Tytuł:
Numerical analysis of the strain distribution underneath the surface of polyethylene flat and spherical inserts with metal sled
Autorzy:
Nabrdalik, M.
Powiązania:
https://bibliotekanauki.pl/articles/122836.pdf
Data publikacji:
2014
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
strain
endoprosthesis
odkształcenie
endoproteza
Opis:
Most of the mechanical failures in alloplasty are caused by material fatigue. To cut down the risk of it, we can either increase the fatigue resistance of the material or decrease the load strain. All presented numerical calculations allow to draw quality conclusions concerning the influence of some parameters of endoprostheses on the values of stress and strain that are formed in polyethylene inserts.
Źródło:
Journal of Applied Mathematics and Computational Mechanics; 2014, 13, 4; 97-102
2299-9965
Pojawia się w:
Journal of Applied Mathematics and Computational Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stress occurring in the friction node of elements in the total knee endoprosthesis
Autorzy:
Nabrdalik, M.
Powiązania:
https://bibliotekanauki.pl/articles/122963.pdf
Data publikacji:
2015
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
endoprosthesis
stress
FEM
endoproteza
naprężenie
MES
Opis:
The paper presents the numerical analysis of stress occurring in the friction node of bi-condylar knee endoprostheses. The Finite Elements Method allows one to calculate and present the stress distribution in all elements of the computing model.
Źródło:
Journal of Applied Mathematics and Computational Mechanics; 2015, 14, 2; 41-48
2299-9965
Pojawia się w:
Journal of Applied Mathematics and Computational Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Use of the Finite Element Method in the analysis of load of polyethylene inserts of knee joint endoprosthesis
Autorzy:
Nabrdalik, M.
Powiązania:
https://bibliotekanauki.pl/articles/122634.pdf
Data publikacji:
2014
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
contact stress
FEM
endoprosthesis
naprężenie kontaktowe
endoproteza
Opis:
The paper presents the numerical analysis of stress occurring in the most wearable parts of knee joint endoprostheses. That applies to the pair: sled - spherical insert. The Finite Elements Method makes it possible to calculate the stress in particular elements of the tested model. The interaction between the two parts of endoprosthesis takes place on a comparatively small contact surface.
Źródło:
Journal of Applied Mathematics and Computational Mechanics; 2014, 13, 2; 87-93
2299-9965
Pojawia się w:
Journal of Applied Mathematics and Computational Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie teorii zbiorów przybliżonych do analizy wyników badań emisji jonów metali w endoprotezach stawu biodrowego
Application of rough set theory to analyse the results of emission tests of metal ions in hip endoprosthesis
Autorzy:
Wiśniewski, T.
Libera, M.
Powiązania:
https://bibliotekanauki.pl/articles/188366.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
endoproteza
teoria zbiorów przybliżonych
endoprosthesis
rough set theory
Opis:
Celem pracy była ocena przydatności teorii zbiorów przybliżonych w analizie zużycia endoprotez. W pracy wyodrębnić można dwie zasadnicze części: w pierwszej opisano badania tribologiczne endoprotez stawu biodrowego, natomiast w drugiej dokonano analizy wyników tych badań, wykorzystując metodę generowania reguł decyzyjnych w oparciu o teorię zbiorów przybliżonych. W efekcie stwierdzono, że wygenerowane reguły decyzyjne nie są sprzeczne z aktualnym stanem wiedzy, a zaproponowana metoda analizy może być przydatna w analizie tego rodzaju zagadnień.
The aim of the study was to evaluate the usefulness of rough set theory in the analysis of endoprosthesis wear. In the article, two main parts can be distinguished: the first describes the tribological study of hip endoprosthesis, while the second analyses the results of these tests using the method of generating decision rules based on rough set theory. There were generated two sets of decision rules describing the impact of roughness, friction, wear and the angle of the prosthesis head on the chromium, and cobalt ions emission. As a result, it was found that the generated decision rules are consistent with the current state of knowledge, and the proposed method of analysis may be useful in the analysis of such issues.
Źródło:
Tribologia; 2015, 4; 207-219
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie endoprotezy stawu kolanowego
Designing total knee endoprosthesis
Autorzy:
Chruścicka, N.
Ciepielowski, D.
Łagan, S.
Powiązania:
https://bibliotekanauki.pl/articles/98716.pdf
Data publikacji:
2012
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
staw kolanowy
endoproteza
modelowanie
knee joint
endoprosthesis
modelling
Źródło:
Aktualne Problemy Biomechaniki; 2012, 6; 15-20
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena zużycia metalowych głów endoprotez stawu biodrowego usuniętych z organizmu ludzkiego z powodu aseptycznego obluzowania
Assessment of wear of metal heads in hip joint prosthesis removed from human body due to aseptic loosening
Autorzy:
Szarek, A.
Powiązania:
https://bibliotekanauki.pl/articles/284872.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
zużycie
biomateriał metaliczny
endoproteza
chropowatość
wear
metallic biomaterial
endoprosthesis
roughness
Opis:
W pracy przedstawiono wyniki oceny stanu powierzchni głów endoprotez stawu biodrowego współpracujących z panewką polietylenową w organizmie ludzkim w okresie od sześciu do jedenastu lat. Badania obejmowały optyczną ocenę stanu powierzchni przy pomocy mikroskopu stereoskopowego oraz ocenę profilu chropowatości współpracującej (zużytej) części głowy endoprotezy.
The paper presents the results of assessment of condition of head surface in hip joint prosthesis mating polyethylene acetabulum in human body throughout the period of 6-11 years. The investigations focused on visual assessment ofthe surface condition by means of a stereoscopic microscope and assessment of the roughness profiles in the mating (worn) part of the prosthesis head.
Źródło:
Engineering of Biomaterials; 2008, 11, 74; 6-10
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of finite elements method for analyzing the load occurring in components of endoprostheses
Wykorzystanie metody elementów skończonych do analizy obciążeń występujących w komponentach endoprotez
Autorzy:
Sobociński, M.
Nabrdalik, M.
Powiązania:
https://bibliotekanauki.pl/articles/261533.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
endoprosthesis
FEM
contact stress
endoproteza
metoda elementów skończonych
naprężenia kontaktowe
Opis:
This paper presents numerical analysis of strength in virtual hip and knee joints by means of the finite elements method FEM. Predicting the places in implants, where damage or premature wear may occur, is extremely important. The obtained results helped to exhibit weak points in examined models, and thus may be used to protect premature wear of endoprosthesis elements. The numerical analysis was based on the finite elements method FEM using Autodesk Simulation Mechanical 2016 software and the ADINA 7.5.1.
Celem pracy była numeryczna analiza wytrzymałościowa zmian w wirtualnym stawie biodrowym i kolanowym. Zastosowano metodę elementów skończonych. Zastosowanie rozwiązań analitycznych mających na celu wykazanie możliwych miejsc w modelu, gdzie dochodzić może do uszkodzeń lub przedwczesnego zużycia współpracujących elementów, jest niezmiernie ważne. Otrzymane wyniki uwidoczniły takie miejsca, a tym samym mogą być wykorzystane do przeciwdziałania skutkom wynikającym z przedwczesnego zużycia elementów endoprotezy. Analiza numeryczna została wykonana w oparciu o metodę elementów skończonych przy wykorzystaniu oprogramowania Autodesk Simulation Mechanical 2016 oraz ADINA 7.5.1.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2017, 23, 3; 166-175
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The morphology of the articular surfaces of biological knee joints provides essential guidance for the construction of functional knee endoprostheses
Autorzy:
Nagerl, H.
Dathe, H.
Fiedler, Ch.
Gowers, L.
Kirsch, S.
Kubein-Meesenburg, D.
Dumont, C.
Wachowski, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/307060.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
kolano
kinematyka
biomechanika
endoproteza
knee arthroplasty
kinematics
biomechanics
knee
endoprosthesis
pig
Opis:
Purpose: In comparative examinations of kinematics of the knees of humans and pigs in flexional/extensional motion under compressive loads, the significant differential geometric essentials of articular guidance are elaborated to criticise the shaping of the articular surfaces of conventional knee-endoprostheses and to suggest constructional outlines that allow the endoprosthesis to adopt natural knee kinematics. Implantation is discussed with regard to the remaining ligamentous apparatus. Methods: Twelve fresh pig knee joints and 19 preserved human knee joints were moved into several flexional/extensional positions. In each joint, the tibia and femur were repeatably caught by metal plates. After removing all ligaments, the tibia and femur were again caught in these positions, and their points of contact were marked on both articular surfaces. Along the marker points, a thin lead wire was glued onto each surface. The positions and shapes of the four contact lines were mapped by teleradiography. Results: All contact lines were found to be plane curves. The medial and lateral planes were parallel, thus defining the joint’s sagittal plane. In the human knee, as compared to the lateral, the medial femoral contact line was always shifted anteriorly by several millimetres. The tibial contact curve was laterally convex and medially concave. In the pig knees, the lateral and medial contact lines were asymmetrically placed. Both tibial curves were convex. Conclusions: Both knees represent cam mechanisms (with one degree of freedom) that produce rolling of the articular surfaces during the stance phase. Implantation requires preservation of the anterior cruciate ligament, and ligamentous balancing is disadvantageous.
Źródło:
Acta of Bioengineering and Biomechanics; 2015, 17, 2; 45-53
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wytrzymałościowa endoprotezy stawu kolanowego
Strength analysis of total knee prosthesis
Autorzy:
Tejszerska, D
Długoszewski, T.
Gąsiorek, D
Powiązania:
https://bibliotekanauki.pl/articles/99077.pdf
Data publikacji:
2010
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
analiza wytrzymałościowa
endoproteza
staw kolanowy
ANSYS
strength analysis
endoprosthesis
knee joint
Opis:
W artykule przedstawiono analizę wytrzymałościową endoprotezy stawu kolanowego z wyłączeniem elementu udowego dla kilku wariantów obciążenia. Analiza ta pozwala na obserwację wpływu obciążenia na stan naprężeń i odkształceń w kości i endoprotezie. Model i jego analizę przeprowadzono metodą elementów skończonych w programie Ansys Workbench.
Numerical strength analysis of total knee prosthesis without femur element for few variants of load was presented in this paper. This analysis allow us observe the influence of load on the state of stress and strain in tibia bone and prosthesis . The model and its finite element analysis was performed in ANSYS Workbench.
Źródło:
Aktualne Problemy Biomechaniki; 2010, 4; 213-218
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on Friction Wear of Hip Joint Endoprostheses of Polyethylene-Metal Material Combination on Hip Joint Simulator
Badania tribologiczne endoprotez stawu biodrowego o skojarzeniu polietylen–metal na symulatorze stawu biodrowego
Autorzy:
Wiśniewski, T.
Wielowiejska-Giertuga, A.
Rubach, R.
Łapaj, Ł.
Magda, J.
Powiązania:
https://bibliotekanauki.pl/articles/971352.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
endoprosthesis
wear
polyethylene-on-metal articulation
endoproteza
zużycie
skojarzenie materiałowe polietylen–metal
Opis:
The article presents the results of friction wear tests of hip joint endoprostheses. The study comprised tests of endoprostheses, commercially available on the European market, used in total hip arthroplasty. The friction pair was formed by an actual cupacetabular cup made of ultra-high molecular weight polyethylene (PE-UHMW) along with a head having a diameter of 28 mm made of stainless steel FeCrNiMnMoNbN. The friction and wear tests were performed using an SBT 01.2 hip joint simulator of the authors’ own design, which was constructed taking into account the ISO 14242-1 standard. Bovine serum was used as the lubricant. The tests of each friction pair were made up to 5·106cycles of motion. During the tests, simulator operation was interrupted every 5·105 cycles to replace the lubricating liquid, and mass control was performed every 1·106 cycles. Prior to testing, the polyethylene cup was soaked in the lubricant to minimize liquid absorption during the test. Proper preparation of the cup and testing by taking into account a control group weight measurement allowed an accurate determination of the mass loss of the polyethylene cup.
Przedstawiono wyniki badań tarciowo-zużyciowych endoprotez stawu biodrowego. Materiał badany stanowiły endoprotezy komercyjne dostępne na rynku europejskim, stosowane w alloplastyce całkowitej stawu biodrowego. Parę trącą tworzyła panewka wykonana z polietylenu o ultrawysokiej masie cząsteczkowej PE-UHMW wraz z głową o średnicy 28 mm wykonaną ze stali o symbolu producenta SS (FeCrNiMnMoNbN). Badania tarciowo-zużyciowe przeprowadzono przy użyciu symulatora ruchu stawu biodrowego SBT 01.2 własnej konstrukcji, który skonstruowany został w oparciu o normę ISO 14242-1. Jako medium smarujące zastosowano surowicę bydlęcą, która przygotowywana była do testów zgodnie z wytycznymi opisanymi w normie ISO 14242-1. Dla każdej pary trącej zadana liczba cykli ruchu wynosiła 5·106. W trakcie trwania testów, co 5·105 cykli praca symulatora była przerywana celem wymiany cieczy smarującej, a co 1·106 przeprowadzano kontrolę masy próbek. Przed przystąpieniem do testów tarciowo-zużyciowych polietylenowa panewka namaczana była w cieczy smarującej celem zminimalizowania absorpcji cieczy w trakcie trwania testu. Odpowiednie przygotowanie panewek oraz przeprowadzenie testu z uwzględnieniem grupy kontrolnej pozwoliło na określenie zużycia masowego panewek polietylenowych.
Źródło:
Tribologia; 2018, 281, 5; 153-158
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the loads occurring in a modular hip joint endoprosthesis
Autorzy:
Sobociński, M.
Powiązania:
https://bibliotekanauki.pl/articles/122656.pdf
Data publikacji:
2016
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
endoprosthesis
FEM
finite elements method
contact stress
endoproteza
naprężenia kontaktowe
analiza obciążenia
Opis:
This paper contains the results of the load analysis of a modular hip joint endoprosthesis, performed by means of the finite elements method, using Autodesk Simulation Mechanical 2016 software. A geometric model was created based on real solutions using Autodesk Inventor Professional. The obtained results make it possible to indicate the “weak points” of the accepted solution, and thus counteract the subsequent effects resulting from premature wear of endoprosthesis elements.
Źródło:
Journal of Applied Mathematics and Computational Mechanics; 2016, 15, 3; 135-142
2299-9965
Pojawia się w:
Journal of Applied Mathematics and Computational Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza procesów tribologicznych występujących w skojarzeniu panewka–główka endoprotezy stawu biodrowego
The analysis of the tribological processes occurring in the socket-and-ball friction pair of a hip joint endoprosthesis
Autorzy:
Niemczewska-Wójcik, M.
Piekoszewski, W.
Powiązania:
https://bibliotekanauki.pl/articles/190930.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
staw biodrowy
endoproteza
topografia powierzchni
zużywanie
hip joint
endoprosthesis
surface topography
wear
Opis:
W pracy przedstawiono staw biodrowy jako idealne biołożysko. Omówiono przyczyny uszkodzenia naturalnego stawu biodrowego człowieka oraz sposoby przywrócenia utraconych funkcji, w tym alloplastykę stawów. W części badawczo- -analitycznej pracy omówiono przyczyny obniżenia trwałości endoprotez stawu biodrowego w oparciu obadania własne in vitro. Przedmiotem badań było skojarzenie panewka–główka endoprotezy stawu biodrowego. Powierzchnie badanych elementów zostały przygotowane zgodnie z wytycznymi norm. Badania tribologiczne przeprowadzono w otoczeniu płynu Ringera. Badania stanu powierzchni przed i po eksploatacji przeprowadzono na trzech urządzeniach: współrzędnościowej maszynie pomiarowej, mikroskopie interferometrycznym oraz skaningowym mikroskopie elektronowym. Wyniki przeanalizowano pod kątem procesów tribologicznych (mechanizmów zużycia) występujących w skojarzeniu polimerowa panewka–metalowa główka endoprotezy stawu biodrowego.
The paper presents a hip joint as an ideal system. The causes of the damage to a natural human hip joint and the ways of restoring its lost functions along with hip joint alloplasty are discussed. In the research part of this paper, based on in vitro study, the reasons for the loss of artificial hip joint durability are described. The subject of the research was the socket-andball friction pair, making the elements of a hip joint endoprosthesis. The surfaces of the analysed samples were prepared in accordance with the guidelines of the standards. The tribological tests were conducted in the environment of Ringer's solution. The examination of the surface topography before and after tribological tests was carried out with three units: a coordinate measurement machine, white light interferometry, and a scanning electron microscope. The results were analysed in terms of tribological processes (wear mechanisms) occurring in the friction pair consisting of the polymer socket and the metal head of a hip joint endoprosthesis.
Źródło:
Tribologia; 2015, 6; 81-92
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Postural stability and functional disorders in patients with loosened hip prosthesis
Autorzy:
Drzał-Grabiec, Justyna
Truszczyńska-Baszak, Aleksandra
Tarnowski, Adam
Powiązania:
https://bibliotekanauki.pl/articles/306972.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
postural stability
hip prosthesis loosening
balance disorders
stabilność postawy
endoproteza
zaburzenia równowagi
Opis:
The number of primary hip arthroplasties is growing every year. One of the most common long complications is the aseptic loosening of the prosthesis leading to serious complications in patients life, pain and following surgeries. In the literature, there is a lack of studies regarding balance impairment in this group of patients, which is why there was a need to conduct the study in order to find possible falling risk factors and simple functional, diagnostic test. The aim of the study was to assess functional state and static balance disorders in patients admitted to orthopaedic department due to loosened hip prosthesis prior to its replacement or removal. Methods: The study population were 30 patients (15 women and 15 men) admitted to Orthopaedic Department for diagnosis and treatment of loosened hip prosthesis. Patients’ mean age was 71.67 ± 9.21, body height 169.20 ± 8.75 cm, body weight 77.83 ± 12.96 kg. The clinical control group consisted of 30 healthy subjects age-, body height- and weight-matched, without degenerative disorders of lower extremities. Function was assessed with Harris Hip score. The static balance test was conducted in the mornings, in quiet separate room on bi-modular stabilometric platform CQStab2P, registering the movement of centre of foot pressure (COP). Results: Measurements with eyes open and closed showed significant differences in limb loads – the load to the healthy limb was several times greater. Results of tests on the platform with eyes closed showed significantly worse balance in patients group. Their total statokinesiogram path was longer, and their COP sways number was greater. Similarly to the test with eyes open, the load of the healthy limb was much greater. Conclusion: Hip replacement loosening results in significant worsening of balance parameters. Balance assessment could be an additional useful diagnostic tool for hip replacement loosening available for physiotherapists.
Źródło:
Acta of Bioengineering and Biomechanics; 2020, 22, 1; 41-46
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prototype of innovating bone tissue preserving THRA endoprosthesis with multi-spiked connecting scaffold manufactured in selective laser melting technology
Autorzy:
Uklejewski, R.
Rogala, P.
Winiecki, M.
Mielniczuk, J.
Powiązania:
https://bibliotekanauki.pl/articles/284792.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
tkanka kostna
endoproteza THRA
SLM
bone tissue
THRA endoprosthesis
selective laser melting
Opis:
The paper presents the prototype of innovating bone tissue preserving THRA endoprosthesis with multi-spiked connecting scaffold - the main result of our research project: "Experimental investigation and design of the constructional properties of bone-porous implants fixations" (4T07C05629, Polish Ministry of Science, finished in February 2008) presented also as plenary lecture at the 18th International Conference "Biomaterials in Medicine and Veterinary Medicine" in Rytro (Poland), 2008. Three-dimensional selective laser melting (SLM), a direct metal manufacturing (DMM) technology from rapid prototyping/rapid manufacturing (PR/RM) group, was successfully applied to manufacture these prototypes of Ti6AI7Nb powder. We share our observations and remarks on the prototypes manufacturing in SLM laser additive technology.
Źródło:
Engineering of Biomaterials; 2009, 12, 87; 2-6
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena rozwiązania konstrukcyjnego implantowanej endoprotezy stawu biodrowego
Estimation of constructional solution of implanted hip joint endoprosthesis
Autorzy:
Dąbrowski, M
Pawlikowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/99155.pdf
Data publikacji:
2008
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
biomechanika
implant ortopedyczny
endoproteza stawu biodrowego
obciążenie
biomechanics
orthopedic implant
hip endoprosthesis
load
Opis:
W pracy badaniu poddano endoprotezę stawu biodrowego, która uległa zniszczeniu po kilkuletnim okresie od wszczepienia. Zakres badań obejmował etapy trójwymiarowego modelowania układu trzpień-główka, ze szczególnym uwzględnieniem osadzenia gniazda w główce endoprotezy oraz ocenę wytrzymałościową konstrukcji z rozpatrywaniem warunków obciążenia. Przeprowadzono symulacje numeryczne pól naprężeń i odkształceń z oceną dopuszczalnych obciążeń celem weryfikacji poprawności rozwiązania.
The objective of the study was to determine the reasons of endoprosthesis failure after several years since implantation. The range of the investigation included 3D modelling of endoprosthesis and femur and numerical simulation of stress-strain fields in the bone-endoprosthesis system. In the paper special emphasis was put on specific construction of the endoprosthesis head and on estimation of its construction strength. Numerical simulations of stress-strain fields in the endoprosthesis were done to assess correctness of the construction.
Źródło:
Aktualne Problemy Biomechaniki; 2008, 2; 31-36
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies