Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Ryniewicz, Wojciech" wg kryterium: Autor


Wyświetlanie 1-9 z 9
Tytuł:
Evaluation of geometric parameters of the stomatognathic system using radiological imaging
Autorzy:
Ryniewicz, Wojciech
Bojko, Łukasz
Ryniewicz, Anna M.
Powiązania:
https://bibliotekanauki.pl/articles/2173888.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pantomography
cephalometry
CBCT
craniofacial
biometrology
Opis:
In modern clinical practice in various areas of dentistry, there is a need to virtualize and determine the diagnostic parameters of the stomatognathic system (SS). The aim of this article is to provide an evaluation of correct SS structures based on a comparison of mappings in pantomography, lateral cephalometry, and volumetric tomography using bone and tooth anthropometric points. The digital measurements performed determine the applicability of the analyzed imaging techniques for clinical diagnostics by indicating discrepancies and errors in the evaluation of geometric parameters. They should verify the location of characteristic points, lines, angles, and planes in relation to spatial objects mapped on the 1:1 scale. The analyses performed confirm the appearance of bone and dental structure asymmetry in healthy patients.
Źródło:
Metrology and Measurement Systems; 2022, 29, 3; 585--600
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of skull bone structures in CT imaging
Autorzy:
Ryniewicz, Andrzej
Ryniewicz, Wojciech
Wyrąbek, Stanisław
Bojko, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/140116.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
skull
shape
imaging precision
spiral computed tomography
CT
reverse engineering
czaszka
kształt
dokładność obrazowania
spiralna tomografia komputerowa
inżynieria odwrotna
Opis:
At the current stage of diagnostics and therapy, it is necessary to perform a geometric evaluation of facial skull bone structures basing upon virtually reconstructed objects or replicated objects with reverse engineering. The objective hereof is an analysis of imaging precision for cranial bone structures basing upon spiral tomography and in relation to the reference model with the use of laser scanning. Evaluated was the precision of skull reconstruction in 3D printing, and it was compared with the real object, topography model and reference model. The performed investigations allowed identifying the CT imaging accuracy for cranial bone structures the development of and 3D models as well as replicating its shape in printed models. The execution of the project permits one to determine the uncertainty of components in the following procedures: CT imaging, development of numerical models and 3D printing of objects, which allows one to determine the complex uncertainty in medical applications.
Źródło:
Archive of Mechanical Engineering; 2019, LXVI, 1; 83-95
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Simulation Assessment of the Veneering Layers of Prosthetic Crowns in Concentrated Contact
Symulacyjna ocena warstw licujących korony protetyczne w styku skoncentrowanym
Autorzy:
Ryniewicz, Wojciech
Ryniewicz, Anna M
Bojko, Łukasz
Mazur, Konrad
Powiązania:
https://bibliotekanauki.pl/articles/1857800.pdf
Data publikacji:
2020
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
prosthetic restorations
layered materials
FEM simulation
konstrukcje protetyczne
materiały warstwowe
symulacja MES
Opis:
The aim of the study is to simulate and analyse the distributions of stresses and resultant displacements during concentrated loading of the layered material compositions used in prosthetic crowns in order to assess their resistance and demonstrate the impact of strength parameters of the veneer and framework on the transfer of external loads. The research materials are samples replicating the layered structure of prosthetic crowns. The load-bearing layers were made using CAD/CAM technology, and the dedicated veneering layers were fired or polymerized on the frameworks and constituted the top structure for cooperation during occlusion. If the material of the veneering layer differs from the material building the framework, for example, in the ceramic-metal type, spreading of the resultant displacements to the framework and high values of shear stress at the border of the veneering layer and the framework may be unfavourable and cause the veneer layer to chip off. This distribution of stresses and displacements may have a much smaller impact on the ceramic veneering of a ceramic or glass-ceramic framework, as both layers are much more homogeneous in terms of material.
Celem pracy jest symulacja i analiza procesu rozchodzenia się naprężeń i przemieszczeń w trakcie skoncentrowanego obciążenia warstwowych kompozycji materiałowych stosowanych w koronach protetycznych, która pozwala na ocenę ich odporności oraz wykazanie wpływu parametrów wytrzymałościowych licowania i podbudowy na przenoszenie obciążeń zewnętrznych. Materiałem badań są próbki replikujące warstwową budowę koron protetycznych. Warstwy nośne zostały wytworzone w technologii CAD/CAM, a dedykowane warstwy licujące były napalane lub polimeryzowane na podbudowach i stanowiły wierzchnią strukturę do współpracy w warunkach okluzji. W przypadku zróżnicowania materiałowego warstwy licowania od podbudowy, typu ceramika – metal, zjawiska rozprzestrzeniania się przemieszczeń wypadkowych do podbudowy oraz duże wartości naprężeń stycznych na granicy warstwy licującej i podbudowy mogą być niekorzystne i powodować odpryskiwanie warstwy licującej. Taki rozkład naprężeń i przemieszczeń może w znacznie mniejszym stopniu oddziaływać na licowanie ceramiką podbudowy ceramicznej lub szklanoceramicznej, ponieważ obie warstwy są znacznie bardziej jednorodne materiałowo.
Źródło:
Tribologia; 2020, 293, 5; 39-50
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the Impact of Biomateriał and the Technology of Prosthetic Crowns Manufacturing on The Connection with Veneering Ceramics
Analiza wpływu biomateriału i technologii wytworzenia koron protetycznych na łączenie z ceramiką licującą
Autorzy:
Ryniewicz, Anna M.
Ryniewicz, Andrzej
Bojko, Łukasz
Ryniewicz, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/1857795.pdf
Data publikacji:
2020
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
layered structures
CAD/CAM milling
SLM
concentrated contact
microhardness
struktury warstwowe
frezowanie CAD/CAM
styk skoncentrowany
mikrotwardość
Opis:
The aim of the study is to identify the endurance parameters of prosthetic crowns veneered with dedicated ceramics on metal, glass-ceramic, and ceramic frameworks. Metal frameworks were made using CAD/CAM milling technology and SLM technology, while the glass-ceramic and ceramic frameworks were produced using only the CAD/CAM milling technology. The research materials are samples replicating the layered structures of prosthetic crowns. The veneering procedure must ensure the adhesion of the ceramics to the loadbearing framework. The tests modelling the conditions of concentrated loads during chewing were carried out using the Instron 3345 testing machine. Determination of microhardness in cross-sections through layered structures of crowns was performed using the HMV Micro Hardness Tester. The comparison of force loading the indenter as a function of penetration depth indicates that the value of the maximum depth depends on the configuration of microhardness of the framework and dentine. The zirconium ceramics ZrO2 (3Y-TZP) – veneered with Elephant Sakura silica ceramics – should be indicated as the most advantageous material composition.
Celem pracy jest identyfikacja parametrów wytrzymałościowych koron protetycznych licowanych dedykowanymi ceramikami na podbudowach metalowych, szklanoceramicznych i ceramicznych. Podbudowy metalowe zostały wytworzone w technologii frezowania CAD/CAM i w technologii SLM, a podbudowy szklanoceramiczne i ceramiczne w technologii frezowania CAD/CAM. Materiałem badań są próbki replikujące warstwowe struktury koron protetycznych. W wyniku procedury licowania musi być zapewniona adhezjaceramiki do podbudowy nośnej. Badania modelujące warunki skoncentrowanych obciążeń podczas żucia wykonano na maszynie wytrzymałościowej Instron 3345. Wyznaczenie mikrotwardości w przekrojach przez warstwowe struktury koron zrealizowano na maszynie HMV Micro Hardness Tester. Zestawienie siły obciążającej wgłębnik w funkcji głębokości penetracji wskazuje, że wartość maksymalnego zagłębienia, zależy od konfiguracji mikrotwardości podbudowy i mikrotwardości dentyny. Jako najkorzystniejszą kompozycję materiałową należałoby wskazać ceramikę cyrkonową ZrO2 (3Y – TZP) – licowaną ceramiką krzemionkową Elephant Sakura.
Źródło:
Tribologia; 2020, 293, 5; 17-25
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of the Position of the Mandible on Stresses and Displacements within the Structures of the Temporomandibular Joint
Wpływ położenia żuchwy na naprężenia i przemieszczenia w strukturach stawu skroniowo-żuchwowego
Autorzy:
Ryniewicz, Anna M.
Mazur, Konrad
Bojko, Łukasz
Ryniewicz, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/1857799.pdf
Data publikacji:
2020
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
temporomandibular joint
modeling
strength simulations
staw skroniowo-żuchwowy
modelowanie
symulacje wytrzymałościowe
Opis:
A model of the temporomandibular joint (TMJ) was developed using the finite element method (FEM). The aim of the procedure is to identify reduced stresses and resultant displacements in the TMJ and to evaluate the transfer of contact loads for the three articulation states of the mandible that represent the activity of the joint. The study mapped the layered structure of the bio-bearing with different strength parameters of the tissues and synovial fluid. The model was loaded with the forces generated by the mandibular abduction muscles during chewing. Our method allowed for the assessment of the transfer of physiological loads within surfaces when lubricating with the synovial fluid and showed compressive stimulation of bone structures. Under load transfer conditions, the maximum values of reduced stresses are located not in the immediate friction zone, but in the structures of the compact and spongy bone.
Opracowano model stawu skroniowo-żuchwowego (SSŻ) z wykorzystaniem metody elementów skończonych (MES). Celem jest identyfikacja naprężeń zredukowanych i przemieszczeń wypadkowych w SSŻ oraz ocena przeniesienia obciążeń kontaktowych dla trzech stanów artykulacyjnych żuchwy, które są reprezentatywne dla czynności tego stawu. W badaniu odwzorowano warstwową budowę biołożyska o zróżnicowanych parametrach wytrzymałościowych tkanek oraz cieczy synowialnej. Model obciążono siłami generowanymi przez mięśnie odwodzące żuchwę w warunkach żucia pokarmów. Zaproponowana metoda pozwoliła na ocenę przeniesienia obciążeń fizjologicznych w stawie skroniowo-żuchwowym. Umożliwiła analizę funkcjonalną krążka stawowego i powierzchni stawowych w warunkach smarowania cieczą synowialną oraz wskazała na stymulację kompresyjną struktur kostnych. W warunkach przenoszenia obciążeń maksymalne wartości naprężeń zredukowanych zlokalizowane są nie w bezpośredniej strefie tarcia, ale w strukturach kości korowej i gąbczastej.
Źródło:
Tribologia; 2020, 293, 5; 27-38
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microstructural and Micromechanical Tests of Titanium Crowns
Badania mikrostrukturalne i mikromechaniczne koron tytanowych
Autorzy:
Ryniewicz, Wojciech
Bojko, Łukasz
Pałka, Paweł
Osada, Piotr
Ryniewicz, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/2200622.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
prosthetics
titanium alloy
fixed structure
digital technology
biomechanics
protetyka
stop tytanu
konstrukcja stała
technologia cyfrowa
biomechanika
Opis:
Fixed prosthetic restorations must meet the health requirements in terms of the protection of the tissues of the oral cavity, biomechanical requirements for optimal tissue stress and the strength and wear resistance of the structure, aesthetic requirements related to the location of the gingival margin, as well as the shape, thickness, and colour of the veneers. The aim is to evaluate the impact of manufacturing technology on the microstructure and micromechanical parameters of titanium crowns. The material of the analysis are prosthetic crowns made of Ti6Al4V alloy for the maxilla premolars and the mandible molars, produced using two technologies: Selective Laser Melting (SLM) and CAD/CAM milling. Crown structures were evaluated on the basis of examinations of the microstructure and surface layer of the chamfers, micromechanical parameters in axial sections perpendicular to the dental arches, and the accuracy of mapping the internal shape in sections with horizontal planes perpendicular to the axis of the abutment tooth. The results of this work can be used in a clinical setting. They allow the evaluation of what is the impact of the technology of producing the supporting substructure on the structure of the prosthetic crown. The strength requirements in both technologies are met, while the higher value of the microhardness of the titanium SLM substructure, compared to the milled one, increases the stiffness of the structure under conditions of biomechanical excitation. The errors in mapping the internal shape of the crowns are comparable and slightly higher during sintering.
Stałe uzupełnienia protetyczne powinny spełniać wymagania zdrowotne w aspekcie zabezpieczenia tkanek jamy ustnej, wymagania biomechaniczne dotyczące optymalnego wytężenia tkanek oraz wytrzymałości i odporności na zużycie konstrukcji, wymagania estetyczne związane z usytuowaniem obrzeża dodziąsłowego, a także kształtem, grubością i kolorem licowania. Celem jest ocena wpływu technologii wytwarzania na mikrostrukturę i parametry mikromechaniczne koron tytanowych. Materiałem analizy są korony protetyczne ze stopu Ti6Al4V na zęby przedtrzonowe szczęki i trzonowe żuchwy wytwarzane dwoma technologiami: Selective Laser Melting (SLM) i frezowania CAD/CAM. Konstrukcje koron oceniano na podstawie badań mikrostruktury i warstwy wierzchniej stopni, parametrów mikromechanicznych w osiowych przekrojach prostopadłych do łuków zębowych oraz dokładności odwzorowania kształtu wewnętrznego w przekrojach płaszczyznami horyzontalnymi, prostopadłymi do osi zęba filarowego. Wyniki tej pracy mogą być wykorzystane w warunkach klinicznych. Pozwalają ocenić, jaki jest wpływ technologii wytworzenia podbudowy nośnej, na konstrukcję korony protetycznej. Wymagania wytrzymałościowe w obu technologiach są spełnione, przy czym wyższa wartość mikrotwardości podbudowy tytanowej z SLM, w porównaniu do frezowanej, wpływa na zwiększenie sztywności konstrukcji w warunkach wymuszeń biomechanicznych. Błędy odwzorowania kształtu wewnętrznego koron są porównywalne i nieco wyższe przy spiekaniu.
Źródło:
Tribologia; 2022, 4; 61--72
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Assessment of the Layered Structure of Prosthetic Crowns in Microscopic Examinations
Ocena warstwowej budowy koron protetycznych w badaniach mikroskopowych
Autorzy:
Ryniewicz, Andrzej
Ryniewicz, Anna M.
Bojko, Łukasz
Pałka, Paweł
Ryniewicz, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/1857790.pdf
Data publikacji:
2020
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
veneering layer
digital frameworks
EDS
adhesion
warstwa licująca
podbudowy cyfrowe
adhezja
Opis:
Prosthetic crowns are made in accordance with the principles of clinical procedures while taking into account the rules of endurance, biocompatibility, and aesthetics. Depending on the biomaterial and manufacturing technology, crown frameworks are veneered with an appropriate set of ceramics with selected thermal expansion. The veneering layers responsible for tribological cooperation in occlusal contact should properly adhere to the framework. The aim of the research is to conduct the microscopic and EDS chemical analysis to evaluate the process of shaping veneering layers on frameworks produced using new digital technologies, i.e. the technology of milling and laser sintering. The research material consists of specimens produced in perpendicular cross-sections through the layered structures of metal-ceramic, ceramic-veneered glassceramic, and zirconium crowns. The microscopic examinations were carried out using the specimens and included the elemental EDS analysis performed on the surfaces and in certain points. The structures of metal and ceramic frameworks, ceramic veneering layers, and adhesive zones were determined.
Korony protetyczne wykonywane są zgodnie z procedurami klinicznymi oraz ze wskazaniami wytrzymałości, biozgodności i estetyki. Podbudowy koron, w zależności od zastosowanego biomateriału i technologii wytworzenia, poddawane są licowaniu odpowiednim zestawem ceramik o dobranej ekspansji termicznej. Warstwy licujące, odpowiedzialne za współpracę tribologiczną w kontakcie okluzyjnym, powinny charakteryzować się właściwą adhezją do podbudowy. Celem przeprowadzonych badań jest analiza mikroskopowa i chemiczna EDS pozwalająca ocenić proces kształtowania warstw licujących na podbudowach wytworzonych w nowych technologiach cyfrowych: w technologii frezowania oraz w technologii spiekania laserowego. Materiałem badań są zgłady wykonane w przekrojach prostopadłych przez warstwowe struktury koron: metalowo-ceramicznych, szklano-ceramicznych licowanych ceramiką i cyrkonowych licowanych ceramiką. Na zgładach przeprowadzono badania mikroskopowe z analizą pierwiastkową EDS na powierzchniach oraz w punktach. Identyfikowano struktury metalowych i ceramicznych podbudów oraz strukturę ceramicznych warstw licujących wraz ze strefami adhezyjnymi.
Źródło:
Tribologia; 2020, 292, 4; 59-70
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tribological Studies of Layered Biomaterials for Prosthetic Structures Based on Substructures Made of Digital Technologies
Badania tribologiczne biomateriałów warstwowych na konstrukcje protetyczne o podbudowach z technologii cyfrowych
Autorzy:
Ryniewicz, Wojciech
Bojko, Łukasz
Ryniewicz, Anna M.
Pihut, Małgorzata
Pałka, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/188063.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
digital technologies
prosthetic substructures
veneering ceramics
friction
wear
SEM
technologie cyfrowe
podbudowy protetyczne
ceramiki licujące
tarcie
zużycie
Opis:
Modern dental prosthetics uses CAD/CAM in the Computer Aided Design (CAD) of substructures and its Computer Aided Manufacturing (CAM) process. The substructure is subject to appropriate veneering, which determines the functional cooperation. The aim of this study is to investigate the friction coefficient and wear resistance of the veneering layers of the substructures of prosthetic structures. The test materials are dedicated veneering layers on substructures made of factory-made CoCr, TiCP, and Ti6Al4V metal fittings as well as the glass-ceramic material LiSi2 and the ceramic ZrO2. The study was conducted on a Roxana Machine Works tribological machine in the ball-and-3discs system in an artificial saliva environment using a Hitachi S3400 scanning microscope. As a reference biomaterial, enamel-dentin discs were used. The tribological processes that take place under chewing conditions in the presence of saliva depend on the properties and technological parameters of the surface layer of the biomaterial wearing out and on the enamel of opposing teeth in contact, which also wears out. They should reproduce the physiological nature of adjustment wear in the stomatognathic system (SS). The determined values of the friction coefficient and wear resistance allowed differences to be indicated in the course of tribological processes, and microscopic analyses confirmed them.
Współczesna protetyka stomatologiczna wykorzystuje system CAD/CAM do cyfrowego projektowania podbudowy konstrukcji (CAD) oraz do jej wytwarzania w sterowanym numerycznie procesie (CAM). Podbudowa nośna poddawana jest odpowiedniemu licowaniu, które decyduje o funkcjonalnej współpracy. Celem pracy jest badanie współczynnika tarcia i odporności na zużycie warstw licujących podbudowy konstrukcji protetycznych. Materiałem badań są dedykowane warstwy licujące na podbudowach wykonanych w technologii frezowania z fabrycznych kształtek z metali – CoCr, TiCP i Ti6Al4V oraz z materiałów szklano-ceramicznych LiSi2 i ceramicznych ZrO2. Badania wykonano na maszynie tribologicznej Roxana Machine Works w układzie kula-3krążki w środowisku sztucznej śliny oraz na mikroskopie skaningowym Hitachi S3400. Jako biomateriał referencyjny wykorzystano krążki szkliwno-zębinowe. Procesy tribologiczne, które zachodzą w warunkach żucia w obecności śliny uzależnione są od właściwości i parametrów technologicznych warstwy wierzchniej zużywającego się biomateriału oraz od szkliwa zębów przeciwstawnych wchodzących w kontakt, które również się zużywają. Powinny odtwarzać fizjologiczny charakter zużycia dostosowawczego w układzie stomatognatycznym (US). Wyznaczone wartości współczynnika tarcia i odporności na zużycie pozwoliły na wskazanie różnic w przebiegu procesów tribologicznych, a analizy mikroskopowe to potwierdziły.
Źródło:
Tribologia; 2019, 287, 5; 87-99
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of surface microgeometry and structure of layered biomaterials used for prosthetic constructions in digital technologies
Analiza mikrogeometrii powierzchni i struktury biomateriałów warstwowych stosowanych na konstrukcje protetyczne w technologiach cyfrowych
Autorzy:
Ryniewicz, Wojciech
Ryniewicz, Anna M.
Bojko, Łukasz
Leszczyńska-Madej, Beata
Ryniewicz, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/189984.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
prosthetic construction
substructure
veneering layer
microgeometry
structure
roughness
konstrukcja protetyczna
podbudowa
warstwa licująca
mikrogeometria
struktura
chropowatość
Opis:
Veneering layers of prosthetic substructures are responsible for tribological cooperation with opposite teeth in the stomatognathic system (SS). Investigations of microgeometry and structure of veneering layers are aimed at checking to what extent these layers replicate enamel parameters, which, under complex load conditions, are characterized by the phenomenon of resistance to tribological wear. Ceramic veneering layers are dedicated for substructures made in digital technologies from factory fittings by milling and laser sintering of metal powders. Using a confocal microscope, contactless tests of the surface layer stereometry were performed and surface roughness parameters were determined on samples of ceramics veneering of prosthetic substructures. The analysis was performed in comparison to the natural enamel of premolars and molars. The shaping of the surface of materials veneering the substructures is similar to the regularity determined in the statistical analysis of the enamel roughness. Layers facing samples from milling technology are characterized by lower values of roughness parameters than layers created on substructures made of SLM technology.
Warstwy licujące podbudowy protetyczne są odpowiedzialne za współpracę tribologiczną z zębami przeciwstawnymi w układzie stomatognatycznym (US). Badania mikrogeometrii i struktury warstw licujących mają na celu sprawdzenie, w jakim stopniu warstwy te replikują parametry szkliwa, które w złożonych warunkach obciążeń charakteryzuje się fenomenem odporności na zużycie tribologiczne. Materiałem badań są ceramiczne warstwy licujące dedykowane na podbudowy wykonane w technologiach cyfrowych: z fabrycznych kształtek metodą frezowania oraz technologią spiekania laserowego z proszków metali. Z wykorzystaniem mikroskopu konfokalnego wykonano bezstykowe badania stereometrii warstwy wierzchniej oraz wyznaczono parametry chropowatości powierzchni na próbkach ceramik licujących podbudowy protetyczne. Analizę przeprowadzono w porównaniu ze szkliwem naturalnym zębów przedtrzonowych i trzonowych. Ukształtowanie powierzchni materiałów licujących podbudowy w różnym stopniu zbliża się do regularności wyznaczonej w statystycznej analizie chropowatości szkliwa. Warstwy licujące próbki z technologii frezowania charakteryzują się niższymi wartościami parametrów chropowatości niż warstwy utworzone na podbudowach z technologii SLM.
Źródło:
Tribologia; 2019, 287, 5; 101-113
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies