Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "bone implants" wg kryterium: Wszystkie pola


Tytuł:
Potential activation of the immune system on metallic materials for bone implants
Autorzy:
Stranavova, L.
Bacakova, M.
Novotna, K.
Bacakova, L.
Fencl, J.
Powiązania:
https://bibliotekanauki.pl/articles/285314.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
bone implants
metallic materials
biomaterials
Opis:
Titanium and stainless steel are metallic materials that have been in use for a long time in orthopedics, traumatology and stomatology. These metals are strong, corrosion-resistant and biocompatible. However, metallic materials have some disadvantages in comparison with the natural bone, particularly their relatively high specific weight and toughness. For example, the Young's modulus of AISI316L stainless steel, Co-Cr alloys and Ti-6Al-4V alloy, i.e. materials frequently used for implantation into bone, ranges between 110-220 GPa, while the Young's modulus of bone tissue is 10-40 GPa [1]. In addition, these metals can release cytotoxic, allergenic and immunogenic ions, which can affect their biocompatibility [2, 3]. Implantation is a special type of transplantation process, in which the implant is inserted into the body, usually in order to replace an irreversibly damaged tissue. However, the immune system recognizes the implant as a foreign substance and attacks it with its effector mechanisms. Just as it can reject other types of transplants, the immune system can reject an artificial implant. To prevent rejection of an implant, it is important to study the potential activation of the immune system. This study has investigated the biocompatibility of samples made of pure titanium (according to quality standard ISO 5832-2) and corrosion-resistant steel (quality standards ISO 5832-1 and AISI 316L), obtained from Beznoska Ltd. (Kladno, Czech Republic), and the potential activation of the immune system by these materials. In addition to Fe, the steel samples contained C (max. 0.025 wt.%), Si (0.6 wt.%), Mn (1.7 wt.%), P (max. 0.025wt.%), S (max. 0.003 wt.%), Cr (17.5 wt.%), Ni (13.5 wt.%), Mo (2.8 wt.%), and Cu (max. 0.1 wt. %). The materials were used in the form of square samples (9x9 mm or 30x30 mm, thick¬ness 1 mm). Both the Ti samples and the steel samples were ground with SiO2. The surface of the steel samples was then treated by polishing with Al2O3 paste (grain size up to 1 um), while the surface of the Ti samples, i.e. a material not suitable for polishing, was finished by brushing using another type of Al2O3 paste with slightly larger grains. Thus, the surface of the steel samples was finally smoother and glossy, while the Ti surface was rougher and matte. For the in vitro biocompatibility tests, human osteoblast-like MG 63 cells (European Collection of Cell Cultures, Salisbury, UK) were used. The smaller samples (9x9 mm) were inserted into polystyrene 24-well cell culture plates (TPP, Trasadingen, Switzerland; well diameter 1.5 cm). Each well contained 25 000 cells (approx. 14 150 cells/cm2) and 1.5 ml of Dulbecco's Modified Eagle Minimum Essential Medium (DMEM; Sigma, USA, Cat. No. 10270-106) supplemented with 10% foetal bovine serum (FBS; Gibco, Cat. No. 10270-106) and gentamicin (40 /jg/ml, LEK, Slovenia). These samples were used for evaluating the size of the cell spreading area (day 1), and for evaluating cell shape and cell viability (days 1, 4 and 7 after seeding). The size of the cell spreading area was measured using Atlas Software (Tescan Ltd., Brno, Czech Republic). The viability of the cells was determined by the LIVE/ DEAD viability/cytotoxicity kit for mammalian cells (Invitrogen, Molecular Probes, USA). The larger samples (30x30 mm) were inserted into GAMA polystyrene dishes (diameter 5 cm; GAMA Group Joint-Stock Company, Ceske Budejovice, Czech Republic) and seeded with 300 000 cells/dish (approx. 15 300 cells/cm2) suspended in 9 ml of the above mentioned culture medium. These samples were used for evaluating the cell number on days 1, 4 and 7 after seeding, using a Beckman Vi-CELL XR Cell Analyser automatic cell counter. For the in vitro analysis of markers of osteogenic differentiation and cell immune activation, human osteoblast-like MG 63 cells (European Collection of Cell Cultures, Salisbury, UK) were used. The samples (9x9 mm) were inserted into polystyrene 24-well cell culture plates (TPP, Trasadingen, Switzerland; well diameter 1.5 cm). Each well contained 25 000 cells (approx. 14 150 cells/cm2) and 1.5 ml of Dulbecco's Modified Eagle Minimum Essential Medium (DMEM; Sigma, USA, Cat. No. 10270-106) supplemented with 10% foetal bovine serum (FBS; Gibco, Cat. No. 10270-106) and gentamicin (40 jg/ml, LEK, Slovenia). The cells were cultured for 1, 4, or 7 days at 37°C in a humidified atmosphere of 5% of CO2 in the air. On day 4 after seeding, the medium was changed; one half of the samples contained standard medium DMEM with 10% foetal bovine serum and gentamicin (40 jg/ml) mentioned above, and the second half contained osteogenic medium, i.e. the standard medium further supplemented with ß-glycerophosphate, L-glutamin, ascorbic acid, dihydroxyvitamin D3, dexamethason, 10% foetal bovine serum and gentamicin (40 jg/ml). Using an Enzyme-Linked ImmunoSorbent Assay (ELISA), we measured the concentration of the Inter¬cellular Adhesion Molecule-1 (ICAM-1, a marker of cell immune activation) and osteocalcin (a marker of osteogenic cell differentiation). These measurements were performed in homogenates of cells on days 4 and 7 after seeding, and the concentration of both markers was measured per cell or per mg of protein. On day 7, the amount of osteocalcin was measured and compared in cells cultured in the standard and osteogenic media. We also measured TNF-а and IL- 1ß, i.e. other markers of cell immune activation. These cytokines are important mediators of the inflammatory response, and they are involved in a variety of cellular activities, including cell proliferation and differentiation. We measured the secretion of these markers into the cell culture medium in murine macrophage-like RAW264.7 cells (American Type Culture Collection, Manassas, VA). The samples (9x9 mm) were inserted into polystyrene 24-well cell culture plates (TPP, Tra- sadingen, Switzerland; well diameter 1.5 cm). Each well contained 30,000 (approx. 16 980 cells/cm2) cells and 1.5 ml of the culture medium. RAW 264.7 cells were cultured in the RPMI-1640 medium (Sigma; 10% fetal bovine serum, 40 jg/mL gentamicin). After 7 days of cultivation, the cell culture medium was collected and used for measuring the concentration of TNF-а and IL-1ß by a sandwich ELISA using commercially available kits. A mouse TNF-а kit and an IL- 1ß Quantikine ELISA kit were used for the RAW 264.7 cells. Both kits were purchased from R and D Systems (Minneapolis, MN) and used according to the manufacturer's protocol. The results indicated that the number of initially adhering MG 63 cells on day 1 after seeding was significantly lower on the titanium (5320±390 cells/cm2) and on the stainless steel (4110±370 cells/cm2) than on the control polystyrene culture dishes (7740±350 cells/cm2). However, on day 4 after seeding, the cell population density on both metallic materials became significantly higher than on the control polystyrene dishes (75200±2890 cells/cm2 on Ti and 90 870±2350 cells/cm2 on steel vs. 56440±1180 cells/cm2 on polystyrene). This suggests faster cell proliferation on both metallic materials than on polystyrene. At the same time, the cell number on the stainless steel samples was significantly higher than on the Ti samples. On day 7, the differences in the number of adhered cells on the two metals and on the control polystyrene substrate was on an average similar (from 328780±680 cells/cm2 to 362200±760 cells/cm2). The cell viability on all tested materials was almost 100% in all culture intervals. The morphology of the cells adhered on the studied materials was similar to the morphology of the cells on the control polystyrene dishes, i.e. the cells were mostly flat and polygonal, and the size of their cell spreading areas was similar on all tested materials. The cells were distributed homogeneously on the entire material surface, and on day 4 they started to form confluent cell layers. On day 4, we measured the amount of ICAM-1 by the ELISA test. This immunoglobulin molecule is typically expressed on cells of the immune system, but it is also expressed on other cell types, including MG 63, during their immune activation, e.g. by an artificial growth support. In this case, ICAM-1 molecules on cells are bound byß2-integrin receptors on inflammatory cells (for a review, see [4]). Surprisingly, titanium seemed to be more immunogenic than stainless steel, which was indicated by a higher concentration of ICAM-1 per cell and mg of protein in cells on day 4 after seeding. However, on day 7, there was no difference between the concentrations of ICAM-1 per cell and mg of protein in cells on titanium and on stainless steel. The second molecule that we measured was osteocalcin, a calcium-binding extracellular matrix glycoprotein, an important marker of the bone formation process. The concentration of osteocalcin on day 4 in the standard culture medium was higher in MG 63 cells on the titanium and stainless steel than on the control polystyrene samples. This could be explained by the fact that the metals are harder than polystyrene. It is known that harder substrates promote osteogenic cell differentiation, while softer substrates direct the cell differentiation towards neural or muscle phenotype [5]. In addition, the osteogenic differentiation was further supported by the osteogenic medium, as indicated by a higher concentration of osteocalcin in cells grown in this medium compared to cells in the standard medium on day 7 after seeding. On day 7 after seeding murine macrophage-like RAW264.7 cells on the tested materials, the concentration of TNF-а in the culture medium ranged on an average from 57.10 to 79.39 pg per 2000000 cells. The concentration of TNF-а in the medium from Ti and Fe was significantly higher than in the medium from the control polystyrene dishes. The highest value (79.39 pg/2000000 cells) was found in the medium taken from RAW264.7 cells on Ti. The second molecule that we tested was IL-1ß. No significant differences in the concentration of IL-1ß were detected in the culture medium obtained from RAW264.7 cells on all tested materials. In other words, neither type of metallic material, i.e. Ti and Fe, evoked significantly higher production of IL-1ß by RAW 264.7 cells than standard polystyrene cell culture dishes. It can be concluded that the tests of biocompatibility and immune activation confirmed that titanium and stainless are promising for construction of bone implants and for good integration with the surrounding bone tissue.
Źródło:
Engineering of Biomaterials; 2012, 15, no. 116-117 spec. iss.; 130-131
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wielofunkcyjne biopolimerowe skafoldy jako implanty kości
Multifunctional biopolymeric scaffolds for bone implants
Autorzy:
Mucha, M.
Tylman, M.
Powiązania:
https://bibliotekanauki.pl/articles/284784.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
skafoldy polimerowe
inżynieria tkankowa
chitozan
polilaktyd
polymer scaffolds
tissue engineering
chitosan
polylactide
Opis:
W prezentowanej pracy przedstawiono metodykę otrzymywania wielofunkcyjnych skafoldów biopolimerowych (chitozan, polilaktyd) do zastosowań w inżynierii tkanki kostnej. Skafoldy biopolimerowe z udziałem hydroksyapatytu wytworzono trzema metodami: elektrolityczną, liofilizacyjną oraz wypukiwania soli. Zbadano ich właściwości morfologiczne, przeprowadzono badania mikroskopowe powierzchni pod mikroskopem optycznym oraz elektronowym. Zbadano kinetykę kontrolowanego uwalniania kolagenu, który w skafoldach pełni funkcję odżywczą komórek, a także poprawia ich adhezję na powierzchni skafoldu. Kinetyka kontrolowanego uwalniania została opisana funkcją I rzędu oraz dwuetapowym modelem Corrigana-Gallaghera. Przedstawiono możliwości modyfikacji powierzchniowej skafoldów otrzymanych metodą elektrolityczną za pomocą nanosrebra.
The paper presents a methodology of multifunctional biopolymeric (chitosan, polylactic acid) scaffolds preparation for use in bone tissue engineering. Biopolymeric scaffolds with hydroxyapatite were prepared by three methods: electrolytic, freezedrying, and salt leaching. Their morphological properties, using optical and electron microscope were studied. Controlled release kinetics of collagen was also investigated. Collagen has nutritional function for cells and improves their adhesion on the scaffold surface. Kinetics of controlled release was described by first order function and two-stage Corrigan-Gallagher model. The possibilities of surface modification of scaffolds produced by electrolitic method with nanosilver were presented.
Źródło:
Engineering of Biomaterials; 2013, 16, 118; 12-17
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the surface condition of removed bone implants
Analiza stanu powierzchni usuniętych implantów kostnych
Autorzy:
Mierzejewska, Ż. A.
Kuptel, P.
Sidun, J.
Powiązania:
https://bibliotekanauki.pl/articles/1365832.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
implant
surface analysis
operating wear
tribological wear
analiza powierzchni
zużycie eksploatacyjne
zużycie tribologiczne
Opis:
The requirements that must be met by implant materials are rigorous and diverse. These materials are tasked with supporting or replacing sick or damaged parts of the musculoskeletal system, where loads and a heterogeneous stress state frequently occur. Thus, they must have the appropriate strength properties and resistance to many types of corrosion, which is related to biotolerance, or neutrality of the material to the human body during use. This article presents the results of studies of three implant groups: set for stabilization of long bones made of 316L austenitic steel, set for intramedullary nail insertion in grafts of femur bones made of Ti6Al4V titanium alloy, and a straighty reconstruction plate made of Ti6Al4V titanium alloy coated with an oxide layer. These implants were implanted into the human body and then removed at the end of the treatment process or due to implant failure during its operation. Next, implants were studied in order to determine the level of wear. Investigations were carried out using an Hitachi S-3000N scanning microscope. Their results indicate a series of changes that took place on implant surfaces and confirm the existence of typical implant wear mechanisms presented in reports in the literature. Traces of corrosion, fatigue cracks, tribological wear, and traces of fretting were found on examined implant surfaces. The study of implant wear cases, determination of their character, and evaluation of the intensity of destructive processes may contribute to the improvement of both the mechanical properties of these implants and their shape, so that modern bone implants perform their roles without the risk of failure during their operation.
Wymagania stawiane materiałom na implanty są wysokie i bardzo zróżnicowane. Mają one wspomagać lub zastępować chore lub uszkodzone części układu kostno-mięśniowego, gdzie często pojawiają się obciążenia i różnorodny stan naprężeń. Muszą zatem charakteryzować się odpowiednimi własnościami wytrzymałościowymi i odpornością na różne rodzaje korozji, powiązaną z biotolerancją oznaczającą neutralność materiału wobec organizmu podczas użytkowania. W pracy przedstawiono wyniki badań trzech grup implantów: zestawu do stabilizacji kości długich, wykonanego ze stali austenitycznej 316L, zestawu do gwoździowania śródszpikowego do zespoleń złamań kości udowej, wykonanego ze stopu tytanu Ti6Al4V oraz płytki rekonstrukcyjnej prostej, wykonanej ze stopu tytanu Ti6Al4V pokrytego warstwą tlenków. Implanty te wszczepione były do organizmu ludzkiego, a następnie usunięte, wraz z zakończeniem procesu leczenia lub wskutek uszkodzenia implantu podczas jego eksploatacji. Następnie poddano je badaniom w celu określenia stopnia zużycia. Badania realizowano z wykorzystaniem mikroskopu skaningowego Hitachi S-3000N. Wyniki badań wskazują na szereg zmian, które zaszły na powierzchni implantów i potwierdziły istnienie typowych mechanizmów zużycia implantów prezentowanych w doniesieniach literaturowych. Na powierzchni badanych implantów zauważono ślady korozji, pęknięcia zmęczeniowe, zużycie tribologiczne oraz ślady frettingu. Badania zużycia implantów, określenie ich charakteru oraz ocena intensywności zachodzenia procesów niszczenia mogą w przyszłości znacznie wpłynąć na poprawę zarówno właściwości mechanicznych tych implantów, jak również na próbę zmiany ich kształtu tak, by nowoczesne implanty kostne spełniały swoją rolę bez ryzyka zniszczenia w trakcie ich eksploatacji.
Źródło:
Eksploatacja i Niezawodność; 2016, 18, 1; 65-72
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Influence of Mechanical, and Material Factors on the Biological Adaptation Processes of the Femoral Bone Implants
Autorzy:
Jasik, A.
Mroczek, M.
Powiązania:
https://bibliotekanauki.pl/articles/351931.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
orthopedic implants
stress
Finite Element Method (FEM)
Opis:
The study covers some aspects of the issue of determination of mutual connections between the mechanical and material factors, as well the biological implant adaptation processes. The main objective of the operation was adopted to develop models of cementless hip prosthesis company Fitmore Zimmer, taking into account the heterogeneity of material properties of bone tissue. These models were loaded in particular stages of the human gate and then they were used for the analysis of stress changes. The identification of the relations between the mechanical properties of osseous tissue required the conducting of computer simulations by means of the Finite Element Method (FEM).
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 1; 189-194
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bioactivity of cement type bone substitutes
Autorzy:
Siek, D.
Czechowska, J.
Mróz, W.
Zima, A.
Burdyńska, S.
Załęczny, R.
Ślósarczyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/200610.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
bone implants
bioactivity
surface morphology
Opis:
In vitro chemical stability and bioactivity of three different cement type bone substitutes were determined by incubating cement samples in the simulated body fluid (SBF) for 7 and 28 days. Morphology of sample surfaces has been studied using scanning electron microscopy (SEM) combined with an energy dispersive X-ray spectroscopy (EDS) and by atomic force microscopy (AFM). The diffuse reflectance Fourier-transform infrared spectroscopy (DRIFTS) was applied as a supplementary method. The development of bone-like apatite layers on the surface depended on their initial phase composition. Obtained cements showed good surgical handiness, high bioactive potential and were chemically stable. They seem to be promising materials for bone substitution.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 2; 433-439
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kompozyt polimerowo-ceramiczny jako potencjalny implant kostny
Polymer-ceramic composite as a potential bone implant
Autorzy:
Jelonek, A.
Kilan, K.
Skórska-Stania, A.
Oleksyn, B.
Powiązania:
https://bibliotekanauki.pl/articles/284768.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
composites
bone implants
polymers
kompozyty
implanty kostne
polimery
Źródło:
Engineering of Biomaterials; 2010, 13, no. 99-101; 125-127
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Adhesion and growth of human osteoblast-like MG 63 cells on titanium and stainless steel samples developed for constructing bone implants
Autorzy:
Stranavova, L.
Bacakova, M.
Bacakova, L.
Fencl, J.
Powiązania:
https://bibliotekanauki.pl/articles/284428.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
osteoblasts
biomaterials
implants
Opis:
Titanium and stainless steel are strong, corrosion - resistant and biocompatible metals. Thanks to their remarkable properties, they have been in use for a long time in clinical medicine, mainly for constructing and replacing large joints, in particular the bone-anchoring parts, e.g. cups and stems, and also for fabricating orthopaedic screws and splints. In the Czech Republic, these devices are produced by Beznoska Ltd., and are clinically applied in the Orthopaedic Clinic, Bulovka Faculty Hospital in Prague. This study has investigated the biocompatibility of samples made of pure titanium (according to quality standard ISO 5832-2 ) and corrosion-resistant steel (quality standards ISO 5832-1 and AISI 316L), obtained from Beznoska. In addition to Fe, the steel samples contained C (max. 0.025 wt. %), Si (0.6 wt. %), Mn (1.7 wt. %), P( max. 0.025 wt. %), S(max. 0.003 wt. %), Cr (17.5 wt. %), Ni (13.5 wt. %), Mo (2.8 wt. %), and Cu (max. 0.1 wt. %). The materials were used in the form of square samples (9x9 mm or 30x30 mm, thickness 1 mm ). Both Ti and steel samples were grinded with SiO2. The surface of the steel samples was then treated by polishing with Al2O3 paste (grain size up to 1 μm), while the surface of the Ti samples, i.e. a material not suitable for polishing, was finished by brushing using another type of Al2O3 paste with slightly larger grains. Thus, the surface of the steel samples was finally smoother and glossy, while the Ti surface was rougher and matted. For the in vitro biocompatibility tests, human osteoblast-like MG 63 cells (European Collection of Cell Cultures, Salisbury, UK) were used. The smaller samples (9 x 9 mm) were inserted into polystyrene 2 4-well cell culture plates (TPP, Trasadingen, Switzerland; well diameter 1.5 cm). Each well contained 25000 cells (approx. 14150 cells / cm 2 ) and 1.5 ml of Dulbecco’s Modified Eagle Minimum Essential Medium (DMEM; Sigma, USA, Cat. No. 10270-106) supplemented with 10 % foetal bovine serum (FBS; Gibco, Cat. No. 10270-106) and gentamicin (40 μg/ml, LEK, Slovenia). These samples were used for evaluating the size of the cell spreading area (day 1), and for evaluating cell shape and cell viability (days 1, 4 and 7 after seeding). The size o f the cell spreading area was measured using Atlas Software (Tescan Ltd., Brno, Czech Republic). The viability of the cells was determined by the LIVE/DEAD viability cytotoxicity kit for mammalian cells (Invitrogen, Molecular Probes, USA). The larger samples (30x30 mm) were inserted into GAMA polystyrene dishes (diameter 5 cm; GAMA Group Joint- Stock Company, Ceske Budejovice, Czech Republic) and seeded with 300000 cells/dish (approx. 15300 cells/cm 2) suspended in 9 ml of the above mentioned culture medium. These samples were used for evaluating the cell number on days 1, 4 and 7 after seeding, using a Beckman Vi- CELL XR Cell Analyser automatic cell counter. The results indicated that the number of initially adhering cells on day 1 after seeding was significantly lower on the titanium (5320±390 cells/cm2) and on the stainless steel ( 4110±370 cells/cm 2) than on the control polystyrene culture dishes (7740±350 cells/cm2). However, on day 4 after seeding, the cell population density on both metallic materials studied here became significantly higher than on the control polystyrene dishes (75200±2 890 cells/cm2 on Ti and 90870 ±2350 cells/cm2 on steel vs. 56440±1180 cells/cm2 on polystrene). This suggests faster cell proliferation on both metallic materials than on polystyrene. At the same time, the cell number on the stainless steel samples was significantly higher than on the Ti samples. On day 7, the differences in number of adhered cells on both studied metals and on the control polystyrene substrate was on an average similar (from 328780±680 cells/cm2 to 362200 ±760 cells/cm2). The cell viability on all tested materials was almost 100 % in all culture intervals. The morphology of the cells on the studied materials was similar to the morphology of the adhered cells on the control polystyrene dishes, i.e. the cells were mostly flat and polygonal, and the size of their cell spreading areas w as similar on all tested materials. The cells were distributed homogeneously on the entire material surface, and on day 4 they started to form confluent cell layers (FIG. (1). It can be concluded that the tests of biocompatibility confirmed that the titanium and the stainless steel promoted the adhesion and growth of bone - derived cells, and thus these materials are promising for construction of bone implants and for their good integration with the surrounding bone tissue. Further studies on osteogenic cell differentiation, potential immune activation and the response of the bone cells to growth factors, including bone morphogenetic protein, are in progress.
Źródło:
Engineering of Biomaterials; 2011, 14, no. 109-111 spec. iss.; 10-11
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study on mechanical aspects of the structural modification of ε-polycaprolactone with the wollastonite nanoparticles
Autorzy:
Podporska, J.
Sołtysiak, E.
Błażewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/284170.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
polymer nanocomposites
nanowollastonite
bone implants
composite processing
mechanical properties
bioactivity
Opis:
Following the request for novel composite biomaterials for bone tissue engineering, nanocomposites consisted of ε-polycaprolactone and wollastonite, were prepared. Primary mechanical properties were examined and it was shown that the presence of wollastonite nano-particles affects significantly the Young’s modulus, tensile strength, fracture stress and work-of-fracture of the polymer matrix.
Źródło:
Engineering of Biomaterials; 2008, 11, 76; 17-19
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Antibacterial Composite Layers on Ti: Role of ZnO Nanoparticles
Autorzy:
Roguska, A.
Belcarz, A.
Suchecki, P.
Andrzejczuk, M.
Lewandowska, M.
Powiązania:
https://bibliotekanauki.pl/articles/354849.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
bone implants
TiO2 nanotubes
ZnO nanoparticles
Staphylococcus epidermidis
antibacterial properties
Opis:
Problem of Post-operative infections of implant materials caused by bacterial adhesion to their surfaces is very serious. Enhancement of antibacterial properties is potentially beneficial for biomaterials value. Therefore, the metallic and metallic oxide nanoparticles attract particular attention as antimicrobial factors. The aim of this work was to create nanotubular (NT) oxide layers on Ti with the addition of ZnO nanoparticles, designed for antibacterial biomedical coatings. Antimicrobial activities of titanium, TiO2 NT and ZnO/TiO2 NT surfaces were evaluated against bacterial strain typical for orthopaedic infections: S. epidermidis. TiO2 NT alone killed the free bacterial cells significantly but promoted their adhesion to the surfaces. The presence of moderate amount of ZnO nanoparticles significantly reduced the S. epidermidis cells adhesion and viability of bacterial cells in contact with modified surfaces. However, higher amount of loaded nanoZnO showed the reduced antimicrobial properties than the medium amount, suggesting the overdose effect.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 1; 213-216
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Antibacterial Composite Layers on Ti: Role of ZnO Nanoparticles
Autorzy:
Roguska, A.
Belcarz, A.
Suchecki, P.
Andrzejczuk, M.
Lewandowska, M.
Powiązania:
https://bibliotekanauki.pl/articles/355309.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
bone implants
TiO2 nanotubes
ZnO nanoparticles
Staphylococcus epidermidis
antibacterial properties
Opis:
Problem of post-operative infections of implant materials caused by bacterial adhesion to their surfaces is very serious. Enhancement of antibacterial properties is potentially beneficial for biomaterials value. Therefore, the metallic and metallic oxide nanoparticles attract particular attention as antimicrobial factors. The aim of this work was to create nanotubular (NT) oxide layers on Ti with the addition of ZnO nanoparticles, designed for antibacterial biomedical coatings. Antimicrobial activities of titanium, TiO2 NT and ZnO/TiO2 NT surfaces were evaluated against bacterial strain typical for orthopaedic infections: S. epidermidis. TiO2 NT alone killed the free bacterial cells significantly but promoted their adhesion to the surfaces. The presence of moderate amount of ZnO nanoparticles significantly reduced the S. epidermidis cells adhesion and viability of bacterial cells in contact with modified surfaces. However, higher amount of loaded nanoZnO showed the reduced antimicrobial properties than the medium amount, suggesting the overdose effect.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 2B; 937-940
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bioszkła i organiczno-nieorganiczne kompozyty dla inżynierii tkankowej kości
Bioglasses and organic-inorganic composites for bone tissue engineering
Autorzy:
John, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/172492.pdf
Data publikacji:
2012
Wydawca:
Polskie Towarzystwo Chemiczne
Tematy:
biomateriały
bioszkło
organiczno-nieorganiczne hybrydy
hydroksyapatyt
implanty kości
in vitro
biomaterials
bioglasses
organic-inorganic hybrid
hydroxyapatite
bone implants
Opis:
The most demanded biomaterials for bone tissue engineering could be classified in two main sol-gel derived groups: bioglasses and organic-inorganic composites. The first of these include bioactive ceramics such as calcium phosphates (Tab. 2) [1], glasses and glass ceramics [2], and so-called inert ceramics (Tab. 1) such as Al2O3, zirconium and titanium dioxide, and carbon-based materials [3, 4]. Second-group of compounds constitute bioactive organic-inorganic hybrids, generally based on organic matrix and various inorganic dopants. Biomaterials in contact with human plasma and bone stem cells form, on their surface, hydroxyapatite Ca10(PO4)6(OH)2 (HAp) and its derivatives (Tab. 2). HAp-layer initiates bone growth and reconstruction of treated fragment (Fig. 2). These materials, due to the high degree of biocompability are considered as the most valuable compounds for bone surgery [5]. Extremely rapid development of biomaterials used in medicine caused the production of implants with different properties (Scheme 1). The real revolution and technological progress have brought biomimetic composites that mimic naturally occurring solutions in living organisms. The role of such implants is not only replacing the damaged parts of body, but – due to the appropriate morphology and composition – stimulating the growth of living cells (Fig. 3) and final bone regeneration. This article is devoted to this type of biomaterials proposed for bone tissue engineering.
Źródło:
Wiadomości Chemiczne; 2012, 66, 1-2; 21-39
0043-5104
2300-0295
Pojawia się w:
Wiadomości Chemiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowania stopu Ti6Al4V w inżynierii tkanki kostnej
Application of Ti6Al4V for tissue engineering
Autorzy:
Kucharski, R.
Bach, F. W.
Błażewicz, S.
Chłopek, J.
Bormann, D.
Powiązania:
https://bibliotekanauki.pl/articles/285290.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stop tytanu
implanty kostne
inżynieria tkankowa
otwarte struktury metaliczne
proces spiekania
titanium alloys
bone implants
tissue engineering
open pored metallic structures
sintering process
Opis:
Główną wadą implantów na bazie stopów tytanu przeznaczonych dla chirurgii kostnej, wymagających długoczasowej stabilności, jest niedopasowanie struktury powierzchni implantu do otaczającej tkanki. Przy implantach stawu biodrowego może to prowadzić do aseptycznego obluzowania się endoprotezy. Funkcjonalne dopasowanie implantu jako otwarto-porowatej struktury, która obejmuje cały implant lub tylko powierzchnię, może sprzyjać procesowi wzrostu tkanki kostnej w pory implantu lub prowadzić do jego mechanicznego zakotwiczenia. W pracy przedstawiono wyniki badań nad spiekaniem proszków Ti-6Al-4V o wielkości ziaren 35mim. Proces spiekania prowadzono w gradiencie temperatury w atmosferze gazu obojętnego. Metoda ta pozwalała otrzymywać mikrostruktury o otwartych porach, które mogą być wykorzystane do konstrukcji implantów ze stopów tytanu o podwyższonej trwałości i zdolności do fiksacji z tkanką kostną.
The main reasons for the failure of titanium based alloy bone implants requiring long term stability is the incompatibility of the implant's surface structure and the growth rate of natural bone tissue. In the case of a hip joint endoprosthesis, this leads to an aseptic loosening of the endoprosthesis. Functional adaptation of the implant as an open pored structure, which either extends over the whole implant or exists only on its surface, presents the possibility for the bone tissue to grow into the implant and provide mechanical anchorage for the implant in the bone. In the present work, the results of investigations and the sintering process using 35mim size powder grains of the alloy Ti-6Al-4V are presented. A sintering process was chosen as a manufacturing method using a selected temperature gradient and an inert scavenging gas. This method of manufacture produced open pored structures whose properties can be transferred to a larger group of applications of metallic long term implants for osteosynthesis.
Źródło:
Engineering of Biomaterials; 2007, 10, no. 69-72; 18-22
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Solution blow spun poly-L-lactic acid/ceramic fibrous composites for bone implant applications
Autorzy:
Wojasiński, Michał
Ciach, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2086798.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
solution blow spinning
composite fibres
submicron fibres
nanofibres
poly-L-lactic acid
ceramic particles
bone implants
wirowanie z rozdmuchiwaniem roztworu
włókna kompozytowe
włókna submikronowe
nanowłókna
kwas poli-L-mlekowy
cząstki ceramiczne
implanty kostne
Opis:
Every bone implant to work correctly after implantation needs to integrate with the surrounding bone. To enhance such a process, called osseointegration, various techniques of implant surface modification emerged. One of the approaches is based on the deposition of nano- and submicron materials on the implant surface. This paper presents a solution blow spinning process for producing poly-L-lactic acid (PLLA)/ceramic fibrous composites designed to be deposited directly onto orthopaedic implants prior to implantation to increase osseointegration. We produced plain PLLA fibrous materials for comparison, and fibrous composite materials with -tricalcium phosphate (TCP), hydroxyapatite nanoparticles (nHAp) and hydroxyapatite nanoparticles modified with lecithin (nHAp-LE). We performed the structural analysis of produced materials with scanning electron microscopy, gravimetric determination of porosity, and water contact angle measurement. We also used infrared spectroscopy, Alizarin Red S staining, and cytotoxicity evaluation to conclude that PLLA/nHAp-LE composite material shows the most promising properties to be applied as surface modification of bone implants. To visualise fibrous composite deposition on implants, we used two models: titanium plate and stainlesssteel bolt. Thus, we showed that the solution blow spun materials can be used for surface modification of orthopaedic implants.
Źródło:
Chemical and Process Engineering; 2021, 42, 3; 275--289
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Surface Modification Of Implants For Bone Surgery
Modyfikacja powierzchni implantów ortopedycznych
Autorzy:
Marciniak, J.
Szewczenko, J.
Kajzer, W.
Powiązania:
https://bibliotekanauki.pl/articles/355874.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
AISI 316L stainless steel
Titanium alloy Ti6Al4V
surface layer
corrosion and wear resistance
biocompatibility
stal nierdzewna AISI 316L
stop tytanu Ti-6Al-4V
warstwa powierzchniowa
korozja i odporność na ścieranie
biokompatybilność
Opis:
The study discusses the methods of surface modification methods for AISAI 316 L steel and Ti6Al4V ELI titanium alloy, dedicated to complex design implants used in bone surgery. Results of structural tests have been presented along with those evaluating the physicochemical properties of the formed surface layers. Clinical feasibility of the surface layers has also been evaluated. The developed surface modification methods improved the resistance to pitting, crevice and stress corrosion and ensured better biocompatibility. Moreover, the layers formed are marked by plasticity. Results of the tests performed show applicability of the evaluated methods of surface modification in complex shape implants for the clinical use.
W pracy omówiono metody modyfikacji powierzchni stali AISAI 316 L oraz stopu tytanu Ti6Al4V ELI przeznaczonych na implanty o złożonej konstrukcji stosowanych w chirurgii kostnej. Przedstawiono wyniki badań struktury oraz własności fizykochemicznych wytworzonych warstw wierzchnich. Określono również przydatność wytworzonych warstw do zastosowań klinicznych. Opracowane metody modyfikacji powierzchni zwiększyły odporność na korozję wżerową, szczelinową i naprężeniową oraz poprawiły biokompatybilności. Ponadto wytworzone warstwy cechują się podatnością do odkształceń. Wyniki badań wykazały przydatność zastosowanych metod modyfikowania powierzchni implantów o złożonych kształtach do zastosowań klinicznych.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 3; 2123-2129
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Role of initial density distribution in simulations of bone remodeling around dental implants
Autorzy:
Nutu, E.
Powiązania:
https://bibliotekanauki.pl/articles/307275.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
energia odkształcenia
kość
warunki początkowe
przebudowa kości
strain energy density
bone quantity
initial conditions
bone remodeling simulation
Opis:
In this paper, the effect of initial density distribution upon the predicted density via numerical simulations of bone remodeling was evaluated. The main purpose was to correlate the numerical results with clinical data according to which the initial bone quantity is an essential factor for long term survival of dental implants. Methods: Two-strain energy density-based bone remodeling theories were employed, one which accounts for overload resorption and the second one, which does not. The remodeling parameters were derived from the mechanostat theory. Bone remodeling around an osseointegrated dental implant was simulated based on finite element method using a generic mandible plane model. A variable time step was introduced to increase the speed of the remodeling simulations by keeping the truncation errors small. The simulations were performed for several initial density distributions correlated with values from clinical classifications of bone quality. For each density value, the occlusal load was defined in two ways so that to consider normal and overload mastication forces, respectively. Results: The results showed that the initial density distribution influences the predictions of bone remodeling simulations. For the analyzed model, the remodeling algorithm predicted overload resorption only in the case of low initial density, which can be associated with low bone quality, which, from clinical perspective, may probably lead to implant loss. Conclusions: The paper demonstrated that when simulating bone remodeling around dental implants using finite element method, it is important to account for initial density distribution in correlation with the bone quantity.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 4; 23-31
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies