Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "electrochemical detection" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Electrochemical biosensors for detection of avian influenza virus - current status and future trends
Autorzy:
Grabowska, Iwona
Malecka, Kamila
Jarocka, Urszula
Radecki, Jerzy
Radecka, Hanna
Powiązania:
https://bibliotekanauki.pl/articles/1039249.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
electrochemical biosensors
genosensors
immunosensors
electrochemical detection
avian influenza virus
Opis:
Electrochemical biosensors have emerged as reliable analytical devices suitable for pathogen detection. Low cost, small sample requirement and possibility of miniaturization justifies their increasing development. Thus, we report in this review on the state of the art of avian influenza virus detection with genosensors and immunosensors working by an electrochemical mode. Their working principles focusing on the physical properties of the transducer, the immobilization chemistry, as well as new trends including incorporation of nanoparticles will be presented. Then, we critically review the detection of avian influenza virus in the complex matrices that use electrochemical biosensors and compare them with traditionally applied methods such as ELISA or Western blot.
Źródło:
Acta Biochimica Polonica; 2014, 61, 3; 471-478
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Effect of an Accidental Carrier Rocket Crash on Soil and Vegetation Cover
Autorzy:
Maikanov, Balgabay S.
Auteleyeva, Laura T.
Zhubatov, Zhailaubay K.
Terlikbayev, Askar A.
Kamsaev, Kanat M.
Powiązania:
https://bibliotekanauki.pl/articles/2027816.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
UDMH
unsymmetrical dimethylhydrazine
NDMA
N-nitrosodimethylamine
carrier rocket
Proton-M
Baikonur
liquid chromatography
electrochemical detection
spectrophotometric detection
carrier rocket Proton-M
Opis:
The dynamics of the consequences of the Proton-M carrier rocket crash on the soil and vegetation cover in the area where its parts fell were studied in 2007-2014. Analytical methods such as liquid chromatography with electrochemical and spectrophotometric detection were used. In 2007, four soil detoxifications were performed. A second study in 2009 showed a sharp increase in the area of contamination of plants by UDMH (unsymmetrical dimethylhydrazine) and NDMA (N-Nitrosodimethylamine). In 2010, the situation shifted in the opposite direction. Toxicants in plants were absent for three years (2010-2012) but reappeared in 2013 and 2014. The accidental crash of the Proton-M carrier rocket led to the destruction of the soil and vegetation cover, ignition of vegetation, and soil contamination. In the area where the rocket parts fell, the UDMH content in the soil was 1.4–5,200 times higher than the threshold limit value. The fall of the carrier rocket increased the area of soil contamination with UDMH to $3,600 m^2$, with NDMA to $917 m^2$, and with nitrate ions to $8,314 m^2$. The reappearance of heptyl and nitrous compounds in plants and soil was detected four years after repeated detoxification of the soil.
Źródło:
Journal of Ecological Engineering; 2022, 23, 2; 176-184
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie i analiza czynników determinujących proces tworzenia powłoki bioreceptorowej na powierzchni kontaktów Au w konstrukcji biosensorów wykrywających obecność patogenów w akwakulturze
Study and analysis of factors determining a process of bioreceptor layer formation on a surface of AU contacts in biosensors detecting pathogens in aquaculture
Autorzy:
Prządka, Marcin Paweł
Wojcieszak, Damian
Pala, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/27323994.pdf
Data publikacji:
2023
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
kontakty Au
elektrochemiczna spektroskopia impedancyjna
biosensor
detekcja patogenów
gold substrate
electrochemical impedance spectroscopy
biosensors
pathogen detection
Opis:
Czujniki zyskują coraz więcej zastosowań, szczególnie w obszarach takich jak opieka zdrowotna, diagnostyka medyczna i weterynaryjna oraz kontrola jakości żywności, której bezpieczeństwo staje się coraz większym problemem na całym świecie. w ramach pracy zbadano czynniki determinujące proces tworzenia powłoki bioreceptorowej na polach kontaktowych biosensorów w postaci warstw au oraz ich odpowiedź impedancyjną do zastosowania w detekcji patogenów w akwakulturze. w wyniku badań z użyciem podłoży biosensorowych o różnej chropowatości zauważono zależność między stopniem rozwinięcia powierzchni elektrod au a formowaniem się prawidłowej warstwy bioreceptorowej. Zmiany te zaobserwowano na podstawie analizy kąta zwilżania dla wybranych podłoży. Przeprowadzone pomiary z użyciem elektrochemicznej spektroskopii impedancyjnej wykazały, że złote elektrody z mniejszą chropowatością podłoża pozwalają uzyskać lepszą odpowiedź impedancyjną.
Sensors are becoming increasingly important every day, especially in applications such as healthcare, medical and veterinary diagnostics, and food quality control, the safety of which is becoming a more important issue worldwide. The present study investigated the critical aspects of the formation of the bioreceptor layer on biosensors and their impedance response for use in pathogen detection in aquaculture. as a result of the studies, conducted with gold substrates of different roughness, a correlation was observed between the degree of development of the au electrode surfaces and formation of the correct bioreceptor layer. These changes were observed on the basis of a wetting angle analysis for selected substrates. Measurements using electrochemical impedance spectroscopy showed that gold electrodes with lower substrate roughness obtained a better impedance response (nyquist plot). On the basis of a comprehensive analysis of the results, an innovative criterion was developed to evaluate the quality of biosensors at an early stage of their production.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2023, 72, 1; 47--57
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Integrated microsystem for multiplexed genosensor detection of biowarfare agents
Autorzy:
Ema, Sagbor Grinity
Mwadwo, Kwumasi Sylvester
Paul, Bosu P.
Powiązania:
https://bibliotekanauki.pl/articles/1119284.pdf
Data publikacji:
2016
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Bacillus anthracis
Bacteriophage lambda
Brucella melitensis
Burkholderia mallei
Coxiella burnetii
Electrochemical DNA biosensor. Biowarfare agent
Francisella tularensis
Multiplex detection
Self-assembled monolayer (SAM)
Yersinia pestis
Opis:
An early, rapid and definite detection for the presence of biowarfare agents, pathogens, viruses and toxins is required due to their harmful effect to human population. Those potentially encountering the aforementioned include people involved in civil rescue and security, homeland security, military operations, as well as public transportation securities such as airports, metro and railway stations. This work informs the reader of an electrochemical genosensor with an integrated microsystem array combined with microtube fluidics that allows simultaneous detection of different biowarfare agents such as Bacillus anthracis, Brucella melitensis, Bacteriophage lambda, Francisella tularensis, Burkholderia mallei, Coxiella burnetii, Yersinia pestis, and Bacillus thuringiensis var. kurstaki. The chip electrode arrays were modified via coimmobilisation of a 1:100 (mol/mol) mixture of a thiolated probe and a polyethyleneglycol terminated bipodal thiol. Herein, PCR products from relevant biowarfare agents were detected reproducibly through a sandwich assay format with the target hybridised between a surface immobilised probe into the electrode and a horseradish peroxidase-labelled secondary reporter probe, which provided an enzyme based electrochemical signal. Cross-reactivity studies over potential interfering DNA sequences have demonstrated high selectivity using the developed platform producing high-throughput.
Źródło:
World News of Natural Sciences; 2016, 5; 20-32
2543-5426
Pojawia się w:
World News of Natural Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elektrody jonoselektywne – klasyka i nowe koncepcje
Ion-selective electrodes – classical systems and new ideas
Autorzy:
Maksymiuk, K.
Michalska, A.
Powiązania:
https://bibliotekanauki.pl/articles/143070.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Przemysłu Chemicznego. Zakład Wydawniczy CHEMPRESS-SITPChem
Tematy:
elektrody jonoselektywne
potencjometria
uproszczenia konstrukcyjne
obniżenie granicy wykrywalności
nanocząstki
metody prądowe
ion-selective electrodes
potentiometry
construction simplification
detection limit lowering
nanoparticles
electrochemical current based techniques
Opis:
Artykuł dotyczy tendencji rozwojowych elektrod jonoselektywnych stosowanych w potencjometrii. Przedstawiono typowe rozwiązania stosowane w praktyce, a także opisano główne kierunki badań dotyczących tej grupy sensorów, związanych zarówno z uproszczeniami konstrukcji, jak i poprawą parametrów analitycznych. Scharakteryzowano też nowe możliwości analityczne uzyskiwane dla takich elektrod w warunkach polaryzacji prądowej.
The article concerns trends in development of ion-selective electrodes used in potentiomeric analysis, it shows typical practical solutions and describes main trends of research concerning this group of sensors, oriented both to construction simplification and improvement of analytical parameters. New analytical advantages, achieved under conditions of galvanostatic polarization, were also described.
Źródło:
Chemik; 2015, 69, 7; 373-382
0009-2886
Pojawia się w:
Chemik
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies