Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Dudziak, Mariusz" wg kryterium: Autor


Wyświetlanie 1-9 z 9
Tytuł:
Evaluation of the Effectiveness of the Coagulation Process in the Treatment of Wastewater from the Foundry Industry
Autorzy:
Dawczak, Paulina
Dudziak, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/123257.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
foundry industry
wastewater treatment
coagulation
Opis:
The wastewater from the foundry industry contains both inorganic and organic pollutants. Their characteristic feature is the variability of the composition, which depends on the intensity of production in a given industrial plant or the combination of various pollutant streams. As part of the paper, the coagulation process was proposed for the treatment of selected wastewater from the foundry industry. The purpose of the research was to evaluate the effectiveness of coagulation depending on the concentration of pollutants in wastewater.
Źródło:
Journal of Ecological Engineering; 2019, 20, 6; 174-176
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie procesu Fentona w oczyszczaniu ścieków z przemysłu odlewniczego
Application of the Fenton process in the treatment of wastewater from the foundry industry
Autorzy:
Dawczak, Paulina
Dudziak, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/126324.pdf
Data publikacji:
2020
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
przemysł odlewniczy
oczyszczanie ścieków
proces Fentona
foundry industry
wastewater treatment
Fenton process
Opis:
Celem pracy była ocena skuteczności procesu Fentona w oczyszczaniu wybranych ścieków z przemysłu odlewniczego, które wstępnie poddano koagulacji. W procesie koagulacji wydzielono ze ścieków zanieczyszczenia występujące zarówno w fazie zawieszonej, jak i koloidalnej. Dobór korzystnego przebiegu procesu Fentona prowadzono pod względem następujących parametrów: pH ścieków, dawki nadtlenku wodoru, stosunku masowego Fe2+/H2O2 oraz czasu procesu. Dobrane parametry procesu Fentona wynosiły odpowiednio: pH ścieków 2,5, dawka nadtlenku wodoru 5,00 g/dm3, stosunek masowy Fe2+/H2O2 = 0,3 oraz czas procesu 120 min. Dla podanych parametrów wykazano wysoką skuteczność procesu Fentona w obniżeniu chemicznego zapotrzebowania tlenu (ChZT) badanych ścieków z przemysłu odlewniczego. W ściekach obniżyło się również stężenie niejonowych substancji powierzchniowo czynnych (NSPC).
The aim of the study was to evaluate the effectiveness of the Fenton process in the treatment of selected wastewater from the foundry industry, which was initially coagulated. In the coagulation process, contaminants found in the suspended and colloidal phase were separated from the wastewater. The selection of the favorable course of the Fenton process was carried out with the following parameters in mind: wastewater pH, hydrogen peroxide dose, Fe2+/H2O2 mass ratio and process time. The selected parameters of the Fenton process were: wastewater pH = 2.5, hydrogen peroxide dose 5.00 g/dm3, Fe2+/H2O2 mass ratio = 0.3 and process time 120 min. For the given parameters, high efficiency of the Fenton process in lowering the chemical oxygen demand (COD) of the treated wastewater from the foundry industry was demonstrated. In wastewater, the concentration of non-ionic surfactants (NSPC) also decreased.
Źródło:
Proceedings of ECOpole; 2020, 14, 1; 79-87
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie procesu ultrafiltracji do podczyszczania wód opadowych
Application of the ultrafiltration process to pretreat rainwater
Autorzy:
Marszałek, Anna
Dudziak, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/127439.pdf
Data publikacji:
2020
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
wody opadowe
ultrafiltracja
techniki membranowe
rainwater
ultrafiltration
membrane techniques
Opis:
Celem badań była ocena możliwości zastosowania procesu ultrafiltracji do oczyszczenia wybranych wód opadowych pochodzących z dachu domku jednorodzinnego z miasta Wodzisław Śląski. Proces membranowy prowadzono w komorze ciśnieniowej amerykańskiej firmy Osmonics typu GH-100-400 o pojemności 350 cm3 zaopatrzonej w mieszadło magnetyczne zapewniającej warunki dead-end. W badaniach zastosowano cztery płaskie membrany ultrafiltracyjne o symbolach MT, ST, V3 i BN różniące się materiałem membranotwórczym i graniczną masą molową (MWCO). W trakcie filtracji ciśnieniowej wyznaczono zależność objętościowego strumienia permeatu od czasu prowadzenia procesu. Określono również właściwości transportowe stosowanych membran dla wody zdejonizowanej, grubość membrany oraz kąt zwilżalności. Efektywność procesu oceniano również w oparciu o zmianę ładunku zanieczyszczeń organicznych, takich jak ChZT, OWO, OW, NW, barwę oraz absorbancję UV254. Na podstawie otrzymanych wyników badań można stwierdzić, że najlepszą membraną pod względem własności transportowych była membrana ST wykonana z polieterosulfonu (10 kDA), chociaż w przypadku tej membrany zjawiska foulingu było najbardziej intensywne. Uzyskano również wysokie usunięcie zanieczyszczeń organicznych oraz barwy wód opadowych.
The aim of the study was to assess the applicability of the ultrafiltration process for the treatment of selected rainwater from the roof of a detached house in the city of Wodzislaw Slaski. The membrane process was carried out in a pressure chamber produced by Osmonics, an American company, type GH-100-400 with a capacity of 350 cm3 equipped with a magnetic stirrer providing dead-end conditions. Four flat ultrafiltration membranes with PT, PW, V3, BN symbols and of different membrane material and MWCO were used. During the pressure filtration, the relationship between the volumetric permeate flux and the time of the process was determined. The transport properties of the applied membranes for deionized water, membrane thickness and the angle of wettability were also determined. The effectiveness of the process was also evaluated based on the change in organic pollutants load, i.e. COD, TOC, TC, IC, colour and absorbance in UV254. Based on the obtained test results, it was found that the best membrane in terms of transport properties was the PES membrane (cut-off 10 kDa). However, in the case of this membrane, the phenomenon of fouling was the most intense. It was also obtained high removal of organic impurities and rainwater colour.
Źródło:
Proceedings of ECOpole; 2020, 14, 1; 107-114
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przemiany farmaceutyków w wodzie basenowej
Transformations of pharmaceuticals in swimming pool water
Autorzy:
Lempart, Anna
Kudlek, Edyta
Dudziak, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/126072.pdf
Data publikacji:
2019
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
instalacje basenowe
kofeina
mikrozanieczyszczenia
naturalna degradacja
swimming pools
caffeine
micropollutants
natural degradation
Opis:
Woda basenowa stanowi mieszaninę substancji o wciąż nie do końca poznanym składzie. Do basenów wprowadzane są różne zanieczyszczenia i substancje chemiczne, które mogą wchodzić w interakcje ze sobą lub przechodzić wiele przemian w instalacji oczyszczania, co należy uznać za potencjalne zagrożenie dla zdrowia pływaków. Niniejsza praca stanowi wstęp do badań mających na celu określenie ścieżek transformacji mikrozanieczyszczeń organicznych w systemach oczyszczania wody basenowej, a tym samym zrozumienie przemian fizycznych oraz reakcji chemicznych, którym ulegają różne związki występujące w basenach. Badania przeprowadzono na przykładzie kofeiny, która jest związkiem farmaceutycznym z grupy stymulantów. Jej obecność w wodzie basenowej wykazały liczne badania prowadzone na całym świecie, w tym w Polsce. W badaniach oceniono stopień naturalnej degradacji tego związku pod wpływem działania światła słonecznego. Analizę stężenia związku i identyfikację jego produktów przemian wykonano z wykorzystaniem metody chromatografii gazowej. Wykazano, że kofeina ulega naturalnemu procesowi degradacji w środowisku wodnym w różnym stopniu, w zależności od warunków prowadzenia procesu i składu fizykochemicznego matrycy wodnej. Obecność związków organicznych i nieorganicznych miała niekorzystny wpływ na degradację kofeiny.
Swimming pool water is a mixture of chemical substances with a composition that has not been completely recognized until now. Various pollutants and chemical contaminants are entering the pool basin. They may interact with each other or undergo numerous changes in the pool installation what should be considered as a potential threat to the health of swimmers. This work is a preliminary study to determine the transformation path of small-molecule organic micropollutants in swimming pool water treatment systems and thus to understand the physical changes and chemical reactions of various compounds that may occur in these systems. This study was carried out on the example of caffeine, which is a pharmaceutical compound from the group of stimulants. Its presence in pool water has been reported by numerous studies conducted all over the world, including Poland. In the presented study, the focus was on checking the natural degradation of this compound under the influence of sunlight determined using the gas chromatography method. It was shown that caffeine undergoes a natural degradation process in the water environment to varying degrees depending on the process conditions and the physico-chemical composition of the water matrix. The presence of organic and inorganic compounds had an adverse effect on the degradation of caffeine.
Źródło:
Proceedings of ECOpole; 2019, 13, 1-2; 127-134
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Removal of PAHs from road drainage system by ultrasonication
Autorzy:
Copik, Jakub
Kudlek, Edyta
Dudziak, Mariusz
Powiązania:
https://bibliotekanauki.pl/chapters/31233771.pdf
Data publikacji:
2021
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
road drainage
polycyclic aromatic hydrocarbons
ultrasound
water treatment
advanced oxidation processes
Opis:
Polycyclic aromatic hydrocarbons (PAHs) due to natural and anthropogenic processes are widely spread substances in the environment. It was proved that some of these pollutants can cause serious humans health problems such as hemolytic anemia, liver, cataracts and retina damage, neurological diseases, and primarily some PAHs are cancerogenic. These substances are hardly removable biologically so modern techniques such as ultrasonication should be developed. The articles reveal the removal effectiveness of 7 polycyclic aromatic hydrocarbons (PAHs) which were recognized in water from highway drainage system by using the ultrasound treatment process. Results showed that after 45 min of sonication, the average removal of PAHs reached 59%. The reduction of analyzed substances was proportional to treated time and irradiation amplitude. Furthermore, because of ozone addition to the sonicated samples, the efficiency of the treatment was significantly higher. The average PAHs degradation rate at the 10 mgL–1 dosage of O3 assisted with ultrasonication was equal to 96%.
Źródło:
Innovations – Sustainability – Modernity – Openness. Modernity in engineering; 55-65
9788366391901
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie baterii biotestów do oceny wpływu zrzutów przemysłowych na ekosystem wodny rzeki Kłodnicy
Impact of industrial discharges on aquatic ecosystems of Kłodnica river based on the results of bioassays battery
Autorzy:
Zgórska, Aleksandra
Bondaruk, Jan
Dudziak, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/401911.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ekosystemy wodne
bateria biotestów
bioindykacja
ścieki przemysłowe
wody kopalniane
water ecosystems
biotest battery
bioindication
industrial wastewater
mine water
Opis:
W celu oszacowania wpływu zanieczyszczeń antropogenicznych na ekosystemy wodne, dla rzeczywistych próbek środowiskowych przeprowadzono analizę ekotoksykologiczną. Badania bioindykacyjne wykonano dla próbek wód powierzchniowych pobranych w 10 wyznaczonych miejscach pomiarowych rz. Kłodnicy na odcinku od źródła – do ujścia Potoku Bielszowickiego. W ramach analizy ekotoksykologicznej zastosowano baterię biotestów, obejmującą testy na skorupiakach (Daphnia magna), bakteriach (Vibrio fiascherii) oraz roślinach hydrofitowych (Lemna minor). Z przeprowadzonych badań wynika, że za wyjątkiem miejsc zlokalizowanych bezpośrednio za punktami zrzutu, próbki wód rzecznych nie wpływają negatywnie na organizmy testowe. Żadna z przeanalizowanych próbek wody nie wpłynęła na przeżywalność skorupiaków z gatunku Daphnia magna. Podobne wyniki uzyskano w teście MICROTOX® z wykorzystaniem bakterii bioluminescencyjnych Vibrio fischerii, w którym, w skutek stymulacji procesów metabolicznych u organizmów testowych odnotowano wystąpienie zjawiska hormezy. Osiem z dziesięciu przeanalizowanych próbek wody sklasyfikowano jako próbki nietoksyczne (Klasa I – brak ostrego zagrożenia). Z uwagi na wynik testu fitotoksyczności (inhibicja na poziomie 25% i 50%) dwie z dziesięciu przeanalizowanych próbek wód powierzchniowych sklasyfikowano jako próbki charakteryzujące się niewielkim ostrym zagrożeniem (Klasa II).
The main goal of the research was the assessment of the impact of industrial and municipal wastewater discharges on aquatic ecosystems of Kłodnica river. The conducted studies were based on bioindication methods. Within the ecotoxicological analyses the biotest battery was used. The scope of the analysis included determination of influence of anthropogenic pollutants present in Kłodnica river on growth of hydroponic plant (Lemna minor). Also the acute toxicity test using crustacean (Daphnia magna) and bioluminescence bacteria (Vibrio fischeri) were performed. Toxic effects were observed only during the phytotoxicity test in which the plant growth inhibition level exceed respectively 25% and 50%. During the research no other toxic effects of analysed river water samples was observed. The analysed samples did not affect the inhibition of metabolic process of bacteria Vibrio fischerii, on the contrary, the water high salinity stimulate it. During the MICROTOX® test the phenomenon of hormesis was observed.
Źródło:
Inżynieria Ekologiczna; 2019, 20, 2; 15-23
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of modernization of the water treatment system in a selected swimming pool
Autorzy:
Wyczarska-Kokot, Joanna
Dudziak, Mariusz
Lempart, Anna
Powiązania:
https://bibliotekanauki.pl/articles/208181.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
quality control
swimming pools
water quality
kontrola jakości
baseny
jakość wody
dezynfekcja wody basenowej
Opis:
Based on the analysis of the modernization activities of the pool water treatment technology in a selected indoor swimming pool, the results of water quality improvement have been presented. The analysis of water quality parameters, operating parameters and in-house research that has been carried out in this pool for many years allowed us to evaluate the effects of modernization on water quality improvement, with special consideration of chloramine content in pool water (as a disinfection by product). The results of the research have been analyzed in terms of the current sanitary and hygienic guidelines for swimming pools.
Źródło:
Environment Protection Engineering; 2019, 45, 1; 31-43
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Chlorine distribution in the indoor and outdoor swimming pools
Rozkład chloru w basenie krytym i otwartym
Autorzy:
Wyczarska-Kokot, Joanna
Lempart, Anna
Dudziak, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/126109.pdf
Data publikacji:
2019
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
indoor swimming pool
outdoor swimming pool
free chlorine
combined chlorine
reliable sampling point
basen kryty
basen otwarty
zawartość chloru
miarodajne punkty poboru próbek
Opis:
The results of research on the distribution of chlorine content in the characteristic points of the outdoor pool (SPO) and indoor pool (SPI) are presented. Sports and recreational pools for swimmers were selected for the study. Technical and technological parameters of these pools are presented. Free chlorine and combined chlorine were the basic parameters affecting the quality of pool water. Their quick and easy estimation allowed to assess the spread of the disinfectant in swimming pools and the effectiveness of its operation. In both swimming pools, there was a large variation in the chlorine content and non-compliance with the requirements in this area (in SPI, content of combined chlorine > 0.3 mg Cl2/dm3, in the SPO content of free chlorine > 0.6 mg Cl2/dm3). In the SPI, in contrast to the SPO, a significant variation in chlorine concentrations was observed in samples taken from various points in the same series. Based on the analysis of the chlorine content in the characteristic points of swimming pools and physio-chemical and bacteriological supplementary parameters, an attempt was made to determine reliable sampling points to assess the quality of water. The test results were compared with the recommendations regarding the quality of swimming pool water.
Przedstawiono wyniki badań nad rozkładem zawartości chloru w charakterystycznych punktach niecek basenu otwartego (SPO) i krytego (SPI). Do badań wybrano baseny o charakterze sportowo-rekreacyjnym, dla osób umiejących pływać. Przedstawiono techniczne i technologiczne parametry tych basenów. Chlor wolny oraz chlor związany były podstawowymi parametrami wpływającymi na jakość wody basenowej. Szybki i łatwy sposób ich oznaczenia pozwolił ocenić rozprzestrzenianie się środka dezynfekcyjnego w nieckach basenowych i skuteczność jego działania. W obu basenach stwierdzono duże zróżnicowanie zawartości chloru i niezgodność z wymogami w tym zakresie (w SPI zawartość chloru związanego > 0,3 mg Cl2/dm3, w SPO zawartości chloru wolnego > 0,6 mg Cl2/dm3). W basenie SPI w odróżnieniu od SPO obserwowano znaczne zróżnicowanie stężeń chloru w próbkach pobranych z różnych punktów w tej samej serii pomiarowej. Na podstawie analizy zawartości chloru w charakterystycznych punktach niecek basenowych oraz uzupełniających parametrów fizyczno-chemicznych i bakteriologicznych podjęto próbę wyznaczenia miarodajnych punktów poboru próbek wody basenowej w celu oceny jej jakości. Wyniki badań porównano z zaleceniami, jakim powinna odpowiadać woda w pływalniach.
Źródło:
Proceedings of ECOpole; 2019, 13, 1-2; 77-84
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of an unmanned aircraft system’s airworthiness for certification
Autorzy:
Dudziak, Dominika
Buczkowska-Murawska, Teresa
Żokowski, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/2091206.pdf
Data publikacji:
2020
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
certification
standardisation agreement
safety
unmanned aircraft system
certyfikacja
porozumienie normalizacyjne
bezpieczeństwo
samolot bezzałogowy
Opis:
This article shows that there is a need to carry out the certification process of the system of Unmanned Aircraft Systems (UAS) as an element conditioning the safety of their operation. The published statistics related to the operation of this type of technical objects were presented and analysed stating that one of the causes of incidents and accidents involving the unmanned aircraft mostly includes failure of components of the unmanned aircraft systems. Considering the lack of definitive formulated legislation and procedures in this area, it gains particular importance. Bearing in mind the review nature of this article, it also introduces basic information on the certification of unmanned aircraft systems, according to standardisation agreements of the North Atlantic Treaty Organisation (NATO). Furthermore, this article presents the characteristics of unmanned aircraft systems, especially for this class of devices, in case of their failure there is no ultimate level of safety guarantee, which is the human factor – operatoraction.
Źródło:
Zeszyty Naukowe. Transport / Politechnika Śląska; 2020, 108; 27--36
0209-3324
2450-1549
Pojawia się w:
Zeszyty Naukowe. Transport / Politechnika Śląska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies