Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "analiza jakości wody" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Effect of water scarcity on households’ livelihoods in Iwoye-Ketu Area of Ogun State, Nigeria
Wpływ deficytu wody na poziom życia w gospodarstwach domowych na obszarze Iwoye-Ketu w nigeryjskim stanie Ogun
Autorzy:
Aromolaran, Adetayo K.
Ademiluyi, Ibiyinka O.
Sotola, Abiodun E.
Wole-Alo, Felicia I.
Aromiwura, Oluwadamilola A.
Ogunsuyi, Olubukola E.
Powiązania:
https://bibliotekanauki.pl/articles/292360.pdf
Data publikacji:
2019
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
Iwoye-Ketu
livelihoods
perceived effects
water quality analysis
water scarcity
water sources
analiza jakości wody
deficyt wody
odczuwane skutki
poziom życia
źródła wody
Opis:
Water is an essential commodity which affects life and livelihoods in the universe. This study examined perceived effect of water scarcity on livelihoods in Iwoye-Ketu, Ogun State. Random sampling was used to select 80 rural households and water samples for the study. Data collected were analysed using descriptive, inferential and laboratory analyses. Findings showed that the mean age of respondents was 38 years with an average household size of four persons. The major sources of water were boreholes (97.5%) and rainwater (90.0%), the average trekking time to the water source was 24 minutes and the households requires an average of 162 litres of water per day. Water analysis’ result showed that the water has pH (6.87), total dissolved solids (0.175 mg∙dm–3), temperature (29.9°C) and turbidity (0.6 FTU). The major causes of water scarcity include insufficient rainfall (97.5%), increased sunlight intensity (97.5%), pollution of water sources (95.0%) and increased population (93.8%). About 60% of them perceived water scarcity to have a negative effect on their livelihoods. Correlation analysis shows that there is a significant relationship between usage of water (r = 0.370, p < 0.01) and perceived effect of water scarcity. It was concluded that water available for household use is not sufficient, although it is safe but contain some elements which are not of World Health Organization standard for good potable water. It is recommended that the community should build a hub for water collection and distribution close to the village centre and the government should provide water infrastructures to increase the supply of potable water.
Woda jest podstawowym dobrem, które wpływa na życie i warunki życia na świecie. W przedstawionej pracy badano wpływ deficytu wody na poziom życia w Iwoye-Ketu w stanie Ogun. Do badań losowo wybrano 80 wiejskich gospodarstw i próby wody. Zebrane dane analizowano za pomocą metod opisowych, wnioskowania i metod laboratoryjnych. Średni wiek respondentów wynosił 38 lat, a średnia wielkość gospodarstwa – 4 osoby. Głównym źródłem wody były studnie wiercone (97,5%) i opady deszczu (90,0%). Średni czas dojścia do źródła wody wynosił 24 minuty, a gospodarstwa zużywały średnio 162 dm3 wody na dzień. Woda miała pH 6,87, sumę substancji rozpuszczonych 0,175 g∙dm–3, temperaturę 29,9°C i mętność 0,6 FTU. Do głównych przyczyn niedostatku wody zaliczano niewystarczające opady (97,5%), silne nasłonecznienie (97,5%), zanieczyszczenie źródeł wody (95,0%) i przeludnienie (93,8%). Około 60% respondentów uważało, że niedostatek wody wywiera ujemny wpływ na ich poziom życia. Analiza korelacji wykazała, że istnieje istotna zależność (r = 0,370, p < 0,01) między zużyciem wody a odczuciem negatywnego wpływu jej braku. Stwierdzono, że woda jest dostępna gospodarstwom w niedostatecznej ilości i choć bezpieczna, to zawiera pewne składniki, które nie spełniają norm Światowej Organizacji Zdrowia ustalonych dla wody pitnej. Zaleca się, aby lokalna społeczność zbudowała miejsce gromadzenia i dystrybucji wody blisko centrum wsi, a rząd powinien zapewnić infrastrukturę w celu poprawy zaopatrzenia w wodę pitną.
Źródło:
Journal of Water and Land Development; 2019, 43; 9-18
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie analiz wielowymiarowych do oceny jakości wody pitnej
Applying multidimensional analyses to assess drinking water quality
Autorzy:
Rymuza, K.
Radzka, E.
Powiązania:
https://bibliotekanauki.pl/articles/826316.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Technologów Żywności
Tematy:
woda pitna
jakosc
ocena jakosci
wskazniki jakosci
analiza wielowymiarowa
analiza skupien
analiza wody
Opis:
W pracy przedstawiono możliwość zastosowania metod wielowymiarowych do analizy jakości wody pitnej. Na podstawie wyników trzyletnich badań (2009 - 2011) przeanalizowano parametry fizykochemiczne wody pitnej z 15 wodociągów powiatu łosickiego. Wszystkie wodociągi ujmowały wodę podziemną dobrej jakości, gdyż w badanym okresie zaobserwowano tylko 7 przekroczeń zawartości żelaza, 2 przekroczenia poziomu barwy i 1 przekroczenie utlenialności. Analiza PCA wykazała, że jakość wody najsilniej różnicowały wskaźniki związane z pierwszymi czterema składowymi. Analiza skupień pozwoliła zaś na wyodrębnienie 4 grup wodociągów różniących się jakością dostarczanej wody. Grupę I stanowiły wodociągi, w których woda była twarda, ale jednocześnie zawierała mało żelaza i manganu. Wodociągi z grupy II dostarczały wodę o małej zawartości związków azotowych. Woda z wodociągów grupy III zawierała relatywnie dużo żelaza i manganu, ale jednocześnie była najmniej twarda i charakteryzowała się najniższym wskaźnikiem przewodności elektrycznej. Grupę IV tworzyły wodociągi, które doprowadzały wodę o relatywnie dużej mętności i dużej zawartości żelaza, ale o bardzo niskim pH.
In the paper, there were presented the possibilities of applying multidimensional methods to analyse the quality of drinking water. Based on the three year research results (2009 - 2011), analyzed were the physical and chemical parameters of drinking water from 15 water supply systems in the district (in Polish: powiat) of Łosice. Groundwater supplied by all the systems was of good quality as, during the period studied, only 7 cases were reported where the content of iron was exceeded, 2 cases where the colour level was exceeded, and 1 case with the exceeded level of KMnO4 oxidation. The principal component analysis (PCA) showed that the parameters associated with the first four components impacted the quality of water analyzed most of all. The cluster analysis made it possible to distinguish 4 groups of water supply systems, which differed as regards the quality of water supplied. Group I comprised the systems with hard water and, at the same time, with low contents of iron and manganese. The water systems in group II supplied water with a low content of nitrates. The water in the systems of group III contained relatively high amounts of iron and manganese, but, at the same time, its hardness was the lowest and it was characterized by the lowest value of the electrical conductivity index. Group IV comprised the water supply systems that provided water with a relatively high turbidity level and a high content of iron; however, its pH value was very low.
Źródło:
Żywność Nauka Technologia Jakość; 2013, 20, 6
1425-6959
Pojawia się w:
Żywność Nauka Technologia Jakość
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena jakości wody pitnej w powiecie siedleckim
Valuation of drinking water quality in Siedlce district
Autorzy:
Radzka, E.
Koc, G.
Rak, J.
Powiązania:
https://bibliotekanauki.pl/articles/886354.pdf
Data publikacji:
2008
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
analiza wody
jakosc
normy polskie
ocena jakosci
powiat siedlecki
woda pitna
wymagania jakosciowe
Opis:
Valuation of water quality needs estimating the value of all the physical, chemical and biological indicators. In the study it was shown the valuation of drinking water quality in Siedlce district which was made based on data coming from the period 2004–2006. The results of water examine come from the District Sanitary Epidemiological Station in Siedlce. The examined water was taken from 31 water-supplies in Siedlce district. In 2004 water coming from 14 water-supplies met its Polish standards. Whereas the number, frequency and amount of excess of acceptable standards rose in 2005 and 2006. In analysed period among physical parameters hue and turbidity were exceeded predominatingly whereas among chemical ones – manganese and iron. Biological indicators exceeding the acceptable standard most often are: total number of bacteria in 37°C (23 times) and number of bacteria coli group (17 times). Nitrites, taste, smell, conductivity and reaction are the parameters which did not exceed valid standards in any examined water-supply. The water- -supplies with best water quality in which the indicators did not exceed the standards are Stok Lacki and Stasin.
Źródło:
Scientific Review Engineering and Environmental Sciences; 2008, 17, 3[41]
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porownawcze bakteriologiczne badanie wody w kapieliskach woj.szczecinskiego wykonane wg metodyki stosowanej w polnocnych landach Republiki Federalnej Niemiec i metodyki Panstwowego Zakladu Higieny
The comparative bacteriological examinations of the bathingwaters in Szczecin province, performed by methods using in nothern lands of Germany and Panstwowy Zaklad Higieny
Autorzy:
Torun, D
Dziurzynska, F.
Powiązania:
https://bibliotekanauki.pl/articles/871233.pdf
Data publikacji:
1993
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
kontrola sanitarna
stacje sanitarno-epidemiologiczne
woj.szczecinskie
wody powierzchniowe
analiza wody
analiza mikrobiologiczna
kapieliska
kontrola jakosci
zanieczyszczenia srodowiska
zanieczyszczenia wod
sanitary control
sanitary-epidemiological station
Szczecin voivodship
surface water
water analysis
microbiological analysis
bathing site
quality control
environment contaminant
water contaminant
Opis:
Wykonano równoległe badania bakteriologiczne próbek wody w kąpieliskach zgodnie z metodyką Państwowego Zakładu Higieny, stosowaną przez stacje sanitarno-epidemiologiczne w Polsce i metodykę opracowaną przez zespół specjalistów niemieckich w nadmorskich Landach Republiki Federalnej Niemiec. Porównano wytyczne kontroli sanitarnej jakości wody w kąpieliskach, obowiązujące w Polsce z wytycznymi EWG.
For the purpose of this work was the comparison of the obligatory diretive lines using by sanitary - epidemic station in Poland and confrontation with EWG Guideline and comparison of the bacteriological examinations methods of surface waters using in Poland and northern Lands of Germany. The parallel examination of 120 water samples, according to PZH method and the method, using broth's Brila - MUG, preparated by the group of german specialists, were performed. The equivalent results in 60% of tested sampels were obtained. If confirmed on purpose the preparating of uniform directive lines and evaluation criterium for maritime and inland bathing waters, according to EWG Guidline, and as well as taking into consideration possibility of application the method with Brila MUG broth to bacteriological examination of maritime bathing waters at first.
Źródło:
Roczniki Państwowego Zakładu Higieny; 1993, 44, 2-3; 221-225
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies