Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "gaz obojętny" wg kryterium: Temat


Wyświetlanie 1-8 z 8
Tytuł:
Studies on the process of recovering low-temperature waste heat from a flue gas in a pilot-scale plant
Autorzy:
Szulc, P.
Tietze, T.
Wójs, K.
Powiązania:
https://bibliotekanauki.pl/articles/185836.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat recovery
condensation
inert gas
odzysk ciepła
kondensacja
gaz obojętny
Opis:
This paper presents studies carried out in a pilot-scale plant for recovery of waste heat from a flue gas which has been built in a lignite-fired power plant. The purpose of the studies was to check the operation of the heat recovery system in a pilot scale, while the purpose of the plant was recovery of waste heat from the flue gas in the form of hot water with a temperature of approx. 90 °C. The main part of the test rig was a condensing heat exchanger designed and built on the basis of laboratory tests conducted by the authors of this paper. Tests conducted on the pilot-scale plant concerned the thermal and flow parameters of the condensing heat exchanger as well as the impact of the volumetric flow rate of the flue gas and the cooling water on the heat flux recovered. Results show that the system with a condensing heat exchanger for recovery of low-temperature waste heat from the flue gas enables the recovery of much higher heat flux as compared with conventional systems without a condensing heat exchanger.
Źródło:
Chemical and Process Engineering; 2016, 37, 4; 529-543
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Separacja par 1-propanolu ze strumienia gazu obojętnego w procesie ETSA
Separation of1-propanol vapour from non-condensable gas during ETSA process
Autorzy:
Downarowicz, D.
Powiązania:
https://bibliotekanauki.pl/articles/2071195.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
desorpcja elektrotermiczna
alkohol
kondensacja
gaz obojętny
electrothermal desorption
condensation
inert gas
Opis:
Przedstawiono analizę wpływu wielkości strumienia gazu obojętnego na przebieg i efektywność wykraplania par 1-propanolu w skraplaczu wężow-nicowym. Stwierdzono, że w wężownicy skraplacza występują trzy strefy wymiany ciepła. Analizę przeprowadzono dla strumieni azotu 80-220 dm3/h i temperatury -32 to -10°C. Stwierdzono, że efektywność wymiany ciepła wzrasta wraz z obniżeniem strumienia azotu i temperatury kondensacji.
Experimental and theoretical investigations dealing with condensation of 1-propanol - nitrogen mixture inside the 4 mm ID coil condenser tube are presented in the paper. The studies were performed with nitrogen flow rate varying from 80 to 220 dm3/h. The operating temperature ranged from -32 to -10°C. The energy efficiency of VOC condensation increased with the decreasing of non-condensable gas flow rate and operating temperature.
Źródło:
Inżynieria i Aparatura Chemiczna; 2010, 3; 33-34
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena efektywności wymiany ciepła w skraplaczu wężownicowym
Experimental evaluation of coil heat exchanger effectiveness
Autorzy:
Downarowicz, D.
Gabruś, E.
Powiązania:
https://bibliotekanauki.pl/articles/2072175.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wymiennik wężownicowy
2-propanol
kondensacja
gaz obojętny
coil heat exchanger
condensation
inert gas
Opis:
W pracy przedstawiono analizę wpływu wielkości strumienia, składu i temperatury mieszaniny gazowej na efektywność cieplną skraplacza wężownicowego. Analizę przeprowadzono dla obszaru laminarnego przepływu gazu, w zakresie temperatur -30 do -10°C. Stwierdzono, że efektywność skraplacza wzrasta wraz ze wzrostem prędkości przepływu gazu oraz spadkiem temperatury. Sprawność ta jest większa, gdy mieszanina gazowa zawiera pary 2-propanolu i gdy w wężownicy zachodzi ich kondensacja.
The aim of this work was to investigate an influence of temperature, air flow rate and gas mixture composition on the effectiveness of coil heat exchanger. The studies were performed with air flow rate varying from 3 to 20 dm3/min (laminar flow range). Operating temperatures ranged from -30 to -10°C. The effectiveness increased with increasing air flow rate and decreasing operating temperature. This effectiveness was higher when gas mixture contained 2-propanol vapours condensing in the coil.
Źródło:
Inżynieria i Aparatura Chemiczna; 2013, 4; 298--299
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wtryskiwanie mikroporujące poliamidu 6.6
Microcellular injection molding for polyamide 6.6
Autorzy:
Sykutera, D.
Wajer, Ł.
Bieliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/278352.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Inżynierii Materiałów Polimerowych i Barwników
Tematy:
wtryskiwanie mikroporujące
MuCell®
poliamid
gaz obojętny
mikroporowanie
microcellular injection moulding
polyamide
inert gas
microporous
Opis:
Celem niniejszej pracy była modyfikacja struktury niewzmocnionego oraz wzmocnionego włóknem szklanym poliamidu 6.6 z litej na komórkową, poprzez mikroporowanie fizyczne z użyciem azotu w stanie nadkrytycznym metodą MuCell®. Zbadano wpływ parametrów procesu wtryskiwania mikroporującego na właściwości fizyczne otrzymanych wyprasek. Dodatkowo, za pomocą czujników ciśnienia i temperatury umieszczonych w gnieździe formy wtryskowej, zarejestrowano zmiany ciśnienia w gnieździe formy wtryskowej, podczas realizacji poszczególnych faz cyklu wtryskiwania. Uzyskane wyniki odniesiono do właściwości wyprasek wykonanych z tych samych materiałów, w warunkach standardowego wtryskiwania.
The aim of this research was to modify the solid structure of the non-reinforced and glass fiber reinforced polyamide 6.6 into the porous structure. It was obtained by physical microcellular foaming process with supercritical nitrogen in MuCell® technology. The effect of microcellular foam injection molding process parameters on the physical properties of the moulded pieces was investigated. Additionally, pressure changes inside the mould cavity were registered during each stage of the injection moulding process. Data registration was enabled by pressure and temperature sensors placed inside the mould cavity. The results were compared to the properties of moulded pieces made of the same material and obtained in the standard injection moulding process.
Źródło:
Przetwórstwo Tworzyw; 2016, T. 22, Nr 5 (173), 5 (173); 477-484
1429-0472
Pojawia się w:
Przetwórstwo Tworzyw
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aktywne metody tłumienia detonacji w mieszaninach gazowych
Active methods of detonation suppression in gaseous mixtures
Autorzy:
Porowski, R.
Zieziula, D.
Powiązania:
https://bibliotekanauki.pl/articles/136715.pdf
Data publikacji:
2017
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
detonacja
tłumienie
mgła wodna
proszek gaśniczy
gaz obojętny
detonation
suppression
water mist
dry powder
inert gas
Opis:
W artykule przedstawiono przegląd aktywnych metod tłumienia detonacji w mieszaninach gazowych. Opisane w nim zostały metody tłumienia detonacji za pomocą gazu, proszków gaśniczych oraz mgły wodnej. Pomimo znacznej poprawy w zakresie zarządzania i eksploatacji urządzeń, które przetwarzają substancje palne, wciąż istnieje potrzeba stworzenia innowacyjnych metod i środków ochrony przeciwwybuchowej. Podstawowym celem tych urządzeń jest ograniczanie potencjalnych skutków występowania zdarzeń, które mogą wywołać eksplozję. Czynnikami, które mogą się przyczyniać do zmniejszenia skutków wybuchu, są między innymi minimalizacja wystąpienia uszkodzeń i wycieków, ulepszona konstrukcja oraz poprawa procedur operacyjnych i zarządzania bezpieczeństwem w warunkach przemysłowych.
Paper presents the overview of the active methods of detonation suppression processes in reactive gaseous mixtures. In this paper the influence of the inert gas zone, dry powder and water mist on explosion processes was investigated. It was based on the literature review. Despite the significant improvements in the management and service of installations which process the materials of an explosive nature, there is still a need to create the innovative methods and measures to ensure the proper level of explosion safety. The primary purpose of such devices is to minimize the incidence of events that could potentially cause an explosion. The elements, that may contribute to reduce the effect of explosion are among others, the mitigation of explosions damages and flammable substance leaks as well as operating procedures and safety management in industrial applications.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2017, 2, 62; 83-97
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of heat transfer between an inert gas and a porous structure with ultralow thermal conductivity using the Sumudu transform method
Autorzy:
Sobamowo, Gbeminiyi
Powiązania:
https://bibliotekanauki.pl/articles/122558.pdf
Data publikacji:
2019
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
Sumudu transform method
heat transfer
inert gas
porous structure
ultralow thermal conductivity
metoda transformacji Sumudu
gaz obojętny
struktura porowata
wymiana ciepła
Opis:
The relatively new integral transform called the Sumudu transform method can be used to solve partial differential equations with variable coefficients and as well as intricate problems in engineering and applied mathematics without resorting to a new frequency domain. Unlike the other integral transforms, the Sumudu transform has scale and unit-preserving properties. However, the method is still not widely known or used for solving differential equations especially in the area of applied mathematics and engineering. As a means of demonstrating the potency of the method, the paper applied the Sumudu transform to present analytical solutions of a one-dimensional problem of heat transfer between an inert gas and an ultralow thermal conductivity porous medium. The developed analytical solutions are used to investigate the heat propagation in the porous medium. Depending on the initial temperature, it is established from the study that there are snapshots of the heat wave propagating and a sharp heat front propagation through the medium during its heating or cooling. This sharp front is difficult to detect and quantify by numerical methods. Hence, exact analytical solutions are presented in this study. As it is demonstrated in this study, it is hoped that the Sumudu transform method will be applied to other various complex engineering problems.
Źródło:
Journal of Applied Mathematics and Computational Mechanics; 2019, 18, 3; 79-87
2299-9965
Pojawia się w:
Journal of Applied Mathematics and Computational Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of heat flow in a tube bank of a condenser considering the influence of air
Autorzy:
Joachimiak, M.
Joachimiak, D.
Krzyślak, P.
Powiązania:
https://bibliotekanauki.pl/articles/240202.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
condensation
inert gas
mass share of gas noncondensing in water vapor
Dalton’s law
water vapor pressure
air partial pressure
kondensacja
gaz obojętny
Prawo Daltona
ciśnienie pary wodnej
ciśnienie parcjalne
Opis:
The pressure of wet water vapor inside a condenser has a great impact on the efficiency of thermal cycle. The value of this pressure depends on the mass share of inert gases (air). The knowledge of the spots where the air accumulates allows its effective extraction from the condenser, thus improving the conditions of condensation. The condensation of water vapor with the share of inert gas in a model tube bank of a condenser has been analyzed in this paper. The models include a static pressure loss of the water vapor/air mixture and the resultant changes in the water vapor parameters. The mass share of air in water vapor was calculated using the Dalton’s law. The model includes changes of flow and thermodynamic parameters based on the partial pressure of water vapor utilizing programmed water vapor tables. In the description of the conditions of condensation the Nusselts theory was applied. The model allows for a deterioration of the heat flow conditions resulting from the presence of air. The paper contains calculations of the water vapor flow with the initial mass share of air in the range 0.2 to 1%. The results of calculations clearly show a great impact of the share of air on the flow conditions and the deterioration of the conditions of condensation. The data obtained through the model for a given air/water vapor mixture velocity upstream of the tube bank allow for identification of the spots where the air accumulates.
Źródło:
Archives of Thermodynamics; 2017, 38, 3; 119-134
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie numerycznej mechaniki płynów CFD do modelowania zabezpieczania pomieszczeń stałymi urządzeniami gaśniczymi gazowymi
Application of Computational Fluid Dynamics CFD for Modeling of Protection of Premises by Fixed Gaseous Extinguishing System
Autorzy:
Boroń, S.
Kubica, P.
Powiązania:
https://bibliotekanauki.pl/articles/372766.pdf
Data publikacji:
2016
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
stałe urządzenie gaśnicze gazowe
gaz obojętny
czyste środki gaśnicze
czas retencji
model przepływu gazu przez pomieszczenie
numeryczna mechanika płynów CFD
fixed gaseous extinguishing system
inert gases
clean extinguishing agents
retention time
model of gas flow through the room
computational fluid dynamics CFD
Opis:
Cel: W artykule podjęto problem bezpieczeństwa pożarowego pomieszczeń chronionych instalacją stałych urządzeń gaśniczych gazowych. Zwiększenie precyzji i wiarygodności modelowania procesu gaszenia gazem gaśniczym można osiągnąć poprzez zastosowanie metod numerycznej mechaniki płynów CFD przy wykorzystaniu oprogramowania ANSYS FLUENT. Celem badań było opracowanie modelu numerycznego CFD wypływu gazu gaśniczego z przestrzeni chronionej i zbadanie z jego pomocą skuteczności gaśniczej określonych typów gazów. Projekt i metody: W artykule przedstawiono propozycję numerycznego modelu przepływu gazu gaśniczego przez pomieszczenie. Zawarto także opis badań eksperymentalnych i obliczeń analitycznych przeprowadzonych w celu jego walidacji. Wskazano na przykłady praktycznego wykorzystania opracowanego modelu CFD do symulacji, których wyniki mogą wspomagać projektowanie stałych urządzeń gaśniczych gazowych. Wyniki: Analiza porównawcza zebranych wyników symulacji pozwoliła wskazać model Standard k- ε jako model zapewniający największą zbieżność wyników z wynikami badań w skali rzeczywistej. Wartości czasu retencji uzyskane w drodze symulacji były bliższe wynikom rzeczywistym w porównaniu z wartościami otrzymanymi na podstawie obliczeń przeprowadzonych z wykorzystaniem modelu normowego. Wnioski: Modelowanie CFD umożliwia poddanie analizie mechanizmu przepływu gazu przez pomieszczenie z większą dokładnością niż dotychczas stosowane modele. Pozwala to na optymalizację doboru rodzaju oraz ilości gazu gaśniczego z uwagi na czas retencji. Dobór gazu gaśniczego o gęstości mieszaniny zbliżonej do gęstości powietrza daje możliwość uzyskania czasu retencji przekraczającego czas retencji otrzymany w przypadku zastosowania gazów wskazanych w obowiązujących normach. Zastosowanie modelowania CFD umożliwia prowadzenie badań przy wykorzystaniu przestrzeni wirtualnej, eliminując przy tym niebezpieczeństwo związane z prowadzeniem prac pomiarowych stanowiących zagrożenie dla ludzi oraz redukuje koszty finansowe związane z wyładowaniem gazu.
Aim: The problem of fire safety of areas protected by fixed gaseous extinguishing system is discussed. Increasing the accuracy and reliability of the modeling of gas extinguishing process can be achieved by using methods of computational fluid dynamics CFD using ANSYS FLUENT software. The aim of the study was to develop a numerical CFD model of extinguishing gas flow of the protected space and to examine the extinguishing effectiveness of particular type of norm gases and newly proposed extinguishing gas mixtures with a density similar to the density of air, which significantly limited the phenomenon of outflow of gas from the room and allowed to get longer retention times. Project and methods: The paper proposes a numerical model of extinguishing gas flow through the room which was developed using ANSYS Fluent program, the description of experimental researches carried out in real scale and analytical calculations based on the norm model of gas flow through the room carried out to validate the created CFD model. Examples of practical use of CFD model for simulation, results of which can provide information to support the design of fixed gaseous extinguishing systems were presented. Results: On the basis of a comparative analysis of the collected simulation results model Standard k-ε was indicated as a model that provides the greatest convergence of test results in real scale. Retention times obtained by the computer simulation were closer to real scale results than the retention times obtained on the basis of calculation using the norm wide interface model. Conslusions: The use of CFD modeling allows to review the mechanism of gas flow through the room with greater accuracy than previously used models. This allows for optimal selection of the type and amount of extinguishing gas due to the retention time. Selection of extinguishing gas with the mixture density similar to air density, makes it possible to obtain a retention time exceeding the retention time of the gases specified in the applicable standards. The use of CFD modeling allows to conduct research using virtual space, eliminating the danger related to measurement process posing a threat to humans and reduce financial costs associated with the discharge of extinguishing gas.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2016, 42, 2; 151-157
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies