Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "air treatment" wg kryterium: Temat


Tytuł:
Noble metal modified TiO2 for photocatalytic air purification
Autorzy:
Klein, M.
Grabowska, E.
Zaleska, A.
Powiązania:
https://bibliotekanauki.pl/articles/109916.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
photocatalysis
noble modified TiO2
air treatment
toluene
Opis:
TiO2 was surface modified with silver, gold, palladium and platinum ion clusters to improve its photocatalytic activity. The effect of metal content and kind of dopant used during preparation procedure on the photoactivity were investigated. in toluene removal which was used as a model volatile organic compound. Toluene, at the concentration of about 100 ppm, was irradiated over noble metal modified TiO2 using light-emitting diodes (LEDs) in four subsequent cycles.
Źródło:
Physicochemical Problems of Mineral Processing; 2015, 51, 1; 49-57
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koncepcja budowy stanowiska do badania parametrów sprężonego powietrza
A concept of construction of the stand for testing compressed air parameters
Autorzy:
Perz, K.
Powiązania:
https://bibliotekanauki.pl/articles/290483.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
sprężone powietrze
uzdatnianie powietrza
optymalizacja
parametry
compressed air
air treatment
optimization
compressed air parameters
Opis:
Sprężone powietrze znalazło szerokie zastosowanie w przemyśle spożywczym. Jest bardzo często postrzegane jako tanie, a nawet darmowe, źródło energii. Nic bardziej błędnego. Liczne badania potwierdzają, że przemysł wykorzystuje tylko około 30% produkowanego sprężonego powietrza (Blaustein i Radgen, 2001) reszta jest tracona w wyniku nieszczelności, nieodpowiedniego ciśnienia przygotowanego powietrza, niewłaściwego użycia itp. Możliwości oszczędności energii w instalacjach sprężonego powietrza wiążą się przede wszystkim ze zmniejszeniem zużycia energii do napędu sprężarek, przesyłania sprężonego powietrza i sterowania systemami pneumatycznymi. Celem artykułu jest przedstawienie koncepcji budowy stanowiska do badania parametrów sprężonego powietrza. W artykule zostaną omówione podstawowe urządzenia służące do budowy takiej instalacji, ich rodzaje i zadania. W dalszej części pracy przedstawiona zostanie koncepcja zaadoptowania eksploatowanej w naszym zakładzie sieci sprężonego powietrza na potrzeby badań jego parametrów. Odpowiednie przygotowanie tego medium pod względem jakości jest w przemyśle spożywczym zadaniem priorytetowym ze względu na częsty bezpośredni jego kontakt z produktem.
Compressed air is widely applied in food industry. It is often seen as a cheap and even free energy source. However, it is not true. Numerous research prove that industry uses only approximately 30% of the produced compressed air (Blaustein, Radgen 2001) the rest is lost as a result of leak, improper pressure of the prepared air, improper use, etc. Possibilities of saving energy in installations of the compressed air are related to mainly the decrease of energy consumption for compression drive, sending compressed air and controlling pneumatic systems. The objective of the article is to present the concept of construction of the stand for testing compressed air parameters. The article will discuss the basic devices for construction of such installation, their types and tasks. A concept of adapting the compressed air net, used in our unit, for the needs of the research on its parameters. Proper preparation of this medium on account of quality is a priority task due to its frequent direct contact with a product.
Źródło:
Inżynieria Rolnicza; 2013, R. 17, nr 1, t. 1, 1, t. 1; 149-159
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usuwanie chlorowanych etenów (TCE i PCE) z powietrza w bioreaktorach zintegrowanych z unieruchomioną biomasą
Removal of chlorinated ethenes (TCE and PCE) from the air by using integrated bioreactors with immobilized biomass
Autorzy:
Tabernacka, A.
Zborowska, E.
Łebkowska, M.
Powiązania:
https://bibliotekanauki.pl/articles/236937.pdf
Data publikacji:
2012
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
bioreaktor
oczyszczanie gazów
trichloroeten
tetrachloroeten
aktywność enzymatyczna
bioreactor
air treatment
trichloroethene
tetrachloroethene
enzymatic activity
Opis:
Do oczyszczania powietrza zanieczyszczonego chlorowanymi etenami - trichloroetenem i tetrachloroetenem - zastosowano bioreaktory zintegrowane zawierające konsorcjum mikroorganizmów aktywnych w rozkładzie zanieczyszczeń oraz porowate nośniki (pianka poliuretanowa i perlit) z unieruchomioną biomasą. Jako źródło węgla dla mikro-organizmów zastosowano fenol w roztworze soli biogennych. Przez 25 d prowadzenia procesu, gdy obciążenie bioreaktorów ładunkiem zanieczyszczeń wynosiło 2,57 g/m3h (TCE) i 1,04 g/m3h (PCE), skuteczność usuwania zanieczyszczeń była bardzo wysoka - w reaktorze z biomasą unieruchomioną na perlicie wynosiła 85÷91% (TCE) i 61÷92% (PCE), natomiast w bioreaktorze z pianką odpowiednio 79÷93% i 78÷94%. Po zwiększeniu w 54. dobie pro-wadzenie procesu obciążenia bioreaktorów ładunkiem PCE do 2,73 g/m3h (przy utrzymaniu obciążenia ładunkiem TCE), zaobserwowano całkowite zahamowanie procesu oczyszczania powietrza. Okresowe doszczepianie układu bakteriami aktywnymi w rozkładzie zanieczyszczeń nie przyniosło oczekiwanych efektów. Badania wykazały także, że pianka poliuretanowa stanowiła lepszy nośnik do prowadzenia procesu biologicznego usuwania trichloroetenu i tetrachloroetenu z powietrza niż perlit, ze względu na znacznie większą liczbę bakterii aktywnych w rozkładzie zanieczyszczeń oraz aktywność enzymatyczną biomasy.
Waste air polluted with chlorinated ethenes - trichloroethene and tetrachloroethene - was treated using integrated bioreactors which contained the following: a consortium of microorganisms with the ability to degrade pollutants, and porous sorbents, polyurethane foam and perlite, with immobilized biomass. Phenol in a biogenic salt medium was used as the carbon source for microbial growth. During the first 25 days of the process, when the pollution load of the bioreactors amounted to 2.57 g/m3h (TCE) and 1.04 g/m3h (PCE), removal efficiency was very high, ranging from 85 to 91% (TCE) and from 61 to 92% (PCE) in the reactor where biomass was immobilized on perlite; in the reactor with biomass immobilized on polyurethane foam, removal efficiency varied from 79 to 93% (TCE) and from 78 to 94% (PCE). The rise in the PCE loading of the bioreactors to 2.73 g/m3h on the 54th day (while the TCE loading remained unchanged) produced significant inhibition of the air purification process. Reinoculations of the sorbents with bacteria able to degrade pollutants failed to provide the treatment effect desired. Polyurethane foam was found to be a better sorbent for biological removal of trichloroethene and tetrachloroethene from the air, which should be attributed to a noticeably greater number of bacteria active in degrading pollutants, and also to the evidently higher enzymatic activity of the biomass, as compared with perlite.
Źródło:
Ochrona Środowiska; 2012, 34, 3; 11-18
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ założonego zakresu zmienności parametrów powietrza w pomieszczeniach na całoroczne zużycie energii
The influence os assumed range of indoor air parameters on annual energy use
Autorzy:
Sowa, J.
Mijakowski, M.
Narowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/362667.pdf
Data publikacji:
2009
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
obliczenia energetyczne
system wentylacji i klimatyzacji
procesy uzdatniania powietrza
energy calculations
ventilation and air conditioning
air treatment processes
Opis:
W artykule przeanalizowano wpływ założonego zakresu zmienności temperatury powietrza i wilgotności względnej powietrza na roczne zużycie energii. W pierwszej części przedstawiono główne wymagania dotyczące parametrów powietrza w pomieszczeniach zawarte w normach polskich oraz standardach europejskich. W celu sformułowania wniosków o charakterze jakościowym jak i ilościowym przeprowadzone zostały symulacje rocznego zużycia energii w budynku biurowym o regulowanych parametrach powietrza. Do analiz stosowano model 6R1C + AHU (rozwinięty model 5R1C opisany w normie EN ISO 13790:2007 rozszerzony o moduł analizujący pracę central klimatyzacyjnych). Obliczenia przeprowadzono stosując godzinowy krok czasowy. Analizy przeprowadzono dla 3 systemów klimatyzacji ze stałym strumieniem powietrza (CAV): dwuczynnikowego systemu powietrzno-wodnego, systemu powietrznego z odzyskiem ciepła oraz systemu powietrznego z recyrkulacją.
The paper discusses the influence of assumed range of indoor air temperature and relative humidity on annual energy use. In first part basic requirements related to indoor air parameters included in Polish and European standards have been presented. In order to formulate qualitative and quantitative conclusions the set of simulations of annual energy use in office building with regulated indoor parameters has been performed. The model 6R1C +AHU (model developed on 5R1C model described in standard EN ISO 13790:2007 and extended by modules analyzing performance of air handling unit) was used for simulations. The calculations were made with 1 hour time step. Analysis were performed for 3 different air-conditioning systems with constant air volume (CAV): dual mode air-water system, all air system with heat recovery and all air system with recirculation.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2009, T. 4; 169-176
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Godzinowa metoda obliczania zapotrzebowania na energię w systemach wentylacji i klimatyzacji
Hourly method of calculation of energy consumption in air handling units
Autorzy:
Mijakowski, M.
Sowa, J.
Narowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/362828.pdf
Data publikacji:
2009
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
obliczenia energetyczne
system wentylacji i klimatyzacji
procesy uzdatniania powietrza
energetic calculation
system of ventilation and air conditioning
proces of air treatment
Opis:
W artykule przedstawiono analizę możliwości, jakie oferuje godzinowa metoda obliczania systemów wentylacji i klimatyzacji. Założenia metody oparte są na schemacie energetycznym budynku tożsamym z układem elektrycznym 6R1C (rozwinięcie schematu 5R1C z PN-EN-ISO 13790 [2]). W artykule skupiono się na obliczeniach energetycznych procesów uzdatniania powietrza. Pod uwagę wzięte zostały elementy systemu uzdatniania powietrza opisane w EN 15241 [1]: odzysk ciepła jawnego i utajonego w okresie zimowym i letnim, ogrzewanie powietrza, nawilżanie powietrza, chłodzenie z priorytetem osuszania lub ochładzania. Jako wynik otrzymuje się zużycie energii oraz wynikową wartość temperatury powietrza wewnętrznego. Pozwala to kontrolować zarówno ilość zużywanej energii i jakość analizowanego systemu utrzymania zadanych parametrów powietrza wewnętrznego.
The paper presents the concept of integration of buildings simulations and behaviour of ventilation and air-conditioning systems. Building simulation is based on simplified hourly method 6R1C developed on a base of 5R1C method described in EN ISO 13790:2007. Simulation of Air Handling Unit is based on method described in EN 15241. Integration of both methods resulted in further changes in 6R1C schema and in introduction of optional equations for assessment of indoor temperature depending on type of ventilation system. The following processes were taken into account: heat recovery (sensible and latent) during winter and summer, heating, humidifying, cooling, dehumidifying. There are both indoor temperature and energy consumption available as a results, so presented method allows controlling both energy consumption and quality of performance of HVAC.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2009, T. 4; 141-146
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ ditlenku tytanu aktywowanego światłem widzialnym na przeżywalność grzybów pleśniowych
Influence of titanium dioxide activated under visible light on survival of mold fungi
Autorzy:
Kądziołka, Daria
Rokicka, Paulina
Markowska-Szczupak, Agata
Morawski, Antoni W.
Powiązania:
https://bibliotekanauki.pl/articles/2162589.pdf
Data publikacji:
2017-12-05
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
fotokataliza
ditlenek tytanu
UV-VIS
Penicillium chrysogenum
Aspergillus niger
oczyszczanie powietrza wewnętrznego
photocatalysis
titanium dioxide
UV-Vis
indoor air treatment
Opis:
Wstęp Grzyby pleśniowe obecne w kurzu lub rozwijające się na pożywce z materiałów budowlanych są jedną z głównych przyczyn pogarszania się jakości powietrza w pomieszczeniach użytkowych i mieszkaniach. Dotychczas opracowane systemy oczyszczania powietrza nie gwarantują całkowitego usunięcia czynników szkodliwych dla zdrowia człowieka i zwierząt, dlatego szuka się rozwiązań alternatywnych. Jedno z nich polega na fotokatalizie z wykorzystaniem ditlenku tytanu (TiO2), którego przeciwgrzybowe właściwości nie zostały w pełni poznane. Celem badania była ocena wpływu TiO2 aktywowanego światłem widzialnym na przeżywalność grzybów pleśniowych. Materiał i metody W badaniach wykorzystano komercyjny ditlenek tytanu P 25 (Aeroxide P 25, prod. Evonik, Niemcy) i ditlenek tytanu modyfikowany azotem (N-TiO2). Zastosowano sztuczne światło słoneczne (UV-VIS – ultraviolet – visible spectroscopy, ultrafiolet – promieniowanie widzialne). Aktywność przeciwgrzybową fotokatalizatorów określono dla Penicillium chrysogenum i Aspergillus niger. Przeżywalność grzybów wyznaczono na podstawie zmian ich stężenia w zawiesinie. Wyniki Stwierdzono, że N-TiO2 ma lepsze właściwości biobójcze względem P. chrysogenum i A. niger niż komercyjny fotokatalizator P 25. Do pełnej eliminacji grzybów konieczne jest aktywowanie N-TiO2 sztucznym światłem słonecznym przez co najmniej 3 godz., natomiast stężenie fotokatalizatora nie może być mniejsze niż 0,01 g×dm–3 dla P. chrysogenum i 0,1 g×dm–3 dla A. niger. Wnioski Ditlenek tytanu modyfikowany azotem wykazuje dobre właściwości fotokatalityczne w świetle UV-VIS i w przyszłości może być wykorzystywany w filtrach wodnych lub oczyszczaczach powietrza do eliminacji czynników szkodliwych, w tym grzybów pleśniowych. Med. Pr. 2018;69(1):59–65
Background In public and residential buildings, fungi are usually found in the dust or growing on building materials medium such. It has been known that a number of their spores may contaminate the indoor environment and deteriorate air quality in accommodation spaces. Previously designed air cleaning systems do not guarantee a complete removal of agents harmful to humans and animals. Therefore, there is a great need to develop a new solution to remove molds from indoor air. In recent years, photocatalysis based on titanium dioxide (TiO2) has been proposed as an effective method for air pollutants removal. The aim of the study was to determine the effect of TiO2 activated under artificial sun light (UV-VIS – ultraviolet – visible spectroscopy) on survival of fungi Penicillium chrysogenum and Aspergillus niger. Material and Methods The commercial P 25 (Aeroxide P 25, Evonik, Germany) and nitrogen modified titanium dioxide (N-TiO2) were used. The microbiological study was performed using Penicillium chrysogenum and Aspergillus niger fungi. The survival of fungi was determined on the basis of changes in their concentration. Results It was found that N-TiO2 has a stronger antifungal activity against P. chrysogenum and A. niger than P 25. For N-TiO2, the complete elimination of molds was possible after 3 h under artificial solar light activation. The minimal concentration of photocatalyst was 0.01 g×dm–3 (P. chrysogenum) and 0.1 g×dm–3 (A. niger). Conclusions The nitrogen modification of titanium dioxide produced expected results and N-TiO2 presented good antifungal activity. The findings of the presented investigation can lead to the development of air filter to be used for removal of harmful agents (including molds) from indoor environment. Med Pr 2018;69(1):59–65
Źródło:
Medycyna Pracy; 2018, 69, 1; 59-65
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystywanie komputerowych symulacji przepływu w projektowaniu separatora cyklonowego dla trakcyjnych układów uzdatniania sprężonego powietrza
Using computer simulations of the flow in the design of cyclone separator for traction systems of compressed air
Autorzy:
Pałubicki, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/34585950.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Poznański Instytut Technologiczny
Tematy:
komputerowa symulacja przepływu
separator cyklonowy
układ trakcyjny
uzdatnianie sprężonego powietrza
separowanie zanieczyszczeń
computer simulation of the flow
cyclone
traction system
compressed air treatment
pollutant separator
Opis:
Większość separatorów cyklonowych stosowanych w kolejnictwie to konstrukcje przemysłowe, jedynie przystosowywane do specyficznych warunków pracy jakimi są warunki trakcyjne, które są znacznie bardziej wymagające. W niniejszym artykule przedstawiono proces projektowania separatora cyklonowego spełniającego wymagania trakcyjnych układów uzdatniania sprężonego powietrza, z wykorzystaniem programu CAD z nakładką CAE do symulacji przepływu. Projekt zrealizowano od określenia wymagań dla trakcyjnego separatora cyklonowego, przez koncepcję konstrukcji i działania, do utworzenia modeli symulacyjnych. Symulacje przeprowadzano dla różnie konfigurowanych elementów odpowiedzialnych za optymalne realizowanie funkcji separowania zanieczyszczeń. Na podstawie przeprowadzonych symulacji dla różnych wariantów konstrukcji wybrano do wykonania jedno z rozwiązań. Podjęte działania miały na celu zbudowanie prototypu, przeprowadzenie na nim badań, a następnie wdrożenie opracowanego rozwiązania do produkcji i do eksploatacji w trakcyjnych układach uzdatniania sprężonego powietrza.
More of the cyclone separators used in the railway are the industrial constructions, only adapted to the specific working conditions which are the traction conditions being much more demanding. This paper presents the design process of the cyclone separator that meets the requirements of the traction air treatment systems with using a CAD program with the CAE overlay for flow simulation. The project was realized from defining the requirements for traction cyclone separator by the concept of construction and operation to the creation of simulation models. The simulations were carried out for the different configurable elements responsible for the optimal realization of the pollutant separator function. On the basis of simulations for different variants of the structure one of the solutions to implement was chosen. The aim of actions was to build a prototype, to conduct the tests on it, and then to implement the developed solution to the production and to operation in traction systems of the compressed air treatment.
Źródło:
Rail Vehicles/Pojazdy Szynowe; 2014, 3; 55-58
0138-0370
2719-9630
Pojawia się w:
Rail Vehicles/Pojazdy Szynowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microbiological Quality of Indoor and Outdoor Air in a Municipal Wastewater Treatment Plant – A Case Study
Autorzy:
Staszowska, Amelia
Powiązania:
https://bibliotekanauki.pl/articles/2027817.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
microbial air quality
wastewater treatment plant
bioaerosol
Opis:
Wastewater treatment plants (WWTPs) have been recognized as a source of odors and microbial pathogens to the outdoor air. The results of many studies revealed that high amounts of microorganisms are not only present in the stream of wastewater or sludges but also in the bioaerosols that are generated during the different stages of the wastewater treatment. Hence, possible migration of biological contaminants into the interiors cannot be excluded. However, there is a knowledge gap in an assessment of the microbiological indoor air quality of the facilities located at WWTPs. The aim of this study was to evaluate the level of outdoor microbial air contamination upon the indoor environment based on the determined outdoor to indoor (O/I) ratios. The sampling of airborne bacteria and fungi was conducted in three replications with the sedimentation and impaction method, during a one-year survey in ten technological and office buildings as well as their vicinity, at the municipal wastewater treatment plant of Lublin (Poland). Moreover, the cleanliness of hand contact surfaces in staff rooms was examined (Rodac plates). Additionally, API identification of bacteria and fungi was carried out. The highest concentration of total bacteria count (3617 CFU/$m^3$) and fungi in bioaerosols (5386 CFU/$m^3$) was detected in the air around the sewage pumping station, close to the aeration tanks. P. fluorescens was found in the air around the grit chamber (78 CFU/$m^3$). The majority of the examined indoor air samples were characterized with different levels of microbiological contamination – from non-polluted to moderately polluted. The number of total bacteria counts ranged from 180 to 4679 CFU/$m^3$. The highest estimated indoor fungi concentration was 4022 CFU/$m^3$. The controlled surfaces were mostly contaminated with the Actinomycetes and Coliform bacteria. No Salmonella sp. were detected. The bacteria from the Enetrobacteriaceae family were commonly isolated from the indoor and outdoor air samples. The obtained data can be used to devise further guidelines facilitating control and management of WWTP to avoid or minimize the staff exposure.
Źródło:
Journal of Ecological Engineering; 2022, 23, 2; 185-190
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie flotacji ciśnieniowej w uzdatnianiu wód o zmiennej mętności
): Dissolved Air Flotation as Part of the Treatment Train for Water of Varying Turbidity
Autorzy:
Kłos, M.
Powiązania:
https://bibliotekanauki.pl/articles/236668.pdf
Data publikacji:
2003
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
flotacja ciśnieniowa
oczyszczanie wody
dissolved air flotation
water treatment
Opis:
Woda ujmowana z rzek i potoków górskich charakteryzuję się stosunkowo dobrą jakością, a jej nadmierne zanieczyszczenia pojawiają się jedynie okresowo i związane są przeważnie z występowaniem opadów atmosferycznych o dużym natężeniu i innymi zjawiskami sezonowymi, jak np. topnienie śniegu. Jednak te zazwyczaj krótkie okresy pogorszenia się jakości wody w rzekach i potokach zmuszają do budowy zakładów uzdatniania uwzględniających szeroki zakres zmian wartości niektórych wskaźników zanieczyszczeń. W pracy omówiono wyniki badań nad uzdatnianiem wody powierzchniowej ujmowanej ze zbiornika zaporowego "Wisła-Czarne" metodą koagulacji i flotacji ciśnieniowej. Badania przeprowadzone w skali ułamkowo-technicznej pozwoliły na określenie wartości parametrów technicznych i technologicznych (rodzaj i dawka reagentów, stopień recyrkulacji) poszczególnych procesów jednostkowych, dla których zastosowana metoda uzdatniania pozwala na uzyskanie najlepszych efektów usuwania zanieczyszczeń. Uzyskane rezultaty badań umożliwiły określenie podstaw systemu sterowania procesem koagulacji i flotacji w oparciu o pomiary wybranych wskaźników jakości wody.
Although most of them carry high-quality water, mountain rivers and reservoirs experience pollution episodes which follow a seasonal pattern (snow melting, heavy rains and storms), so there arises a need to design more advanced treatment plants in those regions. The study described in this paper was carried out on a pilot-plant scale with surface water samples collected from the water reservoir Wisła-Czarne treated by coagulation and dissolved air flotation. Determined were the basic parameters of the unit processes (type and dosage of reagents, extent of recirculation) with which the highest removal of particular pollutants was achieved. Based on the measured water quality parameters of choice, the fundamentals of a control system for the coagulation and flotation were determined. słowa kluczowe polskie: Flotacja ciśnieniowa, oczyszczanie wody.
Źródło:
Ochrona Środowiska; 2003, R. 25, nr 4, 4; 33-36
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena mikrobiologicznego zanieczyszczenia powietrza na terenie oczyszczalni ścieków
An assessment of microbiological air pollution at the sewage treatment plant
Autorzy:
Breza-Boruta, B.
Powiązania:
https://bibliotekanauki.pl/articles/339182.pdf
Data publikacji:
2010
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
bioaerozol
oczyszczalnia ścieków
powietrze
air
bioaerosol
sewage treatment plant
Opis:
Przeprowadzono monitoringowe badania składu bioaerozolu bakteryjnego i mikrogrzybowego na terenie Oczyszczalni Ścieków Komunalnych "Igły" w Chojnicach. Analizy mikrobiologiczne powietrza wykonano w okresie letnim 2008 r. na czterech stanowiskach: przy piaskownikach, komorach napowietrzania, w miejscu składowania dojrzewającego kompostu i 150 m poza oczyszczalnią. Ogólna liczba bakterii wynosiła 10²-104 jtk·m-³ i tylko przy piaskownikach stwierdzono silne zanieczyszczenie powietrza. Największym emitorem bakterii wskaźnikowych P. fluorescens, pałeczek Salmonella sp. oraz paciorkowców kałowych również okazały się piaskowniki. Koncentracja grzybów pleśniowych była mała (maksymalnie 4 600 jtk·m-³) i na wszystkich stanowiskach nie przekraczała wartości, wskazujących na zanieczyszczenie powietrza. W przypadku promieniowców silne skażenie powietrza odnotowano jedynie przy pryzmach kompostowych. Gronkowce, zarówno mannitolododatnie, jak i mannitoloujemne, we wszystkich punktach przyczyniły się do średniego zanieczyszczenia powietrza. Pałeczki E. coli wykryto na dwóch stanowiskach – przy piaskownikach (92,5 jtk·m-³) i komorach napowietrzania (2,5 jtk·m-³). Na podstawie wyników uzyskanych w punkcie poza obiektem stwierdzono średnie zanieczyszczenie powietrza przez promieniowce, P. fluorescens oraz gronkowce, ponadto wykryto bakterie z rodzaju Salmonella i Enterococcus, co może świadczyć o skażeniu powietrza w najbliższym otoczeniu oczyszczalni ścieków.
Monitoring of the content of bacterial and microfungal bioaerosol was carried out at the Municipal Sewage Treatment Plant "Igły" in Chojnice. Microbiological analyses of the air were carried out in the summer period 2008 at four stands: in the vicinity of sand catchers, aeration chambers, maturing compost piles and at a distance of about 150 m from the treatment plant. The total number of bacteria remained within the range of 10²-104 cfu·m-³ and heavy air pollution occurred only by sand catchers. Concentration of mould fungi reached up to 4 600 cfu·m-³, which indicated unpolluted air at all stands. Sand catchers proved to be the largest emission source of indicator bacteria P. fluorescens, Salmonella sp. and fecal streptococci. In the case of actinomycetes, a heavy air pollution was noted at compost piles. Both mannitol-positive and mannitol-negative staphylococci at all points contributed to moderate air pollution. E. coli bacilli were isolated from two stands: near sand catchers (92.5 cfu·m-³) and aeration chambers (2.5 cfu·m-³). Moderate air pollution with actinomycetes, P. fluorescens and staphylococci was found outside the sewage treatment plant. Moreover, bacteria of the genera Salmonella and Enterococcus were detected, which may evidence air pollution in the immediate vicinity of the treatment plant.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2010, 10, 3; 49-57
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ procesów oczyszczania ścieków w technologii SBR na stan sanitarny powietrza atmosferycznego
Effect of wastewater treatment processes in SBR technology on sanitary condition of atmospheric air
Autorzy:
Budzińska, K.
Traczykowski, A.
Jurek, A.
Szejniuk, B.
Michalska, M.
Berleć, K.
Powiązania:
https://bibliotekanauki.pl/articles/1818699.pdf
Data publikacji:
2013
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
oczyszczanie ścieków
stan sanitarny
powietrze atmosferyczne
sewage treatment plant
atmospheric air
Opis:
Most processes of sewage treatment contribute to the emission of microorganisms to the air, and this most frequently takes place during an intensive flow or processes of aeration. The aim of this study was to assess the effect of individual devices of the sewage treatment plant on the degree of microbiological air pollution in the premises and in the vicinity of the tested facility. The air analyses were carried out at a mechanical and biological sewage treatment plant with an increased degree of removing organic compounds in the SBR technology of on average 1786 m3 /d. In the experiment there was used the common compaction method using the sampler SAS 100. 8 research sites were appointed, including the control (background). It was found that the main source of bioaerosol emission in the studied sewage treatment plant was the decompression chamber and the Imhoff tank, and to a lesser degree, aeration chambers. For all the time of collecting samples no exceeding of permissible norms of the total number of bacteria and fungi in the air was observed. The number of staphylococci indicated that the air at all the technological facilities throughout the measurement period was moderately polluted. During all the experiment the average air pollution occurred under the influence of the presence of Pseudomonas fluorescens. The fungi species most frequently occurring in the air on the premises of the treatment plant included: Penicillium notatum, Penicillium waksmani and Penicillium viridicatum, Mucor racemosus and Cladosporium herbarum. Also Alternaria alternata occurred at all the sampling points, but this took place only in the spring period. During the conducted studies, the following species of the familyEnterobacteriaceae and other Gram-negative bacilli were determined in the air samples: Escherichia coli, Citrobacter freundii, Enterobacter cloacae, Proteus vulgaris, Serratia liquefaciens, Salmonella spp., K.pneumoniae, K.oxytoca, Yersinia enterocolitica, Vibrio, fluvialis, Pseudomonas putida, P.fluorescens and Aeromonas hydrophila. Based on the conducted assessment of air pollution on the premises of the sewage treatment plant, the occurrence of numerous microorganisms was observed. Their main emission sources were SBR reactors, bare screen stations, the Imhoff tank and the place of sludge storage. The air was assessed as moderately polluted with the bacteria Pseudomonas fluorescens, actinomyces and hemolytic staphylococci. The occurrence in the air of numerous bacteria species of the family Enterobacteriaceae poses a hazard to people employed at the sewage treatment plant.
Źródło:
Rocznik Ochrona Środowiska; 2013, Tom 15, cz. 1; 904-923
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowoczesny zespół wytwarzania i uzdatniania sprężonego powietrza dla modernizowanych EZT serii EN57
Modern unit of compressed air generation and treatment for modernized electrical traction unit of EN 57 series
Autorzy:
Pałubicki, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/34599873.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Poznański Instytut Technologiczny
Tematy:
sprężone powietrze
uzdatnianie
wytwarzanie
EZT
compressed air
treatment
production
electrical traction
Opis:
W artykule zaprezentowano najnowszy zespół wytwarzania i uzdatniania sprężonego powietrza opracowany i wykonany w Instytucie Pojazdów Szynowych „TABOR” w Poznaniu, znajdujący zastosowanie w modernizowanych ezt serii EN57. Zespół ten sterowany jest układem mikroprocesorowym. Przedstawioną konstrukcję zaprojektowano specjalnie dla zastosowań kolejowych, w związku z czym spełnia ona wszystkie, bardzo specyficzne wymagania stawiane takim układom podczas pracy w warunkach trakcyjnych. Jest to zespół kompaktowy, zawierający w sobie wszystkie niezbędne podzespoły, wymagający od użytkownika jedynie zabudowy na pojeździe, podłączenia pneumatycznego oraz dostarczenia energii elektrycznej. Możliwa jest także komunikacja zespołu z pojazdem poprzez magistralę CAN.
The article presents the latest unit of compressed air generation and treatment developed and manufactured at the Rail Vehicles Institute "TABOR" in Poznan, which applies in a series of modernized EN57 electrical traction unit. This unit is controlled by microprocessor. The present unit for producing and treatment compressed air is designed specifically for railway applications, and therefore meets all very specific requirements for these systems operating in traction conditions. It is a compact unit which contains all the necessary components, requiring from the user only fitting position on the vehicle, pneumatic connection and supply of electricity. It is also possible the communication of unit to the vehicle via the CAN bus.
Źródło:
Rail Vehicles/Pojazdy Szynowe; 2015, 2; 29-33
0138-0370
2719-9630
Pojawia się w:
Rail Vehicles/Pojazdy Szynowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania wpływu wstępnego uzdatniania wody z zastosowaniem flotacji ciśnieniowej na dawkę ozonu
Effect of DAF-aided water pretreatment on the ozone dose
Autorzy:
Sroka, M.
Powiązania:
https://bibliotekanauki.pl/articles/236390.pdf
Data publikacji:
2004
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
ozonowanie
flotacja ciśnieniowa
uzdatnianie wody
ozonation
dissolved air flotation (DAF)
water treatment
Opis:
Omówiono wyniki badań nad wpływem wstępnego uzdatniania wody z zastosowaniem flotacji ciśnieniowej (DAF) na dawkę ozonu w procesie ozonowania wstępnego. Badania przeprowadzono na stacji pilotowej Zakładu Wodociągu Północnego w Wieliszewie, który ujmuje wodę z Zalewu Zegrzyńskiego. Z przeprowadzonych badań wynika, że zastosowanie wstępnego uzdatniania wody z zastosowaniem flotacji ciśnieniowej po pierwszym stopniu koagulacji pozwoliło na 4-krotne zmniejszenie dawki ozonu wyrażonej w gO3/m3 lub prawie 2-krotne zmniejszenie dawki ozonu odniesionej do zawartości ogólnego węgla organicznego w wodzie, wyrażonej w gO3/gC. Zastosowana metoda uzdatniania wody pozwala na istotne zmniejszenie dawki ozonu, a zatem przyczyni się do ograniczenia ilości powstających ubocznych produktów utleniania zanieczyszczeń organicznych obecnych w ujmowanej wodzie, jak również pozwoli na obniżenie kosztów uzdatniania wody.
The objective of the experimental study was to find out how the pretreatment of the water involving dissolved air flotation (DAF) influences the ozone dose to be used in the preozonation process. The experiments were carried out at the pilot plant of the Warsaw Waterworks (Wodociąg Północny, Wieliszew), which draws water from the Zegrzyński impoundment lake. The results are promising. The DAF-aided pretreatment of the water after the first stage of coagulation enabled a 4fold reduction of the ozone dose expressed in gO3/m3 or an almost 2fold reduction related to the TOC content in the water and expressed in gO3/gC. With the proposed water treatment method, the ozone dose can be reduced noticeably, thus limiting the generation of by-products during oxidation of the organic pollutants that are present in the lake water. Another major benefit is the potentiality for reducing the overall water treatment cost.
Źródło:
Ochrona Środowiska; 2004, R. 26, nr 3, 3; 21-24
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Treatment strategy of allergic rhinitis in the face of modern world threats
Autorzy:
Rapiejko, Piotr
Jurkiewicz, Dariusz
Pietruszewska, Wioletta
Zielnik-Jurkiewicz, Beata
Woroń, Jarosław
Lipiec, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/1398252.pdf
Data publikacji:
2018
Wydawca:
Index Copernicus International
Tematy:
allergic rhinitis
air pollution
treatment
uncontrolled allergic rhinitis
antihistamines
dose escalation
fexofenadine
Opis:
Allergic rhinitis (AR) is the most common form of allergy, which - as epidemiological research has shown - applies to nearly 25% of the population. AR significantly affects the quality of life of the patient, and the more severe the disease, the greater the risk of developing bronchial asthma. One of the factors affecting the severity of symptoms and the degree of their control is air pollution. In some patients, despite proper treatment, persistence or only partial remission of symptoms (uncontrolled allergic rhinitis) is observed. This can lead to an increase in comorbidities - inflammation of the paranasal sinuses, otitis media and asthma - both in children and in adults. The treatment of allergic rhinitis, in accordance with the standards, consists in: education of the patient, elimination of the allergen from the environment and factors intensifying the course of the disease, selection of proper pharmacotherapy and specific allergen immunotherapy. Many factors influence the selection of the antihistamine used, e.g., the opportunity of safe increase of the dosage.
Źródło:
Polish Journal of Otolaryngology; 2018, 72, 2; 1-12
0030-6657
2300-8423
Pojawia się w:
Polish Journal of Otolaryngology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odour emission from primary settling tanks after air-tightening
Autorzy:
Friedrich, Małgorzata
Mizerna-Nowotna, Paulina
Latzke, Filip
Powiązania:
https://bibliotekanauki.pl/articles/778503.pdf
Data publikacji:
2020
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
odour emission
odour emission rate
air tightening
primary settling tank
wastewater treatment plant
Opis:
The purpose of the present article was to determine odour emission rate from primary settling tanks after hermetisation. The paper presents the results of the research on odour emission from four settling tanks, covered with self-supporting aluminium domes with a diameter of 52 meters, located on urban wastewater treatment plants, with the planned flow capacity equal to 200 000 m3/day. Altogether, the olfactometry analysis of 189 samples of polluted air pulled from the domes with the use of an air blower which has efficiency of 12 000 m3/h was conducted. The results of odour concentration measurements were in a range of approximately 10 800 to 763 600 ouE/m3. Average odour emission rate was equal to 102 ouE/(s · m2). The obtained value is much higher than the literature data, available for non-hermetised settlers only. This rate enables better estimation of the odour stream that has to be deodorised after sealing the settling tanks.
Źródło:
Polish Journal of Chemical Technology; 2020, 22, 4; 22-27
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies