Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "fire temperatures" wg kryterium: Wszystkie pola


Tytuł:
Analysis of impact of aeration modifications on strength parameters of concrete under fire conditions
Autorzy:
Ogrodnik, P.
Zegardlo, B.
Powiązania:
https://bibliotekanauki.pl/articles/30147149.pdf
Data publikacji:
2018
Wydawca:
Akademia Wojsk Lądowych imienia generała Tadeusza Kościuszki
Tematy:
concrete
fire temperatures
strength
Opis:
Modern dynamically developing building industry poses more and more complex challenges to building materials. Elevated constructions must satisfy a number of requirements including safety, durability and being environmentally friendly. The unfavorable impact of increased temperatures on the work of a construction structure is manifested by the change in the properties of the heated material and the occurrence of deformation, stresses and thermal scratches. These are particularly dangerous phenomena when they occur in elements with limited freedom of linear deformation. The purpose of the research presented in this article was to find a solution for concrete that is both resistant to spalling and characterized by high strength properties after heating. The main thesis put forward by the authors of the article is the assumption that deliberate concrete aeration will allow the introduction of evenly distributed micro air bubbles into its volume, which will constitute a reservoir for increasing the volume of water converting into water vapor as a result of a sudden increase in temperature. The presented schema enabled the assumption that the strength parameters of aerated concrete would decrease slightly in relation to non-aerated concrete, however it would be still possible to use in reinforced concrete constructions. As can be seen from the aforementioned analyzes, aeration modification can be an effective means of designing high temperature resistant concrete.
Źródło:
Scientific Journal of the Military University of Land Forces; 2018, 50, 2(188); 187-196
2544-7122
2545-0719
Pojawia się w:
Scientific Journal of the Military University of Land Forces
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odporność betonu na pękanie w temperaturach pożarowych
Concrete resistance to cracking at fire temperatures
Autorzy:
Plechawski, Stanisław
Powiązania:
https://bibliotekanauki.pl/articles/160440.pdf
Data publikacji:
2019
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
beton
odporność
temperatura pożaru
pękanie
badanie
makrostruktura
mikroskop skaningowy
SEM
concrete
resistance
fire temperature
cracking
study
macrostructure
scanning microscope
Opis:
W artykule zostanie omówiony wpływ temperatur pożarowych na najważniejszy kompozyt cementowy, jakim jest beton. Badania własne wykazały, że uszkodzenia powstałe w stadium początkowego twardnienia kompozytów cementowych przed użytkowaniem, jak i w jego trakcie, propagują pod wpływem wysokich temperatur i wpływają na właściwości fizykochemiczne, strukturalne oraz mechaniczne tych kompozytów, a ich wielkość może być oceniana za pomocą krytycznego współczynnika intensywności naprężeń KIC, który jest miarą odporności na pękanie.
The aim of this article is to discuss the effect of fire temperatures on the most important cement composite, which is concrete. The author’s research has indicated that damage caused at the stage of initial hardening of cement composites before and during their use, propagates at high temperatures and affects the physicochemical, structural and mechanical properties of these composites, whereas their size can be assessed using the critical stress intensity factor KIC, which constitutes a measure of resistance to cracking.
Źródło:
Przegląd Budowlany; 2019, 90, 7-8; 90-96
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Resistance of Steel Fasteners Subjected to Shear at Public Arenas in Normal and Fire Temperatures - Probabilistic Approach
Autorzy:
Domański, T.
Powiązania:
https://bibliotekanauki.pl/articles/105019.pdf
Data publikacji:
2018
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
steel structures
structural safety
steel bolt connections
fire safety
Opis:
The buildings with great grandstands are the public places where consequences of failure are very high. For this reason, according to EN 1990 they belong to CC3 class consequence of failure. The reliability class RC3 is associated with the consequences class CC3 [7, 8] and is defined by the β = 4.3 reliability index with probability of failure pf ≈ 8.54·10-6. Shear connections have to transfer forces between structural members – steel body and bolts with adequate degree of safety. The load-carrying mechanism of bolted shear connections is complex and analytical methods for predicting the shear resistance are not applicable. Instead the resistance of the connections may be determined using empirical formulas. The distributions of horizontal and shear resistance within steel body - bolts will be described depending on material characteristics of steel body and bolts components. The characteristic resistance of steel shear connection is obtained as minimum of two variables: bolds resistance and steel body resistance. Probability function of this minima will be defined and described in this paper. Laboratory tests provide the only practicable basis for specifying safety margins for ultimate strength connections. The determination of partial safety factors within shear connections will be presented according to EN1990. Design value of such resistance is specified as suitable fractile of log- normal probability distribution, calculated with the assumption that the acceptable probability of down-crossing is not greater than pf,ult ≈ 2.91·10-4. It means that the target reliability index, defined for the resistance, is taken as βR.req = 3.44, in accordance with the European recommendations (EN 1990).
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2018, 65, 2; 17-24
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie betonu na kruszywie odpadowym w warunkach oddziaływania temperatur pożarowych
Examination of concrete produced on the waste aggregate in fire temperatures
Autorzy:
Banaś, M.
Powiązania:
https://bibliotekanauki.pl/articles/136829.pdf
Data publikacji:
2018
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
kruszywo recyklingowe
pożar
wytrzymałość betonu
recycle aggregate
fire
strength of concrete
Opis:
W artykule przedstawiono wyniki badań wytrzymałościowych próbek betonowych na kruszywie odpadowym. Próbki zostały poddane badaniom niszczącym po wygrzaniu w piecu, gdzie proces przebiegał według krzywej pożarowej temperatura – czas. Badano również wpływ czasu wiązania betonu na wytrzymałość na ściskanie.
The article presents the results of the research dealing with the strength of concrete samples on the waste aggregate. The samples were subjected to the destructive tests after the warming in the oven where the process was running according to the fire curve, temperature – time. The influence of the concrete setting on the strength and the compression was tested.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2018, 1, 66; 49-61
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza destrukcyjnego wpływu nasączenia wodą na parametry wytrzymałościowe betonów poddanych warunkom pożarowym
An Analysis of the Destructive Influence of Water Saturation on the Durability of Concrete Exposed to a Fire
Autorzy:
Zegardło, B.
Ogrodnik, P.
Powiązania:
https://bibliotekanauki.pl/articles/372768.pdf
Data publikacji:
2016
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
beton żaroodporny
temperatury pożarowe
ceramika sanitarna
refractory concrete
fire temperatures
sanitary ceramics
Opis:
Cel: Celem artykułu było przedstawienie wyników badań betonu skomponowanego z użyciem odpadów ceramiki sanitarnej, jako kruszywa w aspekcie odporności na działanie wysokich temperatur. Znormalizowane próbki betonowe zostały poddane wstępnemu nasączeniu wodą a następnie wygrzane zgodnie z założonym rozkładem „temperatura-czas”. Autorzy artykułu opierając się na wcześniejszych doświadczeniach uzyskali beton o podwyższonej odporności na warunki pożarowe jednocześnie odporny na zjawisko eksplozyjnego odpryskiwania. Metody: Próbki betonowe do badań wytrzymałościowych zostały zaprojektowane w oparciu o cement glinowy i kruszywo na bazie stłuczki ceramicznej. Pierwszą seria próbek poddano nasączeniu poprzez całkowite zanurzenie w wodzie na okres 5 minut po wyjęciu poddano je wstępnemu osuszeniu przez 10 minut. Próbki drugiej serii przebywały zanurzone całkowicie w wodzie przez okres 12 godzin a następnie jak poprzednie zostały wstępnie osuszone. Tak przygotowane próbki umieszczono w średniotemperaturowy piec komorowy typu PK 1100/1 a następnie rozpoczęto proces grzewczy zgodnie z założonym rozkładem „temperatura-czas” aż do osiągnięcia temperatury 1000°C. Badania wytrzymałościowe próbek prowadzono po 30 dniach od ich wygrzewania. Wyniki: Uzyskane wyniki badań potwierdziły znaczący wpływ warunków wilgotnościowych w jakich przebywały próbki betonowe a następnie oddziaływania wysokiej temperatury na ich wytrzymałość. Beton porowaty zaprojektowany w oparciu o doświadczenia projektowania betonów ogniotrwałych po poddaniu wygrzewaniu symulującemu warunki pożarowe cechował się wytrzymałością na ściskanie rzędu 27 MPa. Ten sam beton po zanurzenie w wodzie na okres 5 minut a następnie wygrzaniu uzyskał średnią wytrzymałość 6,42 MPa. Natomiast beton poddany nasączaniu przez okres 12 godzin posiadał średnią wytrzymałość na ściskanie równą 5,79 MPa. Pomimo tego ze próbki poddawane były tym samym zabiegom wytwórczym i pielęgnacyjnym z powodu ich niestandardowej porowatej struktury jak pokazało ważenie wchłaniały różne porcje wody. Przyczynę takiego stanu rzeczy upatruje się w stosunkowo dużej nasiąkliwości samego kruszywa ceramicznego. Jednocześnie podczas wygrzewania do temperatury 1000°C we wszystkich przebadanych próbkach nie zaobserwowano eksplozyjnego odpryskiwania betonu porowatego. Wnioski: Wyniki przeprowadzonych badań dowodzą jak bardzo destrukcyjnym czynnikiem może być wilgotność dla betonu, który poddany jest warunkom pożarowym. Jako przyczynę tej sytuacji upatruje się zjawisko naruszania struktury kompozytu przez zawartą w porach wodę, która zwiększa swoją objętość podczas nagrzewania. Szczególnym wnioskiem z przeprowadzonych badań jest fakt konieczności każdorazowej oceny parametrów wytrzymałościowych elementów betonowych które poddane były oddziaływaniu pożaru. Elementy takie bowiem pomimo zachowania swoich cech zewnętrznych, spoistości niezmiennej struktury i postaci mogą posiadać znacząco niższe parametry wytrzymałościowe co można jedynie określić podczas badań laboratoryjnych.
Aim: The purpose of this paper is to present the results of a study involving concrete, containing sanitary ceramic waste as an aggregate, in context of resistance properties to high temperatures. Standardized concrete specimens were subjected to initial saturation with water and subsequently exposed to a heating process according to a predefined “temperature-time” schedule. Based on the previous experiments, the authors obtained a concrete with increased resistance to the effect of fire and, simultaneously, resistant to effects of thermal spalling. Methods: Concrete specimens used for strength studies were developed using alumina cement mixed with sanitary ceramics waste aggregate. The first batch of specimens were saturated by complete submersion in water for a period of 5 minutes. Subsequently, the removed specimens were dried for 10 minutes. A second batch of specimens was fully submerged for 12 hours, and similarly to the first batch, the specimens were dried. Next, the prepared specimens were placed in a PK 1100/1 type medium range temperature furnace. The heating process was initiated at a predefined “temperature-time” schedule, until a temperature of 1000°C was achieved. Durability tests were performed 30 days after heating. Results: The derived test results verified the significant impact of moist conditions, in which concrete specimens were placed and secondly, the high temperature impact on the specimen durability. A porous concrete prepared based on the design experiences of refractory concrete after heating, which simulated fire conditions, was characterised by a compressive strength of 27 MPa. For the same concrete after submersion in water for 5 minutes and heating, the average strength value was 6.42 MPa. While for the concrete saturated for 12 hours the obtained compressive strength value was 5.79 MPa. Although specimens were subjected to the same manufacturing treatments and care, they absorbed different amounts of water. This was revealed by weighing and is attributable to their non-standard porous structure and significantly high absorption level of ceramic aggregate. The specimens were heated to 1000°C and no thermal spalling was observed for all tested specimens. Conclusions: Study results reveal the destructive impact that moisture can have on concrete, when exposed to the influence of fire. The cause of such a development is perceived to stem from the disturbance caused to the composite structure by the ingress of water, which increases in volume during the heating process. From a performed experiment it is evident that there is a need to conduct an evaluation of durability for all concrete elements, which are exposed to the influence of fire. Such elements, despite constancy associated with their external features, apparent invariable structure and form, in fact can have significantly lower durability parameters, which can only be revealed during laboratory tests.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2016, 41, 1; 27-35
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu temperatury pożarowej na parametry wytrzymałościowe stali B500SP
Analysis of fire temperatures on strength parameters of steel B500SP
Autorzy:
Bednarek, Z.
Kamocka-Bronisz, R.
Ogrodnik, P.
Bronisz, S.
Powiązania:
https://bibliotekanauki.pl/articles/137017.pdf
Data publikacji:
2011
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
stal konstrukcyjna
temperatura pożarowa
parametry wytrzymałościowe
steel construction
fire temperature
strength parameters
Opis:
Opisane w artykule badania realizowano w ramach projektu: „Innowacyjne środki i efektywne metody poprawy bezpieczeństwa i trwałości obiektów budowlanych i infrastruktury transportowej w strategii zrównoważonego rozwoju”. W pracy przedstawiono wyniki badań wpływu temperatury pożarowej na parametry wytrzymałościowe sta li B500SP.
The paper presents the results of tests of the effect of fire temperature on the strength parameters of steel B500SP. The tests were performed on a test stand equipped with testing machine with resistance furnace built in Applied Mechanics Institute of the Main School of Fire Service. The tests were conducted in constant temperatures of 20, 200, 300, 400 and 500°C. The force and elongation values were recorded. On their basis, tensile strength, the proof stress, strength to yield ratio and elongation with maximum force were derived as a function of temperature. The studies described in the article, were carried out within the project: “Innovative measures and effective methods of improving the safety and durability of buildings and transport infrastructure in a sustainable development strategy” under the Innovative Economy Operational Programme 2007–2013.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2011, 42; 75-88
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Niezawodność w wysokich temperaturach klejonego warstwowo drewna sosny pospolitej w zakresie wytrzymałości na zginanie statyczne
Reliability at high temperatures of glued laminated pine timber in the static bending strength
Autorzy:
Pieniak, D.
Ogrodnik, P.
Oszust, M.
Dec, L.
Powiązania:
https://bibliotekanauki.pl/articles/373824.pdf
Data publikacji:
2011
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
drewno klejone
niezawodność
temperatury pożarowe
wytrzymałość na zginanie
bending strength
fire temperatures
glued timber
reliability
Opis:
Drewno klejone ze względu na swoje właściwości, jest coraz częściej wykorzystywane. Technologia ta umożliwia wytworzenie elementów konstrukcyjnych o dużych przekrojach poprzecznych i znacznych rozpiętościach. Drewno klejone warstwowo, po odpowiedniej obróbce powierzchni i zachowaniu parametrów przekroju jest materiałem słabo rozprzestrzeniającym ogień, a dodatkowo impregnowane jest materiałem nierozprzestrzeniającym ognia. Pomimo to, drewno w wysokich temperaturach traci swoje właściwości, a co za tym idzie najprawdopodobniej spada jego wytrzymałość. W badaniach własnych dokonano analizy wytrzymałości na zginanie statyczne drewna klejonego w wysokich temperaturach, zbliżonych do temperatur pożaru. Na podstawie uzyskanych wyników określono prawdopodobieństwo zniszczenia elementu konstrukcji obciążonego statycznie w kolejnych przedziałach temperaturowych. Wykazano znaczący spadek niezawodności drewna klejonego oraz zaobserwowano zwiększoną dynamikę wzrostu poziomu zagrożenia po przekroczeniu temperatury 150[stopni]C.
Due to its properties glued timber is a commonly used material nowadays. Such technology enables production of the structural elements with large cross-sections and considerable span. The glued laminated timber after a proper surface treatment and with the preserved cross-section parameters, is a low fire spreading material, moreover it is additionally treated with a fire retardant. In spite of this, timber loses its properties in high temperatures, which most probably results in the strength reduction. In the conducted studies static bending strength analysis of the glued laminated timber in high temperatures, close to the fire conditions, was performed. Based on the obtained results, probability of failure of the structural element statically loaded, in the subsequent temperature ranges, was estimated. A significant reliability decrease of the glued laminated timber and dynamic of the hazard level growth has been observed after exceeding 150[degrees]C.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2011, 3; 63-68
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie spadku wytrzymałości drewna świerkowego modyfikowanego termicznie w warunkach temperatur pożarowych
The investigation of immediate strength loss of thermally modified spruce timber under fire temperatures
Autorzy:
Oszust, M.
Pieniak, D.
Ogrodnik, P.
Dec, L.
Powiązania:
https://bibliotekanauki.pl/articles/52682.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Drewna
Tematy:
drewno
modyfikacja drewna
modyfikacja termiczna
drewno swierkowe
drewno zmodyfikowane
wytrzymalosc
temperatury pozarowe
Opis:
Modyfikowanie termiczne drewna jest jedną z nowych technologii mających na celu poprawę jego właściwości. Drewno modyfikowane termicznie (TT) charakteryzuje się innymi parametrami użytkowo-estetycznymi niż drewno naturalne niemodyfikowane (NTT). Celem badań była ocena wpływu temperatur występujących w środowisku pożaru na zmiany wytrzymałości drewna świerkowego modyfikowanego termicznie. Badania zostały wykonane na specjalnie zaprojektowanym stanowisku badawczym z możliwością oddziaływania wysokich temperatur. Określono wartości wytrzymałości przy rozciąganiu, ściskaniu oraz zginaniu w temperaturach normalnych i pożarowych. Zaprezentowano analizę porównawczą spadku wytrzymałości drewna świerkowego TT i drewna świerkowego NTT. Wykazano istotny wpływ temperatur pożarowych na spadek wytrzymałości badanego drewna, postępujący w kolejnych przedziałach temperatur.
Thermal modification of timber is one of the new technologies aiming at the improvement of timber properties. Thermally modified timber (TT) has different aesthetic and utility parameters compared to non-modified timber (NTT). The objective of this study was the assessment of the influence of temperatures present in fire conditions on the immediate changes in strength of thermally modified spruce timber. Tests were made at a dedicated test stand equipped with a possibility of producing impact with high temperatures. The values of tensile strength, compression strength and bending strength in normal and fire temperatures conditions were determined. This paper presents a comparative analysis of the strength loss of TT spruce timber and NTT spruce timber. The study confirmed a significant influence of fire temperatures on the strength loss of tested timber in chosen ranges of increasing temperatures.
Źródło:
Drewno. Prace Naukowe. Doniesienia. Komunikaty; 2011, 54, 185
1644-3985
Pojawia się w:
Drewno. Prace Naukowe. Doniesienia. Komunikaty
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zachowania się włókien polipropylenowych stosowanych do fibrobetonu w temperaturach pożarowych
Analysis of behaviour of polypropylene fibers applied for reinforcing of fiber reinforced concrete in fire temperatures
Autorzy:
Drzymała, T.
Półka, M.
Powiązania:
https://bibliotekanauki.pl/articles/136584.pdf
Data publikacji:
2011
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
technologia tworzyw sztucznych
włókna polipropylenowe
spalanie polipropylenu
Opis:
W artykule przedstawiono analizę wybranych właściwości palnych trzech rodzajów włókien polipropylenowych (PP), stosowanych jako dodatki do betonów. W badaniach eksperymentalnych oznaczono temperaturę zapalenia, ciepło spalania oraz dokonano analiz termograwimetrycznych (TG) dla badanych włókien polipropylenowych.
TG and DTG tests conducted in nitrogen let us suppose that the se fibers encapsulated in concrete in conditions of higher temperature and without access to a sufficient amount of oxygen shall be subject to pyrolysis in the similar way. Taking into account temperatures of maximum velocity of mass loss it may be stated that in these conditions the mass of „F” fiber shall be lost most quickly, then „D” fiber and finally „I” fiber.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2011, 42; 53-62
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Degradacja kompozytu konstrukcyjnego LVL w warunkach jednoczesnego oddziaływania obciążeń statycznych i wysokich temperatur
Degradation of LVL composite material in the conditions of simultaneous impact of static loads and high temperatures
Autorzy:
Pieniak, D.
Kordos, P.
Powiązania:
https://bibliotekanauki.pl/articles/395485.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
drewno klejone warstwowo
forniry LVL
temperatury pożarowe
wytrzymałość na ściskanie
degradacja
laminated veneer lumber (LVL)
fire temperatures
compressive strength
degradation
Opis:
Kompozyt na bazie klejonego drewna fornirowanego (LVL) są materiałami coraz częściej wykorzystywanymi w budownictwie. Kompozyt tego typu charakteryzuje się nieco innymi parametrami niż lite drewno, w szczególności istotna jest ich wytrzymałość i charakter anizotropii tych właściwości. W przypadku większość materiałów konstrukcyjnych oddziaływanie temperatur w warunkach pożaru ma wpływ na ich degradację, przejawiającą się utratą wytrzymałości. Celem prezentowanych w artykule badań była ocena wpływu temperatur środowiska pożaru na degradację właściwości wytrzymałościowych kompozytu LVL. Wykazano, że degradacja wytrzymałość na ściskanie kompozytu LVL postępuje systematycznie w kolejnych przedziałach temperatury.
Composites based on laminated veneer lumber (LVL) are more and more commonly used in the building industry. Such composites have a slightly different characteristics compared to a solid wood, particularly with regards to their strength and anisotropy of the properties. In case of majority of construction materials, temperatures impact in the conditions of fire results in degradation process, manifested by the loss of strength. The objective of studies presented in this paper, was the evaluation of fire temperatures impact on the degradation of strength properties of LVL composite. It has been demonstrated that degradation of the compression strength of LVL composite proceeds successively in the subsequent temperature ranges.
Źródło:
Postępy Nauki i Techniki; 2011, 9; 159-166
2080-4075
Pojawia się w:
Postępy Nauki i Techniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie wpływu temperatur występujących w czasie pożaru oraz szokowego chłodzenia na przyczepność stali B500SP i BSt500S do betonu
Study of fire temperatures and shock cooling influence on the bond strength between steel B500SP and BSt500S to concrete
Autorzy:
Bednarek, Z.
Ogrodnik, P.
Kamocka-Bronisz, R.
Bronisz, S.
Powiązania:
https://bibliotekanauki.pl/articles/373782.pdf
Data publikacji:
2013
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
badanie przyczepności
konstrukcje żelbetowe
spadek przyczepności
szokowe chłodzenie
temperatury pożarowe
bond reduction
bond test
fire temperatures
reinforced concrete
shock cooling
Opis:
Artykuł prezentuje wyniki badań wpływu temperatur występujących podczas pożaru na przyczepność stali do betonu oraz oszacowanie tego wpływu na spadek przyczepności. W pracy przedstawiono wyniki badań przyczepności stali żebrowanej B500SP oraz BSt500S do betonu C30/37 w warunkach popożarowych (badanie "na zimno") z uwzględnieniem różnych warunków stygnięcia - w tym szokowego chłodzenia wodą w czasie akcji gaśniczych konstrukcji oraz w trakcie trwania pożaru (badanie "na gorąco"). We wszystkich przebadanych przypadkach stwierdzono znaczący spadek przyczepności na skutek oddziaływania wysokich temperatur. Przedmiot badań jest ściśle związany z bezpieczeństwem konstrukcji budowlanych w czasie trwania pożaru, jak i z oceną ich dalszego użytkowania po przebytym pożarze w wyniku prowadzenia działań gaśniczych. Badania realizowano w ramach projektu pt. "Innowacyjne środki i efektywne metody poprawy bezpieczeństwa i trwałości obiektów budowlanych i infrastruktury transportowej w strategii zrównoważonego rozwoju" POIG.01.01.02-10-106/09-01.
The paper presents results from the research of fire temperatures influence on steel-concrete bond and the estimation of this influence on bond reduction. In this paper the bond test results for ribbed steel B500SP and BSt500S to C30/37 concrete in the after-fire conditions ("cold test") including various cooling conditions - therein shock cooling by water in the course of construction extinguishing actions and in the fire ("hot test") has been described. In all studied cases a significant reduction of bond was stated as a result of high temperatures. The research subject is closely related to the construction structures safety during the fire and the after-fire construction structures usability resulting from conducted extinguishing actions. The research has been carried out as part of project: "Innovative measures and effective methods of improving the safety and the durability of buildings and transport infrastructure in the sustainable development strategy" POIG.01.01.02-10-106/09.-01.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2013, 1; 67-73
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reliability of the thermal treated timber and wood-based materials in high temperatures
Niezawodność konstrukcyjna drewna modyfikowanego termicznie i materiałów drewnopochodnych w podwyższonych temperaturach
Autorzy:
Pieniak, D.
Ogrodnik, P.
Oszust, M.
Niewczas, A.
Powiązania:
https://bibliotekanauki.pl/articles/1366245.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
temperatury pożarowe
drewno klejone warstwowo (GL)
drewno fornirowane warstwowe (LVL)
drewno modyfikowane termicznie (TT)
niezawodność
wytrzymałość na zginanie
fire temperatures
thermally treated timber (TT)
glued laminated timber (GL)
laminated veneer lumber (LVL)
reliability
bending strength
Opis:
Existing wood and wood-based materials have had several drawbacks limiting their use, which in consequence resulted in replacing them by other materials. The most significant problems were limitations regarding maximum dimensions of the components cross - section and capabilities of manufacturing of the large-scale components. Durability and flammability of surfaces were the limiting factors as well. Nowadays, thermally treated wood and wood composites are more and more commonly used in the engineering constructions, such as: glued laminated timber (GL), laminated veneer lumber (LVL) and thermally treated timber (TT). The timber undergoes a process of thermal degradation. In high temperatures timber structure is subject to simultaneous influence in the form of forces and thermal impacts. These factors influence stress distribution in the wood structure and limit its load capacity, reflecting structure decohesion. The aim of the presented studies was to determine impact of increased temperatures on strength of the wood materials and wood-based composites. Additionally, based on the results of the strength studies, analysis of the probabilisty of survival in high temperatures was performed. Samples used in the static bending strength studies were made of the laminatem veneer lumber - LVL, glued laminated pine timber - GL, and thermally treated - TT and non-treated spruce timber - NTT. The samples were in a cuboidal shape with dimensions of 20x20x300 mm. The evaluation of bending strength was performed by means of the universal strength device - FPZ 100/1 (VEB Thuringer Industriewerk Rauenstein, Germany). Fire temperatures conditions were simulated by blowing hot air (GHG 650 LCE). The studies were conducted in the following temperature ranges: 20, 50, 100, 150, 200 and 230 ±C. Based on the obtained results a reliability analysis was performed. For the analysis a two-parameter Weibull distribution was applied. In case of materials with laminated structure - LVL and GL, an increase in standard deviation of the results of bending strength in the successive temperature ranges has been observed. Higher values of shape parameter c of Weibull distribution have been demonstrated for TT spruce timber (the highest c = 5.58) and NTT (the highest c = 3.31).
Dotychczasowe materiały drewniane i drewnopochodne miały wiele wad ograniczających ich zastosowanie, co prowadziło do zastępowania ich innymi. Największy problem stanowiły ograniczenia, co do maksymalnych wymiarów przekroju elementów oraz możliwości wykonywania elementów o znacznych rozpiętościach, również trwałość powierzchni a także łatwopalność ograniczały zastosowanie. Obecnie w konstrukcjach inżynierskich coraz częściej wykorzystuje się drewno modyfikowane termicznie oraz materiały drewnopochodne m.in. drewno klejone warstwowo (GL), drewno fornirowane warstwowe (LVL) oraz drewno modyfikowana termicznie (TT). Drewno jest materiałem ulegającym termicznej degradacji. W warunkach oddziaływania wysokich temperatur konstrukcja drewniana jest poddana jednoczesnym wymuszeniom w formie sił oraz oddziaływaniom termicznym. Oddziaływanie tych dwóch czynników wpływa na rozkład naprężeń w strukturze drewna oraz ogranicza nośność konstrukcji, powodując de kohezję struktury. Celem prezentowanych badań było określenie wpływu podwyższonych temperatur na wytrzymałość materiałów drewnianych i drewnopochodnych. Ponadto, na podstawie wyników badań wytrzymałości przeprowadzono analizę prawdopodobieństwa przetrwania w podwyższonych temperaturach. Próbki do badań wytrzymałości na zginanie statyczne zostały wykonane z drewna fornirowego warstwowego - LVL, drewna sosny pospolitej klejonego warstwowo - GL oraz drewna świerkowego poddanego - TT i niepoddanego modyfikacji termicznej - NTT, w formie prostopadłościanów o wymiarach 20x20x300mm. Oceny wytrzymałości na zginanie dokonano na uniwersalnej maszynie wytrzymałościowej FPZ 100/1 (VEB Thuringer Industriewerk Rauenstein, Germany). Temperatury środowiska pożaru symulowano za pomocą nawiewu gorącego powietrza (GHG 650 LCE). Oceny dokonywano w zakresach temperatur: 20, 50, 100, 150, 200, 230±C. Uzyskane wyniki posłużyły ocenie niezawodności. W analizie wykorzystano dwuparametrowy rozkład Weibulla. W przypadku materiałów o strukturze laminowanej - LVL i GL zaobserwowano wzrost odchylenia standardowego wytrzymałości na zginanie w kolejnych zakresach temperatur. Wyższe wartości parametru kształtu c Rozkładu Weibulla zostały wykazane dla świerku TT (najwyższe c = 5.58) i NTT(najwyższe c = 3.31).
Źródło:
Eksploatacja i Niezawodność; 2013, 15, 1; 18-24
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostics of concrete elements after the fire
Diagnostyka elementów betonowych po pożarze
Autorzy:
Plechawski, S.
Fic, S. B.
Powiązania:
https://bibliotekanauki.pl/articles/402539.pdf
Data publikacji:
2018
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
diagnostics
fire temperatures
damage
cracks
fractures
non-destructive testing
destructive testing
strength
dynamic modulus of elasticity
stress intensity factor
diagnostyka
temperatury pożarowe
uszkodzenia
zarysowania
spękania
badania nieniszczące
badania niszczące
wytrzymałość
dynamiczny moduł sprężystości
współczynnik intensywności naprężeń
Opis:
The paper presents selected methods for determining the influence of fire on the load capacity of concrete elements - diagnostics and damages arising after application of fire temperatures. The subject may not seem new in terms of the well-known drop in the strength of concrete in fire conditions, but an important aspect discussed in the paper is the fracture toughness of concrete depending on high temperatures. Destructions, caused by fire temperatures, affects the physical and mechanical properties of concrete, and their size can be assessed using the stress intensity factor. According to our own research, the critical stress intensity factor KIC of concrete decreases faster than the dynamic modulus of elasticity, and also faster than compressive and tensile strength. The paper describes selected methods of diagnostics of construction elements from concrete damaged by fire.
W referacie przedstawiono wybrane metody określania wpływu pożaru na nośność elementów betonowych - diagnostykę oraz uszkodzenia powstające po aplikacji temperatur pożarowych. Temat może nie wydaje się nowy w aspekcie, powszechnie znanego spadku wytrzymałości betonu w warunkach pożarowych, jednak istotnym zagadnieniem poruszonym w referacie jest odporność betonu na pękanie w zależności od wysokich temperatur. Destrukcje powstałe pod wpływem temperatur pożarowych wpływają na właściwości fizykomechaniczne betonu, a ich wielkość może być oceniana za pomocą współczynnika intensywności naprężeń. Z badań własnych wynika, że krytyczny współczynnik intensywności naprężeń KIC betonu zmniejsza się szybciej niż dynamiczny moduł sprężystości Edyn, a także szybciej niż wytrzymałość na ściskanie i rozciąganie. W referacie opisano wybrane metody diagnostyki elementów konstrukcyjnych z betonu, uszkodzonych przez pożar.
Źródło:
Structure and Environment; 2018, 10, 3; 223-236
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laboratoryjna metoda oceny wpływu wysokich temperatur na parametry eksploatacyjne, systemów połączeń żelbetowych
Laboratory method of evaluation of influence high temperatures on maintenance parameters of the reinforced concrete systems compounds
Autorzy:
Bednarek, Z.
Ogrodnik, P.
Pieniak, D.
Powiązania:
https://bibliotekanauki.pl/articles/300737.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
badanie przyczepności
beton zbrojony
spadek przyczepności w warunkach temperatur pożarowych
bond test
reinforced concrete
bond reduction in fire temperature
Opis:
Artykuł prezentuje wyniki badań wpływu temperatur występujących podczas pożaru na przyczepność stali do betonu oraz oszacowanie tego wpływu na spadek przyczepności pomiędzy stalą zbrojeniową i betonem, w warunkach pożaru oraz po przebytym pożarze. W pracy przedstawiono wyniki badań przyczepności stali gładkiej St3S oraz żebrowanej 18G2 do betonu C16/20 i C40/50 w warunkach popożarowych oraz w trakcie trwania pożaru. We wszystkich przebadanych przypadkach stwierdzono znaczący spadek przyczepności betonu do stali zbrojeniowej na skutek oddziaływania temperatur pożarowych. Przebadano również wpływ wytrzymałości betonu oraz gatunku stali (gładka, żebrowana) na spadek przyczepności w temperaturach pożarowych. Udowodniono, że występują istotne różnice przy badaniu przyczepności po pożarze oraz podczas trwania pożaru, które świadczą o częściowym nawrocie przyczepności. Przedmiot badań jest ściśle związany z bezpieczeństwem konstrukcji budowlanych w czasie trwania pożaru, jak i z oceną ich dalszego użytkowania po przebytym pożarze.
The paper presents results from the research on fire temperature influence on steel-concret bond and on the bond reduction for both in-fire status and after-fire status. In the paper has been described bond test and results for materials St3S (smooth), 18G2 (ribbed) reinforcement steel and C16/20, C40/50 concerete, both for in the fire and after-fire conditons. A significant reduction of steel-concrete bond was found as the result of fire temperature. Influence of concrete strength and of rebar type (smooth, ribbed) on the bond reduction in fire temperatures was tested. It was proven that significant bond property differences exist between in-fire tests and after-fire tests, which evidence that the bond is regained partially after the fire exposure. The research subject is closely related to the in-fire construction structures safety as well as with the after-fire construction structures usability evalution.
Źródło:
Eksploatacja i Niezawodność; 2010, 3; 67-78
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fire Resistance of Timber Joints with Steel Fasteners
Autorzy:
Domański, T.
Kmiecik, K.
Powiązania:
https://bibliotekanauki.pl/articles/105572.pdf
Data publikacji:
2018
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
thermal conductivity
fire safety
connections
elevated temperatures
Opis:
Fire safety is a major concern in the design of timber construction. Wood is combustible material. The thermal response of timber connections is usually the main factor in evaluating the overall load-bearing capacity of wood structures exposed to fire. The analysis of timber joints under fire conditions is difficult and complex. Finite element model is developed to predict the thermal behavior of bolted wood-to-wood joints exposed to fire. In fire, the material characteristic depend on the temperature. The thermal model is continuous, taking into account the thermal continuity between the joint components. Also, the thermal model is used to predict the evolution of the temperature field inside the connection. The paper presents a summary of results from a numerical studies of the fire behavior of wood-to-wood timber connections with steel bolt. As a result of computer simulations the temperature distribution was obtained. During fire exposure, the timber section is reduced and steel bolt reduces strength. Loadcarrying capacity per shear plane in fire conditions was calculated using two methods: design methods according to EN 1995-1-1 [5] and reduced load method according to EN 1995-1-2 [6]. In the first approach, the timber section loss and steel strength reduction during the fire were taken into account.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2018, 65, 2; 81-90
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies