Tytuł:
Assessment of thermal comfort in a lecture hall with the application of instruments for computational fluid dynamics
Autorzy:
Skotnicka-Siepsiak, A.
Powiązania:
https://bibliotekanauki.pl/articles/950453.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie
Tematy:
thermal comfort
air division
air conditioning
Opis:
The examinations presented in this article aim at illustrating some possibilities of applying instruments for computational fluid dynamics to assess thermal comfort on the example of a lecture hall in the building of the Institute of Building Engineering at the University of Warmia and Mazury in Olsztyn. The obtained results have been subjected to an analysis according to the guidelines provided in the PN-EN ISO 7730:2006 norm. For the air heating system used in the hall, the distributions of velocity, temperature, as well as the PMV and PDD indices have been subjected to an analysis, with a particular focus on the optimal temperature of the air inflow.
Źródło:
Technical Sciences / University of Warmia and Mazury in Olsztyn; 2016, 19(1); 41-58
1505-4675
2083-4527
Pojawia się w:
Technical Sciences / University of Warmia and Mazury in Olsztyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Air conditioning systems in data center
Autorzy:
Grzebielec, Andrzej
Kłos, Natalia
Powiązania:
https://bibliotekanauki.pl/articles/132006.pdf
Data publikacji:
2020
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
air conditioning
datacenter
energy efficiency
Opis:
Data center cooling is a specific issue. High heat flux density and maintaining rigorous operating conditions require suitable cold from the cooling system. The article lists the most common methods of data center cooling and classification of technological systems in data center facilities.
Źródło:
Modern Engineering; 2020, 1; 26-37
2450-5501
Pojawia się w:
Modern Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microbial Air Quality in Municipal Buses Before and After Disinfection of their Air-Conditioning Systems
Autorzy:
Gołofit-Szymczak, Małgorzata
Stobnicka-Kupiec, Agata
Górny, Rafał L.
Cyprowski, Marcin
Ławniczek-Wałczyk, Anna
Powiązania:
https://bibliotekanauki.pl/articles/123259.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
buses
air-conditioning system
bioaerosol
bacteria
fungi
Opis:
To ensure the proper quality of the air and simultaneously improve the comfort of professional drivers or travellers, the cars are fit with air-conditioning (AC) systems. The AC installations, however, quite often create suitable conditions for the development of microbiological agents and become an active emission source of harmful bioaerosols. This study was carried out in 6 municipal buses in large city located in central Poland. In studied vehicles, ozonisation or manual application of chemical disinfectant in a spray form were used for disinfection of AC bus systems. The concentrations of bacteria and fungi in the air collected in buses before the service of their AC installations were 4.3×102 CFU/m3 and 2.4×102 CFU/m3, respectively. After AC service using both tested disinfection methods, the decrease in microbial concentrations in the air of municipal buses was observed. The highest effectiveness of AC cleaning was noted when the chemical disinfectant in a spray form was used. This study revealed that to eliminate microbiological contamination and, by that, decrease the exposure of both drivers and passengers to harmful microbial contaminants, the chemical disinfection of bus AC system should be performed at regular basis.
Źródło:
Journal of Ecological Engineering; 2019, 20, 10; 189-194
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Systemy klimatyzacji wyrobisk górniczych w polskich kopalniach
Air conditioning systems for mining excavations in polish coal mines
Autorzy:
Szlązak, Nikodem
Obracaj, Dariusz
Swolkień, Justyna
Powiązania:
https://bibliotekanauki.pl/articles/164224.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Górnictwa
Tematy:
zagrożenie klimatyczne
klimatyzacja
metody klimatyzacji
efektywność systemu klimatyzacji
climate hazard
air condition
methods of air conditioning
efficiency of air-conditioning systems
Opis:
W wyrobiskach podziemnych, którymi przepływa powietrze występują naturalne i technologiczne źródła dopływu strumienia ciepła. W wyniku tego notuje się w nich wysokie temperatury, co po uwzględnieniu równie wysokiej wilgotności powietrza, powoduje znaczne pogorszenie warunków klimatycznych. Skutkuje to pogorszeniem takich funkcji organizmu człowieka jak: zdolność percepcji, koncentracji, uwagi, spostrzegawczości. Ten niekorzystny wpływ temperatury i wilgotności na organizm ludzki określamy pojęciem zagrożenia klimatycznego. Problematyka poprawy warunków klimatycznych w wyrobiskach górniczych stanowiła istotną dziedzinę działalności naukowej pracowników Wydziału Górnictwa i Geoinżynierii Akademii Górniczo-Hutniczej w Krakowie. Aktualnie problemy związane z projektowaniem przewietrzania i klimatyzacji wyrobisk w kopalniach podziemnych nabierają coraz większego znaczenia z uwagi na zwiększającą się głębokość prowadzenia robót górniczych. Właściwe zaprojektowanie klimatyzacji powinno zapewnić jak największą efektywność wykorzystania mocy chłodniczej w wyrobiskach górniczych. Dlatego też w artykule przedstawiono, na podstawie przeprowadzonych pomiarów, efektywność wykorzystania zabudowanej mocy chłodniczej oraz przedstawiono czynniki wpływające na jakość uzyskiwanych parametrów pracy instalacji klimatyzacyjnych. W końcowej części artykułu podano czynniki, które mogą przyczynić się do wzrostu efektywności klimatyzacji.
In underground excavations with airflow the natural and technological sources of heat stream inflow occur. As a result, high temperatures occur in underground excavations, which, after taking into account equally high humidity, causes significant deterioration of climatic conditions. This causes a decrease in such functions of the human body as the ability to perceive, concentrate, attention, and perceptiveness. We refer to this adverse effect of temperature and humidity on the human body as climate hazard. The issue of improving climatic conditions in mining excavations was an important area of scientific activity of employees of the Faculty of Mining and Geoengineering of the AGH University of Science and Technology in Krakow. Currently, problems related to the design of ventilation and air conditioning of excavations in underground mines are becoming increasingly important due to the increasing depth of mining works. Proper designing of air conditioning should ensure the greatest efficiency in the use of cooling power in mining excavations. Therefore, the article presents, based on the measurements carried out, the effectiveness of the use of built-in cooling power and presents factors affecting the quality of the obtained parameters of air conditioning systems. The final part of the article lists the factors that can contribute to the increase in the efficiency of air conditioning.
Źródło:
Przegląd Górniczy; 2019, 75, 11; 23-33
0033-216X
Pojawia się w:
Przegląd Górniczy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Projektowanie systemów klimatyzacji kopalń przy zastosowaniu programu KlimaSystem
Designing mine cooling systems using KlimaSystem software
Autorzy:
Szlązak, N.
Obracaj, D.
Korzec, M.
Swolkień, J.
Powiązania:
https://bibliotekanauki.pl/articles/113716.pdf
Data publikacji:
2018
Wydawca:
STE GROUP
Tematy:
projektowanie
systemy klimatyzacyjne
KlimaSystem
design
air conditioning systems
Opis:
W polskich kopalniach podziemnych stosowane są różne systemy klimatyzacji. Zwiększająca się głębokość eksploatacji, a co za tym idzie pogarszające się warunki klimatyczne będą wymagały dalszego ich stosowania. Skuteczność działania systemu zależy od poprawnego jego zaprojektowania. Równie istotna jest także jego bieżąca obsługa. Efekt chłodzenia powietrza w rejonach prowadzonych robót jest możliwy do uzyskania tylko przy zapewnieniu odpowiednich parametrów rozpływu i temperatury wody lodowej doprowadzanej do chłodnic. W przypadku ciągłej zmiany struktury sieci rurociągów dołowych jest to trudne do realizacji. Prowadzenie obliczeń w skomplikowanych sieciach jest utrudnione. Pomocne w takim przypadku może być zastosowanie programu komputerowego, jakim jest program KlimaSystem.
In the Polish underground mines different types of mine cooling systems are used. In the future, parameters of air climate conditions is going to be worse, so using air cooling systems will be required. The effectiveness of the system depends not only on the correct design. Very important is also current service. Efecivness of air cooling system depends of many factors. But key influence have distribution of water. To air coolers should be delivered enough cold wather. When the structure of mine cooling system is complicated it could be difficult. Then for calculations might be used computer software, like a KlimaSystem.
Źródło:
Systemy Wspomagania w Inżynierii Produkcji; 2018, 7, 1; 377-393
2391-9361
Pojawia się w:
Systemy Wspomagania w Inżynierii Produkcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie różnych systemów chłodniczych w analizowanym obiekcie hotelowym – wskaźniki ekonomiczne
Comparison of the various air-conditioning systems in analysed hotel spaces – economics indices
Autorzy:
Gładyszewska-Fiedoruk, K.
Manowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/402615.pdf
Data publikacji:
2014
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
klimatyzacja
freon
woda lodowa
air conditioning
ice water
Opis:
W pracy przedstawiono koszty inwestycyjne i eksploatacyjne wybranych systemów chłodniczych w różnym okresie życia układów oraz czas zwrotu inwestycji. Porównując zaprezentowane w wymienionym artykule układy należy zauważyć przewagę systemu opartego na bezpośrednim odparowaniu czynnika chłodniczego w przypadku każdego z trybów pracy (cyklu grzania, chłodzenia oraz cyklu mieszanego – grzania i chłodzenia). Pewnym zaskoczeniem są niższe koszty ogrzewania za pomocą systemu freonowego, ponieważ wydawałoby się że ciepło sieciowe w połączeniu z wodą lodową będzie tańsze. Różnica w kosztach inwestycyjnych prezentowanych układów klimatyzacji w obiekcie biurowym dochodzi do 100%. Najniższe koszty inwestycyjne ma układ z wodą lodową. Można zauważyć, że na przestrzeni 15 lat, czyli czasu przyjmowanego jako czas „życia” produktu, oszczędności mogą wynieść od 500 tysięcy do 1 milion złotych w wypadku wybrania systemu freonowego dla tego samego obiektu.
The paper focuses on the investment costs and operating costs at different life systems and time. Return on investment have been shown too. By comparing the settings, it should be noted the advantage of a system based on direct evaporation of the refrigerant in the case of each of the operating modes. A surprise is lower heating cost by using freon system, because it would seem that the heat, combined with the ice water network will be cheaper. The difference in investment costs of presents systems comes to 100%. The lowest investment cost has stated for system with ice water. It can be observed that over 15 years, i.e. time necessary as a time of "life" of the product savings could amount from 500 thousand to $ 1 million in the case of freon system for the same object.
Źródło:
Budownictwo i Inżynieria Środowiska; 2014, 5, 3; 97-100
2081-3279
Pojawia się w:
Budownictwo i Inżynieria Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Innovation model for energy effective investigations of air conditioning systems for cleanrooms
Autorzy:
Labay, V.
Harasym, D.
Powiązania:
https://bibliotekanauki.pl/articles/410772.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Oddział w Lublinie PAN
Tematy:
exergy balance
air conditioning systems
cleanrooms
energy efficiency
Opis:
Innovation mathematical research model of the central straight flow air conditioning system for cleanroom in order to computer’s estimation its energy effective by virtue of exergetic output-input ratio depending on different factors, which have influence on its work, was presented in this article. The dependence of exergetic output-input ratio for chosen air conditioning system on parameters of external air was defined thanks to this model.
Źródło:
ECONTECHMOD : An International Quarterly Journal on Economics of Technology and Modelling Processes; 2014, 3, 2; 47-52
2084-5715
Pojawia się w:
ECONTECHMOD : An International Quarterly Journal on Economics of Technology and Modelling Processes
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal analysis of car air cooler
Autorzy:
Trzebiński, D.
Szczygieł, I.
Powiązania:
https://bibliotekanauki.pl/articles/242031.pdf
Data publikacji:
2011
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
car air conditioning
refrigerant
thermal comfort
thermodynamic cycle
Opis:
People more and more time spend in vehicles (cars, trains, planes, buses or subway). This is the reason why the thermal comfort has more and more paid attention. In one hand people try to make comfort (in each situation) whatever they are at home, office or in car. In the other hand the thermal conditions in the cabin of vehicles directly influences on the driver's and passengers safety. The investigations presented in this paper are the part of larger project, which assumes complex modelling of thermal state of car interior. First part assumes creation of CFD model of car interior. Second part is thermodynamic modelling of air cooling unit in order to estimate the influence of basic cabin parameters on the A/C unit COP, power consumption of the unit and fuel consumption of the vehicle. In the paper thermodynamic analysis of car air cooler is presented. Typical refrigerator cycles are studied: one with uncontrolled orifice and non controlled compressor, second with thermostatic controlled expansion valve and externally controlled compressor. The influence of refrigerant charge and the inlet air temperature on the coefficient of performance, exergy efficiency, heat flux and temperature in evaporator and compressor net power were investigated. The impact of improper refrigerant charge on the performance of A/C systems was also checked.
Źródło:
Journal of KONES; 2011, 18, 2; 439-446
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The analysis of possible methods of providing fresh water for sailing vessels based on the example of s/v Dar Młodzieży
Autorzy:
Giernalczyk, M.
Herdzik, P.
Powiązania:
https://bibliotekanauki.pl/articles/242535.pdf
Data publikacji:
2013
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
sailing vessel
air conditioning system
vaporizer
osmotic desalinator
Opis:
In this paper the possibilities of providing fresh water for sailing vessels based on the example of s/v Dar Modziey are presented. Different methods of obtaining fresh water such as rainwater harvesting, replenishing water tanks at harbours, collecting condensed water from air conditioning systems or producing fresh water from seawater by means of desalination equipment were considered. Vacuum vaporizers (heated by fresh water used as a cooling medium of the main propulsion engines) and osmotic desalinators (using the phenomenon of reverse osmosis) were being taken under consideration. Special focus was put on the quality of water obtained; comparing the methods mentioned and pursuing the best solution both in technical and economic terms. The choice of desalinators was preceded by the analysis of quantity and configuration of pumps and membranes that will guarantee optimum performance. Selection of the manufacturer was determined by costs of purchase, costs of operation and the availability of spare parts and consumables. The osmotic desalinator ended up as the final choice of fresh water producing device on s/v Dar Modziey. Excessive water consumption can be satisfied by replenishing supplies at ports. The paper is concluded with comments and suggestions that can be adapted by a ship owner as a solution for the problem of supplying vessels with fresh water.
Źródło:
Journal of KONES; 2013, 20, 1; 95-102
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energochłonność systemów wytwarzania chłodu w obiektach hotelowych
Energy consumption of the cool generation systems in the hotel facilities
Autorzy:
Ruciński, Adam
Powiązania:
https://bibliotekanauki.pl/articles/111025.pdf
Data publikacji:
2019
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
klimatyzacja
hotel
bilans cieplny
air-conditioning
heat balance
Opis:
W pracy przedstawiono ogólną charakterystykę zużycia energii w branży hotelowej na świecie i w Europie. Podano projektowe i rzeczywiste wielkości zużycia energii służące do pokrycia zapotrzebowania na chłód w wybranych hotelach. Wskazano technologie i procedury postępowania potrzebne do obniżenia wykorzystywania energii ze źródeł nieodnawialnych. Następnie przedstawiono rozważane obecnie perspektywiczne technologie chłodnicze do zastosowania w następnych 10 – 20 latach. W pracy podkreślono potrzebę ograniczenia energochłonności instalacji chłodniczych i klimatyzacyjnych ze względu na ochronę środowiska i czystość atmosfery. Bezpośrednio determinuje to dalszy rozwój branży hotelarskiej w postaci nowoczesnych i nowatorskich rozwiązań.
The paper presents the general characteristics of energy consumption in the hotel industry all over the world and in Europe. The design and actual energy consumption needed for cold production in selected hotels is presented. Technologies and procedures necessary to reduce the use of fossil fuels are indicated. Then, the future cooling technologies currently under consideration are presented for use in the next 10 -20 years. The work underlined the need to reduce the energy consumption of refrigeration and air-conditioning installations due to environmental protection and the purity of the atmosphere. This directly determines the further development of the hotel industry in the form of modern and innovative solutions.
Źródło:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych; 2019, 3
2450-1859
2450-8721
Pojawia się w:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research to estimate energy efficiency of a ventilation and air conditioning heat pump system inside a production premise with ventilation air recovery
Autorzy:
Bezrodny, Myhailo Kostiantynovych
Misiura, Tymofii Oleksiyovych
Powiązania:
https://bibliotekanauki.pl/articles/1955060.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
air conditioning
heat pump system
refrigeration efficiency
recuperation
Opis:
The research provides a thermodynamic analysis of the theoretical model of a ventilation and air conditioning heat pump system with the ventilation air cold energy recovery depending on outside air parameters, the recovery efficiency and characteristics of a premise. A confectionery production workshop was taken as a prototype where technological conditions (temperature and humidity) must be maintained during the warm season. Calculations using the method of successive approximations to estimate air parameters at system’s nodal points were conducted. It allowed to determine theoretical refrigeration efficiency of the studied system and proved advantages of heat recuperation for smaller energy consumption. The model can be applied for design of heating, ventilation, and air conditioning units which work as a heat pump. The studied system has the highest energy efficiency in the area of relatively low environment temperatures and relative humidity which is suitable for countries with temperate continental climates characterized by low relative humidity.
Źródło:
Archives of Thermodynamics; 2021, 42, 4; 69-86
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal analysis of car air conditioning
Autorzy:
Trzebiński, D.
Szczygieł, I.
Powiązania:
https://bibliotekanauki.pl/articles/239964.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
analiza termiczna
HVAC
klimatyzacja
air conditioning
thermal analysis
Opis:
Thermodynamic analysis of car air cooler is presented in this paper. Typical refrigerator cycles are studied. The first: with uncontrolled orifice and non controlled compressor and the second one with the thermostatic controlled expansion valve and externally controlled compressor. The influence of the refrigerant decrease and the change of the air temperature which gets to exchangers on the refrigeration efficiency of the system; was analysed. Also, its effectiveness and the power required to drive the compressor were investigated. The impact of improper refrigerant charge on the performance of air conditioning systems was also checked.
Źródło:
Archives of Thermodynamics; 2010, 31, 4; 71-80
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena skuteczności klimatyzacji wyrobisk górniczych w kopalniach węgla kamiennego
Effectiveness of air conditioning systems in coal mines
Autorzy:
Szlązak, N.
Obracaj, D.
Swolkień, J.
Powiązania:
https://bibliotekanauki.pl/articles/113311.pdf
Data publikacji:
2016
Wydawca:
STE GROUP
Tematy:
zagrożenie klimatyczne
metody klimatyzacji wyrobisk podziemnych
efektywność działania klimatyzacji
climatic hazard
underground air conditioning system
effectiveness of air conditioning system
Opis:
Zapewnienie stabilnych w czasie parametrów mikroklimatu drogą wentylacji wyrobisk jest trudne do uzyskania. W najbliższej przyszłości należy się liczyć z dalszym pogarszaniem się warunków klimatycznych w polskich kopalniach w wyniku zwiększenia koncentracji wydobycia oraz schodzenia z eksploatacją na głębsze poziomy. Celem niniejszego artykułu jest przedstawienie stosowanych metod zwalczania zagrożenia klimatycznego w górnictwie polskim oraz wskazanie na skuteczność pracy urządzeń. W wyrobiskach podziemnych, którymi przepływa powietrze występują naturalne i technologiczne źródła dopływu strumienia ciepła. Wysoka temperatura i równie wysoka wilgotność powietrza prowadzą do pogorszenia warunków klimatycznych. Coraz większego znaczenia nabierają zatem problemy związane z projektowaniem przewietrzania i klimatyzacji wyrobisk w kopalniach podziemnych.
It is difficult to ensure stable parameters of microclimate by means of ventilation and air-conditioning in underground excavations. In the nearest future a further deterioration in ther-mal hazard in Polish coal mines can be expected as a result of mining at deeper and deeper levels. The aim of this article is to present used methods of climatic conditions control and to indicate errors in design. There are natural and technological heat flux sources in mine airways. High air temperature and humidity lead to worse climatic conditions. It results in slowing down some functions of a human organism, such as perception, concentration and attention. This unfavorable effect of air temperature and humidity on human body is known as thermal hazard. Problems connected with design of ventilation and cooling systems in underground mines are becoming more and more important.
Źródło:
Systemy Wspomagania w Inżynierii Produkcji; 2016, 1 (13); 202-216
2391-9361
Pojawia się w:
Systemy Wspomagania w Inżynierii Produkcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The analysis of thermal comfort in the school and the wedding house
Analiza komfortu cieplnego w szkole i domu weselnym
Autorzy:
Zender-Świercz, E.
Jędrzejczyk, O.
Kaczorowska, K.
Powiązania:
https://bibliotekanauki.pl/articles/402185.pdf
Data publikacji:
2018
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
thermal comfort
air conditioning
simulation
komfort termiczny
klimatyzacja
symulacje
Opis:
The environment, where people are staying, should provide thermal comfort. It means that the equilibrium of the amount of heat produced in the human body and the amount of heat lost to the environment should be kept. To achieve the suitable conditions of air there the air conditioning, ventilation and heating systems are used. These systems regulate the air parameters and maintain them at the desired level. Designers locate, most commonly, the supply units of air conditioning systems in the ceiling in the central part of the room or near the windows without taking into account the specificity of the premises. However, such an approach may contribute to the lack of thermal comfort. The sensation of air is a very subjective indicator that depends on many variables. The authors of the article made an attempt to analyze the influence of the type of air conditioning system and location of air supply units on the thermal comfort in rooms of different use.
Środowisko, w którym przebywa człowiek powinno zapewniać odczuwanie komfortu. tzn. powinna być zachowana równowaga pomiędzy ilością ciepła wytwarzanego w ciele człowieka a ilością ciepła traconego do otoczenia. Aby uzyskać taki stan powietrza w pomieszczeniach, stosuje się różne systemy wentylacji, klimatyzacji i ogrzewania. Układy te regulują parametry powietrza i utrzymują je na żądanym poziomie. Projektanci lokalizują elementy nawiewne instalacji klimatyzacji najczęściej w suficie w centralnej części pomieszczenia lub przy oknach bez uwzględniania specyfiki pomieszczenia. Jednak takie spojrzenie na instalację może przyczynić się do braku warunków komfortu cieplnego. Postrzeganie stanu powietrza jest bardzo subiektywnym wskaźnikiem zależnym od wielu zmiennych. W artykule podjęto próbę analizy wpływu rodzaju instalacji klimatyzacji oraz rozmieszczenia elementów nawiewnych w pomieszczeniach o różnym przeznaczeniu.
Źródło:
Structure and Environment; 2018, 10, 1; 75-81
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka wybranych systemów chłodniczych w pomieszczeniach hotelowych
Characteristics of chosen air-conditioning systems in the hotel space
Autorzy:
Gładyszewska-Fiedoruk, K.
Manowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/403165.pdf
Data publikacji:
2014
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
klimatyzacja
freon
woda lodowa
air conditioning systems
water ice
Opis:
W artykule porównano dwa układy klimatyzacji, różniące się między sobą zasadą działania, ale przede wszystkim oparte o dwa różne czynniki robocze: freon i wodę lodową. Obydwa rozwiązania przeszły długą drogę rozwoju i prezentują w chwili obecnej wysoki poziom technologiczny. Rodzi się więc pytanie – który z nich jest lepszy? Tradycja, czy nowoczesność? Czy systemy oparte na dwóch różnych czynnikach mogą istnieć obok siebie, czy – zgodnie z zasadą: „lepsze jest wrogiem dobrego” – będziemy mieli do czynienia z stopniowym wypieraniem jednego z nich z rynku. Analiza porównawcza parametrów eksploatacyjnych obu układów będzie próbą odpowiedzi na to pytanie. W artykule zebrano informacje dotyczące układów z bezpośrednim i pośrednim odparowaniem czynnika chłodniczego. Przedstawiono dane projektowe: koncepcje, dobór urządzeń i ich szczegółowe porównanie.
The paper compares two types of air conditioning systems with differing principle of action-i.e. and using various factors: working freon and water ice. Both solutions have passed a long way of development and represent the currently high level of technology. So the question becomes – which one is better? Tradition or modernity? The systems can exist next to each other, or can be seen a gradual supersession one of them from the market. Comparative analysis of performance parameters of both circuits will attempt to answer this question. The paper includes information about systems with direct and indirect desiccation of the refrigerant. Design data: concepts, selection of equipment and their detailed comparison, were presented.
Źródło:
Budownictwo i Inżynieria Środowiska; 2014, 5, 1; 7-13
2081-3279
Pojawia się w:
Budownictwo i Inżynieria Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies