Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Świercz, E." wg kryterium: Autor


Tytuł:
Automatic Classification of LFM Signals for Radar Emitter Recognition Using Wavelet Decomposition and LVQ Classifier
Autorzy:
Świercz, E.
Powiązania:
https://bibliotekanauki.pl/articles/1505216.pdf
Data publikacji:
2011-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
84.40.Ua
84.35.+i
Opis:
The paper presents a novel approach, based on the wavelet decomposition and the learning vector quantisation algorithm, to automatic classification of signals with linear frequency modulation, generated by radar emitters. The goal of radar transmitter classification is to determine the particular transmitter, from which a signal originated, using only the just received waveform. To categorise a current linear frequency modulation signal to the particular transmitter, the discrete wavelet decomposition of the received signal is accomplished in order to get a representative set of features with good classification properties. The learning vector quantisation algorithm with a previously defined set of features as an input of the learning vector quantisation neural net is proposed as the intelligent classification algorithm, which combines competitive learning with supervision. After the learning process, the learning vector quantisation algorithm is ready to perform the classification process for different data than data used in the learning stage. Simulation results show the high classification accuracy for experimentally chosen wavelets and suggested architecture of the learning vector quantisation classifier.
Źródło:
Acta Physica Polonica A; 2011, 119, 4; 488-494
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Classification in the Gabor time-frequency domain of non-stationary signals embedded in heavy noise with unknown statistical distribution
Autorzy:
Świercz, E.
Powiązania:
https://bibliotekanauki.pl/articles/907771.pdf
Data publikacji:
2010
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
sygnał niestacjonarny
klasyfikacja sygnału
rozpoznawanie obrazów
transformator czas-częstotliwość
non-stationary signals
signal classification
pattern recognition
time-frequency transforms
Opis:
A new supervised classification algorithm of a heavily distorted pattern (shape) obtained from noisy observations of nonstationary signals is proposed in the paper. Based on the Gabor transform of 1-D non-stationary signals, 2-D shapes of signals are formulated and the classification formula is developed using the pattern matching idea, which is the simplest case of a pattern recognition task. In the pattern matching problem, where a set of known patterns creates predefined classes, classification relies on assigning the examined pattern to one of the classes. Classical formulation of a Bayes decision rule requires a priori knowledge about statistical features characterising each class, which are rarely known in practice. In the proposed algorithm, the necessity of the statistical approach is avoided, especially since the probability distribution of noise is unknown. In the algorithm, the concept of discriminant functions, represented by Frobenius inner products, is used. The classification rule relies on the choice of the class corresponding to the max discriminant function. Computer simulation results are given to demonstrate the effectiveness of the new classification algorithm. It is shown that the proposed approach is able to correctly classify signals which are embedded in noise with a very low SNR ratio. One of the goals here is to develop a pattern recognition algorithm as the best possible way to automatically make decisions. All simulations have been performed in Matlab. The proposed algorithm can be applied to non-stationary frequency modulated signal classification and non-stationary signal recognition.
Źródło:
International Journal of Applied Mathematics and Computer Science; 2010, 20, 1; 135-147
1641-876X
2083-8492
Pojawia się w:
International Journal of Applied Mathematics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Calculations of individual air supply systems
Obliczenia indywidualnych systemów nawiewnych
Autorzy:
Zender-Świercz, E.
Powiązania:
https://bibliotekanauki.pl/articles/402292.pdf
Data publikacji:
2016
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
ventilation
amount of inflow and outflow air
calculation
wentylacja
ilość napływu i odpływu powietrza
obliczenia
Opis:
The article presents a method for calculating the amount of air flowing in and flowing out of the building. It included two variants: the first – the air inflow by infiltration and by the individual duct of the supply system by gravity, the second – the air inflow by infiltration and by the individual duct of the supply system in a mechanical way. The methodology takes into account the pressure produced by the wind, the pressure in the duct and the pressure produced by the fan. The developed method was validated by comparing it with the results of measurements carried out. It has been shown high conformity of calculations and experimental analysis.
Źródło:
Structure and Environment; 2016, 8, 2; 125-130
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microclimate in rooms heated by tiled fireplace with the function of accumulation of heat
Mikroklimat w pomieszczeniach ogrzewanych piecem kominkowym z funkcją akumulacji ciepła
Autorzy:
Telejko, M.
Zender-Świercz, E.
Powiązania:
https://bibliotekanauki.pl/articles/402011.pdf
Data publikacji:
2016
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
building physics
ventilation
indoor air quality
heating by tiled fireplace
fizyka budowli
wentylacja
jakość powietrza wewnętrznego
ogrzewanie kominkowe
Opis:
The article presents the analysis of microclimate in rooms equipped with tiled fireplace with the function of accumulation of heat. Two research series, conducted in used premises, were presented.
Źródło:
Structure and Environment; 2016, 8, 4; 273-277
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elimination of the negative influence of tight buildings structure on ventilation
Wyeliminowanie negatywnego wpływu szczelnej konstrukcji budynków na wentylację pomieszczeń
Autorzy:
Zender-Świercz, E.
Piotrowski, J. Z.
Powiązania:
https://bibliotekanauki.pl/articles/402364.pdf
Data publikacji:
2009
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
wentylacja budynków
szczelna struktura budynku
building ventilation
tight building structure
Opis:
Ventilation of accomodation in warmed buildings well with tight windows' joinery is perturbed. The two-function heaters which are more and more frequently installed in the flats make up additional problem. This article presents results of reaserch on example of two apartments furnished with Individual System of Air Intake. This system causes reduction of CO2 concentration in rooms. Valus of this parameter has been under permissible valus (1000 ppm). The air humidity has decreased what causes reduction of the stuffy air feeling the room. In result of ventilation system action, the working of two-function water heaters has not been perturbed.
Źródło:
Structure and Environment; 2009, 1, 1; 43-46
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Calculation of temperature in ventilating roof space
Obliczanie temperatury powietrza w przestrzeni dachów wentylowanych
Autorzy:
Zender-Świercz, E.
Piotrowski, J. Z.
Powiązania:
https://bibliotekanauki.pl/articles/402420.pdf
Data publikacji:
2010
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
przestrzeń dachów wentylowanych
kratki wentylacyjne
kondensacja wilgoci
ventilating roof space
air grates
moisture condensation
Opis:
Condensation is a problem in the roof space. The solution to this problem is an air-hole in the roofing. We can calculate the air temperature in the roof space with equations found in literature. The modified equations are presented in this article. They take the air-hole area into consideration.
Źródło:
Structure and Environment; 2010, 2, 1; 59-62
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermomodernization a building and its impacy on the indoor microclimate
Termomodernizacja budynku i jej wpływ na mikroklimat w pomieszczeniach
Autorzy:
Zender-Świercz, E.
Piotrowski, J. Z
Powiązania:
https://bibliotekanauki.pl/articles/402523.pdf
Data publikacji:
2013
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
ventilating
thermomodernization
moisture condensation
wentylacja
termomodernizacja
kondensacja wilgoci
Opis:
Analysis of indoor climate conditions showed problems with the proper operation of ventilation systems in the thermomodernization building. Thermomodernization was to seal the roof. The result of the study is a proposal for a global view of the building instead of narrowly targeted on thermal insulation and sealing the building envelope. Such an approach will prevent the feeling of discomfort inside the flats and provide an appropriate level of microclimate parameters.
Źródło:
Structure and Environment; 2013, 5, 3; 37-40
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Poprawa mikroklimatu wewnątrz budynków wielorodzinnych
Improvement in microclimate in multi-storey buildings
Autorzy:
Zender-Świercz, E
Piotrowski, J. Z
Powiązania:
https://bibliotekanauki.pl/articles/362587.pdf
Data publikacji:
2011
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
mikroklimat pomieszczeń
parametry komfortu
indywidualny system nawiewny
room microclimate
comfort parameters
individual system of air intake
Opis:
Kształtowanie mikroklimatu wewnętrznego w budynkach wielorodzinnych sprawia wiele problemów. Dodatkowo komplikuje sprawę dążenie do energooszczędności budynków. Ilość powietrza przepływającego przez pomieszczenia jest niewystarczająca co powoduje wzrost stężenia dwutlenku węgla do wartości przewyższających dopuszczalne. Artykuł prezentuje wyniki badań warunków mikroklimatycznych w lokalach, w których zainstalowano indywidualny system nawiewny (ISN). Stężenie CO2 uległo zmniejszeniu, zmianie nie uległa temperatura, a wilgotność utrzymywała się w zakresach dopuszczalnych.
The usage of Individual System of Air Intake was the way of improving the indoor microclimate. This system used of existing ventilation ducts. It means that costs of ISN is lesser than typical mechanical ventilation system. The CO2 concentration was reduced when the ISN was working. The temperature of indoor air did not change. The humidity of indoor air was in range of acceptable values. The mathematical model makes possible air stream calculations.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2011, T. 6, nr 4, 4; 85-89
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kształtowanie się mikroklimatu w pomieszczeniach wyposażonych w indywidualny system nawiewny
Microclimate in rooms with individual system of air intake
Autorzy:
Zender-Świercz, E.
Piotrowski, J. Zb.
Powiązania:
https://bibliotekanauki.pl/articles/362770.pdf
Data publikacji:
2010
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
mikroklimat pomieszczeń
komfort cieplny
indywidualny system nawiewny
microclimate of the room
thermal comfort
individual system of air intake
Opis:
Stosowanie dwufunkcyjnych podgrzewaczy wody zasilanych gazem powoduje zagrożenie życia mieszkańców w przypadku niewłaściwej pracy instalacji wentylacyjnej. Fakt ten jest powodem rozpoczęcia badań nad mikroklimatem pomieszczeń wyposażonych w wyżej wymienione urządzania. Wyniki badań wykazały przekroczenie dopuszczalnego stężenia dwutlenku węgla (CO2). Sposobem rozwiązania problemu było zastosowanie Indywidualnego Systemu Nawiewnego co zredukowało koncentrację dwutlenku węgla (CO2) oraz spowodowało zmiejszenie wilgotności powietrza.
In flats equipped with two - function water heaters the CO2 concentration exceeds the permitted value. It means that residents of those flats was threatened by death. The usage of Individual System of Air Intake was the way of improving the indoor microclimate. The CO2 concentration and air humidity was reduced. People experience thermal comfort.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2010, T. 5, nr 1, 1; 67-69
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The analysis of thermal comfort in the school and the wedding house
Analiza komfortu cieplnego w szkole i domu weselnym
Autorzy:
Zender-Świercz, E.
Jędrzejczyk, O.
Kaczorowska, K.
Powiązania:
https://bibliotekanauki.pl/articles/402185.pdf
Data publikacji:
2018
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
thermal comfort
air conditioning
simulation
komfort termiczny
klimatyzacja
symulacje
Opis:
The environment, where people are staying, should provide thermal comfort. It means that the equilibrium of the amount of heat produced in the human body and the amount of heat lost to the environment should be kept. To achieve the suitable conditions of air there the air conditioning, ventilation and heating systems are used. These systems regulate the air parameters and maintain them at the desired level. Designers locate, most commonly, the supply units of air conditioning systems in the ceiling in the central part of the room or near the windows without taking into account the specificity of the premises. However, such an approach may contribute to the lack of thermal comfort. The sensation of air is a very subjective indicator that depends on many variables. The authors of the article made an attempt to analyze the influence of the type of air conditioning system and location of air supply units on the thermal comfort in rooms of different use.
Środowisko, w którym przebywa człowiek powinno zapewniać odczuwanie komfortu. tzn. powinna być zachowana równowaga pomiędzy ilością ciepła wytwarzanego w ciele człowieka a ilością ciepła traconego do otoczenia. Aby uzyskać taki stan powietrza w pomieszczeniach, stosuje się różne systemy wentylacji, klimatyzacji i ogrzewania. Układy te regulują parametry powietrza i utrzymują je na żądanym poziomie. Projektanci lokalizują elementy nawiewne instalacji klimatyzacji najczęściej w suficie w centralnej części pomieszczenia lub przy oknach bez uwzględniania specyfiki pomieszczenia. Jednak takie spojrzenie na instalację może przyczynić się do braku warunków komfortu cieplnego. Postrzeganie stanu powietrza jest bardzo subiektywnym wskaźnikiem zależnym od wielu zmiennych. W artykule podjęto próbę analizy wpływu rodzaju instalacji klimatyzacji oraz rozmieszczenia elementów nawiewnych w pomieszczeniach o różnym przeznaczeniu.
Źródło:
Structure and Environment; 2018, 10, 1; 75-81
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jakość powietrza w wielorodzinnych budynkach mieszkalnych
Indoor air quality in multifamily buildings
Autorzy:
Telejko, M.
Zender–Świercz, E.
Piotrowski, J.Z.
Powiązania:
https://bibliotekanauki.pl/articles/390643.pdf
Data publikacji:
2013
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
jakość powietrza wewnętrznego
mikroklimat
wymiana powietrza
fizyka budowli
indoor air quality
microclimate
air exchange
building physics
Opis:
Obowiązujące aktualnie przepisy prawne regulujące zagadnienia wentylacji naturalnej [1], [2], [3] w wielu obszarach są niejednoznaczne, a niekiedy wręcz sprzeczne. Sytuacja taka prowadzi do stosowania rozwiązań powodujących poważne zaburzenia w działaniu wentylacji grawitacyjnej. W dużej części budynków zaburzenia te są wynikiem dostarczania do pomieszczeń zbyt małej ilości powietrza zewnętrznego. Jak wykazały badania, ze względu na kształtowanie warunków mikroklimatu wnętrz, podstawowe znaczenie ma nie tylko wielkość dostarczanego strumienia powietrza zewnętrznego, ale również rozmieszczenie elementów doprowadzających to powietrze.
The applicable legislation connected with the natural ventilation are ambiguous and sometimes contradictory. This leads to serious problems with natural ventilation. In most cases malfunction of the natural ventilation is due to the insufficient stream of air from the outside. The research showed that the microclimate is influenced not only by the incoming air stream, but also by the layout of the air supply.
Źródło:
Budownictwo i Architektura; 2013, 12, 3; 67-74
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Próba poprawy jakości powietrza wewnętrznego w przedszkolu
Indoor air quality in a preschool
Autorzy:
Koruba, D.
Zender-Świercz, E.
Piotrowski, J.Z.
Orman, Ł.
Telejko, M.
Powiązania:
https://bibliotekanauki.pl/articles/390993.pdf
Data publikacji:
2014
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
fizyka budowli
wentylacja
wymiana powietrza
jakość powietrza wewnętrznego
building physics
ventilation
air exchange
indoor air quality
Opis:
W artykule przedstawiono wyniki badań nad jakością powietrza wewnętrznego (IAQ) w jednym z wybranych przedszkoli. W obiekcie zastosowany został system wentylacji grawitacyjnej. Wstępne badania potwierdziły niską jakość powietrza wewnętrznego w podmiotowym budynku. W trakcie badań zaproponowano dwa usprawnienia mające na celu poprawę jakości powietrza: zwiększenie strumienia powietrza nawiewanego oraz, w drugiej kolejności, montaż urządzeń do uzdatniania powietrza wewnętrznego. Uzyskane wyniki badań wskazują, że wprowadzone usprawnienia wpływają na poprawę jakości powietrza wewnętrznego.
The article demonstrates the results of research on the indoor air quality (IAQ) in one of chosen preschools. In such facilities, the standard solution is a system of natural ventilation. Only a small percentage of such buildings is equipped with a mechanical ventilation system with adjustable parameters of the microclimate. The article presents the results of indoor air quality in the local preschool located in Kielce. In the present facility natural ventilation system was used. Preliminary studies confirmed the poor quality of indoor air in a subjected building. During the study, two improvements aimed at improving air quality were proposed. The first improvement was to increase the supply air stream. The second one concerned the installation of equipment for the treatment of indoor air. The results indicate that under certain guidelines it is possible to improve indoor air quality. As an indicator of indoor air quality, concentration of carbon dioxide was adopted. In addition, microbiological tests were performed indoors.
Źródło:
Budownictwo i Architektura; 2014, 13, 4; 7-13
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Data on acoustic and thermal properties of reflective insulation
Właściwości akustyczne i cieplne izolacji refleksyjnej
Autorzy:
Dachowski, R.
Piotrowski, J. Z.
Koruba, D.
Zender-Świercz, E.
Telejko, M.
Starzomska, M.
Lucas, X.
Powiązania:
https://bibliotekanauki.pl/articles/402505.pdf
Data publikacji:
2014
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
acoustics
reflective insulation
thermal resistance
akustyka
izolacja refleksyjna
opór cieplny
Opis:
The paper presents the test results of acoustic insulation properties of reflective insulation. The experiments were performed for three different types of insulation and two values of air gap, namely 2 cm and 4 cm. A significant reduction of the sound level was recorded. Selected thermal and mechanical properties are also given in the paper.
Źródło:
Structure and Environment; 2014, 6, 1; 38-42
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Variations in the zinc and lead content in surface layers of urban soils in Kielce (Poland) with regard to land use
Autorzy:
Swiercz, A.
Smorzewska, E.
Powiązania:
https://bibliotekanauki.pl/articles/15923.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie / Polskie Towarzystwo Magnezologiczne im. Prof. Juliana Aleksandrowicza
Tematy:
soil
urban soil
Kielce town
zinc content
lead content
heavy metal
surface layer
land use
Polska
Opis:
The article presents an overview of the results of a study concerning the zinc and lead content in urban soils of Kielce with regard to different land use. 61 topsoil samples were collected in the industrial areas (I), urban green areas (Z), urban allotment gardens (O), as well as parks and forests (P). The maximum values for zinc and lead were observed in the industrial zone, i.e. 181.3 mg kg-1 and 112.6 mg kg-1, respectively; whereas the average content in the soils of Kielce oscillates at the level of 134.2 mg kg-1 for zinc and 92.85 mg kg-1 for lead. Geochemical indices, such as the geoaccumulation index (Igeo), contamination factor (CF) and accumulation index (AI) indicated that areas located in close proximity to the main roads of the city, especially in the city centre and the former industrial estate called Białogon, are characterised by the highest concentration of the analysed heavy metals. Generally, the enrichment of soils in zinc and lead decreases further from the city centre. In most cases, the content of the analysed heavy metals in surface layers of urban soils considerably exceeded values considered as geochemical background and valid legal norms of the Ordinance of the Minister of Environment on soil quality standards and land quality standards (Journal of Laws of 2002, No. 165, item 1359). The exceeded values of the analysed metals are caused mainly by deposition of contamination from car exhaust emissions and broadly defined industry.
Źródło:
Journal of Elementology; 2015, 20, 2
1644-2296
Pojawia się w:
Journal of Elementology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of heavy metal content in the soils of industrial sites in Skarzysko-Kamienna and Kielce
Ocena koncentracji metali ciężkich w glebach użytków przemysłowych na przykładzie Kielc i Skarżyska-Kamiennej
Autorzy:
Świercz, A.
Zajecka, E.
Powiązania:
https://bibliotekanauki.pl/articles/126111.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
urban soils
Kielce
Skarżysko-Kamienna
copper
zinc
lead
geoaccumulation index Igeo
pH
gleby miejskie
miedź
cynk
ołów
indeks geoakumulacji Igeo
Opis:
This article presents the results of the analysis of selected heavy metal concentrations in the urban soils of Skarzysko-Kamienna and Kielce. The studies were conducted on industrial soils. In the collected soil samples, the total content of Cu, Zn, and Pb - after mineralisation in aqua regia - was determined by the flame atomic absorption spectrometry (FAAS) method. A pH, in turn, was determined by the potentiometric method. The soils of Skarzysko-Kamienna were characterised by the following concentrations of heavy metals: Cu - 2.0-261 mg/kg d.m.; Zn - 9.0-352 mg/kgd.m.; Pb - 2.0-1600 mg/kg d.m. The concentrations of heavy metals in the soils of Kielce were oscillating as follows: Cu: 2.40-134.2 mg/kg d.m., Zn: 17.2-1646 mg/kg d.m, Pb: 10.4-1428 mg/kg d.m. The elevated concentrations were reported for all analysed heavy metals in accordance with the values of geochemical background determined for each chemical element. The obtained results indicated moderate values of geoaccumulation indices Igeo. The soils of both cities were characterised by either slightly acidic or slightly alkaline pH. However, the values observed for the soils of Skarzysko-Kamienna were lower than those noted for the soils of Kielce.
Przedstawiono wyniki badań zawartości wybranych metali ciężkich w glebach miejskich Kielc oraz Skarżyska-Kamiennej. Badania prowadzono na glebach o przeznaczeniu przemysłowym. W pobranym materiale glebowym wykonano oznaczenie Cu, Zn oraz Pb metodą atomowej spektrometrii absorpcyjnej ASA po mineralizacji w wodzie królewskiej oraz badania wartości odczynu metodą potencjonometryczną. Gleby Skarżyska-Kamiennej cechują się zawartością metali ciężkich na poziomie Cu: 2,0-261 mg/kg s.m., Zn: 9,0-352 mg/kg s.m, Pb: 2,0-1600 mg/kg s.m. W badanych glebach Kielc zawartość metali oscylowała na poziomie: Cu: 2,40-134,2 mg/kg s.m., Zn: 17,2-1646 mg/kg s.m, Pb: 10,4-1428 mg/kg s.m. Stwierdzono podwyższoną zawartość analizowanych metali w odniesieniu do wartości tła geochemicznego wyznaczonego dla każdego z pierwiastków. Badania wskazują na umiarkowane wartości wskaźników geoakumulacji Igeo. Gleby obu miast charakteryzowały się odczynem od lekko kwaśnego do lekko alkalicznego. Jednak wartości, jakie zostały zanotowane dla gleb Skarżyska-Kamiennej, były niższe niż te dla gleb Kielc.
Źródło:
Proceedings of ECOpole; 2017, 11, 1; 97-103
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies