoczesnych, niż podczas wykorzystywania węgla kamiennego "ekogroszek".
The article analyzes the impact of fuel type and heating device on the quality of atmospheric air in an area including 15 emitters characteristic for single-family households. The air quality analysis was conducted by calculating the concentrations of dust and gas pollutants in the atmosphere at various distances from the emitters. Dust and gas pollutants emitted as a result of heating single-family houses and heating utility water were taken into account: suspended dust PM10, sulfur dioxide, nitrogen dioxide and carbon dioxide. Eight variants of the device were used, fired with gaseous, solid and liquid fuels, in older and modern versions. The Ek100w program from Atmoterm was used to calculate the immission of pollutants. Calculations have shown that the maximum SO2 immission is 963 times lower in the case of natural gas combustion in modern boilers than when firing with "eco-pea coal", the maximum NO2 immunity caused by the use of modern heating devices is lower in the case of natural gas combustion in modern boilers than with "eco-pea coal" almost 5 times, while the maximum emission of PM10 dust is about 1283-fold lower in the case of natural gas combustion in modern boilers than when using "eco-pea" coal.
Źródło:
Inżynieria Ekologiczna; 2020, 21, 1; 17-25
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przestrzenna zmienność stężenia ditlenku siarki na obszarze Bielska-Białej
Spatial variability of sulfur dioxide concentration in Bielsko-Biala area
Autorzy:
Kozak, J.
Suryło, P.
Powiązania:
https://bibliotekanauki.pl/articles/126842.pdf
Data publikacji:
2014
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
zanieczyszczenie atmosfery
stężenie SO2
indeks jakości powietrza
Bielsko-Biała
air pollution
SO2 concentration
index of air quality
Bielsko-Biala
Opis:
Ditlenek siarki jest jednym ze wskaźnikowych gazów, które decydują o jakości powietrza atmosferycznego, zwłaszcza na obszarach aglomeracji miejskich. Pochodzi on zarówno z emisji przemysłowej, jak i ze źródeł lokalnych (tzw. niskiej emisji). Celem pracy była analiza rozkładu przestrzennego ditlenku siarki na obszarze Bielska-Białej oraz opracowanie mapy jakości powietrza z uwzględnieniem indeksu jakości powietrza dla badanego polutanta. W pracy wykorzystano materiały z przeprowadzonych w 2012 r. badań własnych, zrealizowanych w oparciu o japońską metodę Amaya-Sugiura w modyfikacji Krochmala. Materiał badawczy pochodził z ekspozycji próbników pasywnych na 30-50 stanowiskach pomiarowych, rozmieszczonych z uwzględnieniem zróżnicowanej topografii oraz form zagospodarowania terenu w granicach administracyjnych gminy Bielsko-Biała. Na podstawie miesięcznych stężeń ditlenku siarki, wahających się od 5 μg/m3 na obszarach pozamiejskich do 20 μg/m3 w centrum miasta, oraz przyjętych klas indeksu jakości powietrza opracowano mapę bonitacyjną sytuacji aerosanitarnej.
Sulphur dioxide is one of the indicator gases that affect the air quality, especially in urban areas. It comes mostly from industrial emissions as well as from local sources (so-called low emission). The aim of this study was to analyze the spatial distribution of sulfur dioxide in Bielsko-Biala area and to develop maps of the air quality taking into account the air quality index for the pollutant tested. The paper includes test results obtained by means of a Japanese method (the Amaya-Sugiura’s method) modified by Krochmal. The research material came from the exposure of passive samplers located in 30-40 measuring stands in administrative boundary of Bielsko-Biala. The samplers were distributed taking into account a diversity of topography and a land development plan. On the basis of month concentrations of sulfur dioxide ranging from 5 μg/m3 in non-urban areas to 20 μg/m3 in the city center and accepted classes of the air quality index, a bonitation map of air quality situation was made.
Źródło:
Proceedings of ECOpole; 2014, 8, 2; 535-540
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Perceived indoor air quality, air-related symptoms and ventilation in Finnish hospitals
Autorzy:
Hellgren, Ulla-Maija
Hyvärinen, Markku
Holopainen, Rauno
Reijula, Kari
Powiązania:
https://bibliotekanauki.pl/articles/2185474.pdf
Data publikacji:
2011-03-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
evaluation of ventilation
Indoor Air Questionnaire
perceived indoor air quality
Health care workers
Opis:
Objectives: Good ventilation is more important in hospitals than in many other buildings. The objective of this study was to evaluate the effect of the condition, performance and modernity of ventilation systems on the perceived indoor air quality (IAQ) and the indoor air-related symptoms of hospital personnel. Materials and Methods: An inspection and evaluation graded on a 1 to 3 scale of the condition, performance, and modernity of the ventilation systems was carried out in ten central hospitals in Finland. The perceived IAQ and the related symptoms were collected by means of an indoor air questionnaire survey among the workers in these hospitals. Results: The condition, performance and modernity of the ventilation systems were good in 40% of the hospitals included in the research and poor in another 40% of them. In hospitals where the majority of the ventilation systems were assessed to be good, the prevalence of the indoor air-related complaints and symptoms was lower than in hospitals where the majority of the ventilation systems were assessed as needing extensive repairs. Conclusions: The condition and performance of the ventilation systems in hospitals had a significant impact on the perceived IAQ and the symptoms observed among the employees in Finnish hospitals. Therefore, it is important that hospital ventilation systems are maintained properly and regularly. Furthermore, they should be renovated, at the latest when their technical lifespan expires.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2011, 24, 1; 48-56
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Towards Smart City: Influence of Air Pollution on the Local Community of the Zabrze City in Surveys and Field Research
Autorzy:
Ignac-Nowicka, J.
Powiązania:
https://bibliotekanauki.pl/articles/2065014.pdf
Data publikacji:
2018
Wydawca:
STE GROUP
Tematy:
smart city
life quality of urban residents
monitoring of air pollution
Opis:
The results of the conducted pilot research indicated the basic local problems of the residents of Zabrze city. The purpose of the next research was to answer the question: how to improve the quality of life of residents in a city with significant air pollution. Activities aimed at this goal are inscribed in the idea of "smart city". The article presents the results of pilot measurements of air pollution with toxic gases in the Zabrze city in the Silesian agglomeration (Poland). Field studies at selected locations in the city concerned measurements of nitrogen dioxide, sulphur dioxide and carbon dioxide. The aim of these studies was to identify areas of the city with significant air pollution with toxic gases in order to plan further detailed research. Made measurements showed the appearance of the local problem of accumulation of pollutants in several areas of the city. The results obtained were compared with surveys conducted among residents of the Zabrze city. The aim of the survey was to examine the respondents' awareness of: the location of areas with noticeable air pollution and health problems resulting from air pollution in the place of residence. The article also presents a plan of possible actions for the city of Zabrze within the framework of the "smart city" idea to improve the quality of life of the local city community in conditions of increased emission of gas pollution in the city.
Źródło:
Multidisciplinary Aspects of Production Engineering; 2018, 1, 1; 845--850
2545-2827
Pojawia się w:
Multidisciplinary Aspects of Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The State of Air in the European Union and Quality of Europeans’ Life
Autorzy:
Sakson-Boulet, Anna
Powiązania:
https://bibliotekanauki.pl/articles/616958.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet im. Adama Mickiewicza w Poznaniu
Tematy:
ecological security
environmental security
health security
quality of life
air quality
European Union
Opis:
This article aims to present the impact of air pollution on the quality of life of EU residents. With the aid of institutional-legal and statistical analysis an attempt has been undertaken to answer the following research questions: 1) negative concentrations whose pollution exceeds norms set out at EU levels, 2) causes of above-norm pollution concentrations and 3) impact of pollution on the health of Europeans. During the conducted research it was demonstrated that the quality of life of Europeans is being lowered by a continuing above-norm concentration of air pollution whose exposure is related to people feeling worse, numerous diseases related to the breathing system, circulation, nervous and even reproductive system as well as increased death rate and shortening of life expectancy. The estimated number of premature deaths in 2014 resulting from exposure to fine dust, ozone and carbon dioxide in the EU amounted to 487,600. As the investigation shows, the best quality of life, taking into consideration air quality, is afforded by Finland, Ireland and Sweden.
Źródło:
Przegląd Politologiczny; 2018, 4; 117-130
1426-8876
Pojawia się w:
Przegląd Politologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The association of exposure to $PM_10$ with the quality of life in adult asthma patients
Autorzy:
Ścibor, Monika
Malinowska-Cieślik, Marta
Powiązania:
https://bibliotekanauki.pl/articles/2116616.pdf
Data publikacji:
2020-04-30
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
quality of life
asthma
air pollution
environmental health
PM10
AQLQ
Opis:
ObjectivesAir pollution has become a critical environmental issue, which severely threatens the well-being of asthma patients. The quality of life of these patients, when exposed to air pollutants such as particulate matter 10 (PM10), has been poorly studied. The current research examined the association between the concentration of PM10 in the air and the quality of life of patients with asthma.Material and MethodsThe study group consisted of 300 adult asthma patients treated in 2 allergy outpatient clinics in Kraków, who declared they would not leave the city in the 14-day study period. Daily concentrations of PM10 from air monitoring stations were recorded over a period of 2 weeks, following which the patients filled out the standardized Asthma Quality of Life Questionnaire (AQLQ) regarding the monitored period to assess the total quality of life and its 4 domains (symptoms, limitation of activity, emotional functioning and environmental stimuli).ResultsThe average PM10 exposure was 65.2 μg/m3 and only 30% of the patients were exposed to values of ≤50 μg/m3, i.e., the highest 24-h threshold value considered acceptable by the World Health Organization. The observed effect of an increased level of exposure to airborne PM10 was associated with reduced scores in AQLQ from 0.40 at the medium level to 0.46 at the high level, in comparison to the low level. The total score of the asthma-related quality of life and its domains showed poorer outcomes as the concentration of PM10 was increasing (every 0.08 pt per a 10 μg/m3 increase).ConclusionsThe increase in the concentration of PM10 in the air impacts on the overall quality of life and its particular domains in people with exceptional predispositions, such as patients with bronchial asthma. Physicians taking care of asthma patients should pay special attention to the quality of patient’s life in response to the course and control of that illness, in relation to air pollution.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2020, 33, 3; 311-324
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Particulate matter air pollution in an urban area : a case study
Autorzy:
Holnicki, P.
Kałuszko, A.
Stankiewicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/406579.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
urban air quality
particulate matter
violation of concentration limit
source apportionment
Opis:
Many European agglomerations suffer from high concentrations of particulate matter (PM), which is now one of the most detrimental pollutants characterizing the urban atmospheric environment. This paper addresses the problem of PM10 pollution in the Warsaw metropolitan area, including very harmful fine fractions (PM2.5), and also some heavy metals. The analysis of air quality in the Warsaw agglomeration discussed in this study is based on results from computer modeling presented elsewhere, and refers to emission and meteorological data for the year 2012. The range of emissions considered in this analysis includes the main sectors of municipal activity: energy generation, industry, urban transport, residential sector. The trans-boundary inflow of the main pollutants coming from distant sources is also taken into account. The regional scale computer model CALPUFF was used to assess the annual mean concentrations of major pollutants in the urban area. The results show the regions where the air quality limits are exceeded and indicate the dominant sources of emission which are responsible for these vio-lations (source apportionment). These are the key data required to implement efficient regulatory actions.
Źródło:
Operations Research and Decisions; 2016, 26, 3; 43-56
2081-8858
2391-6060
Pojawia się w:
Operations Research and Decisions
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Satysfakcja klienta organizacji usługowej na przykładzie portu lotniczego
Customer satisfaction in the service organization on the example of airport
Autorzy:
Wolniak, R.
Zendla, S.
Powiązania:
https://bibliotekanauki.pl/articles/323471.pdf
Data publikacji:
2015
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
zadowolenie klienta
jakość usług
usługi lotnicze
satysfakcja
poziom jakości
customer satisfaction
quality of service
air service
satisfaction
level of quality
Opis:
Artykuł koncentruje się na kwestii analizy satysfakcji klienta organizacji usługowej. Na przykładzie portu lotniczego przeprowadzono szczegółową analizę prezentującą wyniki badań dotyczących poziomu satysfakcji klienta i określono obszary, które wymagają poprawy.
The paper focuses on the analysis of customer satisfaction in service organizations. On the example of the airport we made a detailed analysis of presenting the results of research on customer satisfaction and identify areas that need improvement.
Źródło:
Zeszyty Naukowe. Organizacja i Zarządzanie / Politechnika Śląska; 2015, 77; 291-309
1641-3466
Pojawia się w:
Zeszyty Naukowe. Organizacja i Zarządzanie / Politechnika Śląska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyniki rocznego monitoringu stężenia radonu w powietrzu budynku mieszkalnego w Łodzi na tle warunków meteorologicznych
Results of 1-year monitoring of air radon concentration in a detached house in Łódź with reference to meteorological conditions
Autorzy:
Podstawczyńska, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/578302.pdf
Data publikacji:
2016
Wydawca:
Łódzkie Towarzystwo Naukowe
Tematy:
bioklimat domu
jakość powietrza
radon
temperatura powietrza
opady
ciśnienie atmosferyczne
Łódź
bioclimate of house
air quality
air temperature
precipitation
air pressure
Opis:
W pracy dokonano analizy zmienności stężenia aktywności radonu (Rn-222) w powietrzu, rejestrowanego w trybie ciągłym, w domu jednorodzinnym w Łodzi, w okresie 356 dni, w latach 2014–2015. Tło meteorologiczne pomiarów Rn-222 stanowiły wartości temperatury powietrza w budynku i w warunkach zewnętrznych, sum godzinnych opadu atmosferycznego, ciśnienia atmosferycznego oraz typy cyrkulacji. Stwierdzono zmienność sezonową oraz dobową poziomu stężenia badanego radionuklidu w powietrzu uwarunkowaną sposobem użytkowania domu oraz czynnikami meteorologicznymi. Zamknięcie (nieużytkowanie) domu w lipcu 2014 roku spowodowało 5-krotny wzrost stężenia aktywności Rn-222 w stosunku do wartości średniej. Spadek temperatury powietrza w otoczeniu budynku wykazał słabą korel ację dodatnią, ze wzrostem stężenia aktywności Rn-222 w domu. Zmniejszenie poziomu stężenia aktywności Rn-222 w budynku obserwowano po intensywnych opadach. Ciśnienie atmosferyczne i typ cyrkulacji nie wykazywały wpływu na poziom rejestrowanego stężenia aktywności Rn-222.
The aim of the study was to investigate the variability of air Rn-222 concentration in a single-family detached house in Łódź with reference to indoor-outdoor air temperature differences, precipitation, air pressure and type of atmospheric circulation. Experiments comprising continuous, simultaneously measurements of meteorological elements and air Rn-222 concentration using AlphaGUARD® PQ2000 PRO (ionization chamber, diffusion mode) in the period from 20 May 2014 to 10 May 2015. A slightly positive correlation between Rn-222 levels and indoor-outdoor air temperature has been shown but the relationship with air pressure was not confirmed. The analysis indicated that rainfall can be an important meteorological controlling factor of air Rn-222 levels in houses located in an area with shallow groundwater.
Źródło:
Acta Geographica Lodziensia; 2016, 104; 137-146
0065-1249
Pojawia się w:
Acta Geographica Lodziensia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of point sources of pollution on air quality in Małopolska – first tests of a new version of forecasting of air pollution propagation system
Wpływ punktowych źródeł zanieczyszczeń na jakość powietrza w Małopolsce – pierwsze testy nowej wersji systemu prognozowania propagacji zanieczyszczeń powietrza
Autorzy:
Kaszowski, Kamil
Godłowska, Jolanta
Kaszowski, Wiesław
Powiązania:
https://bibliotekanauki.pl/articles/24202694.pdf
Data publikacji:
2023
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
emission of air pollution
air quality modelling
FAPPS
CALPUFF
MM5
WRF
emisja zanieczyszczeń powietrza
modelowanie jakości powietrza
Opis:
Polluted air is dangerous to human life and health. Particulate matter, among others PM10, is one of the most harmful substances. In Małopolska and its capital Kraków, the concentrations of harmful substances often exceed the standards set by the World Health Organization. Kraków, thanks to the ban on residential heating with solid fuels, has significantly reduced emissions of pollution, but they remain high in the remaining part of the region, affecting air quality in the capital as well. With the frequent occurrence of high concentrations of pollutants, in addition to the necessary measures aimed at reducing emissions, forecasting of air pollutant concentrations is needed to inform the population if normative concentrations are likely to be exceeded. The FAPPS (Forecasting of Air Pollution Propagation System), based on the AROME/MM5/CALMET/ CALPUFF model ensemble, has been operating in Małopolska since 2014 and has been used to create pollution concentration forecasts for Kraków and Małopolska. In this study, the influence of emissions from point sources on air quality in Małopolska was investigated based on the results of modelling with this system. Modelling results indicate that this influence is negligible. The quality of PM10 forecasts for four versions of the FAPPS system, differing in the meteorological model used – MM5 (Fifth-Generation Penn State/NCAR Mesoscale Model) or WRF (Weather Research and Forecasting) and the emission input (2015 emissions from the Małopolska Marshal’s Office, updated with data from the City of Kraków for 2018, or the 2020 emission inventory from the Central Emission Database) was tested. The quality of forecasts was assessed based on the results of measurements at the 22 air pollution monitoring stations for three smog episodes that occurred on 11–17.11.2021, 11–15.12.2021 and 13–18.03.2022. The best results for Kraków were obtained using an approach based on the WRF model and the emission inventory from the Central Emission Database, for which an RMSE (Root Mean Square Error) value of 30.02 µg/m3 was obtained for selected episodes. In the case of Małopolska, the lowest RMSE value (33.58 µg/m3 ) was obtained for the system using the emission inventory obtained from the Marshal’s Office and the WRF model. First tests indicate that changing the meteorological model from MM5 to WRF can lead to improved modelling results, but further research is needed to confirm it.
Zanieczyszczone powietrze jest niebezpieczne dla ludzkiego życia i zdrowia. Pyły zawieszone, wśród nich PM10, to jedne z najbardziej szkodliwych substancji. W Małopolsce i jej stolicy Krakowie stężenia szkodliwych substancji często przekraczają normy ustalone przez Światową Organizację Zdrowia. Kraków dzięki zakazowi ogrzewania mieszkań za pomocą paliw stałych ograniczył w znacznym stopniu emisję zanieczyszczeń, jednakże emisja w pozostałej części regionu jest wysoka, wpływając na jakość powietrza także w jej stolicy. W sytuacji częstego występowania wysokich stężeń zanieczyszczeń, oprócz koniecznych działań ograniczających emisje, potrzebne jest też prognozowanie wysokości stężeń zanieczyszczeń powietrza, aby informować ludność o możliwości wystąpienia przekroczeń poziomu stężeń normatywnych. W Małopolsce od 2014 r. działa system FAPPS (Forecasting of Air Pollution Propagation System) oparty o zespół modeli AROME/MM5/ CALMET/CALPUFF, który jest wykorzystywany do tworzenia prognoz stężeń zanieczyszczeń dla Krakowa i Małopolski. W niniejszej pracy na podstawie wyników modelowania tym systemem zbadano, czy emisja ze źródeł punktowych może mieć znaczący wpływ na poziom stężeń PM10 na terenie Małopolski. Wyniki modelowania wskazują, że ten wpływ jest pomijalny. W pracy testowano także jakość prognoz PM10 dla czterech wersji systemu FAPPS, różniących się zastosowanym modelem meteorologicznym – MM5 (Fifth-Generation Penn State/NCAR Mesoscale Model) lub WRF (Weather Research and Forecasting) oraz wsadem emisyjnym (emisja z 2015 r. z małopolskiego urzędu marszałkowskiego, uaktualniona o dane z Urzędu Miasta Krakowa dla 2018 r., albo inwentaryzacja emisji z 2020 r. z Centralnej Bazy Emisji). Jakość prognoz oceniano na podstawie wyników pomiarów na stacjach GIOŚ dla trzech epizodów smogowych, które miały miejsce w dniach 11–17.11.2021 r., 11–15.12.2021 r. i 13–18.03.2022 r. Najlepsze wyniki dla miasta Krakowa uzyskano, stosując podejście oparte na modelu WRF i inwentaryzacji emisji z Centralnej Bazy Emisji, dla której dla wybranych epizodów uzyskano wartość RMSE (Root Mean Square Error – średni błąd kwadratowy) równą 30,022 µg/m3 . W przypadku Małopolski najmniejszą wartość RMSE (33,579 µg/m3 ) uzyskano dla systemu używającego inwentaryzacji emisji uzyskanej z małopolskiego urzędu marszałkowskiego i modelu WRF. Pierwsze testy wskazują, że zmiana modelu meteorologicznego z MM5 na WRF może przynieść poprawę wyników modelowania, jednak konieczne są dalsze badania.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2023, 85; 59--80
0239-5223
2720-0779
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie przepływomierza powietrza z wykorzystaniem diagnoskopu FSA 720 Bosch
Examination of the air flow meter using diagnoscope FSA 720 Bosch
Autorzy:
Duer, S.
Dołgopoł, K.
Powiązania:
https://bibliotekanauki.pl/articles/309796.pdf
Data publikacji:
2016
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
przepływomierz powietrza
diagnoskop
jakość spalin
air flow meter
diagnoscope
quality of exhaust gases
Opis:
W artykule zaprezentowano problematykę badania sprawności przepływomierza powietrza i jego wpływ na jakość spalin. Przedstawiono w nim także funkcje i miejsce tego urządzenia w systemie sterowania pracą silnika. Przedstawiono także, że sygnał z tego czujnika jest informacją podstawową dla sterownika w procesie wypracowania dawki paliwa. Badanie stanu technicznego tych czujników oraz bieżące ich diagnozowanie jest podstawą do utrzymywania sygnału jakości spalin w tzw. okienku (λ). Badanie przepływomierzy powietrza jest możliwe przy wykorzystaniu specjalistycznych urządzeń diagnostycznych.
The article presents the problem of testing the efficiency of the air flow meter and its impact on the quality of exhaust gas. It presents the functions and place the device in the system motor control. Also it shows that the signal from the sensor is basic information for the driver in the process of developing fuel delivery. Examination of technical state of these sensors and their current diagnosis is the basis for maintaining the signal quality of the exhaust so. window (λ). The study flow of air is possible using specialized diagnostic equipment.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2016, 17, 6; 833-835
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies