Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "sensitivity for radon" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Configuration of the parameters for scanner-based track detector evaluation system
Autorzy:
Csordás, Anita
Tóth-Bodrogi, Edit
Kovács, Tibor
Powiązania:
https://bibliotekanauki.pl/articles/147714.pdf
Data publikacji:
2020
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
background track density
CR-39
etching conditions
indoor radon
sensitivity for radon
Opis:
According to the new European Union Basic Safety Standards (EU-BSS), preparation of the National Radon Action Plan is obligatory for the Member States. One of the plan’s aims is to carry out an indoor radon survey to identify radon-prone areas. In the radon surveys, track detector methods are used. At the University of Pannonia (Veszprém, Hungary), a new scanner-based detector evaluation system has been developed. For the application of the new system, the selection of appropriate parameters is necessary. In this study, selection of the applied track detectors and setting of the etching conditions have been carried out. Two different types of allyl diglycol carbonate (ADC or CR-39) track detectors were investigated, taking into account the detector’s background and response during the exposure (determination of calibration factor). The Baryotrak’s background track density (0–1.5 tracksmm–2) was lower than that of the 0.8–4 tracksmm–2. The response of the Tastrak was higher, but the deviation of the calibration factor was much higher (1.2–5.3 × 10–3 tracksmm–2/(Bqdaym–3)) than in the case of the Baryotrak (1.4–2.8 × 10–3 tracksmm–2/(Bqdaym–3)). After the systematic review of the etching system, a new method was developed. For the determination of the optimal track diameter, the argon fluoride (ArF) laser was applied to create tracks with diameters in the range of 10–100 µ. The optimum track size was in the range of 40–60 µ. On this basis, new etching conditions were determined: 6.25 M NaOH solution, a temperature of 90 degree centigrade, and time period of 8 hours.
Źródło:
Nukleonika; 2020, 65, 2; 133-137
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sequential optimization for semilinear divergent hyperbolic equation with a boundary control and state inequality constraint
Autorzy:
Gavrilov, V. S.
Sumin, M. I.
Powiązania:
https://bibliotekanauki.pl/articles/206311.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Instytut Badań Systemowych PAN
Tematy:
Radon measures
sequential optimization
maximum principle for minimizing sequences
semilinear hyperbolic partial differential equations
pointwise in time state constraints
boundary control
value function
sensitivity
normality
regularity
twoparameter needle variation of controls
Opis:
An optimal control problem with a state constraint of inequality type and with dynamics described by a semilinear hyperbolic equation in divergence form with the non-homogeneous boundary condition of the third kind is considered. The state constraint contains a functional parameter that belongs to the class of continuous functions and occurs as an additive term. We study the properties of solutions of linear hyperbolic equations in divergence form with measures in the original data and compute the first variations of functionals on the basis of a so-called two-parameter needle variation of controls. We consider the necessary conditions for minimizing sequences in an optimal control problem with a pointwise in time state constraint of inequality type and with dynamics described by a semilinear hyperbolic equation in divergence form with the non-homogeneous boundary condition of the third kind. For the parametric optimization problem, we also consider regularity and normality conditions stipulated by the differential properties of its value function.
Źródło:
Control and Cybernetics; 2014, 43, 2; 183-226
0324-8569
Pojawia się w:
Control and Cybernetics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies