Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "physicochemical and structural evaluation" wg kryterium: Wszystkie pola


Wyświetlanie 1-3 z 3
Tytuł:
Characterization of amino-, epoxy- and carbonyl-functionalized halloysite and its application in the immobilization of aminoacylase from Aspergillus melleus
Autorzy:
Kołodziejczak-Radzimska, Agnieszka
Jesionowski, Teofil
Powiązania:
https://bibliotekanauki.pl/articles/110662.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
functionalized halloysite
physicochemical and structural evaluation
immobilization
thermal and chemical stability
reusability
Opis:
Functionalized halloysite was used as a support for the immobilization of an enzyme. The surface of halloysite was modified with amino (–NH), epoxy (–C(O)C) and carbonyl (–C=O) groups. Both unmodified and modified forms of the support underwent a comprehensive physicochemical and structural evaluation, including morphological, structural, thermogravimetric and spectroscopic analysis. Aminoacylase from Aspergillus melleus was used as the enzyme in the immobilization process. The process of immobilization by adsorption was performed for 1, 6 and 24 h using different concentrations of enzyme solution (0.5, 1 and 3 mg/cm3). The quantity of aminoacylase loaded onto the support was calculated by the Bradford method. Free and immobilized aminoacylase were used to catalyze the deacetylation of N-acetyl-L-methionine. Additionally, the thermal and chemical stability of the obtained biocatalytic systems were evaluated, as well as the reusability of the immobilized systems. The biocatalytic system with amino groups demonstrated activity above 70% in the pH range 4–9 and 60% in the temperature range 30–70 °C. Aminoacylase immobilized on amino-functionalized halloysite also retains around 50% of its initial activity after five reaction cycles.
Źródło:
Physicochemical Problems of Mineral Processing; 2019, 55, 1; 128-139
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the differentiation of structural and physicochemical properties of orthodontic wires of AlSl 304 stainless steel
Autorzy:
Grygier, D.
Hoppe, V.
Zięty, A.
Rutkowska-Gorczyca, M.
Powiązania:
https://bibliotekanauki.pl/articles/284388.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
wires
orthodontic arches
physicochemical properties
Źródło:
Engineering of Biomaterials; 2018, 21, 148; 14
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the differentiation of structural and physicochemical properties of orthodontic wires of AISI 304 stainless steel
Autorzy:
Grygier, D.
Hoppe, V.
Zięty, A.
Rutkowska-Gorczyca, M.
Powiązania:
https://bibliotekanauki.pl/articles/284164.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stainless steel
orthodontics wire
microstructure
Opis:
Wires used for orthodontic arches play a very important role in the process of orthodontic treatment. In combination with the lock attached to the tooth, they move and align the teeth along the set trajectories. Wires of stainless steel are commonly used in orthodontics for several reasons: they are characterised by high resistance to corrosion, high strength and elasticity, formability and a possibility of obtaining defined properties through cold working and annealing during production process. The purpose of the research presented in the work is the analysis of differences of the selected structural properties in the context of corrosion resistance of the orthodontic wire material. The object of the research was edge arches of the 0.016”x0.022” size made of the stainless steel type AISI 304, provided by two different producers: G&H Orthodontics and Adenta. The research methodology involved analysis of chemical and phase composition of the tested alloy, microscopic tests with application of the light and electron microscopy methods, as well as electrochemical direct current measurements. The research presented in the work has shown significant differences in structural and physical-chemical properties of the orthodontic wires made of AISI 304 type stainless steel. Despite the fact, that the tested arches were manufactured of the theoretically the same materials, but by different producers, they significantly differ in chemical composition, metallurgical purity, phase composition and corrosion resistance. In addition, it is worth noticing that the tested materials, in terms of structure, do not meet the normative requirements obligatory for biomaterials.
Źródło:
Engineering of Biomaterials; 2018, 21, 146; 8-13
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies