Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Lemna System" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Duckweed does not improve the efficiency of municipal wastewater treatment in Lemna System plants
Rzęsa nie poprawia efektywności oczyszczania ścieków komunalnych w oczyszczalniach typu Lemna System
Autorzy:
Ozimek, T.
Dąbrowski, W.
Florkiewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/205440.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
municipal wastewater
constructed wetland
Lemna System
Lemna minor
ścieki komunalne
oczyszczalnia ścieków
Lemna system
staw napowietrzny
Opis:
his study investigated the operation of three full-scale Lemna System surface flow municipal wastewater treatment plants, built according to the Lemna Corporation design. These plants consist of two ponds, the first aerated and the second for duckweed, with a barrier grid in the latter to ensure uniform plant distribution across its area. According to designers duckweed improves the efficiency of wastewater treatment. The three treatment plants are situated in central Poland and they differ in the occurrence of duckweed, two of them, located in Raków and Bąkowiec, operate without duckweed. and the third in Falęcin Stary, Lemna minor covers ca. 90% of second pond surface. The efficiency of Lemna System wastewater treatment was found not to differ between the plants with and without duckweed. The aerated pond played the main role in reduction of pollutants in the investigated Lemna Systems.
Badania prowadzono w trzech czyszczalniach hydrofi towych z powierzchniowym przepływem ścieków typu Lemna System, zbudowanych według projektu Lemna Corporation. Składają się one ze stawu napowietrzanego i stawu rzęsowego wyposażonego w system barier mających na celu równomierne rozmieszczenie roślin. Stawy poprzedzone są osadnikiem wstępnym. Według projektantów odpowiednia praca tych oczyszczalni związana jest z występowaniem rzęsy na powierzchni stawu rzęsowego. Badano efektywność oczyszczania ścieków komunalnych w trzech oczyszczalniach Lemna System usytuowanych w centralnej Polsce ze szczególnym uwzględnieniem roli stawu rzęsowego i samej rzęsy. Oczyszczalnie różniły się między sobą występowaniem rzęsy. W dwóch z nich (w Rakowie i Bąkowcu) w trakcie całego okresu badań rzęsa nie występowała, natomiast w trzeciej (w Falęcinie Starym) w okresie wegetacyjnym pokrywała do 90%.powierzchni stawu. Efektywność oczyszczanie ścieków nie różniła się w oczyszczalni z rzęsą i bez rzęsy. Rzęsa nie wpływała istotnie na efektywność oczyszczania ścieków. We wszystkich oczyszczalniach główną rolę w redukcji zanieczyszczeń odgrywał staw napowietrzany.
Źródło:
Archives of Environmental Protection; 2015, 41, 3; 47-52
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania efektywności pracy oczyszczalni gruntowo-roślinnych i wodno-roślinnych typu "Lemna"
Effectiveness of sewage treatment plants involving soil-vegetable and water-vegetable (Lemna-type)
Autorzy:
Czyżyk, F.
Powiązania:
https://bibliotekanauki.pl/articles/236596.pdf
Data publikacji:
2003
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczalnie hydrobotaniczne
system Lemna
hydrophyte treatment systems
Lemna-type
Opis:
Omówiono wyniki badań efektywności pracy czterech hydrobotanicznych oczyszczalni ścieków. Badania przeprowadzono w latach 1996-1998 na pracujących od 1995 r. dwóch oczyszczalniach gruntowo-trzcinowych (Morawa i Szklarka) oraz dwóch oczyszczalniach wodno-roślinnych typu "Lemna" (Kochcice i Pawonków). Stwierdzono, że efektywność oczyszczania ścieków w badanych oczyszczalni była bardzo zróżnicowana, co było spowodowane odmiennymi warunkami ich pracy. Oczyszczalnia gruntowo-trzcinowa w Morawie nie dawała dobrych efektów oczyszczania ścieków z uwagi na błędna lokalizację, gdyż została ona umieszczona w terenie zacienionym, co skutkowało słabym systemem korzeniowym. Wymagany stopień oczyszczania ścieków uzyskano dopiero w stawie doczyszczającym. Wyniki oczyszczania ścieków w dwóch oczyszczalniach typu "Lemna" były również zróżnicowane. Usuwanie zanieczyszczeń na oczyszczalni w Kochcicach było znacznie niższe niż w Pawonkowie. Szczególnie niskie było usuwanie związków azotu i fosforu. Oczyszczalnia w Kochciacach pracowała jednak w warunkach dużego przeciążania ściekami w stosunku do obciążeń projektowanych. Kontrolne badania na oczyszczalniach typu "Lemna" wykonane w 2000 r. wykazały oznaki pogorszenia pracy oczyszczalni wraz z ich wiekiem. Wystąpiły objawy wtórnego zanieczyszczania odpływających ścieków, takie jak wzrost zawartości zawiesin ogólnych, azotu amonowego i natężenie uciążliwych zapachów, czego przyczyną było gromadzenie się słabo ustabilizowanych osadów organicznych na dnie stawów doczyszczających i ich fermentacja.
The investigations covered the time span of 1996-1998 and were carried out in two sewage treatment plants working with a soil-reed bed (Morawa and Szklarka) and two sewage treatment plants involving a Lemna-type water-vegetable bed (Kochcice and Pawonków). Treatment efficiency was found to vary from one plant to another, which should be attributed to the differences in the operating conditions. The low treatment efficiency obtained with the soil-reed bed in Morawa should be attributed to the location of the treatment plant in a shaded area, which resulted in a poorly developed root system. The desired treatment effect was achieved only after having passed the wastewater to the secondary pond. The treatment efficiencies obtained in the two Lemna-type plants also differ from each other. The treatment effects in Kochcice were much poorer than in Pawonków, and this holds particularly for the removal of nitrogen and phosphorus compounds. It was so because the Kochcice plant worked under a high overloading as compared to the design value. A testing study of the two Lemna-type sewage treatment plants carried out in 2000 revealed a continuing decrease in treatment efficiency with time. There were symptoms of self-contamination in the effluent (increased TSS, ammonia nitrogen, intensifying objectionable odour) produced by the accumulation of poorly stabilized organic sludges on the bottom of the secondary pond.
Źródło:
Ochrona Środowiska; 2003, R. 25, nr 2, 2; 57-60
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hydrobotaniczne oczyszczalnie ścieków
Autorzy:
Gołąb, M.
Nocoń, W.
Michalski, R.
Powiązania:
https://bibliotekanauki.pl/articles/273982.pdf
Data publikacji:
2012
Wydawca:
Roble
Tematy:
oczyszczanie ścieków
oczyszczalnia ścieków
hydrobotaniczna oczyszczalnia ścieków
system Lemna
wastewater treatment
wastewater treatment plant
hydrobotanic wastewater treatment plant
Lemna-type
Źródło:
LAB Laboratoria, Aparatura, Badania; 2012, 17, 4; 6-10
1427-5619
Pojawia się w:
LAB Laboratoria, Aparatura, Badania
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Use of Hydrophytes for Additional Treatmnet of Municipal Sewage
Autorzy:
Pichura, Vitalii
Potravka, Larisa
Ushkarenko, Viktor
Chaban, Viktor
Mynkin, Mykola
Powiązania:
https://bibliotekanauki.pl/articles/2086397.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
water quality
sewage
treatment system
Eichhornia crassipes
Lemna minor
pollutant
water treatment
Opis:
At the current stage of discharge and treatment of municipal sewage and other types of wastewater in the territory of Ukraine, traditional technologies of biological treatment in aero-tanks by the process of aerobic oxidation involving active silt characterized by low efficiency are largely used. It was established that biological treatment and additional treatment of sewage involving hydrophytes are efficient. The research on wastewater quality and the efficiency of sewage treatment was conducted in three phases: Phase 1 – “the quality before treatment”, Phase 2 – “the quality after mechanical-biological treatment” at the existing municipal treatment plants, Phase 3 – “the quality after additional treatment by hydrophytes”. In order to determine the efficiency of using hydrophytes additional treatment, Eichhornia crassipes (water hyacinth) and the perennial aquatic plant Lemna minor were planted in one treatment pond. The results of the experiment made it possible to determine high efficiency of using hydrophytes for additional sewage treatment. In particular, the efficiency of additional treatment in the treatment ponds removing the residue of suspended pollutants for 40 days was 32%, toxic salts – 13.0–23.0%, oil products – 30.0%, biogenic substances – 68.5–83.3%. It caused a drop in the values of chemical and biological oxygen demand for 5 days by 89.6% and 61.2%, respectively. The efficiency of sewage treatment removing toxic salts and oil products reached 97.7%, whereas in the case of mineral and organic pollutants – up to 99%. That contributed to a considerable increase in the wastewater quality by the criteria for fisheries. In particular, high nutritional value of Eichhornia crassipes and Lemna minor allowed obtaining 12.5 tons of hydrophyte wet mass that can be used as green manure, feeds for farm animals, poultry and fish.
Źródło:
Journal of Ecological Engineering; 2022, 23, 5; 54--63
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies