Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "wastewater treatment efficiency" wg kryterium: Temat


Tytuł:
Activated Sludge Technology Combined With Hydroponic Lagoon as a Technology Suitable for Treatment of Wastewater Delivered by Slurry Tanks
Autorzy:
Pawęska, K.
Bawiec, A.
Powiązania:
https://bibliotekanauki.pl/articles/125019.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
activated sludge technology
hydroponic lagoon
wastewater delivered by slurry tanks
wastewater treatment efficiency
Opis:
The paper presents information related to the use of hydrophytic technology combined with traditional activated sludge solution for wastewater treatment in areas without central sewage system. The analyzed wastewater treatment plant (WWTP) was operated in activated sludge technology with a hybrid activated sludge reactor where biomass is kept in a settled and suspended form. Treatment system was completed with a hydroponic lagoon. Hydroponic lagoon has been used as tertiary treatment, in which the self-cleaning processes with the participation of the plant has come to an additional reduction of nutrients. The analyzed three-stage treatment plant is located in the municipality of Nowa Sól. Only domestic wastewater delivered by slurry tanks is treated there in the amount of 60 m3/d. During the observation, high average concentrations of total nitrogen (201.0 mgN/dm3) was observed and organic matter expressed by COD reaching 1341.5 mgO2/dm3 and BOD5 on the level of 246.3 mgO2/dm3 were noted. A characteristic feature of the object designed for wastewater treatment delivered by slurry tanks is high irregularity of wastewater supply and high instantaneous loads of pollutants (the system does not provide expansion tank). The biggest inequality factor of the flow to the reactor was observed in December 2014 (Nd=3.9). During the observations days with no inflow of sewage also occurred. The study shows the dynamics of changes in the amount of delivered domestic wastewater and sewage flowing out of the treatment plant including inequality factor. Information about the quality of wastewater was used to determine the reduction of concentrations of pollutants such as organic matter, suspended solids, nitrogen and phosphorus.
Źródło:
Journal of Ecological Engineering; 2017, 18, 2; 29-37
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Operating household wastewater treatment plants in the light of binding quality standards for wastewater discharged to water bodies or to soil
Użytkowanie przydomowych oczyszczalni ścieków w świetle obowiązujących standardów jakości ścieków odprowadzanych do wód lub do ziemi
Autorzy:
Jawecki, B.
Pawęska, K.
Sobota, M.
Powiązania:
https://bibliotekanauki.pl/articles/946891.pdf
Data publikacji:
2017
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
administrative decision
agglomeration
household wastewater treatment plant
sanitary sewage
stopping the operation of installation
wastewater treatment efficiency
aglomeracja
decyzja administracyjna
kanalizacja sanitarna
przydomowa oczyszczalnia ścieków
skuteczność oczyszczania ścieków
wstrzymanie eksploatacji instalacji
Opis:
The study presents the legal requirements concerning the quality of wastewater discharged to waterbodies and to soil after treatment in household wastewater treatment plants located in agglomerations or outside them. The procedure of stopping the operation of a household treatment plant that doesn't meet the statutory wastewater treatment efficiency was presented. The decision ordering to stop the use of a household wastewater treatment plant has to be preceded by a decision ordering to take measures to limit its adverse impact on the environment. The clarification procedure has to determine the adverse impact on the environment in a doubtless manner and it has to be reflected in the documentation. The assessment of adverse impact should take into account the binding standards of use of the environment. Stopping the operation of a household wastewater treatment plant may result in issuing a decision ordering the user to connect to the sanitary sewage system.
W pracy przedstawiono wymogi prawne, dotyczące jakości ścieków wprowadzanych do wód i do ziemi po oczyszczeniu w przydomowych oczyszczalniach ścieków zlokalizowanych na terenie aglomeracji lub poza nią. Wskazano procedurę wstrzymania eksploatacji przydomowej oczyszczalni ścieków, w sytuacji gdy nie spełnia ona wymaganej przepisami skuteczności oczyszczania ścieków. Decyzja o wstrzymaniu eksploatacji przydomowej oczyszczalni ścieków musi być poprzedzona decyzją nakazującą ograniczenie negatywnego oddziaływania przydomowej oczyszczalni ścieków na środowisko. Postępowanie wyjaśniające negatywne oddziaływanie na środowisko musi zostać stwierdzone w sposób niebudzący wątpliwości oraz znajdować odzwierciedlenie w dokumentacji postępowania, a ocena negatywnego oddziaływania na środowisko powinna uwzględniać obowiązujące standardy korzystania ze środowiska. Konsekwencją wstrzymania eksploatowanej przydomowej oczyszczalni może być wydanie decyzji nakazującej podłączenie się do kanalizacji sanitarnej.
Źródło:
Journal of Water and Land Development; 2017, 32; 31-39
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the sewage treatment system of the Silesian agglomeration
Analiza systemu oczyszczania ścieków miasta aglomeracji Śląskiej
Autorzy:
Stankowska, P.
Standera, J.
Kwiatkowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/127491.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
wastewater treatment plant
efficiency of wastewater treatment technology
oczyszczalnia ścieków
skuteczność technologii oczyszczania ścieków
Opis:
The construction of the technological treatment plant is closely related to the amount and physicochemical parameters of incoming sewage. The economic aspects and the principles of sustainable development also should be taken into account at the stage of sewage treatment plant construction planning. Moreover, in large cities, there is often greater number of sewage treatment plants, which should create an effective system for wastewater treatment. Municipal wastewater treatment system should not disturb the ecological balance of the area and cannot contribute to the deterioration of the living conditions of people (especially those living in the immediate vicinity of the sewage treatment plant). The paper compares the process lines of three wastewater treatment plants located in the city of Bytom: “Centralna” plant, “Miechowice” plant and “Bobrek” plant. The paper also compares the main indicators of the efficiency of the described wastewater treatment plants and the selected parameters of the sewage sludge. Based on the above data, an attempt was made to assess the proper operation of the sewage treatment system in the city of Bytom.
Budowa ciągu technologicznego oczyszczalni jest ściśle powiązana z ilością i parametrami fizykochemicznymi dopływających ścieków. Na etapie planowania należy rozważyć także kryteria zrównoważonego rozwoju oraz aspekty ekonomiczne. Ponadto, w dużych miastach na skuteczny system oczyszczania ścieków składa się często większa liczba oczyszczalni. Miejski system oczyszczania ścieków nie może zakłócać równowagi ekosystemowej danego obszaru ani przyczyniać się do pogorszenia warunków bytowania ludzi (szczególnie tych mieszkających w bezpośrednim sąsiedztwie oczyszczalni ścieków). W artykule porównano ciągi technologiczne trzech oczyszczalni ścieków znajdujących się na terenie miasta Bytom: Oczyszczalni „Centralna”, Oczyszczalni „Miechowice” oraz Oczyszczalni „Bobrek”. Zestawiono także główne wskaźniki efektywności oczyszczania oraz niektóre parametry osadu czynnego. Na podstawie powyższych danych podjęto próbę oceny prawidłowego funkcjonowania systemu oczyszczania ścieków w Bytomiu.
Źródło:
Proceedings of ECOpole; 2016, 10, 2; 511-516
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of wastewater treatment efficiency in Wolbrom
Autorzy:
Gawron, M.
Łukasiewicz, M.
Malinowski, M.
Salamon, J.
Powiązania:
https://bibliotekanauki.pl/articles/101059.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
wastewater treatment plant
efficiency
wastewater treatment
Opis:
The study was conducted to assess the effectiveness of wastewater treatment at the municipal wastewater treatment plant in Wolbrom, to which predominantly domestic wastewater and industrial sewage flow. The assessment was made based on the analysis of the physical and chemical research results of raw and treated wastewater. The research was carried out in the period from January 2014 to December 2014. To perform the analysis of the treatment plant efficiency, four indicators of wastewater pollutants such as BOD5 , COD, total nitrogen and total phosphorus were selected for further investigation. For each of the indicators degrees of reduction and coefficients of treatment plant operational reliability were calculated. The calculated degrees of reduction for each of the indicators were high and amounted to 99.0% for BOD5 , 95.2% for COD, 91.0% for total nitrogen and 91.6%. for total phosphorus. These results prove the effective reduction in the amount of pollutants. The determined coefficients of treatment plant operational reliability were at a low level: BOD5 - 0.27, COD - 0.44, total nitrogen - 0.33 and total phosphorus - 0.53. The conducted analyses prove the effective operation of the treatment plant, which was confirmed by high efficiency of pollutants removal.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, IV/4; 1889-1897
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność pracy oczyszczalni ścieków w gminie Kaczory
Operational efficiency of wastewater treatment plant in Kaczory
Autorzy:
Stankiewicz, Monika
Stankiewicz, Bartłomiej
Powiązania:
https://bibliotekanauki.pl/articles/2097848.pdf
Data publikacji:
2020
Wydawca:
Zachodniopomorska Szkoła Biznesu w Szczecinie
Tematy:
oczyszczalnia ścieków
redukcja zanieczyszczeń
technologia oczyszczania ścieków
efektywność pracy oczyszczalni ścieków
właściwości fizykochemiczne ścieków
wastewater treatment plant
reduction of pollutions
wastewater treatment technology
efficiency of wastewater treatment plants
physicochemical properties of wastewater
Opis:
Celem niniejszego artykułu jest ocena efektywności pracy oczyszczalni ścieków w Kaczorach po przebudowie na podstawie wyników badań fizykochemicznych ścieków surowych oraz ścieków oczyszczonych. Dane pomiarowe zbierano od momentu zakończenia prac budowlanych w 2017 roku. W pracy przeanalizowano wskaźniki zanieczyszczeń zebrane do 2020 roku, a w oparciu o uzyskane wyniki uzyskano potwierdzenie, że przebudowana oczyszczalnia funkcjonuje w sposób prawidłowy i wysoce wydajny.
The purpose of this article is evaluation of work efficiency of wastewater treatment plant in Kaczory after reconstruction, based on the results of physicochemical tests of raw wastewater and treated wastewater. Measurement data was collected since the completion of construction works in 2017. The study analyzed the collected pollution indicators in the period to 2020 year and on the basis of the obtained results, it was confirmed that the rebuilt sewage treatment plant is functioning properly and highly efficiently.
Źródło:
Zeszyty Naukowe ZPSB Firma i Rynek; 2020, 2(58); 36-51
2657-3245
Pojawia się w:
Zeszyty Naukowe ZPSB Firma i Rynek
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena skuteczności pracy oczyszczalni ścieków w Gryfinie
Efficiency of sewage treatment plant in Gryfino
Autorzy:
Szczerbińska, N.
Gałczyńska, M.
Ulas, K.
Burczyk, P.
Mikołajczak, M.
Buśko, M.
Powiązania:
https://bibliotekanauki.pl/articles/339125.pdf
Data publikacji:
2018
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
efektywność oczyszczania ścieków
oczyszczalnia ścieków
ścieki oczyszczone
ścieki surowe
efficiency of wastewater treatment purified sewage
raw sewage
sewage treatment plant
Opis:
Polska – wchodząc w struktury Unii Europejskiej – zobowiązała się do uporządkowania gospodarki ściekowej do końca 2015 r. Dzięki prawidłowej pracy oczyszczalni ścieki odprowadzane do wód odbiornika nie stanowią dla nich zagrożenia. Jest to szczególnie ważne ze względu na potrzebę utrzymania dobrego stanu wód powierzchniowych. Celem badań było określenie efektywności oczyszczania ścieków przez mechaniczno-biologiczną oczyszczalnię ścieków w Gryfinie na podstawie analizy ilości zanieczyszczeń niesionych wraz ze ściekami komunalnymi. Badania przeprowadzono na terenie oczyszczalni ścieków w Gryfinie. Analizy składu ścieków surowych i oczyszczonych obejmowały pięcioletni okres – od 2011 do 2015 r. Analizowano BZT5, ChZT, zawiesinę ogólną, Nog i Pog. Obliczono efektywność pracy oczyszczalni ścieków, skuteczność zmniejszania zanieczyszczeń i wskaźnik technologicznej sprawności oczyszczania. Wyniki badań opracowano statystycznie. Stwierdzono, że średni wskaźnik sprawności oczyszczania ścieków w odniesieniu do zawiesiny ogólnej wyniósł 98,0%, BZT5 – na poziomie 98,9%, natomiast ChZT – na poziomie 97,4%. Średni wskaźnik sprawności oczyszczania ścieków w odniesieniu do azotu ogólnego oraz fosforu ogólnego wyniósł odpowiednio 89,6% i 96,4%. Ustalono, że efektywność oczyszczalnia ścieków w Gryfinie była bardzo duża i zgodna z przepisami.
Poland entering the structures of the European Union committed itself to organize wastewater management by the end of 2015. Due to the correct operation of the sewage treatment plant, the sewage discharged into the receiver water does not pose any danger to them. This is especially important because of the need to maintain good surface water quality. The aim of the study was to analyse the amount of pollutants transported with municipal wastewater, to determine the efficiency of wastewater treatment by mechanical-biological sewage treatment plant in Gryfino. The research was carried out on the sewage treatment plant in Gryfino. Analyses of raw and purified wastewater were carried on a five year period from 2011 to 2015. BOD5, COD, general suspension, total nitrogen and total phosphorus were analyzed. The efficiency of sewage treatment plant operation, efficiency of pollution reduction and the technological wastewater treatment efficiency rate were calculated. The results of the research were statistically analyzed. It was found that the average wastewater treatment efficiency rate for the total suspended solids was 98.0%, and BOD5 – 98.9%, and COD – 97.4%. The average efficiency index of wastewater treatment for total nitrogen and total phosphorus was 89.6% and 96.4% respectively. It was found that the efficiency of the wastewater treatment plant in Gryfino was very good and consistent with the regulations.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2018, 18, 2; 85-98
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of the Scheme of the Installation for Mechanical Wastewater Treatment
Autorzy:
Sevostianov, Ivan V.
Ivanchuk, Yaroslav V.
Polishchuk, Oleksandr V.
Lutsyk, Vladyslav L.
Dobrovolska, Kateryna V.
Smailova, Saule
Wójcik, Waldemar
Kalizhanova, Aliya
Powiązania:
https://bibliotekanauki.pl/articles/1839562.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
industrial wastewater
domestic wastewater
continuous mechanical treatment
installation
efficiency
Opis:
The paper presents the schemes of various equipment for the mechanical treatment of the industrial and domestic wastewater, which allows removing it from the main part of the pollution. An examination of the shortcomings of the known equipment with the aim of its improvement was conducted. As a result, an installation scheme for continuous high-performance mechanical wastewater treatment was proposed. In contrast to the known equipment, the proposed installation provides a three-staged treatment of wastewater with the help of the two pairs of gratings – for preliminary treatment (removal of large-size pollutions) and by filtration through the two metallic sieves – for normal and fine treatment (removal of small-size mechanical pollutions). The installation consists of highly-efficient appliances for the cleaning of filtering elements in the course of realization of the working process, which provides stable high productivity of treatment. The installation has simple reliable design and low energy expenses. The paper contains the formulas for determining of main operational parameters of the installation: the change of the cross-sectional area of the filtering elements and productivity of the working process, periodicity of cleaning of gratings and sieves, the necessary electric power of installations drives. These formulas can be a basis for further research of installation and for elaboration of a method of its design calculation.
Źródło:
Journal of Ecological Engineering; 2021, 22, 1; 20-28
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Unieszkodliwianie ścieków z obiektów użyteczności publicznej na terenach niezurbanizowanych
Neutralizing wastewater from public utilities on rural areas
Autorzy:
Bugajski, P.
Chmielowski, K.
Kurek, K.
Powiązania:
https://bibliotekanauki.pl/articles/950007.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ścieki
oczyszczanie
skuteczność
wastewater
treatment plants
efficiency
Opis:
Celem badań było określenie możliwości wykorzystania przydomowych oczyszczalni ścieków, których reaktory biologiczne pracują w technologii osadu czynnego do unieszkodliwiania zanieczyszczeń odprowadzanych ze szkół na terenach wiejskich. Na podstawie wybranych wskaźników zanieczyszczeń takich jak: BZT , ChZT, zawiesina ogólna, azot ogólny oraz fosforany scharakteryzowano skład ścieków surowych odpływających z obiektów użyteczności publicznej oraz jakość ścieków oczyszczonych z podziałem na dni z zajęciami szkolnymi i dni wolne od zajęć. Analiza wyników badań wykazała, iż dla potrzeb unieszkodliwiania ścieków z obiektów użyteczności publicznej takich jak szkoły; można stosować przydomowe oczyszczalnie ścieków, których działanie oparte jest na osadzie czynnym.
The research aimed at determining a potential use of domestic sewage treatment plants based on activated sludge for the disposal of wastes drained from schools in rural areas. Selected pollutant indicators, such as: BOD , COD, total suspended solids, total nitrogen and phosphates were the basis for determining the composition of raw sewage discharged by public utility objects and the quality of treated sewage considering the days when lessons were taking place at school and days free from classes. The analysis of the results revealed that household sewage treatment plants based on activated sludge may be used for waste disposal from public facilities, such as schools.
Źródło:
Inżynieria Ekologiczna; 2015, 44; 178-183
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis and Assesment of the Wastewater Treatment Plant Operation in the City of Kłodzko
Autorzy:
Garbowski, T.
Wiśniewski, J.
Bawiec, A.
Powiązania:
https://bibliotekanauki.pl/articles/125373.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wastewater treatment system
sewage treatment efficiency
WWTP
treatment plant reliability factor
Opis:
In this study, the current operation efficiency of the wastewater treatment plant (WWTP) in the city of Kłodzko in the Lower Silesia Voivodeship (Poland) was analyzed and the predicted amount of the wastewater flowing to the WWTP in a 20-year period (until the year 2036) was estimated. The data on the quality and the quantity of raw (entering to the WWTP) and treated sewage from the years 2012-2016 were analyzed. The five essential pollutants indicators: biochemical oxygen demand (BOD5), chemical oxygen demand (CODCr), total suspended solids (TSS), total nitrogen and total phosphorus, regulated in the water permit were used to evaluate the efficiency of contaminants removal. On the basis of the percentage reduction of the individual pollutants indicators and their acceptable concentrations in the treated sewage, the effectiveness of the operation of the object was determined. Furthermore, a so-called the treatment plant reliability factor (RF) was calculated and its value below 1.0 indicates the correct operation of the wastewater treatment plant. After determining the prospective amount of raw sewage in 2036 (based on the decreasing population in the city) it has been found that the WWTP will work with a significant reserve of capacity and the modernization of the treatment system, leading to a decrease of its capacity should be considered.
Źródło:
Journal of Ecological Engineering; 2018, 19, 2; 114-124
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prediction of adsorption efficiencies of Ni (II) in aqueous solutions with perlite via artificial neural networks
Autorzy:
Turp, S. M.
Powiązania:
https://bibliotekanauki.pl/articles/204724.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wastewater
treatment efficiency
adsorption
perlite
artificial neural network
Opis:
This study investigates the estimated adsorption efficiency of artificial Nickel (II) ions with perlite in an aqueous solution using artificial neural networks, based on 140 experimental data sets. Prediction using artificial neural networks is performed by enhancing the adsorption efficiency with the use of Nickel (II) ions, with the initial concentrations ranging from 0.1 mg/L to 10 mg/L, the adsorbent dosage ranging from 0.1 mg to 2 mg, and the varying time of effect ranging from 5 to 30 mins. This study presents an artificial neural network that predicts the adsorption efficiency of Nickel (II) ions with perlite. The best algorithm is determined as a quasi-Newton back-propagation algorithm. The performance of the artificial neural network is determined by coefficient determination (R2), and its architecture is 3-12-1. The prediction shows that there is an outstanding relationship between the experimental data and the predicted values.
Źródło:
Archives of Environmental Protection; 2017, 43, 4; 26-32
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ ścieków przemysłowych na energochłonność i efektywność procesów technologicznych w komunalnej oczyszczalni ścieków
The Influence of Industrial Wastewater on the Energy Consumption and the Efficiency of Technological Processes in Municipal Wastewater Treatment Plant
Autorzy:
Remiszewska-Skwarek, A.
Fudala-Książek, S.
Łuczkiewicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/1818027.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
oczyszczanie ścieków komunalnych
efektywność oczyszczania
ścieki przemysłowe
treatment of municipal wastewater
efficiency of treatment
industrial wastewater
Opis:
In recent years, the municipal WWTP operated by PEWIK Gdynia receives increasing quantity of industrial wastewater with COD/BOD ratio above 2. In most cases, it is probably due to the required reduction of certain pollutants before delivery of industrial wastewater to the sewage system. Implemented pre-treatment of industrial wastewater by on-site plants usually remove the nutrients and easily biodegradable organic matter, while other organic fractions are directed to the municipal WWTP. In this study the influence of industrial wastewater on the efficiency of technological processes was analyzed on the basis of WWTP in Gdynia-Debogorze. For this reason, the COD fractions (readily (soluble) and slowly (particulate) biodegradable fraction, and non-biodegradable soluble (inert) and particulate fraction) were analyzed in raw wastewater. Obtained results were discussed in terms of the efficiency of treatment processes as well as the energy consumption and the operating costs of the plant.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 2; 110-121
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effectiveness of Floating Treatment Wetlands with Cyperus papyrus Used in Sub-Humid Climate to Treat Urban Wastewater: A Case Study
Autorzy:
Benrahmane, Loubna
Mouhir, Latifa
Kabbour, Amal
Laaouan, Mohamed
El Hafidi, Mustapha
Powiązania:
https://bibliotekanauki.pl/articles/2173285.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
phytoremediation
wastewater
floating treatment wetlands
Cyperus Papyrus
removal efficiency
Opis:
The wastewater from small communities and rural areas, usually discharged in an unsuitable manner, requires an appropriate treatment. The floating treatment wetland has revealed a great potential due to good performance, low cost and low maintenance means of improving water quality over a broad range of applications. The aim of this article was to present the results of the adaptation period (57 days) of a macrophyte plant “Cyperus papyrus” and its potential for treating wastewater generated by the campus of the National Office of Electricity and Drinking Water (ONEE) of Rabat. Two hydraulic retention times were applied: 2 and 4 days. Pilot experimental setups (two tanks) were installed: one tank where the macrophyte, being the subject of the study, was installed and the other served as a control. The macrophyte plants were suspended in floating mat, keeping the plant roots permanently in contact with the water and removing pollutants via several processes. During the adaptation of the plant which concerned four parameters: the evolution of the density, the height of the stems, the number of shoots as well as the state of health of the plants, a period of adaptation to the medium of implantation of fifty-seven days was observed. Along this adaptation phase, the results showed that: plant density increased from 9 to 29 units; the heights of the four identified stems of Cyperus papyrus increased from 15, 6, 11 and 8 cm to 73, 43, 30 and 24 cm, respectively; the appearance of 72 shoots and the plant has completed the adaptation phase in good health (absence of disease Symptoms). The treated water obtained from outlet and wastewaters were analyzed for various water quality parameters, such as Chemical Oxygen Demand (COD), Biological Oxygen Demand (BOD), and Suspended Solids (SS). The floating treatment wetlands system is able to remove 37.8% of COD; 47.6% of BOD5and 74.4% of SS for HRT of 2 days and 63.7% of COD; 78.4% of BOD5 and 89.1% of SS for HRT of 4 days. Moreover, it was found that the purification efficiency in terms of these three pollution parameters is all the more important as the hydraulic retention time is high.
Źródło:
Journal of Ecological Engineering; 2022, 23, 7; 157--168
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wybranych parametrów pracy oczyszczalni w technologii „Lemna” na przykładzie gminnej oczyszczalni ścieków w Chmielniku (woj. Podkarpackie)
Analysis of selected operational parameters of „Lemna” treatment plant, on the example of the MWWTP in Chmielnik (Poland, Subcarpathian Province)
Autorzy:
Jurczyk, Ł
Koc-Jurczyk, J.
Winiarska, K.
Powiązania:
https://bibliotekanauki.pl/articles/400273.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ścieki komunalne
Lemna
oczyszczanie ścieków
efektywność oczyszczania
wskaźnik niezawodności
municipal wastewater
wastewater treatment
treatment efficiency
reliability index
Opis:
W pracy przedstawiono analizę pracy gminnej oczyszczalni ścieków typu „Lemna”, a badaniami objęto okres siedmiu lat (2009–2015). Badano sprawność usuwania takich wskaźników jak BZT5, ChZT oraz zawiesiny ogólnej. Pomimo bardzo wysokiej zmienności stężeń w ściekach dopływających, we wszystkich przypadkach stwierdzono wysoką skuteczność i niezawodność działania instalacji. Średnia efektywność usuwania zanieczyszczeń organicznych i zawiesiny ogólnej wyniosła 94,23% BZT5, 82,55% ChZT oraz 76% zawiesiny ogólnej i była dodatnio skorelowana z obciążeniem tymi parametrami ścieków surowych.
In this paper the analysis of „Lemna” municipal treatment plant performance is reported, the study covered a period of seven years (2009–2015). The efficiency of removal of such indicators as BOD5, COD and total suspended solids were examined. Despite the very high variability of concentrations in raw wastewater, high efficiency and reliability of the installation was found in all cases. The average removal efficiency of organic compounds and total solids was 94.23% for BOD5, 82.55% for COD and 76% for total suspended solids; moreover, it was positively correlated with the load on these parameters in inflow.
Źródło:
Inżynieria Ekologiczna; 2017, 18, 5; 10-17
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ways of improving efficiency of wastewater treatment for agriculture
Sposoby usprawnienia wydajności oczyszczania ścieków w rolnictwie
Autorzy:
Myrzahmetov, M. M.
Ryskulbekova, L. M.
Powiązania:
https://bibliotekanauki.pl/articles/908439.pdf
Data publikacji:
2013
Wydawca:
Fundacja Ekonomistów Środowiska i Zasobów Naturalnych
Tematy:
obrotowe obiegi wodne
zamknięte obiegi wodne
wydajność oczyszczalni ścieków
woda w rolnictwie
water cycle
efficiency of wastewater treatment plants
water in agriculture
Opis:
Obrotowe i zamknięte obiegi wodne to najbardziej obiecujące sposoby na ograniczenie zużycia słodkiej wody. Prawdopodobnie w przyszłości oczyszczone ścieki staną się głównym źródłem wody w rolnictwie. Słodka woda będzie dostępna dla zapotrzebowania domowego.
Modern human civilization is characterized by one of the actual problem, the protection of natural environment from pollution and depletion of water resources.
Źródło:
Ekonomia i Środowisko; 2013, 4; 266-275
0867-8898
Pojawia się w:
Ekonomia i Środowisko
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the stability and reliability of the water treatment plant in Nowy Sącz using control cards
Autorzy:
Śliz, Paulina
Bugajski, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2073749.pdf
Data publikacji:
2022
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
control cards
pollution reduction efficiency
stability of wastewater treatment
technological reliability
water treatment plant
Opis:
The subject of the study was to evaluate the stability and reliability of the sewage treatment plant in Nowy Sącz. The scope of the analysed indicators included the main indicators of wastewater contamination: BOD5(biochemical oxygen demand), CODCr (chemical oxygen demand), total suspended solids (TSS), total nitrogen (Ntot), and total phosphorus (Ptot). The operation stability of the sewage treatment plant in Nowy Sącz was determined on the basis of control cards x for 24 observations made in the period 2018-2019 (2 years). Moreover, the technological reliability of the tested sewage treatment plant (WN) was determined based on the values of the analysed pollution indicators in treated sewage and their permissible values. On the basis of the conducted analyses, full stability of the removal process of most of the analysed contaminants was found. In no case was there any crossing of the control lines, only a single grouping of samples above the help line in the case of total nitrogen, which could indicate a periodical disturbance in the stability of the removal process of this compound. On the basis of the obtained values of the reliability coefficient, which were below WN=1.00, reliable operation of the analysed facility was found, with a high degree of reduction (ƞ) of the analysed pollutants. The method of determining the technological reliability and stability of the treatment plant with the use of control cards is an effective and easy tool for detecting any disturbances and instabilities in the processes taking place in the tested facility. It enables the operator to take quick action to remove them, thus ensuring a safe wastewater treatment process for the environment and human health.
Źródło:
Journal of Water and Land Development; 2022, 52; 251--256
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies