Tytuł:
Is mechanical retention for adhesive core build-up needed to restore a vital tooth with a monolithic zirconium crown? : An in vitro study
Autorzy:
Walczak, K
Rues, S.
Więckiewicz, M.
Range, U.
Schmitter, M.
Powiązania:
https://bibliotekanauki.pl/articles/306595.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
core build-up
luting agent
MDP
retentive cavity
zirconia
fracture resistance
dwutlenek cyrkonu
odporność na pękanie
Opis:
Purpose: To show the influence of retentive cavity, cavity wall preparation and different luting techniques on the fracture resistance of severely damaged teeth restored with adhesive core build-ups and monolithic zirconium crowns. Methods: Extracted molars were prepared with 2 mm ferrule height and divided into eleven groups (n = 8/group). In nine groups a retentive occlusal cavity with a width and depth of 1 or 2 mm was prepared. Two control groups without a retentive cavity were made. Zirconium crowns were manufactured. 48 copings were cemented with glass-ionomer cement (Ketac Cem), the others (n = 40) with adhesive resin cement (Panavia F 2.0). Artificial ageing was carried out in the following way: n = 88, thermocycling (10,000 cycles, 6° C/60° C), n = 80 chewing simulation (1,200,000 cycles, 64 N). The samples were tested for load at first damage and fracture load with non-axial force. For statistical analysis ANCOVA with post hoc, Bonferroni-adjusted t-test were used ( p ≤ 0.05). Results: No differences between the tested cements were detected. Influence of the cavity wall thickness was significant ( p = 0.001). Mostly, the samples with wall thickness of 2 mm showed better results. Both control groups (no cavity) showed results comparable to study groups with cavity. Conclusions: Retentive cavity is most likely not mandatory. However, if prepared, the cavity wall thickness is of higher importance than cavity depth. Glass-ionomer and adhesive resin cement are comparable for use with zirconia crowns.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 4; 117-125
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies