Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "effective area" wg kryterium: Temat


Wyświetlanie 1-13 z 13
Tytuł:
An optimized design for non-zero dispersion shifted fiber with reduced nonlinear effects for future optical networks
Autorzy:
Raja, A S
Selvendran, S
Priya, R
Mahendran, C
Powiązania:
https://bibliotekanauki.pl/articles/173400.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
dense wavelength division multiplexing
non-zero dispersion shifted fiber
refractive index profile
effective area
dispersion slope
Opis:
Accommodation of many channels in dense wavelength division multiplexing networks raises the average power density of the optical networks. This results in severe nonlinear effects in the optical networks. An optimized design of non-zero dispersion shifted fiber with an enormous effective area can overcome this nonlinear effect and also offer a minimum bending loss and splice loss for a dense wavelength division multiplexing system. In this paper, the alpha-peak profile is utilized for calculating electrical field distribution and designing the refractive index profile of the non-zero dispersion shifted fiber. This fiber has a high effective area of about 120 μm2. Conjointly, the accomplished fiber has a very low bending loss of 1.40×10–14 dB/km and reduced splice loss of 4.46×10–3 dB. Due to this high effective area, the dense wavelength division multiplexing network performance is upgraded by diminishing nonlinear effects. In addition, the newly designed fiber has also a very low dispersion slope (0.057 ps/nm2km). Thus, the proposed fiber is optimized to handle high bandwidth and multiple high bit-rate wavelength channels without nonlinear impairments in the 1.55 μm window long-haul dense wavelength division multiplexing systems.
Źródło:
Optica Applicata; 2014, 44, 4; 503-519
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design and Analysis of Single Mode Photonic Crystal Fibers with Zero Dispersion and Ultra Low Loss
Autorzy:
Kumar, P.
Tripathy, A.
Roy, J. S.
Powiązania:
https://bibliotekanauki.pl/articles/963925.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
photonic crystal fibers
dispersion
birefringence
splice loss
confinement loss
effective mode area
Opis:
PCFs (Photonic Crystal Fibers) with ‘T’ – shaped core have been proposed in this paper. ‘T’ –shaped core PCF structures have been analyzed using two different background materials: silica and lead silicate. A total of 360° rotation at an interval of 90° has been introduced in the design of PCF structures. PCF structures A, B, C and D with rotation of 0°, 90°, 180° and 270° have silica as wafer. Similarly PCF structures E, F, G and H with similar rotation have lead silicate as background material. Numerical investigations shows structures ‘D’, ‘F’, ‘G’ and ‘H’ to have anomalous dispersion. PCF structures ‘F’, ‘G’, and ‘H’ have reported birefringence of the order of 10⁻². Besides, other PCF structures report birefringence of the order of 10⁻³. Ultra low confinement loss has been observed in all the investigated PCF structures. Moreover, splice loss observed by the structure is very low. Large mode area has been shown by all the designed PCF structures.
Źródło:
International Journal of Electronics and Telecommunications; 2018, 64, 4; 541-546
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of atmospheric precipitations on the operation of a ship’s radar
Autorzy:
Revenko, Vitaliy Yu
Powiązania:
https://bibliotekanauki.pl/articles/29521049.pdf
Data publikacji:
2023
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
ship’s radar
wavelength
precipitation intensity
radar tracking of the object
effective absorption area
effective total scattering area
specific absorption coefficient
tracking range of the object
Opis:
The effects of precipitation of varying intensity on the operation of a ship’s radar are considered. It is shown that during the propagation of the electromagnetic wave emitted by the antenna of a ship’s radar, its energy is absorbed by precipitation. To determine the power loss of an electromagnetic wave due to its absorption by particles of precipitation, the effective absorption area, specific absorption coefficient, and specific effective total scattering area are used. The effective areas of absorption and total scattering depend on the shape of the precipitation particles, their size, state of aggregation, and the length of the electromagnetic wave emitted by the antenna of the ship’s radar. The dependence of the effective absorption area on the particle size of precipitation is obtained at two wavelengths of 3 cm and 10 cm, on which the ship’s radars operate. A decrease in the tracking range of an object tracked by a ship’s radar in the case of rain falling is established compared with the tracking range of an object in clear weather. It is shown that a decrease in the tracking range of an object occurs only with moderate, strong, and very heavy rain. The attenuation of electromagnetic energy in rain with an intensity of 12.5 mm/h at a wavelength of 3 cm is obtained by calculation, which amounted to 24 dB with a length of the falling rain zone of 50 km, as well as with rain with an intensity of 100 mm/h with the same length of the precipitation zone.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2023, 73 (145); 82-89
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effective Impervious Area Mapping in Modeling Runoff from Urban Catchment
Odwzorowanie efektywnej powierzchni szczelnej w modelowaniu odpływu ze zlewni miejskiej
Autorzy:
Mazurkiewicz, Karolina
Skotnicki, Marcin
Dymaczewski, Zbysław
Powiązania:
https://bibliotekanauki.pl/articles/1811596.pdf
Data publikacji:
2020
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
effective impervious area
hydrodynamic modeling
SWMM5
urban catchment
efektywna powierzchnia szczelna
modelowanie hydrodynamiczne
zlewnia miejska
Opis:
The publication presents the results of an analysis concerning the impact of the method of an effective impervious area (EIA) mapping in the simulation model on the runoff from urban catchment. The runoff volumes and flood volumes generated by heavy rainfall, causing the runoff from pervious area, were compared. Two EIA mapping variants were taken into account – first one, concerning reduction in imperviousness degree and, second one, directing the runoff from impervious to pervious area. The runoff calculations were made on basis of simulation results in SWMM5. For building the catchment model data of existing catchment with the area of nearly 80 hectares in Bydgoszcz was used. The value of the EIA was estimated on the basis of empirical formulas. The reduction in impervious area connected directly to the storm water sewer system from 40% to 10% of the total impervious area were considered. It has been shown that using the reduction in imperviousness degree for EIA mapping can lead to underestimation of runoff volume. The difference in runoff calculated for analyzed EIA mapping variants increases with the decrease in infiltration capacity of pervious area and is in large part transformed into a flood volume.
W publikacji przedstawiono wyniki analizy wpływu sposobu wprowadzenia danych o efektywnej powierzchni szczelnej (EIA) do modelu symulacyjnego zlewni miejskiej na odpływ. Porównywano objętości odpływu oraz objętości wypływu na powierzchnię terenu generowane przez opad o znacznym natężeniu, skutkujący formowaniem spływu z powierzchni przepuszczalnych. Uwzględniono dwa warianty odwzorowania EIA – redukcję stopnia uszczelnienia i skierowanie spływu z powierzchni szczelnej na przepuszczalną. Obliczenia odpływu wykonano przy użyciu modelu symulacyjnego wykonanego w programie SWMM5. Wykorzystano dane rzeczywistej zlewni miejskiej o powierzchni blisko 80 ha znajdującej się w Bydgoszczy. Wielkość EIA oszacowano na podstawie formuł empirycznych. Rozpatrywano zmniejszenie powierzchni szczelnej podłączonej bezpośrednio do systemu kanalizacyjnego w zakresie od 10% do 40% łącznej powierzchni szczelnej (TIA). Wykazano, że wykorzystanie do odwzorowania EIA redukcji stopnia uszczelnienia może powadzić do zaniżenia objętości obliczonego odpływu. Różnica odpływu obliczonego dla analizowanych wariantów odwzorowania EIA rośnie wraz ze spadkiem zdolności infiltracyjnych powierzchni przepuszczalnych i w znacznej części jest transformowana w wypływ na powierzchnię terenu.
Źródło:
Rocznik Ochrona Środowiska; 2020, Tom 22, cz. 1; 417-430
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywna domena statku na akwenie ograniczonym i jej zastosowanie w systemach statkowych
Effective ship domain in restricted area and its use in ship systems
Autorzy:
Wielgosz, M.
Powiązania:
https://bibliotekanauki.pl/articles/253937.pdf
Data publikacji:
2015
Wydawca:
Instytut Naukowo-Wydawniczy TTS
Tematy:
domena efektywna
statek
akwen ograniczony
ECDIS
effective domain
ship
restricted area
Opis:
W artykule przedstawiono wyniki badań nad domeną efektywną statku na akwenie ograniczonym. Badania prowadzono dla statków określonych wielkości. Dane zbierano z rejestrowanych zapisów symulacji prowadzonych w laboratorium systemów ECDIS. Analizowano kształt i wielkość domeny statków określonej wielkości i prędkości. Dokonano porównania domen bezwzględnych i względnych w celu ustalenia wzajemnych zależności oraz wpływu wielkości i prędkości jednostek na kształt i wielkość domeny. Przedstawiono wyniki w poszczególnych fazach badań, wybrane wyniki końcowe oraz sformułowano wnioski.
This paper presents the research results on effective ship domain in restricted area. The research was conducted for the vessels of different sizes and speed relations. The data has been collected from the records of predefined scenarios performed in ECDIS simulator. The influence of ship length and speed on size and shape of its domain were analyzed. Absolute and relative domains were compared. The intermediate and summary results were presented and conclusions were drawn.
Źródło:
TTS Technika Transportu Szynowego; 2015, 12; 1635-1642, CD
1232-3829
2543-5728
Pojawia się w:
TTS Technika Transportu Szynowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ecological and Radiation Assessment of the State of Drilling Waste and their Disposal Products on the Example of the Khanty-Mansiysk Autonomous Okrug – Yugra
Autorzy:
Okmyanskaya, Valentina M.
Bogdanova, Olga V.
Powiązania:
https://bibliotekanauki.pl/articles/2086396.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ecological safety
environment
oil production
license area
drill cuttings
environmental assessment
radiation assessment
specific effective activity
Opis:
The development of the infrastructure of the oil and gas complex is one of the most significant factors of negative impact on the environment. The most efficient way to drill wells is cluster drilling, which currently accounts for 95% of all operations carried out in fields. In the process of oil and oil products production, toxic drilling waste is generated at the well pad, which is then placed in sludge pits (sludge storage). The aim of the study was to select the methods for drilling waste utilization based on the results of environmental radiation analysis. Within the framework of the study, the following tasks were solved: radiation monitoring of drilling waste was carried out at the “Progress-2000” spectrometric complex; analyzed the physical and chemical composition of drill cuttings; a comparative analysis of the samples under study was carried out in accordance with the normative indicators; methods of utilization of drilling waste are proposed.
Źródło:
Journal of Ecological Engineering; 2022, 23, 4; 173--180
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sub-Permian basement in the Radom-Lublin area – geological and reservoir implications based on seismic geophysical data
Podpermskie podłoże na obszarze radomsko-lubelskim – implikacje geologiczne i złożowe na podstawie sejsmicznych materiałów geofizycznych
Autorzy:
Dziewińska, Lidia
Tarkowski, Radosław
Powiązania:
https://bibliotekanauki.pl/articles/2173848.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
Radom-Lublin area
seismic profile
effective reflection coefficients
ERC
hydrocarbon reservoirs
złoża węglowodorów
obszar radomsko-lubelski
EWO
profil sejsmiczny
Opis:
This paper presents the results of an analysis of selected seismic profiles (reflection and refraction data) from the Radom-Lublin area aimed at obtaining a better understanding of geological structure and the identification of hydrocarbon deposits. To accurately reproduce the seismic reflection covering the sub-Permian formations, seismic cross sections were interpreted based on effective reflection coefficients (ERC). In interpreting the results, reference was made to the results of studies of the area using other geophysical methods. The results of these studies made it possible to obtain new information on the geology and structure of the Paleozoic complex of the Radom-Lublin area and its relationships with the basement tectonics. The structural arrangement of Carboniferous and Devonian formations as well as older Silurian, Ordovician, and Cambrian series were recognized. Selected significant tectonic and lithological discontinuities and the nature and directions of their course were characterized. Special attention was given to regional tectonic zones: the Skrzynno Fault, the Ursynów-Kazimierz fault zone and the Kock zone. The use of ERC methodology made it possible to define the boundaries of lithostratigraphic units in Carboniferous, Devonian, and older formations. The obtained results can be used to assess hydrocarbon accumulation in the area under consideration.
Artykuł prezentuje wyniki analizy wybranych profili sejsmicznych (refleksyjnych i refrakcyjnych) z obszaru radomsko-lubelskiego w celu uszczegółowienia budowy geologicznej oraz rozpoznania występowania złóż węglowodorów. W celu precyzyjnego odwzorowania danych sejsmicznych refleksyjnych obejmujących utwory podpermskie wykorzystano interpretację przekrojów sejsmicznych w wersji efektywnych współczynników odbicia EWO. W interpretacji wyników odwołano się do rezultatów badań tego obszaru z wykorzystaniem innych metod geofizycznych. Wyniki badań pozwoliły na uzyskanie nowych informacji o budowie geologiczno-strukturalnej kompleksu paleozoicznego obszaru radomsko-lubelskiego i jego związkach z tektoniką podłoża. Rozpoznano układ strukturalny utworów karbonu i dewonu oraz starszych serii syluru, ordowiku i kambru. Scharakteryzowano wybrane, istotne nieciągłości tektoniczne i litologiczne oraz charakter i kierunki ich przebiegu. Szczególną uwagę poświęcono regionalnym strefom tektonicznym: uskok Skrzynna, strefa uskokowa Ursynów-Kazimierz oraz strefa Kocka. Wykorzystanie metodyki EWO pozwoliło na prześledzenie granic wydzieleń litostratygraficznych w utworach karbonu i dewonu oraz starszych, a uzyskane wyniki mogą być pomocne dla oceny akumulacji węglowodorów na rozważanym obszarze.
Źródło:
Gospodarka Surowcami Mineralnymi; 2022, 38, 2; 207--228
0860-0953
Pojawia się w:
Gospodarka Surowcami Mineralnymi
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczenie lokalnych poziomów referencyjnych dla kończyny górnej i dolnej na podstawie operacji ortopedycznych u dzieci z użyciem ramienia C
Estimation amount of local reference dose levels upper and lower limb from intra-operative use theC-armX-ray system during orthopaedic surgical procedures among children
Autorzy:
Badziak, M.
Matera, K.
Grzelak, P.
Powiązania:
https://bibliotekanauki.pl/articles/112333.pdf
Data publikacji:
2018
Wydawca:
Indygo Zahir Media
Tematy:
dawka powierzchniowa
dawka skuteczna
fluoroskopia
operacje ortopedyczne
diagnostyczne poziomy referencyjne
DRL
dose area product
effective dose
fluoroscopy
orthopaedic surgery
Opis:
Uzasadnienie. Ważnym aspektem w ochronie radiologicznej jest zapewnienie bezpieczeństwa dzieciom w czasie operacji ortopedycznych z użyciem fluoroskopii. Ze względu na wysoką promieniowrażliwość dzieci, bardzo ważna jest kontrola dawek oraz zapewnienie im odpowiedniej ochrony radiologicznej. Cel. Celem tej pracy było oszacowanie dawki powierzchniowej oraz czasu ekspozycji z fluoroskopii wykonywanych w czasie operacji ortopedycznych dzieci oraz wyznaczenie lokalnych diagnostycznych poziomów referencyjnych na podstawie tych parametrów. Materiał i metody. W badaniu uwzględniono 501 pacjentów (mediana 11 lat), którzy przeszli operacje ortopedyczne z użyciem fluoroskopii. Pomiaru dawek dokonano w czasie zabiegów ortopedycznych celowanych na kończyny dolne i górne z użyciem mobilnego ramienia C (Ziehm-8000) pomiędzy marcem a sierpniem 2017 roku. Dawki zebrano na podstawie wskazań miernika kompatybilnego z aparatem. Wyniki. Średnia dawka powierzchniowa przypadająca na obszar kończyny górnej (73,65%) w badanej populacji wynosi 25,82 ± 58,10 cGycm2, dawka dla obszaru kończyn dolnych (26,35%) jest równa 91,07 ± 217,27 cGycm2. Lokalne poziomy referencyjne dawki w przedziałach wiekowych: 1-5, 5 ≥ 10 oraz 10 ≥ 15 i powyżej 15. roku życia wynoszą odpowiednio: 22,15, 24,76, 40,08, 55,04 cGycm2. Poziomy referencyjne czasów naświetlania w odniesieniu do podanej kolejności przedziałów są następujące: 60,75, 82,75, 124,50, 108,00 s. Wnioski. Wyniki pokazują, iż kończyny dolne otrzymują znacznie wyższe dawki niż kończyny górne w czasie operacji. Wynika to głównie z tego, że kończyny dolne mają większą objętość względem górnych. Otrzymane poziomy referencyjne układają się w tendencji wzrostowej zarówno dla DAP, jak i czasu ekspozycji. Wyjątkiem jest przedział wiekowy > 15 lat, gdzie DRL czasów ekspozycji jest niższy niż u młodszych dzieci. Podsumowanie. Na podstawie pomiaru rzeczywistych dawek powierzchniowych możliwe jest zdefiniowanie lokalnych poziomów referencyjnych. Ich określenie pozwala na kontrolowanie warunków ekspozycji w czasie operacji ortopedycznych. Ma to znaczenie zarówno dla ochrony radiologicznej pacjentów, jak i dla usystematyzowania pracy operatorów fluoroskopii, którzy mogą świadomie dobierać odpowiednie dla wieku pacjenta warunki ekspozycji.
Background. Radiological protection of the patient during fluoroscopy procedures is an important topic due to the wide scope of its use during orthopaedic surgery. Children are especially sensitive to radiation, thus it is important to control dose and ensure them special radiological protection. Objective. The aim of this study was to estimate DAP and exposure time from fluoroscopy during orthopaedic surgical procedures and to establish DRLs for these parameters. Material and methods. We involved 501 paediatric patients (median age 11) who went orthopaedic surgery with targeted fluoroscopy acquisition. The ionizing radiation was assayed using Dose Area Product Meter. This was done during orthopaedic procedures of lower and upper extremities with using mobile C-arm device (Ziehm-8000) performed between March 2017 and August 2017. Results. As the radiation dose depends on the size of the child, the children were assigned to four different age groups: 1-5, 5-10, 10-15 and > 15 years. The mean, median and third-quartile DAP and the exposure time were calculated for each group. The mean DAP for upper extremities (73.65%) was 25.82 58.10 cGcm2 and for lower extremities (26.35%) was 90.40 216.59 cGcm2. The third-quartile values were used to establish the DRLs. For this age selection the DRLs of the DAP were: 22.15, 24.76, 40.08, 55.04 cGcm2 respectively. The third-quartile the time of exposure for above mentioned age selection were as follows: 60.75, 82.75, 124.50, 108.00 s. Conclusions. The dose from fluoroscopy-guided orthopaedic surgery is higher for lower than upper extremities. It’s came from the size of a lower parts, which have larger volume than the upper parts. The DRLs of DAP and exposure time are collected with upward trend to arising age. Only the children group older than 15 years have DRLs of exposure time higher than the age group between 10-15 years. Discussion. Measurement of the dose area product in narrow group of patients allow to assessed dose reference levels. This procedure enable to control the fluoroscopy parameters during the orthopaedic surgeries. It is important both for the radiological protection of patients and to systematize the work of fluoroscopy operators, who can consciously choose age-appropriate patient exposure conditions.
Źródło:
Inżynier i Fizyk Medyczny; 2018, 7, 5; 323-327
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odnawialność wód podziemnych zlewni prawobrzeżnej Warty, Górnej Noteci i Zgłowiączki w układzie hydrodynamicznym silnie zmienionym odwodnieniami kopalnianymi
Groundwater renewal in the dynamics system of the right-bank basin of Warta, Górna Noteć and Zgłowiączka rivers strongly affected by mine dewatering
Autorzy:
Dąbrowski, S.
Rynarzewski, W.
Zachaś-Janecka, J.
Powiązania:
https://bibliotekanauki.pl/articles/2075397.pdf
Data publikacji:
2015
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
skuteczna infiltracja
odnawialność wód podziemnych
odwodnienie kopalniane
układ hydrodynamiczny
effective infiltration
renewal groundwater
renewal in mines dewatering area
recharge of groundwater flow system
Opis:
The article presents the evaluation of groundwater renewability due to effective infiltration in the hydrological system of the right-bank basin of Warta, Górna Noteć and Zgłowiączka rivers which is remarkably affected by productive lignite open mines (drainage process) as well as two closed mines (ceased dewatering process). The evaluation has been done using stationary model for groundwater circulatory system with four aquifers basing on groundwater exploitation state in 2012. The forecast of groundwater exploitation process in the next 25 years based on unsteady model for planned periods when mines will be productive and then closed indicates that effective infiltration amount is significantly overestimated for water table depression areas in the regions of open lignite mines. This results in large groundwater level increase (above ground level) in model forecast which needs to be corrected by decreasing the estimated effective infiltration amount to the average value for adjacent areas. This ostensible increase in effective infiltration amount in steady state model is the result of free and elastic groundwater resources detraction and not an actual effective infiltration increase (which was assumed so far for productive open mines areas by Sawicki, 2000 and Szczepiński, 2013).
Źródło:
Przegląd Geologiczny; 2015, 63, 10/1; 666--671
0033-2151
Pojawia się w:
Przegląd Geologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obliczenia obszaru ograniczonego użytkowania wokół pierwszej polskiej elektrowni jądrowej
Calculation of the restricted-use area around the first Polish nuclear power plant
Autorzy:
Bielewski, W.
Fornalski, K. W.
Powiązania:
https://bibliotekanauki.pl/articles/214187.pdf
Data publikacji:
2018
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
obszar ograniczonego użytkowania
formuła Sagendorfa
parametry emisji
dawka skuteczna
elektrownia jądrowa
ESBWR
restricted-use area
Sagendorf formula
emission parameters
effective dose
nuclear power plant
Opis:
Poniższy raport stanowi podsumowanie trzymiesięcznych praktyk odbytych w PGE EJ 1 Sp. z o.o. na przełomie 2014 i 2015 r., których celem było uproszczone oszacowanie promienia obszaru ograniczonego użytkowania wokół planowanej polskiej elektrowni jądrowej do celów poglądowych i edukacyjnych. Kalkulacje wymagały uwzględnienia danych meteorologicznych, parametrów emisji, a także danych o rocznej aktywności substancji promieniotwórczych uwalnianych w przypadku zaistnienia różnych sytuacji eksploatacyjnych. Podczas obliczeń rozpraszania substancji w powietrzu posłużono się modelem chmury Gaussa (uproszczeniem modelu Lagrange’a) oraz modelem dyfuzji atmosferycznej Sagendorfa. Przyjęte limity dawek oraz sposób ich szacowania zostały ustalone w zgodzie z zasadami opisanymi w art. 36f ustawy Prawo atomowe. Brak decyzji dotyczącej konkretnej technologii reaktora mającego powstać w Polsce wymusił uwzględnienie w obliczeniach różnych typów elektrowni. Obliczenia pokazały, iż brak dostępności precyzyjnych danych dotyczących parametrów emisji substancji w przypadku różnych typów awarii dla różnych reaktorów, uniemożliwia określenie dokładnego promienia obszaru ograniczonego użytkowania (głównie w warunkach awaryjnych bez stopienia rdzenia). Udowodniono jednak, jak duży wpływ na wielkość tego obszaru mają wspomniane parametry, a także określono, jaki jest w przybliżeniu charakter zmian rozkładu dawek promieniowania w przypadku zmiany każdego z nich. W warunkach normalnej eksploatacji oraz przewidywanych zdarzeń eksploatacyjnych, uwolnienia dla technologii EPR, AP1000 oraz ESBWR nie spowodowały przekroczenia progu rocznej dawki skutecznej, zdefiniowanego w Prawie atomowym jako limitujący, wymagający utworzenia obszaru ograniczonego użytkowania. Największe dawki w tych warunkach generowane są natomiast w przypadku reaktorów typu ESBWR. W warunkach awaryjnych bez stopienia rdzenia, dla pewnego zestawu założonych parametrów emisji, roczne dawki skuteczne przekraczały próg 10 mSv, wymuszając tym samym określanie obszaru ograniczonego użytkowania. Natomiast przy innym pakiecie parametrów dawki spadały poniżej tego progu. Zgodnie z obliczeniami, niezależnie od przyjętych wartości, najwyższe dawki spośród technologii ESBWR, EPR i AP1000 generowała pierwsza z nich w wyniku awarii ze zniszczeniem 1000 prętów paliwowych.
The following report is a summary of the three-month internship in PGE EJ1 at the turn of 2014 and 2015. Its purpose was to calculate, in a simplified manner, the radius of the restricted-use area around the first planned polish nuclear power plant, for the educational and illustrative purposes. The calculations required meteorological data, emission parameters and annual activities of radioactive substances released in the event of occurrence of different operational situations to be included as an input. The dispersion of substances in the air was modeled using Gaussian cloud model (Lagrange model simplification) and Sagendorf atmospheric diffusion model. The effective doses limits and methods of calculating them were determined based on art. 36f of the Polish Atomic Law. Lack of decision regarding a particular reactor technology to be introduced in Poland forced us to include various types of nuclear power plant in the simulations. The results of the calculations showed that the lack of availability of precise data on emission parameters in case of various types of emergencies for different reactors makes it impossible to determine the exact radius of the restricted-use area. Nonetheless, it has been proven that the size of this area is heavily influenced by the aforementioned parameters. Moreover, the approximate character of changes in the distribution of radiation doses in the event of a change in each of them has been determined. Under normal operating conditions and during predictable operating emergencies, releases for EPR, AP1000 and ESBWR technologies did not exceed the threshold of annual effective dose, defined in the Atomic Law as a limited one, requiring the creation of a restricted-use area. The highest doses in these conditions are generated in case of ESBWR type reactors. Under emergency conditions during which the reactor core remains safe, for a certain set of assumed emission parameters, the annual effective doses exceeded the threshold of 10 mSv, thus forcing the determination of the restricted-use area. Whereas, with a different set of parameters, the doses fell below this limit. According to calculation results, regardless of the values adopted, the highest doses among ESBWR, EPR and AP1000 technologies generated the first of them in the case of 1000 fuel rods failure.
Źródło:
Postępy Techniki Jądrowej; 2018, 2; 23-36
0551-6846
Pojawia się w:
Postępy Techniki Jądrowej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of entrance skin dose and effective dose from abdomen radiography in two diagnostic facilities in Aba, Abia State, South-East Nigeria
Autorzy:
Esu, E. O.
Chiegwu, H. U.
Omojola, A. D.
Eze, E. M.
Powiązania:
https://bibliotekanauki.pl/articles/1839405.pdf
Data publikacji:
2021
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Entrance skin dose (ESD)
Local diagnostic reference levels (LDRLs)
Dose area product (DAP)
Effective dose (E)
Absorbed dose (DT)
Thermoluminescent dosimeter (TLD)
Kilovoltage peak (kVp)
milliampere-seconds (mAs)
Opis:
Medical exposure for abdomen radiography is associated with higher doses compared to X-Rays of the chest and other extremities. The study aims to determine the mean entrance skin dose (ESD) for 104 adult patients between 20-89 years with 2 X-Ray units (A and B) in Aba, South-East Nigeria and to determine the ESD at the 75th percentile to estimate the local diagnostic reference levels (LDRLs). This study also determined the effective dose (E), the dose area product (DAP) and the relationship between absorbed dose (DT) and other parameters. This study will also compare its findings with relevant articles where necessary. The study used 2 functional floors mounted X-Ray units. A total of 208 annealed thermoluminescent dosimeters (TLDs) were used made of Lithium Fluoride, doped with Magnesium and Titanium (LiF: Mg, Ti). Two TLD chips were used per patient. The chips were positioned at the anterior and posterior end of the patient respectively for a given beam area for abdomen radiography. After exposure, a calibrated RadPro TLDcube 400 reader (Freiberg Instrument, Germany) was used to estimate individual patient doses. This was done by multiplying the TLD counts by a pre-determined calibration factor (CF). The mean/75th percentile ESD for facilities A and B was 2.92/4.12 and 3.01/3.67 mGy. The E for facilities A and B was 0.73 and 0.82 mSv respectively. There was a good relationship between the DT with ESD, exit dose (ED) and DAP for facility A, but no relationship was seen with other parameters. The mean ESD was lower compared to the National Council on Radiation Protection and Measurements (NCRP 172) and the American Association of Physicists in Medicine (AAPM) reports respectively. The study proved useful and could serve as a reference point to initiate LDRLs within the South-East zone in Nigeria for abdomen radiography.
Źródło:
World Scientific News; 2021, 161; 143-156
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of effective width of flange on calculation and reinforcement dimensioning of beam of reinforced concrete frame
Wpływ szerokości współpracującej płyty na obliczenia i wymiarowanie zbrojenia rygla ramy żelbetowej
Autorzy:
Solarczyk, Maciej Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/1403625.pdf
Data publikacji:
2021
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
reinforced concrete structures
effective width of flange
minimum cross sectional area of reinforcement
PN-EN 1992-1-1:2008
PN-B-03264:2002
konstrukcje żelbetowe
szerokość efektywna półki
minimalne pole przekroju zbrojenia rozciąganego
Opis:
The article analyses the impact of modeling the cross-section of two-nave and two-storey reinforced concrete frame with dimensions: 18.0 m × 32.0 m as a bars on the results of bending moments, the value of elastic deflection and dimensioning of reinforcement due to bending. Six options were considered: a beam as a rectangular section and five T-beam variants with different definition of effective flange width. The differences in obtained results were commented. Conclusions useful for the designing of reinforced concrete structures were presented. The procedure for determining the effective flange width in the context of PN-EN 1992-1-1:2008 and PN-B 03264:2002 standards with a commentary on the use of effective flange width in calculations and construction of reinforcement in reinforced concrete structures were described. Brief description of determining the reinforcement due to bending according to simplified method given in PN-EN 1992-1-1:2008 was presented. In addition, the standard formula for determining the minimum cross sectional area of reinforcement (9.1N) in PN-EN 1992-1-1:2008 with a proposal for its strict determination for the T-beam with a flange in the tensile zone was analyzed.
W artykule przeanalizowano wpływ modelowania przekroju rygla dwunawowej, dwukondygnacyjnej ramy żelbetowej o wymiarach: 18,0 m × 32,0 m za pomocą elementów prętowych na wyniki momentów zginających, wartość ugięcia sprężystego oraz wymiarowanie zbrojenia z uwagi na zginanie. Rozważono sześć możliwości: rygiel jako belka prostokątna oraz pięć wariantów belki teowej z różną definicją szerokości efektywnej. Skomentowano różnice w otrzymanych wynikach oraz przedstawiono wnioski przydatne do projektowania konstrukcji żelbetowych. Opisano procedurę wyznaczenia szerokości współpracującej półki przekroju teowego ze środnikiem w ujęciu norm PN-EN 1992-1-1:2008 oraz PN-B 03264:2002 wraz z komentarzem odnośnie wykorzystania szerokości efektywnej w obliczeniach i przy konstruowaniu zbrojenia w konstrukcjach żelbetowych. Przedstawiono w skrócie wyznaczenie zbrojenia z uwagi na zginanie metodą uproszczoną zgodnie z założeniami PN-EN 1992-1-1:2008. Dodatkowo analizie poddano normowy wzór na wyznaczenia minimalnego pola przekroju zbrojenia rozciąganego (9.1N) w PN-EN 1992-1-1:2008, z propozycją jego ścisłego wy-znaczenia dla przypadku przekroju teowego z półką w strefie rozciąganej.
Źródło:
Budownictwo i Architektura; 2021, 20, 2; 41-56
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary MRJ oraz badania porozymetryczne na wybranych próbkach skał z Karpat Zachodnich
NMR and mercury porosimeter measurements for the selected rock samples of the West Carpathians
Autorzy:
Jarzyna, J.
Puskarczyk, E.
Wójcik, A.
Semyrka, R.
Powiązania:
https://bibliotekanauki.pl/articles/183883.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
magnetyczny rezonans jądrowy
MRJ
stała relaksacji poprzecznej T2
porozymetria rtęciowa
porowatość efektywna
powierzchnia właściwa przestrzeni porowej
nuclear magnetic resonance (NMR)
NMR
T2 relaxation constant
mercury porosimeter
effective porosity
specific pore area
Opis:
Wykonano pomiary stałej relaksacji T2 na wybranych próbkach skał wykorzystując zjawisko magnetycznej relaksacji jądrowej dla protonów obecnych w atomach wodoru występujących w skałach. Przeprowadzono pomiary porozymetrem rtęciowym i wyznaczono krzywe kumulacyjne porowatości efektywnej oraz powierzchni właściwej, a także rozkłady geometrii porów i rozkłady powierzchni właściwej. Wykonano analizę jakościową wyników pomiarów obiema metodami dla próbek skał karbońskich i dewońskich szukając odpowiadających sobie anomalii. Następnie skorelowano wyniki obu metod w celu wyskalowania pomiarów T2 w wartościach średnic porów i rozwartościach szczelin, D. Obliczono zależność korelacyjną między T2 i D dla wszystkich próbek oraz dla wapieni dewonu górnego. Sprawdzono uzyskaną relację dla skrajnych średnic w przedziale badań porozymetrycznych.
Measurements of the T2 relaxation time were done on selected rock samples using the effect of the nuclear magnetic relaxation for protons in hydrogen atoms. Mercury porosimeter measurements were also performed to obtain cumulative curves of effective porosity and specific pore surface as well as distributions of pore geometry and specific pore surface. Qualitative analysis of results of measurements was performed with both methods on samples of Carboniferous and Devonian rocks in order to find corresponding anomalies. Next, the results of both methods were correlated to scale the T2 measurements in values of pore diameters and fracture widths, D. The correlation equations for T2 and D were calculated for the full data set and for the Upper Devonian limestone data. The result equations were tested for the extreme values of diameter in the mercury porosimeter range.
Źródło:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie; 2007, 33, 4/1; 211-235
0138-0974
Pojawia się w:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-13 z 13

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies