Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Moura, D." wg kryterium: Autor


Wyświetlanie 1-6 z 6
Tytuł:
Confrontation Between Judicial Activism and State of Exception
Autorzy:
Moura D’Almeida,, Alexandre Pedro
Powiązania:
https://bibliotekanauki.pl/articles/1036775.pdf
Data publikacji:
2017
Wydawca:
Academicus. International Scientific Journal publishing house
Tematy:
judicial activism
state of exception
dictatorship of the judiciary
policy decision
Opis:
The judiciary has excelled in the international and national scene, reaching role of great importance, thus creating opposition to the legislative and executive powers. The center of gravity of the sovereign power of the state moves toward the judiciary, that happens to have a more active role and controlling of the others powers, but also appears as a great defender of social and fundamental rights causes, seeking to make an effective constitution. Its great public notoriety has attracted great distrust of various sectors of society, especially by the two powers that have an increasing interference. Arises, therefore, a speech that the judiciary would be reversing into a big and uncontrollable power, increasing the suspicion that now it would be living in a real dictatorship of the judiciary through judicial activism. There is a growing concern with the expansion of activism and the role of the judiciary. The purpose of this work is to conceptualize and approach the judicial activism and the state of exception to search and reveal if there is any similarity, to then draw up a possible answer to the concern of forming a dictatorship of the judiciary. The state of exception is one of the rule of law paradoxes, while activism is a political manifestation of the judiciary. The similarity between the institutes appears as appalling in a dynamic expansion of political power of a state institution exercising judicial function, putting in check who would be the sovereign in a rule of law and democratic state.
Źródło:
Academicus International Scientific Journal; 2017, 15; 28-46
2079-3715
2309-1088
Pojawia się w:
Academicus International Scientific Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikrokonkrecje syderytowe w holoceńskich osadach ujścia rzeki Gwadiana w Portugalii : raport wstępny
Micro-scale sideritic concretions in Holocene sediments in the Guadiana estuary, Portugal : a preliminary report
Autorzy:
Wilamowski, A.
Boski, T.
Moura, D.
Powiązania:
https://bibliotekanauki.pl/articles/2075017.pdf
Data publikacji:
2013
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
siderite
concretions
estuarine sediment
Guadiana River
Holocene
syderyt
konkrecje
sedymentacja osadów
rzeka Gwadiana
holocen
Opis:
The authors described micro-scale carbonate concretions occurring at a depth of about 41 m within Holocene sandy sediments filling the Guadiana River paleovalley, representing the transitional fluvial- -estuarine facies. Despite their minute sizes, the micro-concretions show a complex internal structure. Regular distribution of Mg, Mn and Ca can be assigned to a chemical zoning, pointing to precipitation under varying chemical conditions. Based on morphological and chemical peculiarities, four types of concretions can be distinguished. Detrital Fe-Mg-carbonates form nuclei. At first, Mn-rich carbonate precipitated as a coating, which is coherent with the sequence of precipitation of carbonates associated with bacteria-mediated oxidation of organic matter. Subsequently, the main bodies of concretions precipitated as Fe-carbonate (siderite). The last precipitation episode is marked by enrichment in Ca. The XRD patterns show the presence of a mixture of discrete carbonate phases.
Źródło:
Przegląd Geologiczny; 2013, 61, 10; 568--575
0033-2151
Pojawia się w:
Przegląd Geologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tubing decontamination during the leak test of iodine-125 seeds
Autorzy:
Moura, J. A.
Moura, E. S.
Sprenger, F. E.
Nagatomi, H. R.
Zeituni, C. A.
Feher, A.
Manzoli, J. E.
Souza, C. D.
Rostelato, M. E.
Powiązania:
https://bibliotekanauki.pl/articles/148765.pdf
Data publikacji:
2010
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
brachytherapy
iodine seeds
leak test
sealed radioactive sources
Opis:
Leak tests were made to detect any leakage of radioactive material from inside the iodine-125 seeds applied in brachytherapy. These seeds are used in prostate cancer treatment. In the quality control routine, during seed production, leak tests are performed according to the International Standard Organization – radiation protection – sealed radioactive sources – ISO-9978 standard, and require liquid transfer between recipients. Any leakage causes contamination of the liquid and tubes. The aim of this study is the establishment of decontamination routines for tubes, allowing their repeated use, in the automated assay process.
Źródło:
Nukleonika; 2010, 55, 3; 409-413
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Extended warranty of medical equipment subject to imperfect repairs: an approach based on generalized renewal process and Stackelberg game
Rozszerzona gwarancja na sprzęt medyczny podlegający niepełnym naprawom: podejście oparte na uogólnionym procesie odnowy i modelu Stackelberga
Autorzy:
de Santana, J. M. M.
Santiago, R. L. V.
Moura, M das C.
Lins, I. D.
Powiązania:
https://bibliotekanauki.pl/articles/301400.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
medical equipment
extended warranty
Stackelberg game
generalized renewal process
sprzęt medyczny
rozszerzona gwarancja
gra Stackelberga
uogólniony proces odnowy
Opis:
Due to its advanced technology, maintenance services of healthcare equipment have been commonly executed by the original equipment manufacturer (OEM), which can be characterized as a monopolist. In this context, hospitals require high availability of their equipment at a reasonable servicing cost, whereas OEM aims to maximize its profit by selling extended warranty (EW) services for multiple consumers. The issue of drawing a maintenance contract between OEM and hospitals has already been treated by adopting a Stackelberg’s game. However, the “as good as new” and “as bad as old” assumptions are usually considered, which are rather difficult to observe in practice, especially for healthcare institutions and their technology-intensive equipment. Thus, we here adopt generalized renewal processes (GRP) for modelling imperfect repairs, and we develop a discrete event simulation method for finding the best strategies of each player: OEM sets the prices for EW and on-demand maintenance that optimize its profit, while hospitals choose which option they should hire. We also present an application example with real data gathered from an angiography device, which is used for mapping blood vessels and diagnosing heart diseases.
Ze względu na zaawansowanie technologiczne sprzętu medycznego, jego obsługą serwisową zazwyczaj zajmuje się producent sprzętu oryginalnego (OEM), co czyni go monopolistą w tym zakresie. Podczas gdy szpitalom zależy na wysokiej gotowości sprzętu przy rozsądnych kosztach obsługi, OEM dąży do maksymalizacji zysku poprzez sprzedaż rozszerzonej gwarancji na usługi serwisowe wielu klientom. Istnieją już badania, w których kwestię zawierania umowy o świadczenie usług serwisowych między OEM a szpitalami analizowano z zastosowaniem modelu Stackelberga. Jednak zwykle badania te zakładają, że stan po naprawie może być albo "jak fabrycznie nowy" albo"jak przed uszkodzeniem", co rzadko spotyka się w praktyce, zwłaszcza w przypadku placówek służby zdrowia i ich zaawansowanego technologicznie sprzętu. W związku z tym, w przedstawionej pracy, przyjęto uogólniony proces odnowy (GRP) do modelowania niepełnych napraw oraz opracowano metodę symulacji zdarzeń dyskretnych w celu znalezienia najlepszych strategii dla każdego gracza: OEM ustala ceny rozszerzonej gwarancji oraz konserwacji na żądanie, tak by zoptymalizować swój zysk; szpital natomiast ustala, którą opcję powinien wybrać. W pracy przedstawiono również przykład zastosowania omawianego podejścia z wykorzystaniem rzeczywistych danych zebranych z angiografu, który służy do obrazowania naczyń krwionośnych i diagnozowania chorób serca.
Źródło:
Eksploatacja i Niezawodność; 2018, 20, 4; 567-578
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Leakage test evaluation used for qualification of iodine-125 seeds sealing
Autorzy:
Feher, A.
Rostelato, M. E. C. M.
Zeituni, C. A.
Calvo, W. A. P.
Somessari, S. L.
Moura, J. A.
Moura, E. S.
Souza, C. D.
Rela, P. R.
Powiązania:
https://bibliotekanauki.pl/articles/147662.pdf
Data publikacji:
2011
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
leakage test
iodine-125 seeds
prostate cancer
brachytherapy
titanium tube
standard ISO-9978
Opis:
Brachytherapy is one of the possible treatments with ionizing radiation available for prostate cancer, in which small seeds containing iodine-125 radioisotope are implanted directly into the prostate. The seed consists of a sealed titanium tube containing a central silver wire with adsorbed iodine-125. The tube sealing is made with titanium at the ends, using plasma arc-welding (PAW) or laser process. This sealing must be leakage-resistant and free of cracks, therefore avoiding iodine-125 to deposit in the silver wire to escape and spread into the human body. To ensure that this problem is not occurring, rigorous leakage tests in accordance with the standard ISO-9978 should be applied. The aim of this study is to determine, implement and evaluate the leakage test to be used in the iodine-125 seeds production, in order to qualify the sealing procedure. The standard ISO-9978 presents a list of tests to be carried out according to the type of source. The preferential methods for brachytherapy sources are soaking and helium. To assess the seeds leakage, the method of immersion test at room temperature was applied. The seeds are considered leakage-free if the detected activity does not exceed 185 Bq (5 nCi). An iodine standard was prepared and its value determined in a sodium iodide detector. A liquid scintillation counter was calibrated with the standard for seed leakage tests. Forty-eight seeds were plasma arc-welded for these tests.
Źródło:
Nukleonika; 2011, 56, 4; 375-379
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A study about the measurement method of the homogeneity of radioactivity along an iridium-192 wire used in brachytherapy
Autorzy:
Costa, O. L.
Calvo, W. A. P.
Zeituni, C. A.
Rostelato, M. E. C. M.
Moura, J. A.
Feher, A.
Souza, C. D.
Somessari, S. L.
Powiązania:
https://bibliotekanauki.pl/articles/148238.pdf
Data publikacji:
2014
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
iridium-192
iridium wire
low dose rate brachytherapy
quality control
cancer treatment
radioactive sources production
Opis:
The Nuclear and Energy Research Institute has produced, since 1998, iridium-192 wires used in low dose rate brachytherapy. In the paper the authors studied the influence of wire profile on the homogeneity distribution of radioactivity of iridium-192 along the wire. The authors propose the improvements in the quality control procedure that will provide more accurate measurement data and suggest changes in control devices.
Źródło:
Nukleonika; 2014, 59, 1; 37-39
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies