Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Grelik, A." wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
Development and validation of an analytical method for determination of ergot alkaloids in animal feedingstuffs with high performance liquid chromatography - fluorescence detection
Autorzy:
Kowalczyk, E.
Patyra, E.
Grelik, A.
Kwiatek, K.
Powiązania:
https://bibliotekanauki.pl/articles/31456.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Opis:
A high performance liquid chromatography combined with fluorescence detection (HPLC-FLD) method was developed for determination of five ergot alkaloids (EA): ergometrine, ergotamine, ergocornine, ergocrypine and ergocristine in animal feedingstuffs. The method was based on the application of QuEChERS salts for extraction and modified QuEChERS dispersive SPE for the cleanup step. Alkaloids separation was performed on a C18, 250 mm x 4.6 mm, 5 μm column with the mobile phase containing ammonium carbonate and acetonitrile. The excitation and emission wavelengths were 330 and 420 nm respectively. The method was validated according to the Commission Decision 2002/657/EC and all parameters are in agreement with the requirements of the Decision. Linearity was determined for the concentration range of 25-400 μg/kg. The coefficient of determination (R2) for all curves was from 0.985 to 0.996. The limit of detection (LOD) was in the range 3.23 to 6.53 μg/kg and the limit of quantification (LOQ) from 11.78 to 13.06 μg/kg. The decision limit (CCα) ranged from 29.56 to 43.08 μg/kg and detection capability (CCβ) from 40.65 to 51.01 μg/kg. The highest coefficient of variation (CV) for repeatability was 14.3% and for reproducibility 15.4%.
Źródło:
Polish Journal of Veterinary Sciences; 2016, 19, 3
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Screening method for the determination of tetracyclines and fluoroquinolones in animal drinking water by liquid chromatography with diode array detector
Autorzy:
Patyra, E.
Kowalczyk, E.
Grelik, A.
Przenioslo-Siwczynska, M.
Kwiatek, K.
Powiązania:
https://bibliotekanauki.pl/articles/31196.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Opis:
A liquid chromatography - diode array detector (HPLC-DAD) procedure has been developed for the determination of oxytetracycline (OTC), tetracycline (TC), chlorotetracycline (CTC), doxycyc-line (DC), enrofloxacin (ENR), ciprofloxacin (CIP), sarafloxacin (SAR) and flumequine (FLU) residues in animal drinking water. This method was applied to animal drinking water. Solid-phase extraction (SPE) clean-up on an Oasis HLB cartridge allowed an extract suitable for liquid chromatographic analysis to be obtained. Chromatographic separation was carried out on a C18 analytical column, using gradient elution with 0.1% trifluoroacetic acid - acetonitrile - methanol at 30oC. The flow-rate was 0.7 mL/min and the eluate was analysed at 330 nm. The whole procedure was evaluated according to the requirements of the Commission Decision 2002/657/EC, determining specificity, decision limit (CCa), detection capacity (CCß), limit of detection (LOD), limit of quantification (LOQ), precision and accuracy during validation of the method. The recoveries of TCs and FQs from spiked samples at the levels of 10, 100 and 1000 ^g/L were higher than 82%. The developed method based on HPLC-DAD has been applied for the determination of four tetracyclines and four fluoroquinolones in animal drinking water samples.
Źródło:
Polish Journal of Veterinary Sciences; 2015, 18, 2
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurements of doses from photon beam irradiation and scattered neutrons in an anthropomorphic phantom model of prostate cancer: a comparison between 3DCRT, IMRT and tomotherapy
Autorzy:
Kowalik, A.
Jackowiak, W.
Malicki, J.
Skórska, M.
Adamczyk, M.
Konstanty, E.
Piotrowski, T.
Polaczek-Grelik, K.
Powiązania:
https://bibliotekanauki.pl/articles/146348.pdf
Data publikacji:
2017
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
3DCRT
IMRT
low doses
neutron doses
thermoluminescent detectors (TLD)
tomotherapy
Opis:
The rapid development of new radiotherapy technologies, such as intensity modulated radiotherapy (IMRT) or tomotherapy, has resulted in the capacity to deliver a more homogenous dose in the target. However, the higher doses associated with these techniques are a reason for concern because they may increase the dose outside the target. In the present study, we compared 3DCRT, IMRT and tomotherapy to assess the doses to organs at risk (OARs) resulting from photon beam irradiation and scattered neutrons. Material and methods. The doses to OARs outside the target were measured in an anthropomorphic Alderson phantom using thermoluminescence detectors (TLD 100) 6Li (7.5%) and 7Li (92.5%). The neutron fluence rate [cm–2·s–1] at chosen points inside the phantom was measured with gold foils (0.5 cm diameter, mean surface density of 0.108 g/cm3). Results. The doses [Gy] delivered to the OARs for 3DCRT, IMRT and tomotherapy respectively, were as follows: thyroid gland (0.62 ± 0.001 vs. 2.88 ± 0.004 vs. 0.58 ± 0.003); lung (0.99 ± 0.003 vs. 4.78 ± 0.006 vs. 0.67 ± 0.003); bladder (80.61 ± 0.054 vs. 53.75 ± 0.070 vs. 34.71 ± 0.059); and testes (4.38 ± 0.017 vs. 6.48 ± 0.013 vs. 4.39 ± 0.020). The neutron dose from 20 MV X-ray beam accounted for 0.5% of the therapeutic dose prescribed in the PTV. The further from the field edge the higher the contribution of this secondary radiation dose (from 8% to ~45%). Conclusion. For tomotherapy, all OARs outside the therapeutic field are well-spared. In contrast, IMRT achieved better sparing than 3DCRT only in the bladder. The photoneutron dose from the use of high-energy X-ray beam constituted a notable portion (0.5%) of the therapeutic dose prescribed to the PTV.
Źródło:
Nukleonika; 2017, 62, 1; 29-35
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies