Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "water pH" wg kryterium: Temat


Tytuł:
Phytoplankton succession in an artificial, periodically drained small water body
Autorzy:
Celewicz-Goldyn, S.
Dotka, A.
Powiązania:
https://bibliotekanauki.pl/articles/790551.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Przyrodniczy w Poznaniu
Tematy:
phytoplankton succession
small water body
Cyanoprokaryota
Chlorophyceae
Chlorococcales
Haematococcus pluvialis
Aphanothece elabens
pond
diatom
water pH
Opis:
This study was undertaken to monitor the course of a secondary succession of phytoplankton in temporary water bodies, based on a man-made periodically drained pond. Results of phycological analyses showed, that small Chlorophyceae from the order Chlorococcales predominated qualitatively throughout the study period. Chlorophyceae, e.g. stress-resistant Haematococcus pluvialis, developed best as the first algae (after the pond was re-filled). In the next stages of diatom succession (Ulnaria ulna) predominated quantitatively, followed by the longest period of Cyanobacteria (Aphanothece elabens) predominance, replaced again by Chlorophyceae (Tetraëdron minimum and Oocystis lacustris). Total abundance of algae, similarly as that of Cyanobacteria, were positively correlated with temperature and pH of water.
Źródło:
Steciana; 2014, 18, 4
1689-653X
Pojawia się w:
Steciana
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sezonowa migracja wody glebowej w okresie stagnacji wegetacyjnej i ocena jej przydatności do spożycia
Seasonal migration of soil water in the stagnation of vegetation period and evaluation of its suitability for consumption
Autorzy:
Widłak, M.
Łukawska, M.
Powiązania:
https://bibliotekanauki.pl/articles/357493.pdf
Data publikacji:
2014
Wydawca:
Politechnika Śląska
Tematy:
woda glebowa
ruch wody w glebie
makroelementy
wymywanie
pH wody
pH gleby
parametry wody pitnej
soil water
water movement in the soil
macroelement
leaching
pH of water
pH of soil
drinking water parameters
Opis:
Artykuł zawiera charakterystykę form wody glebowej z omówieniem roli wody gruntowej oraz procesu wymywania pierwiastków biogennych z gleby. W glebie i wodzie badanych rejonów oznaczono stężenia N-NO3-, P-PO43-, K+, Mg2+, Ca2+ oraz odczyn. Badane próbki gleby pobierane były jesienią 2012r. i wiosną 2013r., próbki wody wiosną 2013r., czyli w okresie stagnacji wegetacyjnej roślin. Wodę pobierano ze studni kopanych zlokalizowanych w bezpośrednim sąsiedztwie gruntów ornych ze źródeł zagospodarowanych i niezagospodarowanych. Na podstawie uzyskanych wyników wskazane jest rozszerzenie badań wody glebowej z ujęć użytkowych, w celu zapewnienia jakości wody przeznaczonej do spożycia przez ludzi.
The article contains the characteristics of the soil water forms and discussion of the groundwater role as well as leaching process of biogenic elements from the soil. In the soil and water of studied areas the concentrations of N-NO3-, P-PO43-, K+, Mg2+, Ca2+ and pH were determined. The tested soil samples were collected in the autumn of 2012. and in the spring of 2013., water samples in the spring of 2013., thus in a period of plants vegetative stagnation. Water was collected from dug wells located in the immediate vicinity of the arable land from the developed and undeveloped sources. On the basis of the results it is advisable to extend the study of soil water from usable water intakes in order to ensure the water quality intended for human consumption.
Źródło:
Archiwum Gospodarki Odpadami i Ochrony Środowiska; 2014, 16, 3; 25-32
1733-4381
Pojawia się w:
Archiwum Gospodarki Odpadami i Ochrony Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uszkodzenia powierzchni betonowych budowli hydrotechnicznych zbiornika retencyjnego Pokrzywnica
Autorzy:
Wira, J.
Małecki, Z. J.
Powiązania:
https://bibliotekanauki.pl/articles/407629.pdf
Data publikacji:
2009
Wydawca:
Instytut Badawczo-Rozwojowy Inżynierii Lądowej i Wodnej Euroexbud
Tematy:
zbiornik retencyjny
karbonatyzacja betonu
budowle wodne
korozja stali
odczyn pH wody
storage reservoir
carbonation of concrete
water structures
corrosion of steel
pH of water
Opis:
Beton z racji swej zasadowości (wartość współczynnika pH ? 12) stanowi warstwę ochronną stali zbrojeniowej przed korozją. W wyniku szkodliwego wpływu wody, dwutlenku węgla oraz soli, odczyn alkaiczny ulega obniżeniu. Przy wartości pH=10 (11) beton wykazuje tylko niewielką lub w ogóle żadną aktywność korozyjną stali zbrojeniowej. Zwiększenie się objętości korodującej stali zbrojeniowej (pęcznienie) w następstwie utraty alkaiczności betonu nazywamy karbonatyzacją betonu. W oparciu o wyniki badań stopnia karbonatyzacji betonu elementów żelbetowych zbiornika retencyjnego do głębokości 2,5 cm stwierdzono początek procesu karbonatyzacji szczególnie w strefie falowania wody oraz częściowo w strefie powyżej maksymalnego poziomu piętrzenia wody. Na stopień karbonatyzacji elementów żelbetowych budowli hydrotechnicznych ma istotny wpływ pH wody (śr. pH wody zretencjonowanej w zbiorniku wynosiło od 7,6 - 7,9).
Źródło:
Zeszyty Naukowe. Inżynieria Lądowa i Wodna w Kształtowaniu Środowiska; 2009, 1; 35-42
2082-6702
Pojawia się w:
Zeszyty Naukowe. Inżynieria Lądowa i Wodna w Kształtowaniu Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problemy uzdatniania wód powierzchniowych ujmowanych w rejonach podgórskich
Technological problems faced during treatment of soft surface waters in the piedmont area of South Poland
Autorzy:
Maćkiewicz, J.
Dziubek, A. M.
Powiązania:
https://bibliotekanauki.pl/articles/236352.pdf
Data publikacji:
2004
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
soft water
buffering
pH adjustment
water treatment
NOM removal
Opis:
Uzdatnianie wód o twardości poniżej 10 otw. (ok. 180 gCaCO3/m3) - tzw. wody miękkie - nastręcza wiele trudności technologicznych, wynikających z niskiej buforowości tych wód. Omówione w pracy miękkie wody powierzchniowe, występujące w rejonie Pogórza Sudeckiego, charakteryzują się niską mętnością, lecz podwyższoną barwą i wysoką zawartością substancji organicznych. Zwrócono szczególną uwagę na problemy technologiczne wynikające z chemizmu procesu koagulacji wód o niskiej zasadowości. Omówiono metody oczyszczania wód, szczególnie zawierających podwyższone ilości substancji organicznych, takie jak koagulacja w złożach filtracyjnych, filtracja powolna poprzedzona filtracją horyzontalną (HRF - Horizontal Roughing Filter), technologia MIEX-DOCŽ, wykorzystująca namagnetyzowane żywice anionowymienne. Podkreślono możliwość stosowania układów technologicznych eliminujących proces koagulacji, a także wskazano na inne problemy wynikające ze stosowania nowych rozwiązań w układach oczyszczania wody.
The treatment of low-hardness water (below appr. 180 gCaCO3/m3), i.e. soft water, raises many technological problems, resulting from a poor buffering. The surface waters reported on in this paper come from the Sudeten Piedmont Region and are characterized by a relatively low turbidity, as well as an increased coloured matter content and a high organic substances concentration. In this study, particular consideration was given to the technological problems that arise from the chemistry of soft water coagulation. Treatment methods were discussed (with emphasis on those for water with increased organic matter content), such as coagulation in filter beds, slow filtration with the HRF process as a prior step, or the MIEX-DOCŽ technology involving magnetized anion-exchange resins. Potential applications of technological trains with no coagulation process were analyzed, and the implications of using modified treatment technologies were considered.
Źródło:
Ochrona Środowiska; 2004, R. 26, nr 4, 4; 17-20
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Storage and its Effect on Chemical Quality Indicators in Sachet Water Brands Sold in Owerri Municipal, Imo State, Nigeria
Autorzy:
Duru, Chidi Edbert
Amadi, Uzoamaka Sandra
Enyoh, Christian Ebere
Powiązania:
https://bibliotekanauki.pl/articles/1113927.pdf
Data publikacji:
2017
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Dissolved oxygen
Nitrate
Phosphate
Sachet water
Water quality
pH
Opis:
This study investigated the effect of storage on certain sachet water quality indicators over a twelve-week period. Three brands of sachet water were collected within 24 h of production and analyzed for pH, nitrate, phosphate and dissolved oxygen. These were then placed in normal storage. According to out results, pH values increased significantly in all brands after week 8. Moreover, nitrate and dissolved oxygen values decreased throughout the investigation period, while phosphate values increased in all brands tested. All tested brands showed various degree of variation over the period of study. Still, all brands analyzed were within permissible limit by World Health Organization (WHO) stipulations. However, continuous storage can significantly alter the chemical quality indicators to a level that exceeds the limit set by WHO; hence, becoming harmful to human health. Therefore, it is recommended that sachet water should not be stored for more than 12 weeks from the date of production.
Źródło:
World News of Natural Sciences; 2017, 12; 73-81
2543-5426
Pojawia się w:
World News of Natural Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Applying of water quality indices methods for assessment of 9-Nissan Water Treatment Plant
Autorzy:
Abdul-Hameed, Hayder M.
Powiązania:
https://bibliotekanauki.pl/articles/1844403.pdf
Data publikacji:
2020
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
nitrate
pH
suspended solids
water quality index
water treatment plant
Opis:
In this research different methods for measuring water quality indices were conducted to investigate the performance of the newly designed, constructed and operated 9-Nissan water treatment plant, Iraq. Data gathering and implementation took place throughout winter and summer. Water samples were taken periodically, according to the standard method, the research was carried out by collecting different random samples for eight months (Jun. 2015–Jan. 2016) and measuring (turbidity, total hardness, pH, total dissolved solids, suspended solids, Cl–, Mg2+, Fe2+,NO3–, NH3+) for each sample. Five different approaches and methodologies of calculating the water index were applied. The results revealed that the Water Quality Indices varied from 70.55 to 88.24, when applying Canadian Council of Ministers of the Environment Water Quality Index (CCMEWQI) and British Columbia water quality index (BCWQI) geometric weighted mean respectively. All the results, from the five approaches indicated good water quality, multiple regression analyses were conducted for turbidity, total hardness and suspended solids, they found that these parameters are strongly related to each other and to other parameters.
Źródło:
Journal of Water and Land Development; 2020, 47; 25-29
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ temperatury i pH na skuteczność usuwania zanieczyszczeń z wody podziemnej w procesie koagulacji
Effect of temperature and pH on the effectiveness of pollutant removal from groundwater in the process of coagulation
Autorzy:
Krupińska, I.
Powiązania:
https://bibliotekanauki.pl/articles/237866.pdf
Data publikacji:
2015
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie wody
pH
siarczan glinu
chlorki poliglinu
water treatment
pH value
alum
polyaluminum chloride
Opis:
Przedmiotem badań była woda podziemna z utworów czwartorzędowych o zwiększonej zawartości substancji organicznych, której oczyszczanie w układzie konwencjonalnym stwarza problemy technologiczne. Przeprowadzone badania laboratoryjne wykazały, że koagulanty wstępnie zhydrolizowane (Flokor 1, Flokor 1ASW) zapewniły większą skuteczność usuwania zanieczyszczeń organicznych (OWO, RWO) i nieorganicznych (Fe, Mn) z wody podziemnej niż siarczan(VI) glinu, ze względu na większą zawartość polimerowych form glinu. Zakwaszenie wody przed procesem koagulacji do pH=6, bez względu na rodzaj testowanego koagulantu, zwiększyło skuteczność usuwania substancji organicznych oraz zanieczyszczeń powodujących barwę wody, natomiast alkalizacja wody do pH=8,5 zwiększyła skuteczność usuwania związków żelaza, manganu oraz cząstek powodujących mętność wody. Wykazano, że wraz ze wzrostem stopnia polimeryzacji testowanych koagulantów glinowych zmniejszała się zawartość glinu pozostałego w oczyszczonej wodzie, a także wrażliwość koagulantu na zmiany temperatury i pH oczyszczanej wody.
The subject of this research was groundwater from Quaternary formations with the increased concentration of organic substances. Successful treatment of such water generates technological problems and is practically impossible by means of traditional groundwater treatment processes. Laboratory tests showed that the prehydrolyzed aluminum coagulants (Flokor 1, Flokor 1ASW) had higher efficacy of organic (TOC, DOC) and inorganic (Fe, Mn) compound removal from groundwater than alum due to higher content of polymeric aluminum species. Water acidification up to pH=6 prior to coagulation, regardless of the coagulant type, led to an increased efficacy of organic substances and color impurities removal. Moreover, alkalization of water up to pH=8.5 resulted in more efficient removal of iron, manganese and particles being a measure of water turbidity. It was demonstrated that with an increase in polymerization degree of aluminum coagulants both the remaining aluminum concentration in treated water as well as the coagulant sensitivity to changes in temperature and pH of the treated water decreased.
Źródło:
Ochrona Środowiska; 2015, 37, 3; 35-42
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of the Hydrosystem and Environmental Monitoring of Water Quality of the Ponds and Water Sources in the National Dendrological Park "Sofiyivka" of the NAS of Ukraine
Autorzy:
Balabak, Oleksandr
Muzyka, Hryhorii
Balabak, Alla
Vasylenko, Olha
Nikitina, Olha
Hnatiuk, Nataliia
Rumiankov, Yurii
Porokhniava, Olha
Tsybrovska, Nadiia
Hurskyi, Ihor
Powiązania:
https://bibliotekanauki.pl/articles/24201634.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
water
pH value
total hardness
chlorides
sulfates
nitrates
nitrites
Opis:
At present, the problem of the availability of high-quality fresh water is urgent. The reservoirs from which water is extracted are running low. The amount of fresh water on the planet has decreased significantly in recent years. A big problem for the use of fresh water is its pollution. Groundwater remained relatively clean, but even when used, it needs to be controlled. Goal of research was the quality control of water from ponds and water sources in the National Dendrological Park (NDP) "Sofiyivka" of the National Academy of Sciences (NAS) of Ukraine in terms of physicochemical and bacteriological indicators and a study of the park's hydrosystem. When conducting research, potentiometric, gravimetric, titrimetric, colorimetric and spectrophotometric methods were used. The hydrosystem of the NDP "Sofiyivka" of the NAS of Ukraine, created during the period of its foundation, has basically retained its planning forms and all its artificial structures. The water system is an important environmental factor that contributes to the quality development of plants, and also has an aesthetic value. The analysis of the results of a study of the physicochemical and bacteriological composition of drinking water from the studied water catchments showed that the water is safe for consumption in terms of such indicators as the content of sulfates, nitrites, chlorides, but contains a significant amount of nitrates and has a high hardness, which can contribute to the development of a number of diseases. Long-term consumption of such water will have a negative impact on the human body. In all water samples from the capture, the growth of common coliforms in 100 cm3 and the presence of Escherichia coli were found, which is dangerous when drinking unboiled water and can bring to intestinal infectious diseases. According to the obtained experimental results of the quality of the studied water samples from the Krasnostavsky, Upper and Lower ponds of the NDP "Sofiyivka" NAS of Ukraine, the general physical and chemical indicators fully comply with the established standards, but the results of studies of the ponds in terms of bacteriological indicators, namely the index of lactose-positive E. coli indicate their significant excess and non-compliance with the standards in the Krasnostavsky and Verkhny ponds by 48 and 12 times, respectively.
Źródło:
Journal of Ecological Engineering; 2023, 24, 3; 178--187
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Buffering of pulp pH and its influence on process water chemistry during iron ore flotation
Autorzy:
Tang, Min
Xiao, Qingfei
Powiązania:
https://bibliotekanauki.pl/articles/1446441.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
pulp pH
buffering
water chemistry
mineral dissolution
iron oxide
Opis:
It is inevitable for the occurrences of pulp pH buffering during pH control in flotation as the minerals with acidic/alkali properties tend to interact with pH modifiers and restore the pulp pH. This could result in some disturbing ions and alter the water/pulp chemistry. The purpose of this study was to identify the influences of pulp pH buffering on process water chemistry through a series of pH buffering tests, bench flotation experiments, ore dissolution tests, zeta potential measurement, and Xray diffraction (XRD) analysis. The built-up and distribution of the dominant cations in the process water from different locations in an industrial flotation system of the iron ore were analyzed and recorded by Inductively Coupled Plasma-Optical Emission (ICP-OES) at a period of about six months when the operations were stable. The data showed that a near five-minute buffer of pulp pH at a range from near 7.9 to 8.9 occurred before it reached a stable value. At this period, the dissolution of Ca/Mg from the iron ore was dominant. And, the pulp pH at a lower value tended to induce more dissolved $Ca^{2+}$ and $Mg^{2+}$ ions. These divalent cations seem to have different influences on the flotation properties of iron oxides at the same concentrations, indicating a positive effect on the recovery of iron oxides with the presence of $Mg^{2+}$ ions but an opposite effect if $Ca^{2+}$ ions occurred. The presence of sulfate, however, tended to restore the floatability of silicate depressed by $Ca^{2+}$ ions.
Źródło:
Physicochemical Problems of Mineral Processing; 2021, 57, 4; 157-167
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie wstępnego utleniania i korekty pH do usuwania substancji organicznych z wód miękkich
Enhancement of organic matter removal from soft water by applying pre-oxidation and pH adjustment as prior step to the coagulation process
Autorzy:
Gumińska, J.
Powiązania:
https://bibliotekanauki.pl/articles/236356.pdf
Data publikacji:
2004
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
wody miękkie
substancje organiczne
koagulacja
wstępne utlenianie
obniżanie pH
soft water
organic compounds
coagulation
pre-oxidation
pH adjustment
Opis:
W celu zwiększenia skuteczności usuwania związków organicznych niektóre stacje oczyszczania wody wprowadzają wstępne utlenianie przed procesem koagulacji. Stosowanie takiego rozwiązania jest jednak ograniczone z uwagi na niebezpieczeństwo pojawienia się ubocznych produktów utlenienia. Aby wyeliminować niekorzystne skutki tego procesu ważny jest właściwy wybór utleniacza (i jego dawki), który zapewni uzyskanie wymaganej jakości wody. Ze względu na możliwość tworzenia się kancerogennych THM nie powinno się stosować chloru, można natomiast rozpatrywać zastosowanie ozonu lub dwutlenku chloru. Wprawdzie w reakcji dwutlenku chloru z substancjami humusowymi również powstają THM, ale stanowią one 1¸25% ilości, która powstaje w czasie chlorowania. Skuteczność usuwania związków organicznych z wody jest największa w środowisku kwasowym (pHť5) i maleje wraz ze wzrostem pH powyżej tej wartości lub wartości optymalnej dla danej wody. W pracy zaprezentowano wyniki badań przeprowadzonych w skali laboratoryjnej i pilotowej, które miały na celu ustalenie, czy proces wstępnego utleniania, bądź wstępnego obniżania pH wody może mieć korzystny wpływ na usuwanie związków organicznych z wód miękkich w procesie koagulacji. Stwierdzono, iż możliwe jest usunięcie prekursorów THM w procesie koagulacji powierzchniowej, której skuteczność można zintensyfikować poprzez wstępne obniżenie pH wody przed dawkowaniem koagulantu.
To enhance the removal of organic pollutants some treatment plants include pre-oxidation into the treatment train as a prior step to coagulation. There is a risk that the oxidation reaction may yield undesired by-products. It is therefore essential to choose the right oxidant and its dosage. If chlorine increases the concentration of disinfection by-products (THM), ozone or chlorine dioxide should be considered. Although the reaction of chlorine dioxide with humic substances also produces THMs, the amount of the THMs produced constitutes 1 to 25% of the amount generated during chlorination. Organic matter removal by coagulation is the highest at pHť5. The objective of our study was to establish whether or not the inclusion of pre-oxidation, or pH adjustment into the treatment train has a desirable effect on the removal of organic compounds from soft water by coagulation. It was found that direct coagulation enabled the removal of THM precursors and that the efficiency of the process can be enhanced by the pH adjustment before treating the water with the coagulant.
Źródło:
Ochrona Środowiska; 2004, R. 26, nr 4, 4; 9-12
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characteristics of the physical and chemical parameters of water in pools of port in Szczecin in 2009
Autorzy:
Cyraniak, E.
Daniszewski, P.
Draszawka-Bołzan, B.
Powiązania:
https://bibliotekanauki.pl/articles/411965.pdf
Data publikacji:
2013
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
swimming pools port
natural water quality
pH
BOD5
COD-Cr
Opis:
The aim of this work was to be traced during the summer and autumn of 2009 the level and dynamics of changes in the waters of the Port of Szczecin General docks parameters water quality. In the work of the General indicators of water temperature, were numbered: pH, BOD5, COD-Cr, Cl-. All the markings and the calculation was performed according to the methods recommended by Polish Standards, applying analytical procedures described in by Dojlido, Elbanowska, Hermanowicz. Port of Szczecin is located on the Oder river and its right shoulder Regalicy. Is located in the western part of the port of Szczecin, in the northern part of the Valley of the lower Oder river on May. The port consists of water bodies which are branches of the Oder river and the channels: Mielenski, Grabowski, Dunczyca Channel Figh, Wroclaw, Parnica, Channel Channel Debicki and Lake Dabie. Trying is water were collected by PN/C-04632.03 with a depth of about. 2 m below the water surface. The temperature at the place of sampling were numbered, pH. Collected water samples were fixed In accordance with the recommendations in the Polish Standard-PN/C-04632.04. Other indicators for the quality of the waters have been tagged within 24 hours from the moment of download attempts. The quality objectives was evaluated according to the criteria recommended to evaluate inland surface waters referred to in regulation of the Minister of the environment of 11 February 2004 on the classification for the present status of surface water and groundwater, how to conduct monitoring and how to interpret the results and presentation of these waters. Due to the exposure of the docks the port Szczecin on the pollution associated with cross-what are the cereals, ores, oil, cellulose, carbon, iron, general research evaluation of the water quality of these pools, you can assess the status of water In order to keep these waters.
Źródło:
International Letters of Chemistry, Physics and Astronomy; 2013, 1; 70-77
2299-3843
Pojawia się w:
International Letters of Chemistry, Physics and Astronomy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Relationship between selected quality characteristics and levels of water-soluble proteins in porcine longissimus muscle
Zależność między wybranymi cechami jakościowymi wieprzowego mięśnia longissimus a zawartością w nim białek rozpuszczalnych w wodzie
Autorzy:
Karamucki, T.
Powiązania:
https://bibliotekanauki.pl/articles/29433588.pdf
Data publikacji:
2022
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
pig
longissimus lumborum muscle
pork quality
indicator
pH
water-soluble protein
Źródło:
Acta Scientiarum Polonorum. Zootechnica; 2022, 21, 4; 23-30
1644-0714
Pojawia się w:
Acta Scientiarum Polonorum. Zootechnica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On differences in chemical composition occurring between surface and near bottom water in the Szczecin Lagoon
O występowaniu zróżnicowania składu chemicznego wód powierzchniowych i przydennych w Zalewie Szczecińskim
Autorzy:
Poleszczuk, G.
Piesik, Z.
Powiązania:
https://bibliotekanauki.pl/articles/85077.pdf
Data publikacji:
2000
Wydawca:
Akademia Pomorska w Słupsku
Tematy:
chemical composition
surface water
bottom water
Szczecin Lagoon
water chemistry
estuary
water temperature
oxygen concentration
pH
chlorinity
water quality
quality indicator
water body
Źródło:
Baltic Coastal Zone. Journal of Ecology and Protection of the Coastline; 2000, 04
1643-0115
Pojawia się w:
Baltic Coastal Zone. Journal of Ecology and Protection of the Coastline
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computation of the effect of pH on spur chemistry in water radiolysis at elevated temperatures
Autorzy:
Swiatla-Wojcik, D.
Powiązania:
https://bibliotekanauki.pl/articles/147674.pdf
Data publikacji:
2008
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
effect of pH
radiolysis of water
elevated temperatures
diffusion-kinetic calculations
Opis:
Diffusion-kinetic model has been employed to calculate the effect of pH and associated ionic strength on the primary yields in the radiolysis of water from ambient temperature to 200°C. Account has been taken of the effect of ionic strength, I, up to 0.1 molźdm-3 in both acidic and alkaline solutions resulting from the addition of H+ and OH-,assuming the counter ions have unit charge. The primary yields are essentially independent of pH for I ? 10-4. AboveI = 10-4 molźdm-3 the primary yields of e-aq and H2 in acidic solutions decrease whereas the primary yields of the H atom, hydroxyl radical and hydrogen peroxide increase. At I >10-3 molźdm-3 in alkaline solutions, the OH radical and hydrogen peroxide are partially converted into Oo- and HO-2 , respectively. Increases in the total yields GoOH + GOo- and Ge-aq + GHo and a decrease in GH2O2 + GHO-2 have been found with increasing pH. At elevated temperatures the effect of pH is diminished. The temperature effect on the primary yields in acidic and alkaline solutions is nearly the same as in neutral water.
Źródło:
Nukleonika; 2008, 53, suppl. 1; 31-37
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characteristics of the physical and chemical parameters of water in pools of port in Swinoujscie in 2009
Autorzy:
Cyraniak, E.
Daniszewski, P.
Draszawka-Bołzan, B.
Powiązania:
https://bibliotekanauki.pl/articles/411959.pdf
Data publikacji:
2013
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
swimming pools port
natural water quality
pH
BOD5
COD-Cr
Opis:
The aim of this work was to be traced during the summer and autumn of 2009 the level and dynamics of changes in the waters of the port the port Swinoujscie general parameters pools water quality. In the work of the General indicators of water temperature, were numbered: pH, BOD5, CODCr, Cl-. All the markings and the calculation was performed according to the methods recommended by Polish Standards, applying analytical procedures described in. by Dojlido, Elbanowska, Hermanowicz. Port of Swinoujscie is a sea port located on the Gulf of Pomorska, on the southern coast of the Baltic Sea, on the islands of Usedom and Wolin. The Port is located at the Swina, In Swinoujscie, West Pomeranian Voivodeship. The port can be placed on ships with a maximum length of 42.0 m and width 260,0 m, draught 12.8 m. The tides in the Harbor, but the water level fluctuations are possible with sudden currents entering and outgoing, which depending on the direction of prevailing winds and reaching speeds of up to 1.5 knots. At the entrance to the port at the West breakwater, It is Western. The primary function of the port of Swinoujscie is the transshipment of cereals, ores, oil, paper, cellulose, general cargo, coal, iron. Trying to test water were collected by PN/C-04632.03 with a depth of about. 2 m below the water surface. The temperature at the place of sampling were numbered, pH. Collected water samples were fixed in accordance with the recommendations in the Polish Standard-PN/C-04632.04. Other indicators for the quality of the Walters have been tagged within 24 hours from the moment of download attempts. The quality objectives was evaluated according to the criteria recommended to evaluate inland surface waters referred to In regulation of the Minister of the environment of 11 February 2004 on the classification for the prezent status of surface water and groundwater, how to conduct monitoring and how to interpret the results and presentation of these waters. Due to the exposure of the docks the port Swinoujscie on the pollution associated with cross-what are the cereals, ores, oil, cellulose, carbon, iron, general research evaluation of the water quality of these pools, you can assess the status of water in order to keep these waters.
Źródło:
International Letters of Chemistry, Physics and Astronomy; 2013, 1; 78-84
2299-3843
Pojawia się w:
International Letters of Chemistry, Physics and Astronomy
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies