Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "transmission lines" wg kryterium: Wszystkie pola


Tytuł:
Lossless transmission lines terminated by crystal oscillator circuit
Autorzy:
Angelov, Vasil G.
Powiązania:
https://bibliotekanauki.pl/articles/1065397.pdf
Data publikacji:
2019
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Fixed point theorem
Kirchhoff’s law
Lossless transmission line
Mixed problem for hyperbolic system
Neutral equation
Periodic solution
Opis:
The present paper deals with ТЕМ propagation of waves along lossless transmission lines terminated by a crystal oscillator circuit. The crystal oscillator circuit generates nonlinear boundary conditions derived by the Kirchhoff’s law. Then the mixed problem for the hyperbolic transmission line system to an initial value problem for neutral system on the boundary is reduced. The main purpose of the present paper is to show an existence-uniqueness of a periodic solution of the neutral system. This is achieved by introducing a suitable operator acting on a space of periodic functions. Its fixed point is a periodic solution of the neutral system. The advantages of the presented method on numerical example are demonstrated. The solution can be obtained by successive approximations.
Źródło:
World Scientific News; 2019, 132; 65-83
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Location of arc faults on power transmission lines
Autorzy:
Pustułka, M
Iżykowski, J
Łukowicz, M
Powiązania:
https://bibliotekanauki.pl/articles/410527.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
arc fault
fault location
signal processing
Opis:
This paper presents a fault location algorithm, which allows to determine the distance to a fault and fault resistance, as a result of considering natural fault loops. It is assumed that three-phase voltages and currents from both ends of the line measured asynchronously are the input signals of the fault locator. In case of the availability of synchronized measurements the elements associated with the determination of the synchronization angle should be omitted. In addition to natural fault loop signals also use of symmetrical components (positive and negative or incremental positive sequence components) to fault location were considered as well.
Źródło:
Present Problems of Power System Control; 2013, 3; s. 95-102
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Unified Description of Coupled Resonators and Coupled Transmission Lines
Autorzy:
Abramowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/1505236.pdf
Data publikacji:
2011-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
84.40.Dc
Opis:
Coupled resonators and coupled transmission lines are described with the same coupling curve. A ratio between resonant frequencies, squared, of coupled resonators and ratio between impedances of coupled transmission lines reveal the same type of dependence on coupling coefficient. This can be used to select, adjust or create the models of coupled structures. As an example the new model of coupled transmission lines has been developed. Its application in LC element directional coupler is presented and discussed.
Źródło:
Acta Physica Polonica A; 2011, 119, 4; 548-552
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Manufacturing of Al-Zr Thermal-resistant Alloys for Transmission Lines
Autorzy:
Erturk, A.
Guven, E.
Karabay, S.
Powiązania:
https://bibliotekanauki.pl/articles/1401363.pdf
Data publikacji:
2015-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
81.05.Bx
88.80.H
83.50.Uv
81.70.Jb
81.40.Ef
81.70.Bt
Opis:
The present transmission lines of populous cities will have to be changed with an ability to work at higher temperatures without any weight and cross section changes. Innovative thermal-resistant alloy conductors (T-ACSR) operate in the range of about 150-200°C instead of 75°C which is the standard ACSR type conductor service temperature. In this study, the manufacturing procedure of Al-Zr alloy wire, used as high-temperature conductor wires, have been introduced. The Al-Zr alloy has been cast in a permanent mold than being extruded to a diameter of 10 mm at 400°C. After that the extruded rods have been cold drawn to a diameter of 3.02 mm. Elongation and tensile strength values of the cold drawn wire have been achieved by tensile test at elevated temperatures. Also, microstructural analysis and dispersion hardening procedure have been investigated. The results show that tensile strength and thermal-resistant property are improved by the addition of Zr.
Źródło:
Acta Physica Polonica A; 2015, 127, 4; 1292-1294
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fault location in EHV transmission lines using artificial neural networks
Autorzy:
Bouthiba, T.
Powiązania:
https://bibliotekanauki.pl/articles/907284.pdf
Data publikacji:
2004
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
linia przesyłowa
detekcja uszkodzeń
lokalizacja uszkodzeń
sztuczna sieć neuronowa
transmission line
fault detection
fault location
artificial neural networks
Opis:
This paper deals with the application of artificial neural networks (ANNs) to fault detection and location in extra high voltage (EHV) transmission lines for high speed protection using terminal line data. The proposed neural fault detector and locator were trained using various sets of data available from a selected power network model and simulating different fault scenarios (fault types, fault locations, fault resistances and fault inception angles) and different power system data (source capacities, source voltages, source angles, time constants of the sources). Three fault locators are proposed and a comparative study of the proposed fault locators is carried out in order to determine which ANN fault locator structure leads to the best performance. The results show that artificial neural networks offer the possibility to be used for on-line fault detection and location in transmission lines and give satisfactory results.
Źródło:
International Journal of Applied Mathematics and Computer Science; 2004, 14, 1; 69-78
1641-876X
2083-8492
Pojawia się w:
International Journal of Applied Mathematics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Neural network filtration for arc faults location on power transmission lines
Autorzy:
Pustułka, M.
Iżykowski, J.
Łukowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/410589.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
arc fault
fault location
signal processing
filtration
Opis:
This paper presents filtration using neural network for arc fault location, which allows to determine the distance to a fault, as a result of considering natural fault loops. It is assumed that three-phase voltages and currents from both ends of the line are the input signals of the fault locator and naturally of the neutral network applied for filtering the input signals. In addition to natural fault loop signals also use of symmetrical components (positive and negative or incremental positive sequence components) to fault location were considered as well. Results of evaluation study have been included, analyzed and discussed. Influence of filtration has been also considered.
Źródło:
Present Problems of Power System Control; 2013, 4; 37-49
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A fault location method for hybrid transmission lines based on empirical Fourier decomposition
Autorzy:
Tao, Caixia
Xing, Baosheng
Li, Taiguo
Powiązania:
https://bibliotekanauki.pl/articles/27309957.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
empirical Fourier decomposition
fault location
hybrid lines
Teager energy operator
traveling wave method
Opis:
This paper aims to address the problems of inaccurate location and large computation in hybrid transmission line traveling wave detection methods. In this paper, a new fault location method based on empirical Fourier decomposition (EFD) and the Teager energy operator (TEO) is proposed. Firstly, the combination of EFD and the TEO is used to detect the time difference between the arrival of the initial traveling wave of the fault at the two measurement ends of the hybrid line. Then, when the fault occurs at the midpoint of each line segment and at the connection point of the hybrid line, the time difference between the arrival of the fault traveling wave at the two measurement ends of the line is calculated according to the line parameters. By comparing the obtained time differences, it is determined whether the fault occurs in the first or second half of the line. Finally, the fault distance is calculated using the double-ended traveling wave method according to the fault section. The model was built on PSCAD and the proposed algorithm was simulated on MATLAB platform. The results demonstrate that the proposed method achieves an average fault location accuracy of 98.88% by adjusting transition resistances and fault distances and comparing with other location methods. After validation, the proposed method for locating faults has a high level of accuracy in location, computational efficiency, and reliability. It can accurately identify fault segments and locations in hybrid transmission line systems.
Źródło:
Archives of Electrical Engineering; 2023, 72, 4; 1035--1053
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Corona Modeling for the Transient Analysis, Steady State and Corona Loss Performance of Transmission Lines
Autorzy:
Saied, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/262685.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
corona
power transmission lines
electromagnetic modeling
computer simulation
losses
transient analysis
shunt compensation
optimization
Opis:
This paper addresses the steady state analysis and the electromagnetic transients of overhead power transmission lines exhibiting corona. After a brief survey of the currently available modeling techniques, an alternative approach to the simulation of the corona discharge is presented. It is based on adding voltage-dependent current sources at prespecified nodes within the line’s lumped, ladder-shaped, equivalent circuit including an aduqate number of sections. The characteristics of these current sources can be determined using the usually available corona power loss measurements under power frequency sinusoidal voltage conditions. The line model is used for finding its transient response using time domain techniques. Several voltage excitation waveforms and magnitudes as well as different line’s loading conditions are investigated. As a further application of the suggested approach, the minimizion of the total corona losses of a long shunt compensated line will be considered as an additional criterion in the process of identifying the appropriate rating and location of the compensating coil primarily used for improving the line’s voltage profile.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2013, 16, 2; 11-20
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biological risk assessment of high-voltage transmission lines on worker’s health of electric society
Autorzy:
Bidi, Manel
Powiązania:
https://bibliotekanauki.pl/articles/141717.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
biological risk
electromagnetic fields
extremely low frequency
induced current
overhead lines
Opis:
A probable risk for different diseases has been reported due to exposure of peoples living in the vicinity of electrical substations and electrical workers. The aim of this paper is to examine and reduce the induced current density due to the power system field acting on human beings in the working environment, by using the spheroidal calculation model. The results obtained by means of computer programs developed by the author in the MATLAB environment are compared with the limit values given by the International Committee on Non-Ionizing Radiation Protection (ICNIRP) for demonstrating the degree of danger due to the induced current and have a certain guidance function for worker’s health to ensure their safety
Źródło:
Archives of Electrical Engineering; 2020, 69, 1; 57-68
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie map cyfrowych w analizie awaryjności linii przesyłowych
Digital maps for transmission lines’ failure frequency analysis
Autorzy:
Dzierżanowski, Ł.
Tomaszewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/377452.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
mapa cyfrowa
zdarzenie awaryjne
linia przesyłowa
energia elektryczna
jakość energii elektrycznej
Opis:
W artykule przedstawiono zarys metodologii pozwalającej na kategoryzację zdarzeń awaryjnych, koncepcję przedstawienia przetworzonych wyników analizy oraz sposób prezentacji danych z wykorzystaniem map cyfrowych. Gospodarka rynkowa wymaga w polskiej elektroenergetyce procesu zmian w metodach i technologiach eksploatacji majątku. Na pierwszy plan wysuwa się problem efektywności ekonomicznej połączony z rosnącymi wymaganiami dotyczącymi jakości energii elektrycznej. Utrzymanie wysokiej niezawodności dostawy energii elektrycznej ma wymiar ekonomiczny w skali przedsiębiorstwa, a także wymiar polityczny w skali państwa. Wymusza to potrzebę redukcji skutków zakłóceń między innymi przez wprowadzenie lepszych metod diagnostycznych i stosowanie systemów monitoringu.
The paper presents a sketch of methodology used for failure incidents categorization along with the idea of displaying processed analysis results on digital maps. The market economy demands a process of changes in methodologies and technologies used in power system maintenance. The problem of economical effectiveness coupled with raising demands for the quality of power supply are growing to be the main concern at the moment. Keeping the reliability of supply at a high level strongly influences the economics of the enterprise and is a great factor in the national safety politics. The need for reduction of failure effects is growing constantly, pressing for the improvement of diagnostic and monitoring systems.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2013, 74; 59-67
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Probabilistic assessment of the short-circuit duration on the 220 kV transmission line basing on simulation analysis
Autorzy:
Frąckowiak, R.
Piechocki, P.
Powiązania:
https://bibliotekanauki.pl/articles/97379.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
transmission lines
current
simulation analysis
Opis:
In the paper, the problem of defining the short circuit duration time for the short-circuit effect calculations, especially thermal and electromagnetic ones, has been discussed. In author’s opinion, the results of probabilistic research could be helpful when resolving the problem. Therefore, a tailored simulation model based on the analysis of the protections and circuit breakers operation during the transmission lines fault clearance has been developed. Due to the results of simulation study, the found values of the fault duration time could be related to the expected risk of their exceeding depending on both the protection system configuration and the type of the circuit breakers applied.
Źródło:
Computer Applications in Electrical Engineering; 2012, 10; 275-282
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Arcing Faults Location Methods for Power Transmission Lines
Metody lokalizacji zwarć łukowych w energetycznych liniach przesyłowych
Autorzy:
Pustułka, M.
Łukowicz, M.
Iżykowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/396832.pdf
Data publikacji:
2014
Wydawca:
ENERGA
Tematy:
fault location
artificial neural network
arcing fault
lokalizacja zwarć
sztuczna sieć neuronowa
zwarcia łukowe
Opis:
This paper presents three different fault location approaches: one-end Takagi algorithm, two-end algorithm considering natural fault loops and neural network. It is assumed that three-phase voltages and currents from both ends of the line measured asynchronously are the input signals of the fault locator. In addition to natural fault loop signals also the use of symmetrical components (positive and negative or incremental positive sequence components) for fault location were considered. Results of the evaluation study have been included, analyzed and discussed. The impact of filtration has also been considered.
W artykule przedstawiono trzy metody lokalizacji zwarć: algorytm Takagi, algorytm wykorzystujący pomiary z dwóch końców linii oraz algorytm z siecią neuronową. Do lokalizacji zwarcia w algorytmach użyto napięcia i prądów mierzonych z obu końców linii. Sieć neuronowa wspomagana była rozwiązaniem uzyskanym za pomocą algorytmu, który w celu określenia miejsca zwarcia, oprócz naturalnych sygnałów pętli zwarciowych, wykorzystywał również sygnały składowych symetrycznych. Przeanalizowany został wpływ filtracji sygnałów zasilających na dokładność algorytmów.
Źródło:
Acta Energetica; 2014, 1; 142-151
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transitional processes at switching-off unloaded power transmission lines by modern circuit-breakers and their computer simulation
Autorzy:
Lazimov, T.
Saafan, E.
Powiązania:
https://bibliotekanauki.pl/articles/410587.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
SF6 circuit-breakers
power transmission lines
computer simulation
transitional voltages
Opis:
The article presents results of transitional processes computer simulation at switching-off unloaded power transmission line of rated voltage 220 kV by auto-compression (SF6) circuit-breakers. Transitional voltages (voltage across the line terminals and recovery voltage) at switching-off were calculated and studied in the research carried out. There was also considered dependence between transitional voltages magnitudes and power transmission lines lengths. There were studied some computational peculiarities of the problem under consideration. In particular, the numbers of pi-sections provided satisfactory adequacy of lines equivalency at computer simulation for their typical lengths were determined. There were also estimated optimum simulation parameters provided stability of transitional regime parameters.
Źródło:
Present Problems of Power System Control; 2013, 4; 67-75
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody lokalizacji zwarć łukowych w energetycznych liniach przesyłowych
Arcing faults location methods for power transmission lines logic
Autorzy:
Pustułka, M.
Łukowicz, M.
Iżykowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/267653.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
lokalizacja zwarć
sztuczna sieć neuronowa
fault location
artificial neural network
arcing fault
Opis:
W artykule przedstawiono trzy metody lokalizacji zwarć: algorytm Takagi, algorytm wykorzystujący pomiary z dwóch końców linii oraz algorytm z siecią neuronową. Do lokalizacji zwarcia w algorytmach wykorzystano napięcia i prądy mierzone z obu końców linii. Sieć neuronowa wspomagana była rozwiązaniem uzyskanym za pomocą algorytmu, który w celu określenia miejsca zwarcia oprócz naturalnych sygnałów pętli zwarciowych wykorzystywał również sygnały składowych symetrycznych.
This paper presents a three different fault location approaches: one-end Takagi algorithm, two-end algorithm considering natural fault loops and neural network. It is assumed that three-phase voltages and currents from both ends of the line measured asynchronously are the input signals of the fault locator. In addition to natural fault loop signals also the use of symmetrical components (positive and negative or incremental positive sequence components) for fault location were considered. Results of evaluation study have been included, analyzed and discussed. Impact of filtration has been considered as well.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 32; 103-106
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Issues of Reactive Power Compensation in High-voltage Transmission Lines
Problematyka kompensacji mocy biernej linii elektroenergetycznych wysokiego napięcia
Autorzy:
Lubośny, Z.
Klucznik, J.
Dobrzyński, K.
Powiązania:
https://bibliotekanauki.pl/articles/397065.pdf
Data publikacji:
2015
Wydawca:
ENERGA
Tematy:
reactive power compensation
overhead lines
shunt reactor
kompensacja mocy biernej
linia napowietrzna
dławik bocznikowy
Opis:
This paper discusses the selection of compensation shunt reactors for a double-circuit 400 kV transmission line using the example of the newly built Elk Bis – Alytus transmission line. The analysis takes into account various conditions of the power system. The published results relate to voltage levels in steady states and during switching processes and short circuits.
W artykule przedstawiono rozważania dotyczące doboru dławików kompensacyjnych dla linii elektroenergetycznej dwutorowej wysokiego napięcia 400 kV, na przykładzie nowo budowanej linii Ełk Bis – Alytus. W analizach uwzględniono różne stany pracy układu. Zamieszczone wyniki dotyczą poziomów napięć w stanach ustalonych, podczas procesów łączeniowych oraz zwarć.
Źródło:
Acta Energetica; 2015, 2; 102-113
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies