Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "OCT" wg kryterium: Wszystkie pola


Tytuł:
Contemporary possibilities in the diagnostics of anterior and posterior eye diseases with the use of new-generation OCT
Współczesne możliwości w diagnostyce chorób przedniego i tylnego odcinka oka przy użyciu OCT nowej generacji
Autorzy:
Paczwa, Katarzyna
Mędrzycka, Justyna
Gołębiewska, Joanna
Różycki, Radosław
Powiązania:
https://bibliotekanauki.pl/articles/2040464.pdf
Data publikacji:
2021-06-21
Wydawca:
Medical Education
Tematy:
OCT
angio-OCT
Opis:
Optical coherence tomography is a non-contact imaging method of the anterior and posterior segments of the eye that is based on laser scanning in spectral domain. This study presents diagnostic possibilities of the new generation Solix FullRange™ OCT&OCTA apparatus (Optovue) to examine meibomian glands, cornea, anterior chamber, as well iridocorneal angles and lens. In the posterior segment of the eye it allows for the precise evaluation of the vitreous body, choroid, retina, optic nerve and blood-flow measurements.
Optyczna koherentna tomografia jest bezkontaktową metodą obrazowania przedniego i tylnego odcinka oka opartą na skaningu laserowym w domenie spektralnej. W niniejszej pracy przedstawiono możliwości diagnostyczne aparatu najnowszej generacji Solix FullRange™ OCT&OCTA (Optovue). Dzięki jego zastosowaniu jest możliwa ocena gruczołów Meiboma, rogówki, kątów przesączania, komory przedniej, a także soczewki. W obrazowaniu tylnego odcinka oka aparat umożliwia dokładne obrazowanie ciała szklistego, siatkówki, naczyniówki oraz nerwu wzrokowego, a także pomiary przepływu naczyniowego.
Źródło:
OphthaTherapy; 2021, 8, 2; 81-86
2353-7175
2543-9987
Pojawia się w:
OphthaTherapy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie angio-OCT w diagnostyce i terapii okulistycznej – część I
Angio-OCT in ophthalmological diagnostics and therapy – part I
Autorzy:
Gołębiewska, Joanna
Hautz, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/1928255.pdf
Data publikacji:
2016
Wydawca:
Medical Education
Tematy:
angio-OCT
choroby naczyniowe
mikrokrążenie siatkówkowe
optyczna koherentna tomografia
Opis:
Angiografia oparta na optycznej koherentnej tomografii (angio-OCT) jest nową, nieinwazyjną metodą obrazowania, umożliwiającą jednoczesną ocenę struktury siatkówki i stanu mikrokrążenia. Metoda ta znalazła zastosowanie w diagnostyce i monitorowaniu chorych ze zwyrodnieniem plamki związanym z wiekiem oraz pacjentów z chorobami naczyniowymi siatkówki, pozwalając na wczesne wykrywanie zmian w obrębie naczyń. Angio-OCT umożliwia ocenę przepływu krwi przez tarczę nerwu wzrokowego i kapilary okołotarczowe, w związku z czym może być użytecznym narzędziem w diagnostyce i monitorowaniu pacjentów z jaskrą.
Optical coherence tomography angiography (angio-OCT) is a new, noninvasive method capable of simultaneously imaging the retinal structure and microvasculature. Angio-OCT is an important tool for diagnostics and for monitoring patients with age-related macular degeneration and different vascular disorders of the retina. It makes it possible to identify early vascular changes and non-perfusion areas. Angio-OCT reveals disturbances in nerve head perfusion and can be a useful technique for diagnosing patients with glaucoma.
Źródło:
OphthaTherapy; 2016, 3, 3; 161-171
2353-7175
2543-9987
Pojawia się w:
OphthaTherapy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie angio-OCT w diagnostyce i terapii okulistycznej – część II
Angio-OCT in ophthalmological diagnostics and therapy – part II
Autorzy:
Gołębiewska, Joanna
Hautz, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/1929141.pdf
Data publikacji:
2016
Wydawca:
Medical Education
Tematy:
angio-OCT
choroby naczyniowe
mikrokrążenie siatkówkowe
optyczna koherentna tomografia
Opis:
Angiografia oparta na optycznej koherentnej tomografii (angio-OCT) jest nową, nieinwazyjną metodą obrazowania, umożliwiającą jednoczesną ocenę struktury siatkówki i stanu mikrokrążenia. Metoda ta znalazła zastosowanie w diagnostyce i monitorowaniu chorych ze zwyrodnieniem plamki związanym z wiekiem oraz pacjentów z chorobami naczyniowymi siatkówki, pozwalając na wczesne wykrywanie zmian w obrębie naczyń. Angio-OCT umożliwia ocenę przepływu krwi przez tarczę nerwu wzrokowego i kapilary okołotarczowe, w związku z czym może być użytecznym narzędziem w diagnostyce i monitorowaniu pacjentów z jaskrą.
Optical coherence tomography angiography (angio-OCT) is a new, noninvasive method capable of simultaneously imaging the retinal structure and microvasculature. Angio-OCT is an important tool for diagnostics and for monitoring patients with age-related macular degeneration and different vascular disorders of the retina. It makes it possible to identify early vascular changes and non-perfusion areas. Angio-OCT reveals disturbances in nerve head perfusion and can be a useful technique for diagnosing patients with glaucoma.
Źródło:
OphthaTherapy; 2016, 3, 4; 254-259
2353-7175
2543-9987
Pojawia się w:
OphthaTherapy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optyczna koherentna tomografia OCT - nowe narzędzie do działań konserwatorskich i inwentaryzacyjnych
Optical coherence tomography OCT - a novel tool for art conservation and cataloguing
Autorzy:
Targowski, P.
Rouba, B.J.
Karaszkiewicz, P.
Iwanicka, M.
Tymińska-Widmer, L.
Łękawa-Wysłouch, T.
Kwiatkowska, E.A.
Sylwestrzak, M.
Powiązania:
https://bibliotekanauki.pl/articles/217772.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Konserwatorów Zabytków
Tematy:
tomografia OCT
konserwacja
inwentaryzacja
OCT tomography
cataloguing
conservation
Opis:
Przedstawione zostaną przykłady obrazowania stratygrafii obrazów olejnych, w tym również w zastosowaniu do oceny autentyczności inskrypcji lub sygnatur. Poza tym omówione zostanie wykorzystanie OCT jako narzędzia wspomagającego stratygrafię LIBS, jak również do oceny zakresu korozji hydrologicznej szkła witrażowego oraz do monitorowania reakcji obiektu (obrazu) na zmianę warunków klimatycznych w jego otoczeniu.
An application of OCT - a noninvasive diagnostic tool for examination of objects of art is discussed on the examples taken from research conducted at Nicolaus Copernicus University in Toruń, Poland. The following subjects have been discussed: stratigraphy of oil paintings on canvas, its specific application to analysis of order and authenticity of inscriptions on paintings, 'absolute' LIBS stratigraphy - OCT aided, application of OCT for examination of corrosion of stained glass, and monitoring of environmental induced deformations of canvas supports.
Źródło:
Wiadomości Konserwatorskie; 2009, 26; 94-107
0860-2395
2544-8870
Pojawia się w:
Wiadomości Konserwatorskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Shall intraoperative OCT become standard equipment of modern operating room?
Autorzy:
Kaczmarek, Dorota Maria
Kaczmarek, Radosław
Powiązania:
https://bibliotekanauki.pl/articles/23202392.pdf
Data publikacji:
2023-09-30
Wydawca:
Medical Education
Tematy:
intraoperative OCT
retinal surgery
corneal surgery
vitrectomy
keratoplasty
Opis:
The role of intraoperative OCT (iOCT) in ophthalmic surgery is still a matter of active research and enhancements to integrative technologies. Further research is necessary to better define the specific applications of iOCT that impact surgical decision-making and as such help to achieve better patient outcomes, both in anterior and in posterior segment of the eye. In time to come advancements in integrative systems, OCT-friendly instrumentation, and software algorithms will most likely expand the horizon of iOCT even further.
Źródło:
OphthaTherapy; 2023, 10, 3; 173-177
2353-7175
2543-9987
Pojawia się w:
OphthaTherapy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Denoising methods for improving automatic segmentation in OCT images of human eye
Autorzy:
Stankiewicz, A.
Marciniak, T.
Dąbrowski, A.
Stopa, M.
Rakowicz, P.
Marciniak, E.
Powiązania:
https://bibliotekanauki.pl/articles/201133.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
optical coherence tomography (OCT)
image denoising
image segmentation
anisotropic diffusion
wavelet thresholding
koherentna tomografia optyczna
OCT
segmentacja obrazu
dyfuzja anizotropowa
Opis:
This paper presents analysis of selected noise reduction methods used in optical coherence tomography (OCT) retina images (the socalled B-scans). The tested algorithms include median and averaging filtering, anisotropic diffusion, soft wavelet thresholding, and multiframe wavelet thresholding. Precision of the denoising process was evaluated based on the results of automated retina layers segmentation, since this stage (vital for ophthalmic diagnosis) is strongly dependent on the image quality. Experiments were conducted with a set of 3D low quality scans obtained from 10 healthy patients and 10 patients with vitreoretinal pathologies. Influence of each method on the automatic image segmentation for both groups of patients is thoroughly described. Manual annotations of investigated retina layers provided by ophthalmology experts served as reference data for evaluation of the segmentation algorithm.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2017, 65, 1; 71-78
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Examination of Sol-Gel Derived Hydroxyapatite Enhanced with Silver Nanoparticles using OCT and Raman Spectroscopy
Autorzy:
Głowacki, M. J.
Gnyba, M.
Strąkowska, P.
Gardas, M.
Kraszewski, M.
Trojanowski, M.
Strąkowski, M. R.
Powiązania:
https://bibliotekanauki.pl/articles/221475.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
hydroxyapatite
sol-gel
nanoparticles
Raman spectroscopy
optical coherence tomography (OCT)
Opis:
Hydroxyapatite (HAp) has been attracting widespread interest in medical applications. In a form of coating, it enables to create a durable bond between an implant and surrounding bone tissues. With addition of silver nanoparticles HAp should also provide antibacterial activity. The aim of this research was to evaluate the composition of hydroxyapatite with silver nanoparticles in a non-destructive and non-contact way. For control measurements of HAp molecular composition and solvent evaporation efficiency the Raman spectroscopy has been chosen. In order to evaluate dispersion and concentration of the silver nanoparticles inside the hydroxyapatite matrix, the optical coherence tomography (OCT) has been used. Five samples were developed and examined ‒ a reference sample of pure HAp sol and four samples of HAp colloids with different silver nanoparticle solution volume ratios. The Raman spectra for each solution have been obtained and analyzed. Furthermore, a transverse-sectional visualization of every sample has been created and examined by means of OCT.
Źródło:
Metrology and Measurement Systems; 2017, 24, 1; 153-160
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improving Segmentation of 3D Retina Layers Based on Graph Theory Approach for Low Quality OCT Images
Autorzy:
Stankiewicz, A.
Marciniak, T.
Dąbrowski, A.
Stopa, M.
Rakowicz, P.
Marciniak, E.
Powiązania:
https://bibliotekanauki.pl/articles/221548.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Optical Coherence Tomography (OCT)
segmentation of retinal layers
image segmentation
graph theory
Opis:
This paper presents signal processing aspects for automatic segmentation of retinal layers of the human eye. The paper draws attention to the problems that occur during the computer image processing of images obtained with the use of the Spectral Domain Optical Coherence Tomography (SD OCT). Accuracy of the retinal layer segmentation for a set of typical 3D scans with a rather low quality was shown. Some possible ways to improve quality of the final results are pointed out. The experimental studies were performed using the so-called B-scans obtained with the OCT Copernicus HR device.
Źródło:
Metrology and Measurement Systems; 2016, 23, 2; 269-280
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Miejsce powstania i historia pasjonału theol. lat. oct. 162 ze zbiorów Biblioteki Państwowej w Berlinie
Autorzy:
Sosnowski, Miłosz
Powiązania:
https://bibliotekanauki.pl/articles/603579.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Instytut Historii im. Tadeusza Manteuffla PAN w Warszawie
Tematy:
Brunon z Kwerfurtu
Pięciu Braci Męczenników
kodykologia
paleografia
theol. lat. oct. 162
Huysburg
skryptorium
Biblioteka Państwowa w Berlinie
hagiografia
Bruno of Querfurt
Five Brothers
codicology
palaeography
scriptorium
Staatsbibliothek Berlin
hagiography
Opis:
Zarys treści: Artykuł poświęcony jest pochodzeniu i historii kodeksu ze zbiorów Biblioteki Państwowej w Berlinie, opatrzonego sygnaturą theol. lat. oct. 162. Kodeks ten zawiera jedyną znaną kopię Vita Quinque Fratrum autorstwa Brunona z Kwerfurtu. Druga część pracy poświęcona jest próbie rekonstrukcji drogi, za sprawą której tekst znalazł się w bibliotece klasztornej w Huysburgu.Abstract: The article deals with the origin and history of a codex from the collections of the Berlin State Library (call no. theol. lat. oct. 162). The codex contains the only known copy of Vita Quinque Fratrum by Bruno of Querfurt. The second part of the article aims at reconstruction of the history of the text itself before the aquisition of the copy by the Huysburg abbey library.
Codex theol. lat. oct. 162 (Staatsbibliothek Berlin) plays an important role in Polish medieval studies due to its containing the sole witness of Vita Quinque Fratrum (BHL 1147) by Bruno of Querfurt. The article traces history of the codex from the origin until its discovery in the family library of Reinhard Kade, the first editor of VQF. The oldest part of the codex is a passionale (12/13th cent.), which was written at (or at least very early belonged to) the Benedictine monastery in Huysburg. In the 15th century – still in Huysburg – it was bound together with two later unrelated manuscripts to form the current composite codex. During the secularization of the monastery at the beginning of the 19th century it came into possession of Friedrich Gottlieb Julius von Bülow (1760–1831), an assessor and book collector. After von Bülow’s death his collection was put up at auction, the printed catalogue of which lists our manuscript. The codex was bought by Kade’s paternal grandfather, Anton Krüger of Dresden a noted engraver. The rest of manuscript’s history is well known. The second part of the article examines a couple of hypothetical routes, through which the source copy for our witness (i.e. a very early copy or even Bruno’s draft) or the witness itself could have been transferred to Huysburg, by tracing both direct and indirect connections of Querfurt counts and the monastery. Those hypothetical routes from Querfurt (Eilversdorf monastery?) to Huysburg – both in the diocese of Halberstadt – also try to make sense of the apparent interest that the passionale compiler had taken in Magdeburg.A brief addendum discusses the implications of the re-discovery of a codex from Ebrach, previously considered lost, that was suspected by G. Waitz to be identical with our witness or, by W. Kętrzyński and W. Meysztowicz, to be a source for Cosmas’ of Prague version of Five Brothers text. Late in the publishing process the author became aware the new description of theol. lat. oct. 162 (Beate Braun-Niehr, Manuscripta Mediaevalia database: <http://www.manuscripta-mediaevalia.de/dokumente/html/obj31101702> [access: 29.09.2016]. This new description independently and concisely provides some of the article’s findings (ownership note from Huysburg, auction catalogue of „Bibliotheca Büloviana”, lost codex of EbrachNepomuk). Still available is the previous catalogue description, which was known to the author in February 2014, during the autopsy of Huysburg codices in Berlin <http://www.manuscripta-mediaevalia.de/ dokumente/html/obj90432270,T> [access: 29.09.2016].
Źródło:
Studia Źródłoznawcze. Commentationes; 2016, 54
0081-7147
Pojawia się w:
Studia Źródłoznawcze. Commentationes
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cross-Sectional Imaging of Materials Structure Using PS-OCT
Autorzy:
Strąkowski, M.
Pluciński, J.
Kosmowski, B.
Powiązania:
https://bibliotekanauki.pl/articles/1811558.pdf
Data publikacji:
2008-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.79.-e
42.87.-d
Opis:
Optical low-coherence tomography is a measurement technique for non-contact and non-destructive investigation of materials inner structure. Nowadays, this method is highly applied in medical treatment especially in dermatology and ophthalmology. During our research we have developed an optical low-coherence tomography system with polarization state analysis for structure examination of a broad range of technical materials. In this paper we present our recent measurements including polarization sensitive analysis. Those measurements were taken for semitransparent and highly scattering materials like polymer layers and polymer optical retarders, anticorrosion protective coatings or abrasive paper. We proved that with the aid of developed polarization sensitive optical coherence tomography system it is possible to investigate birefringence principles of materials as well as to improve visualization contrast of cross-sectional images.
Źródło:
Acta Physica Polonica A; 2008, 114, 6A; A-217-A-221
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methods of Information Extraction from OCT Images
Autorzy:
Zajac, A.
Urbański, Ł.
Kasprzak, J.
Kecik, D.
Powiązania:
https://bibliotekanauki.pl/articles/1493300.pdf
Data publikacji:
2011-10
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.57.-s
42.79.Qx
42.30.Wb
Opis:
Optical diagnostic methods of biological media are more and more willingly used in clinical practice - also instead of classical biopsy. Particularly, optical coherent tomography methods and mammography (permitting achieving three-dimensional imaging of a tissue) are attractive in comparison with classical diagnostic methods. The article presents the analysis methods of optical parameters of biological tissues developed allowing obtaining absolute values of these parameters. Thanks to modern image analysis methods - wavelet transforms - the optical diagnostic effectiveness was improved. The theoretical and practical results achieved were compared with results of commercially accessible methods implemented in OCT devices.
Źródło:
Acta Physica Polonica A; 2011, 120, 4; 772-775
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Forum ophthalmicum - how to take control over accumulation of diagnostic data from macular OCT with benefit for both doctor and patient?
Forum ophthalmicum – jak uporządkować natłok informacji z badania OCT plamki z korzyścią dla lekarza i pacjenta?
Autorzy:
Kaczmarek, Dorota Maria
Powiązania:
https://bibliotekanauki.pl/articles/2040407.pdf
Data publikacji:
2021-09-30
Wydawca:
Medical Education
Tematy:
wAMD
optical coherent tomography
anti-VEGF therapy
medical data analysis
optyczna koherentna tomografia
terapia anty-VEGF
analiza danych medycznych
Opis:
Wet age-related macular degeneration (wet AMD) is a disease which requires regular diagnostic tests such as macular optical coherent tomography which is extremely important both in diagnosis and disease monitoring. With constant aging of the population, we are dealing with an increasing incidence rate of AMD, which makes it even more important to have a tool allowing for quick and precise analysis of anatomical changes in macular region, particularly in the current complicated epidemiological situation when diagnostic time should be used most efficiently to plan the follow-up treatment. Forum® software allows for the precise analysis of many tests performed in a single patient and combining it with treatment effectiveness assessment which substantially accelerates the diagnostics.
Wysiękowa postać zwyrodnienia plamki związanego z wiekiem to schorzenie, które wymaga regularnej diagnostyki okulistycznej, głównie w postaci okresowo wykonywanej optycznej koherentnej tomografii plamki. Rola tego badania jest niezmiernie ważna zarówno w procesie diagnostyki, jak i monitorowania. Jako że wraz ze starzeniem się populacji mamy do czynienia ze wzrostem zachorowalności na wysiękową postać zwyrodnienia plamki związanego z wiekiem, coraz bardziej istotna staje się potrzeba szybkiej i precyzyjnej analizy zmian anatomicznych obszaru plamkowego, tak aby w dodatkowo skomplikowanej sytuacji epidemiologicznej maksymalnie efektywnie wykorzystać czas przeznaczony na diagnostykę oraz zaplanować dalsze etapy leczenia. Dzięki oprogramowaniu o nazwie Forum® zyskujemy możliwość precyzyjnej analizy wielu badań wykonanych u danego pacjenta, łącznie z oceną skuteczności leczenia na przestrzeni czasu, co znacznie przyspiesza procesy diagnostyczne.
Źródło:
OphthaTherapy; 2021, 8, 3; 160-165
2353-7175
2543-9987
Pojawia się w:
OphthaTherapy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Common path optical coherence tomography with electronic feedback for improved sensitivity
Autorzy:
Alsnaie, Khalid
Powiązania:
https://bibliotekanauki.pl/articles/27310102.pdf
Data publikacji:
2023
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
optical coherence tomography
frequency domain
OCT
medical imaging
partially coherent interferometers
B-scan
Opis:
Optical coherence tomography (OCT) imaging has become a useful tool in medical diagnosis over the past 25 years, because of its ability to visualize intracellular structures at high resolution. The main objective of this work is to add electronic feedback to the optical coherence tomography setup to increase its sensitivity. Noise added to the measured interferogram obscures some details of examined tissue layered structure. Adjusting signal power level in such a way to improve signal-to-noise ratio can help to enhance image quality. Electronic feedback is added to enhance system sensitivity. A logarithmic amplifier is included in the OCT setup to automatically adapt signal level. Moreover, the resolution of the optical spectrum analyzer is controlled according to the farthest layer detected in the A-scan. These techniques are tested showing an improvement in obtained image of a human nail.
Źródło:
Optica Applicata; 2023, 53, 3; 495--504
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optical Fourier Domain Interferometry as a novel tool for biological imaging
Autorzy:
Rumiński, D.
Kowalczyk, A.
Wojtkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/1396523.pdf
Data publikacji:
2011
Wydawca:
Fundacja na Rzecz Młodych Naukowców
Tematy:
OFDI
swept source
OCT
medical imaging
eye imaging
Michelson interferometer
interferometry
Opis:
Purpose of this work is to introduce results of biological objects measurements with Optical Coherence Tomography system working with swept source laser (OFDI system). This specified source with spectrum centred around 1040 nm is dedicated to measure posterior segment of the eye. OCT with this wavelength is expected to be next generation for this sort of systems. Although commonly used 800 nm source enables imaging retina, deeper tissue layers are not available with this wavelength. Longer wavelengths in range of infrared spectrum (e.g. 1040 nm) are being weakly scattered which enables to go down to the choroid layer [1]. Examination this structure composed mostly from blood vessels might be very important for early diagnosis of eye diseases. In this paper system setup, swept source scheme and eye images would be introduced.
Źródło:
Challenges of Modern Technology; 2011, 2, 1; 16-18
2082-2863
2353-4419
Pojawia się w:
Challenges of Modern Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obecne techniki biometrii oka
Current technologies of ocular biometry
Autorzy:
Turczynowska, Magdalena
Koźlik-Nowakowska, Katarzyna
Gaca-Wysocka, Magdalena
Grzybowski, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/1928252.pdf
Data publikacji:
2016
Wydawca:
Medical Education
Tematy:
OLCR
PCI
SS-OCT
biometria oka
biometria optyczna
biometry optyczne
Opis:
Operacja zaćmy jest obecnie najczęściej wykonywaną procedurą chirurgiczną w krajach rozwiniętych. Coraz częściej traktowana jest również jako zabieg refrakcyjny, a zastosowanie soczewek z grupy premium (asferycznych, torycznych, wieloogniskowych) pozwala pacjentowi na uniezależnienie się od korekcji okularowej i uzyskanie dobrej jakości widzenia do wszystkich odległości, nawet jeśli przed zabiegiem występowały starczowzroczność czy astygmatyzm. Wraz z poprawą standardów leczenia operacyjnego zwiększają się również oczekiwania pacjentów. Kluczowe jest uzyskanie jak najlepszej refrakcji pooperacyjnej. W tym celu przed operacją należy dokonać precyzyjnych pomiarów biometrycznych gałki ocznej i wybrać optymalną formułę obliczeniową do kalkulacji mocy wszczepianej soczewki. Celem pracy jest przedstawienie aktualnych metod przeprowadzania badań biometrycznych i najnowszych dostępnych w Polsce aparatów służących do biometrii oraz porównanie ich funkcji. Dokładne zrozumienie zalet i ograniczeń dostępnej na rynku aparatury oraz poznanie podstawowych zasad kalkulacji mocy wszczepianych soczewek pozwoli usprawnić procedury przeprowadzania badań i osiągać optymalne wartości refrakcji pooperacyjnej.
Cataract surgery is currently the most frequently performed surgical procedure in developed countries. In some cases it is also regarded as refractive procedure, and the use of premium intraocular lenses (aspheric, toric, multifocal) allows the patient to become spectacle independent. The improvement of surgical treatment results in rising expectations of patients. The key issue is to achieve the desired refractive outcome. Essential for this purpose are precise measurements of the eye, and selection of the optimal IOL calculation formula. The aim of this paper is to present current techniques of ocular biometry and new biometry devices available in Poland, along with a comparison of their functions. Good understanding the advantages and limitations of the current technology allows to perform measurements efficiently and to achieve highly accurate refractive outcomes.
Źródło:
OphthaTherapy; 2016, 3, 2; 132-138
2353-7175
2543-9987
Pojawia się w:
OphthaTherapy
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies