Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Power Flow Control" wg kryterium: Temat


Tytuł:
Experimental Investigations of the Upqc Arrangement
Autorzy:
Benysek, G.
Powiązania:
https://bibliotekanauki.pl/articles/262602.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
power quality
power flow control
harmonics compensation
reactive power compensation
Opis:
This paper presents the fundamental properties and dependences describing the UPQC (Unified Power Quality Conditioner) arrangements. The UPQC devices simultaneously permit to fulfill the following functions: voltage and current harmonics compensation, network voltage and load current symmetrization as well as network voltage stabilization and power flow control. The selected results of the experimental investigations conducted on the small power laboratory model have been described. Applied method for DC link capacity selection was talked over in details and confirmed with experimental results. Results of experimental investigations, including operation of the UPQC arrangement in case of thyristor rectifier load were also introduced.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2006, 12, 1; 27-34
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Power flow analysis and control of distributed FACTS devices in power system
Autorzy:
Anand, V.
Mallik, S. K.
Powiązania:
https://bibliotekanauki.pl/articles/141190.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
D-FACTS
UPFC
power flow control
stability
THD
FACTS
Opis:
The deployment of a distributed power-flow controller (DPFC) in a single- machine infinite-bus power system with two parallel transmission lines are considered for the analysis in this paper. This paper presents the network analysis of the DPFC for power flow control. The performance is evaluated on a given test system with a single line-to- ground fault. The improvement in the stability as well as power quality is evident from the results. Thus the DPFC has the ability to enhance the stability and power quality of the system.
Źródło:
Archives of Electrical Engineering; 2018, 67, 3; 545--561
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimal location of interline power flow controller in a power system network using ABC algorithm
Autorzy:
Sreejith, S.
Psimon, S.
Selvan, M.P.
Powiązania:
https://bibliotekanauki.pl/articles/141232.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
IPFC
power injection model
power flow control
ABC algorithm
cost minimization
Opis:
This paper proposes a methodology based on installation cost for locating the optimal position of interline power flow controller (IPFC) in a power system network. Here both conventional and non conventional optimization tools such as LR and ABC are applied. This methodology is formulated mathematically based on installation cost of the FACTS device and active power generation cost. The capability of IPFC to control the real and reactive power simultaneously in multiple transmission lines is exploited here. Apart from locating the optimal position of IPFC, this algorithm is used to find the optimal dispatch of the generating units and the optimal value of IPFC parameters. IPFC is modeled using Power Injection (PI) model and incorporated into the problem formulation. This proposed method is compared with that of conventional LR method by validating on standard test systems like 5-bus, IEEE 30-bus and IEEE 118-bus systems. A detailed discussion on power flow and voltage profile improvement is carried out which reveals that incorporating IPFC into power system network in its optimal location significantly enhance the load margin as well as the reliability of the system.
Źródło:
Archives of Electrical Engineering; 2013, 62, 1; 91-110
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koncepcja zbocznikowania dławikiem przesuwnika fazowego na granicy polsko-niemieckiej
The concept of shifting with the induction coil of the phase shift transmitter at the polish-german border
Autorzy:
Szubert, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/2031418.pdf
Data publikacji:
2021
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
FACTS
PST
IPC
sterowanie przepływem mocy
zakłócenia
power flow control
disturbance
Opis:
W artykule przeanalizowano wpływ sterowników FACTS (PST oraz IPC) na pracę połączenia transgranicznego Polska-Niemcy. Stwierdzono, że przesuwnik fazowy PST spełnia podstawowe wymagania i tylko w niewielkim stopniu wpływa na automatykę zabezpieczeniową. Jego rozbudowa do układu międzyfazowego sterownika mocy IPC umożliwiłaby dodatkowo odcięcie się od zakłóceń pochodzących z niemieckiego systemu, jednakże wymagałaby istotnych zmian w automatyce zabezpieczeniowej.
Unplanned energy flow from Germany via Poland to the Czech Republic caused overheating of transmission lines in the west of our country. In order to prevent the necessity to switch off these lines, phase shift transformers (PST) were placed on the border. However, the German system is highly saturated with wind electricity and therefore difficult to steer, which makes it a source of interference for neighbouring countries. The article analyses the impact of flexible AC transmission system (FACTS) drivers on the operation of the Poland-Germany cross-border electrical connection. It was found that the PST meets the basic requirements and has only a slight influence on the protection automatics. Expanding it to the interphase power controller (IPC) would additionally cut off the interference from the German system, however, it would require profound changes in the protection automatics.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2021, 73; 57-60
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
New Multiphase Matrix Converter Based Device for Power Flow Control
Nowoczesne urządzenia do kontroli rozpływu mocy w systemie elektroenergetycznym oparte na wielofazowym przekształtniku macierzowym
Autorzy:
Szczepanik, J.
Sieńko, T.
Powiązania:
https://bibliotekanauki.pl/articles/397265.pdf
Data publikacji:
2013
Wydawca:
ENERGA
Tematy:
FACTS
matrix converter
power flow control
przekształtnik macierzowy
kontrola rozpływu mocy SEE
Opis:
The article presents the concept of new matrix converter (MC) based device working as a phase shifting control device in a power system. The multiphase MC is working under an innovative control algorithm specially dedicated to the proposed application. The work presents the results of the simulation of the MC work in this application as well as the analysis of the MC properties.
Autorzy artykuły prezentują koncepcję konstrukcji przesuwnika fazowego, zbudowanego z wykorzystaniem przekształtnika macierzowego (ang. matrix converter, MC) ze specjalnie opracowanym na potrzeby tego urządzenia algorytmem kontroli. Przedstawiają również wyniki prób symulacyjnych, pokazujących wpływ urządzenia na rozpływ mocy w prostym systemie elektroenergetycznym (SEE).
Źródło:
Acta Energetica; 2013, 4; 158-171
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie możliwości przesyłowych dwóch układów regulacyjnych: transformatorów z regulacją poprzeczną oraz transformatorów z regulacją wzdłużną
A comparison transmission capacity of two regulation transformers with quadrature regulation and in-phase regulation
Autorzy:
Sarnicki, M.
Zajczyk, R.
Tarakan, B.
Tarakan, K.
Powiązania:
https://bibliotekanauki.pl/articles/267801.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przesuwnik fazowy
regulacja przepływu mocy czynnej
regulacja przepływu mocy biernej
regulacja kąta mocy
transformator dodawczy
Phase Shifter
active power flow control
reactive power flow control
power angle
booster transformer connections
Opis:
Poniższy artykuł przedstawia możliwość regulacji mocy czynnej i biernej przepływającej pomiędzy podsystemami elektroenergetycznymi. Do regulacji przepływów wykorzystano przesuwnik fazowy i transformator dodający napięcie w fazie. Zilustrowana została regulacja mocy czynnej i biernej w badanym systemie elektroenergetycznym. Istotna jest zależność regulacji danej mocy od układu połączeń strony SN transformatora dodawczego (czy układ działa, jako przesuwnik czy jako transformator dodający napięcie w fazie).
This paper describes the regulation of active and reactive power between the subsystems in larger power system. To regulate the flow were used phase shifters and booster transformer which adds voltages in phase. The regulation of the active power and reactive in considered power system was shown in this article. Important is the way to regulate a certain kind of power (active or reactive), which strongly depends of MV side connections of booster transformer (whether the system acts as a phase shifter or as a transformer which adds the voltage in phase).
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 42; 89-91
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowoczesne urządzenia do kontroli rozpływu mocy w systemie elektroenergetycznym oparte na wielofazowym przekształtniku macierzowym
New multiphase matrix converer based device for power flow control
Autorzy:
Szczepanik, J.
Sieńko, T.
Powiązania:
https://bibliotekanauki.pl/articles/269062.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
FACTS
przekształtnik macierzowy
kontrola rozpływu mocy w SEE.
Matrix Converter
Power Flow Control
Opis:
Artykuł prezentuje koncepcję konstrukcji przesuwnika fazowego zbudowanego w oparciu o przekształtnik macierzowy (MC – matrix converter) ze specjalnie opracowanym na potrzeby tego urządzenia algorytmem kontroli. W artykule zawarto również wyniki prób symulacyjnych pokazujących wpływ urządzenia na rozpływ mocy w prostym Systemie Elektroenergetycznym - SEE.
The article presents the concept of new matrix converter (MC) based device working as a phase shifting control device in power system. The multiphase MC is working under innovative control algorithm specially dedicated for the proposed application. The work presents the results of the simulation of the MC work in this application as well as the analysis of the MC properties.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 32; 83-86
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automatic adjustment of phase shifting transformers – the ability to control the active power flow in international exchange lines
Automatyczne sterowanie przesuwnikami fazowymi – możliwości regulacji przepływu mocy czynnej w liniach wymiany międzynarodowej
Autorzy:
Opala, K.
Ogryczak, T.
Powiązania:
https://bibliotekanauki.pl/articles/397314.pdf
Data publikacji:
2017
Wydawca:
ENERGA
Tematy:
phase shifting transformers
control system
active power flow control
przesuwnik fazowy
system sterowania
regulacja przepływu mocy czynnej
Opis:
The authors presented the characteristics of Mikułowa substation in terms of its location and grid connections, brief functional description of its automatic controls, and the results of tests of the automatic control of four phase shifting transformers installed in Mikułowa – Hagenwerder international exchange lines. The tests were carried out as part of the phase shifting transformers’ commissioning at Mikułowa substation in 2016. These results allow one to verify the actual range of control of active power flow between the power system of Poland and Germany, and the control’s effect on the power flow in the NPS. This is the first such installation on a cross-border interconnection in Poland. So far the active power flow in the National Power System (NPS) has never been altered with the use of phase shifting transformers.
Autorzy przedstawili charakterystykę stacji elektroenergetycznej Mikułowa ze względu na jej lokalizację i powiązania sieciowe, skrócony opis funkcjonalny zastosowanej automatyki oraz wyniki badań działania układu automatycznej regulacji czterech przesuwników fazowych zainstalowanych w liniach wymiany międzynarodowej Mikułowa – Hagenwerder. Badania wykonano w ramach prac uruchomieniowych przesuwników fazowych prowadzonych w SE Mikułowa w 2016 roku. Wyniki te pozwalają zweryfikować rzeczywisty zakres regulacji przepływu mocy czynnej pomiędzy systemem elektroenergetycznym Polski i Niemiec oraz wpływ regulacji na rozpływ mocy czynnej w KSE. Jest to pierwsza tego typu instalacja na połączeniu transgranicznym w Polsce. Zmiana przepływu mocy czynnej z wykorzystaniem przesuwników fazowych nie była dotychczas stosowana w Krajowym Systemie Elektroenergetycznym (KSE).
Źródło:
Acta Energetica; 2017, 2; 149-157
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studium wykorzystania przekształtnika macierzowego do budowy przesuwnika fazowego
The study of the application of matrix converter into phase shifting device
Autorzy:
Sieńko, T.
Szczepanik, J.
Powiązania:
https://bibliotekanauki.pl/articles/266964.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przekształtnik macierzowy
przesuwnik fazowy
FACTS
kontrola rozpływu mocy
matrix converter
phase shifter
power flow control
Opis:
W pracy wykonano analizę zastosowania wielofazowego Przekształtnika Macierzowego (PM) do budowy Przesuwnika Fazowego (PS). Analizę przeprowadzono przy pomocy technik symulacyjnych oraz pomiarów wykonanych na sześciofazowym modelu przekształtnika zbudowanym w laboratorium. Zaprezentowano trzy podstawowe schematy kontroli oraz ich związek z własnościami PM. Poza zdolnością przesuwnika fazowego do zmiany transferu mocy czynnej, interesujący jest wpływ urządzenia na transmisję mocy biernej co pokazano w artykule. Nowo pokazane właściwości PM pozwalają na budowę PS o większych możliwościach kontroli Systemu ElektroEnergetycznego (SEE) niż obecnie dostępne urządzenia. Możliwości różnych wariantów sterowania PM, oraz duża prędkość reakcji bazującego na nim PS będą niewątpliwie przydatne w kontroli stanów dynamicznych pracy SEE (stanach po zaburzeniowych) np. do szybkiej likwidacji kołysań generatorów czy regulacji rozpływu mocy.
Nowadays, in modern power systems there is a tendency to build more and more dispersed energy sources, to increase their transmission abilities and to increase their size. Parallel to these actions, the requirements regarding the quality of the delivered energy and system reliability are also increased. These changes required the new solutions to system control in both static and dynamic states of work to be implemented. The paper includes the analysis of the application of the multiphase Matrix Converter (MC) to the development of the phase shifting device. The analysis was performed not only on the basis of the simulation, but also on the basis of the waveforms obtained from the real life model constructed in the laboratory. The relationships between the device control algorithms and the properties of the built on their basis phase shifting device were thoroughly investigated. Some of the described properties of the MC are not only connected to its ability to influence active power flow in the power line, but also to its impact on reactive power transmission. For three developed control procedures, the reactive power flow control was investigated for MC working as a voltage source inverter on inductive load. The capabilities of alternative control procedures and short device reaction times can be useful not only for power flow control, but also during system dynamic states for example to fast dumping of the system oscillations. The research is the continuation of the previously published work, and its next step will include the solution to the MC commutation problems and the implementation of the MC based shifting device to the already build model of the multi-node power system.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 42; 93-96
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of commutation conditions on steady states in matrix converter
Autorzy:
Borkowski, D.
Sobczyk, T. J.
Powiązania:
https://bibliotekanauki.pl/articles/141341.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
przekształtnik macierzowy
regulacja przepływu mocy
metoda bilansu harmonicznych
matrix converter
power flow control
harmonic balance method
Opis:
The paper investigates a significant influence of transients on steady states in a matrix converter with the one-periodic control strategy. Proposed controller can be used as an interconnection device within a power system for a power flow control. However, the presence of inductances in external systems has the significant influence on steady state of a matrix converter operation. The special current injection method has been developed to ensure a proper operation of a matrix converter. Presented analysis of steady states is carried out in a frequency domain using the harmonic balance method. Obtained numerical results, which are confirmed by a time domain analysis, prove the effectiveness of the proposed method.
Źródło:
Archives of Electrical Engineering; 2011, 60, 1; 77-83
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie możliwości regulacji przepływu mocy czynnej w liniach wymiany międzynarodowej
Exploring the possibility of controlling the active power flow in the cross-border tranmission lines
Autorzy:
Ogryczak, T.
Opala, K.
Powiązania:
https://bibliotekanauki.pl/articles/266635.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przesuwnik fazowy
regulacja przepływu mocy czynnej
Phase Shifting Transformer
active power flow control
cross-border transmission lines
Opis:
W referacie przedstawiono charakterystykę SE Mikułowa, skrócony opis funkcjonalny zastosowanej automatyki oraz wyniki badań działania układu automatycznej regulacji czterech przesuwników fazowych zainstalowanych w liniach wymiany międzynarodowej Mikułowa – Hagenwerder. Badania wykonano w ramach prac uruchomieniowych przesuwników fazowych prowadzonych w SE Mikułowa w 2016 roku. Wyniki te pozwalają zweryfikować rzeczywisty zakres regulacji przepływu mocy czynnej pomiędzy systemem elektroenergetycznym Polski i Niemiec oraz wpływ regulacji na rozpływ mocy czynnej w KSE. Jest to pierwsza tego typu instalacja na połączeniu transgranicznym w Polsce. Zmiana przepływu mocy czynnej z wykorzystaniem przesuwników fazowych nie była dotychczas stosowana w KSE.
The paper presents the characteristics of SE Mikułowa, a brief functional description of applied automation and research results of operation of automation for the four phase shifters installed in the cross-border transmission lines Mikułowa Hagenwerder. Research carried out in the framework of the phase shifters transformers startup conducted in SE Mikułowa in 2016. These results verify the actual range of controlling the active power flow between Polish and German power system and verify control influence on active power flow in Polish national power system. This is the first installation of such type on a cross-border connection in Poland. Changing the active power flow using the phase shifter transformers has not been used in the Polish national power system.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 53; 87-90
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Symulacja pracy przesuwnika fazowego w sieci elektroenergetycznej przy połączeniu transformatora szeregowego w gwiazdę
A computer simulation of the phase shifter effects in the power system with wye connection of the series transformer
Autorzy:
Sarnicki, M.
Tarakan, B.
Zajczyk, R.
Powiązania:
https://bibliotekanauki.pl/articles/268014.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przesuwnik fazowy
regulacja przepływu mocy czynnej i biernej
regulacja kąta mocy
Phase Shifter
active and reactive power flow control
power angle
Opis:
Poniższy artykuł prezentuje sposób regulacji mocy czynnej i biernej za pomocą przesuwnika fazowego, którego uzwojenie transformatora dodawczego (szeregowego) jest połączone w gwiazdę. W artykule pokazano regulację mocy czynnej i biernej na przykładzie wybranego systemu elektroenergetycznego. Omawiany przesuwnik fazowy reguluje jednocześnie przepływem mocy czynnej i biernej w danym systemie elektroenergetycznym.
The following article describes the adjustment of the active and reactive power using the phase shifter. The winding of the booster transformer (series) is wye connected. The article shows the regulation of the active and reactive power for selected power system that is 10 bus system with phase shifter. The phase shifter also regulates flow of the active and reactive power simultaneously in the power system. The most common situation is when the both power regulation are independent and it is a better way to have control of both of them. The simultaneous regulation of the active and reactive power is possible by adding transformed voltage from different phases.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 47; 167-169
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of phase shifting transformers on cross-border power flows in the Central and Eastern Europe region
Autorzy:
Korab, R.
Owczarek, R.
Powiązania:
https://bibliotekanauki.pl/articles/201812.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
phase shifting transformers
power flow control
cross-border power flows
unscheduled flows
tie-lines
transformator
sterowanie przepływem mocy
przesunięcie fazowe
energia przepływu
przepływ mocy
przepływy nieplanowe
Opis:
Unscheduled power flows are a serious problem for the Central and Eastern Europe (CEE) region. One method of reducing these undesirable flows relies on the use of phase shifting transformers (PSTs). This paper presents how the installation of PSTs on the Polish-German and Czech-German borders affects cross-border power flows in the CEE region, as well as interactions between these devices. The essential parameters proposed for PSTs are based on the effects arising from the application of PSTs on the border between Poland and Germany. The results demonstrate that the use of PSTs in the CEE region can provide effective control of active power flows in tie-lines and significantly reduce unscheduled flows. However, the operation of these devices must be coordinated in order to achieve maximum controllability and to guarantee the secure operation of the interconnected systems.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2016, 64, 1; 127-133
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of the Use of a Matrix Converter for Building a Phase Shifter
Studium wykorzystania przekształtnika macierzowego do budowy przesuwnika fazowego
Autorzy:
Sieńko, T.
Szczepanik, J.
Powiązania:
https://bibliotekanauki.pl/articles/397609.pdf
Data publikacji:
2015
Wydawca:
ENERGA
Tematy:
przekształtnik macierzowy
przesuwnik fazowy
FACTS
kontrola rozpływu mocy
niezawodność systemu elektroenergetycznego
układy wielofazowe
matrix converter
phase shifter
power flow control
power system reliability
multi-phase system
Opis:
This paper presents an analysis of the application of a multi-phase matrix converter (PM) based device as a phase shifter (PS). The analysis was conducted using simulation techniques and measurements performed on a six-phase converter model built in a laboratory. Three basic control schemes and their relation to PM properties are presented. In addition to the phase shifter’s ability to change active power transfer, the device’s impact on reactive power transmission was also shown in the paper. Newly assessed PM properties permit the construction of a PS with higher power system control capacity than with currently available devices. Capabilities of various variants of PM control and fast rate of response of the PS based on it, will undoubtedly be useful in the control of dynamic states of the power system operation (postdisturbance states), e.g. for rapid elimination of generator oscillations or power flow adjustment. This study is an extension of the phase shifter concept presented in previous years, and the continuation assumes the construction of a shifter model for use in an already developed at Cracow University of Technology power system model.
W artykule została zaprezentowana analiza zastosowania wielofazowego przekształtnika macierzowego (PM) do budowy przesuwnika fazowego (PS). Analizę przeprowadzono za pomocą technik symulacyjnych oraz pomiarów wykonanych na sześciofazowym modelu przekształtnika zbudowanym w laboratorium. Zaprezentowano trzy podstawowe schematy kontroli oraz ich związek z własnościami PM. Poza zdolnością przesuwnika fazowego do zmiany transferu mocy czynnej interesujący jest wpływ urządzenia na transmisję mocy biernej, co ukazano w artykule. Nowo pokazane właściwości PM pozwalają na budowę PS o większych możliwościach kontroli systemu elektroenergetycznego (SEE) niż obecnie dostępne urządzenia. Możliwości różnych wariantów sterowania PM oraz duża prędkość reakcji bazującego na nim PS będą niewątpliwie przydatne w kontroli stanów dynamicznych pracy SEE (stanach pozaburzeniowych), np. do szybkiej likwidacji kołysań generatorów czy regulacji rozpływu mocy. Przedstawiona praca jest rozwinięciem koncepcji przesuwnika fazowego prezentowanego w poprzednich latach, a dalszy ciąg zakłada budowę modelu przesuwnika do zastosowania w wykonanym już modelu systemu elektroenergetycznego.
Źródło:
Acta Energetica; 2015, 2; 125-139
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System dynamicznego zarządzania zdolnościami przesyłowymi w systemach elektroenergetycznych
Dynamic management of transmission capacity in power systems
Autorzy:
Kacejko, P.
Kmak, J.
Nowak, W.
Pijarski, P.
Szpyra, W.
Tarko, R.
Wydra, M.
Powiązania:
https://bibliotekanauki.pl/articles/266361.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
overhead transmission lines
dynamic transmission line rating
monitoring of transmission line
power flow control
elektroenergetyczne linie napowietrzne
dynamiczna obciążalność linii
monitorowanie warunków pracy linii
sterowanie rozpływem mocy
Opis:
W artykule omówiono wpływ obciążenia i warunków atmosferycznych na obciążalność elektroenergetycznych linii napowietrznych, oraz metody wykorzystywane do wyznaczania dynamicznej obciążalności tych linii. Przedstawiono wybrane zagadnienia dotyczące Systemu Dynamicznego Zarządzania Przesyłem (SDZP), opracowanego w ramach projektu badawczorozwojowego GEKON, a w szczególności algorytm wyznaczania obciążalności linii w zależności od warunków atmosferycznych oraz algorytm sterowania rozpływem mocy, wykorzystywany gdy obciążalność niektórych linii jest w danych warunkach niewystarczająca. Przedstawiono również aspekty ekonomiczne zastosowania SDZP.
The capacity of overhead power lines depends on, among others, the currently prevailing in the area weather conditions. These conditions may vary over a wide range in both time and space. In practice, often uses static load (eg. summer and winter) specified for the fixed weather conditions. Such an approach may result, however, limit the use of transmission lines capacity, especially designed for the allowable wire temperature + 40°C. The actual line load is the basis for optimization of the SEE and determining the participation of generating sources. When the capacity of some lines is not sufficient, it is necessary to change the distribution of power generation between power plants. This causes additional costs on the balancing market (costs of congestion management). For these reasons, the aim is to determine the dynamic allowable load of power line, which determines both the load current (at the time) based on current weather conditions and forecast in based on forecasted weather conditions. The article presents selected issues of Dynamic Power Flow Management System (SDZP), developed in the research project GECKON. It also presents the economic aspects of the use SDZP.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 53; 107-110
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies