Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "measuring process" wg kryterium: Wszystkie pola


Tytuł:
Measuring Process via Sampling of Signals, and Functions with Attributes
Autorzy:
Borys, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/226048.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
measuring process
sampling of signals
functions with attributes
Dirichlet function
Opis:
In this paper, it has been shown that any measuring process can be modeled as a process of sampling of signals. Also, a notion of a special kind of functions, called here functions with attributes, has been introduced. The starting point here, in the first of the above themes, is an observation that in fact we are not able to measure and record truly continuously in time any physical quantity. The measuring process can be viewed as going stepwise that is in steps from one instant to another, similarly as a sampling of signals proceeds. Therefore, it can be modeled as the latter one. We discuss this in more detail here. And, the notion of functions with attributes, we introduced here, follows in a natural way from the interpretation of both the measuring process as well as the sampling of signals that we present in this paper. It turns out to be useful.
Źródło:
International Journal of Electronics and Telecommunications; 2020, 66, 2; 309-314
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Further Discussion on Modeling of Measuring Process via Sampling of Signals
Autorzy:
Borys, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/226039.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
measuring process
sampling of signals
smearing of signal samples
averaging of signal samples
Opis:
In this paper, we continue a topic of modeling measuring processes by perceiving them as a kind of signal sampling. And, in this respect, note that an ideal model was developed in a previous work. Whereas here, we present its nonideal version. This extended model takes into account an effect, which is called averaging of a measured signal. And, we show here that it is similar to smearing of signal samples arising in nonideal signal sampling. Furthermore, we demonstrate in this paper that signal averaging and signal smearing mean principally the same, under the conditions given. So, they can be modeled in the same way. A thorough analysis of errors related to the signal averaging in a measuring process is given and illustrated with equivalent schemes of the relationships derived. Furthermore, the results obtained are compared with the corresponding ones that were achieved analyzing amplitude quantization effects of sampled signals used in digital techniques. Also, we show here that modeling of errors related to signal averaging through the so-called quantization noise, assumed to be a uniform distributed random signal, is rather a bad choice. In this paper, an upper bound for the above error is derived. Moreover, conditions for occurrence of hidden aliasing effects in a measured signal are given.
Źródło:
International Journal of Electronics and Telecommunications; 2020, 66, 3; 507-513
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Światło białe jako medium w pomiarze temperatury
Visible light in temperature measuring process
Autorzy:
Śmierzalski, D.
Różański, L.
Powiązania:
https://bibliotekanauki.pl/articles/155915.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
temperatura
pomiar
światłowód
temperature
measurement
fiber optic
Opis:
W artykule opisano szczególną aplikację termometru światłowodowego w warunkach produkcyjnych. Weryfikację dokładności i czasu reakcji sondy na wymuszenie poprzedzają podstawy termometrii tego rodzaju. Wnioski dotyczą możliwości stosowania tej rzadko spotykanej metody wraz z komentarzem parametrów technicznych urządzeń i wskazaniem potencjalnych aplikacji.
Visible light, considered as an electromagnetic wave of 400 - 700 nm length, is becoming a useful medium in measuring techniques dominated by contact and non-contact systems based on infrared radiation emission. The first part of this paper describes the method (Fig. 1) and its basics [1, 2, 8] as well as the system classification [6, 7]. There are presented some fiber-optic thermometers [3, 4, 5] and available sensors (Fig. 2) as well as the possibility of signal capture from many sources. The measurement accuracy was verified (Figs. 3, 4, 5), then the method usefulness was characterized when considering hard industry conditions, in which specific points are hard to reach and electromagnetic fields may occur. Finally, a laboratory experiment was carried out and its results were compared with those obtained from a real industry application (6), located in a factory of the Polish inductive plates producer. The project assumed temperature measurement in situ during heating and this postulate was achieved thanks to the producer kindness. The next part refers to other possibilities that measuring instruments based on fiber optic technique can offer [9]. Efforts were con-centrated on those fields In which other devices cannot be used, just to show the unique character of the process based on visible light. The conclusion presents some plans for the future research on fiber optic measuring technique. Its weaknesses are described as points for elimination. There is also emphasized the useful character of those system. The possible field of application is shown.
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 1, 1; 23-26
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of measuring process properties on phosphate rock slurry rheology based on Brookfield method
Autorzy:
Chen, Aoao
Zhang, Qin
Powiązania:
https://bibliotekanauki.pl/articles/2175436.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
phosphate rock
grinding
concentration
rheological properties
apparent viscosity
Opis:
This research aims to explore how the flotation process conditions influence the rheological properties of phosphate rock slurry. The apparent viscosity of phosphate rock slurry was measured by Brookfield DVNext rheometer. Different mineral types, grinding time, slurry mass concentration and reagent systems were adopted to study the viscosity behavior of phosphate rock slurry. The results showed that under the same conditions, the apparent viscosity of apatite and dolomite slurry was basically the same, and the apparent viscosity of the slurry after mixing the two minerals was basically the same as that of single mineral. For the same slurry concentration, the mineral particle size had a significant effect on the rheological behavior of the slurry, and its apparent viscosity increased exponentially with the decrease of particle size. In addition, phosphate rock slurry showed shear thickening fluids characteristics when the slurry concentration is 20%-40%, but changed to pseudoplastic fluid at high concentration (60%). Sulfuric acid as pH regulator and inhibitor had little effect on the rheology of slurry; when GJBW and NaOL were added as collectors, the rheology of slurry changed, and the effect of GJBW was more obvious.
Źródło:
Physicochemical Problems of Mineral Processing; 2022, 58, 6; art. no. 156202
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uwagi o opracowaniu pomiarów deformacji dynamicznych, szybkozmiennych realizowanych metodami stereofotogrametrii z wykorzystaniem kamer CCD
Some consideration on fast variable deformation measuring process performed by movie stereophotogrammetry methods
Autorzy:
Jankowicz, B.
Powiązania:
https://bibliotekanauki.pl/articles/130844.pdf
Data publikacji:
2001
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
deformacje dynamiczne szybkozmienne
stereofotogrametria
kamera CCD
fast variable deformation
stereophotogrammetry
CCD camera
Opis:
Przedstawione w artykule rozważania dotyczą pomiaru deformacji dynamicznych - szybkozmiennych tj. o szybkim przebiegu w czasie rzeczywistym - metodami stereofotogrametrii filmowej z zastosowaniem kamery filmowej CCD wyposażonej w nasadką stereoskopową. Głównym celem przeprowadzonych badań była optymalizacja konfiguracji aparatury pomiarowej wraz z oceną przydatności autografu cyfrowego VSD dla powyższego zadania. Badania przeprowadzono na przykładzie pomiaru deformacji niewielkich rozmiarów blachy aluminiowej, na którą działała siła w sposób przypadkowy. Rejestracji dokonano kamerą filmową CCD z nasadką stereoskopową. Następnie po transformacji kolejnych, „zamrożonych” obrazów filmowych do postaci cyfrowej otrzymano obrazy (parą stereoskopową) nadające sią do dalszej obróbki na autografie cyfrowym VSD, przy czym każdemu z nich przyporządkowana była czwarta współrzędna czasowa według wskazań chronometru.
This project aim to designation principles of fast variable deformation measuring by photogrammetrics methods, particularly measuring by movie CCD camera with stereoscopic unit. Optimalization of measuring devices configuration and Video Stereo Digitizer estimation for this task - it’s the main problem of the project. Designed by movie - stereophotogrammetry images were transformed to the digital images and the next elaborated on the Video-Stereo-Digitizer - on the chronological order - according to high accuracy chronometer. In this way were receiving 4-dimensional image of deformation variation in the real time. Video Stereo Digitizer is good for fast variable deformation measuring process, recorded by movie CCD camera with stereoscopic unit because accuracy and application conditions are performed.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2001, 11; 5-51-5-54
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measuring methods of welding process parameters
Autorzy:
Brydak, K.
Szlachta, A.
Powiązania:
https://bibliotekanauki.pl/articles/114506.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
Rogowski coil
welding current measurement
data acquisition card
LabVIEW environment
Opis:
The paper focuses on the problems of monitoring the resistance spot welding process of thin metal sheets used in aircraft structures. The welding process is conducted using welders with software control which allows the welding cycle to be established. Essential parameters in the welding process include: electrode profiles, establishing electrode force as well as the shape and the intensity of the current heating the weld. The paper proposes using a measurement system which registers the above-mentioned welding process parameters and utilises the modules of data acquisition, series NI 9215 operating in a set with NI cDAQ-9178. Software which uses the LabVIEW environment was implemented into the measurement system. The measurement of the welding current intensity was made using a Rogowski coil, while other measurement signals were obtained from the diagnostic interface of the programmable controller of the welder. The paper presents preliminary results of the research. The objective of the initial research is the preparation of a calibration method of welder measurement systems.
Źródło:
Measurement Automation Monitoring; 2016, 62, 1; 26-28
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
AN ATTEMPT AT MEASURING THE DEAGRARIANISATION PROCESS OF POLISH RURAL AREAS AT NUTS4 LEVEL
Autorzy:
Klimanek, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/453587.pdf
Data publikacji:
2013
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Katedra Ekonometrii i Statystyki
Tematy:
deagrarianisation
rural areas
composite indicator
Opis:
Deagrarianisation is a complex concept, which denotes a declining economic significance of agriculture and agricultural production in society at large, and rural economy and society in particular. The article is an attempt at constructing a composite indicator of the process of deagrarianisation using variables obtained by official statistics. The proposed composite indicator of deagrarianisation is then used to assess the intensity of deagrarianisation of rural areas between 2002 and 2010 in NUTS4 units (Pol. powiat) of the province of Wielkopolska.
Źródło:
Metody Ilościowe w Badaniach Ekonomicznych; 2013, 14, 1; 243-252
2082-792X
Pojawia się w:
Metody Ilościowe w Badaniach Ekonomicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Colour analysing of IPA brewing phases, including daily measuring of the fermentation process
Autorzy:
Barczi, András
Szabó, Dorottya
Magyari, Péter
Géczi, Gábor
Powiązania:
https://bibliotekanauki.pl/articles/2172261.pdf
Data publikacji:
2022
Wydawca:
Państwowa Wyższa Szkoła Zawodowa w Tarnowie
Tematy:
brewing
color analysiation
IPA
wort
color measuring
piwowarstwo
analiza kolorystyczna
brzeczka
pomiar koloru
Opis:
Over the last decade, the brewing revolution has shown a new face to brewing. Besides the large-scale production, small-scale, artisanal hand crafted, and home breweries have also become important and relevant. This change has forced large-scale compa-nies to change their usual methods and brew other types of recipes as well.One of the most popular ALE-type beers is the Indian Pale Ale (IPA), which gives beer a fruity-citrus flavour due to its hop content. It is especially popular with novice brewers as it has no enormous machine requirements compared to LAGER-type beers.In the study, we made our already known and popular recipe, a New England IPA, in a 30-litre brewing pot. This type requires only one type of malt; however, we added barley flakes, oat flakes, and wheat flakes to enhance the flavour. Hops are very domi-nant in the taste of this type of beer, five of which were used during brewing and later at “dry hopping” during fermentation.Sampling was performed every minute during mashing, brewing, hopping, cooling, and yeasting with a calibrated NIX-type measuring device with repetition to avoid measurement errors. During the fermentation stage, the colour change was observed by daily sampling. The study aims to separate the stages of brewing by colour and identify the stages of the already known biological and chemical activities by colour. This study is the first part of a more extended series of experiments where we will perform similar experiments on several types of beer (LAGER, STOUT, APA, WHEAT, RED, etc.). We would also like to know about the possible effect of carbonisation on colour, the possible effect of storage in a bottle on colour, and possible deviations from a similar decoction.
Źródło:
Science, Technology and Innovation; 2022, 15, 1; 1--7
2544-9125
Pojawia się w:
Science, Technology and Innovation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling of physical phenomena in the vertical velocity measuring circuit for process of designing the SWPL-1 helmet-mounted display system
Autorzy:
Michalak, S.
Żyluk, A.
Szelmanowski, A.
Borowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/243481.pdf
Data publikacji:
2018
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
transport
avionics
helmet-mounted display systems
error
vertical velocity measurement
Opis:
The article presents the selected methods of identifying static and dynamic properties of the measuring paths to the extent necessary for the proper integration of on-board systems with the helmet-mounted flight parameter display system. It presents the methods of identifying static and dynamic properties of the WR-10MK on board variometer as one of more difficult identification elements. Its identification was carried out on the basis of the basic dependencies of the International Standard Atmosphere and the instruments construction’s parameters. It built a mathematical model describing the physical phenomena associated with vertical speed measurement. This model differs from the models found in the literature in terms of detail and description accuracy. On this basis, in the Simulink environment, it built a simulation model corresponding to its mathematical model. The non-linear model was the starting point for the construction of the linearized model based on the operator transmittance. The developed models were evaluated for errors of vertical speed’s dynamic indications. This allowed assessing the usefulness of the individual models for further works on ensuring the correlation of indications of the on-board variometer and the SWPL-1 helmet-mounted flight parameter display system. The presented simulation models include design details, as well as the characteristics of technological errors and disturbances of a stochastic nature. Another approach to the issue of identification is to use the characteristics provided by the manufacturer in the form of approximate characteristics of a module.
Źródło:
Journal of KONES; 2018, 25, 4; 277-284
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiarowo-kontrolny system zastosowany w procesie produkcji central do systemów alarmowych
Measuring system in process of production control panel for alarm systems
Autorzy:
Galla, S.
Powiązania:
https://bibliotekanauki.pl/articles/268494.pdf
Data publikacji:
2004
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Opis:
Przedstawiono strukturę funkcjonalną systemu pomiarowo-kontrolnego zastosowanego w procesie produkcji central do systemów alarmowych. Opisano szerzej stanowisko pomiarowo-kontrolne, które zostało zastosowane w systemie obiegu informacji w procesie wytwarzania urządzeń alarmowych o wysokiej jakości.
In the paper the structure of functional-check measuring system used in process of production panels for alarm systems is presented. Measuring-check system which has been used in system of circulation of information in high quality process of productions alarm systems panels is described.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2004, 20; 47-50
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selection of measuring equipment in assembly process - analysis of selected elements
Dobór wyposażenia pomiarowego w procesach montażowych - analiza wybranych elementów
Autorzy:
Jarysz-Kamińska, E.
Powiązania:
https://bibliotekanauki.pl/articles/327994.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
wyposażenie pomiarowe
właściwości metrologiczne
okrętowy układ napędowy
measuring equipment
metrological characteristics
ship propulsion system
Opis:
The paper presents function of selection of measuring equipment - DWP function. Analysis of the individual elements of described the function can be used for isolation the most important measurement components of the selection of measuring equipment for selected measurement processes. The paper shows one chosen element of function of selection of measuring equipment - metrological characteristics. Those characteristics are shown on the example of chosen measuring equipment which is used in the alignment deviation measurements carried out during the assembly of elements of the ships propulsion system.
W artykule przedstawiono funkcję doboru wyposażenia pomiarowego - funkcja DWP. Analiza poszczególnych elementów przedstawionej funkcji może służyć wyodrębnieniu najistotniejszych składników doboru wyposażenia pomiarowego dla wybranych zadań pomiarowych. W artykule zobrazowano jeden z elementów funkcji doboru wyposażenia pomiarowego - właściwości metrologiczne. Charakterystyki te przedstawiono na przykładzie wyposażenia pomiarowego wykorzystywanego w trakcie pomiarów odchyłki współosiowości realizowanych w trakcie montażu elementów okrętowego układu napędowego.
Źródło:
Diagnostyka; 2011, 3(59); 47-52
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koncepcja i analiza sensora/aktuatora piezoelektrycznego do pomiaru procesu starzenia się ludzkiej skóry
Design and Analysis of a Piezoelectric Resonant Sensor/Actuator for Measuring the Aging Process of Human Skin
Autorzy:
Sienkiewicz, Ł.
Rouchon, J.-F.
Ronkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/1368731.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
impedancja elektromechaniczna
piezoelektryczność
sensor/aktuator
electromechanical impedance
piezoelectricity
sensor/actuator
Opis:
This paper is devoted to a new conception of a piezoelectric sensor/actuator designed for the characterization of mechanical properties of the human skin. An theoretical analytical approach is shown In order to establish the link between the electromechanical Mason diagram obtained for a resonance frequency and the contact stiffness calculated with the Hertz’s theory. A finite element method analysis is then presented in order to assess the performance of the chosen topology of piezoelectric sensor/actuator. Finally, the proposed method of impedance characterization is verified experimentally by a prototype of bimorph sensor/actuator.
Niniejszy artykuł przedstawia nową koncepcję piezoelektrycznego sensora/aktuatora przeznaczonego do pomiaru właściwości mechanicznych tkanek miękkich a w szczególności skóry ludzkiej. Wyjaśnione jest analityczne podejście z wykorzystaniem schematu zastępczego Mason’a określającego aktuator w stanie rezonansu oraz opis metody impedancji elektromechanicznej wykorzystanej w systemie pomiarowym. Analiza z użyciem metody elementów skończonych jest przedstawiona w celu oceny wybranej struktury sensora/aktuatora. Zaproponowana metoda pomiaru jest zweryfikowana eksperymentalnie za pomocą prototypu sensora/aktuatora typu bimorph.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 4, 100/2; 83-88
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automatyzacja procesów kalibracji przyrządów pomiarowych i infrastruktura informatyczna w COMW
The automation of calibration process of measuring instruments and IT infrastructure in Primary Standards Laboratory
Autorzy:
Łoś, D.
Rusin, M.
Powiązania:
https://bibliotekanauki.pl/articles/153374.pdf
Data publikacji:
2003
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
automatyczny system kalibracji
technika informatyczna
automated calibration system
IT technology
Opis:
W artykule przedstawiono problematykę budowy i użytkowania systemów automatycznej kalibracji przyrządów pomiarowych oraz wykorzystanie współczesnej techniki informatycznej w centralnym Ośrodku Metrologii Wojskowej.
The issues of construction and using of the automated calibration systems of measuring instruments and applying contemporary IT technology in Primary Standards Laboratory are presented in the article.
Źródło:
Pomiary Automatyka Kontrola; 2003, R. 49, nr 10, 10; 36-39
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stanowisko pomiarowe parametrów procesu automatycznej identyfikacji RFID w warunkach dynamicznej zmiany lokalizacji obiektu w przestrzeni
Laboratory stand for measuring automatic identification process parameters in RFID system under conditions of spatial dynamic changes of object localization
Autorzy:
Jankowski-Mihułowicz, P.
Kalita, W.
Węglarski, M.
Jamróz, T.
Powiązania:
https://bibliotekanauki.pl/articles/156028.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
RFID
identyfikacja wielokrotna
pozycjoner 3D
pomiary dynamiczne
anti-collision identification
3D positioner
dynamic measurement
Opis:
W artykule zaprezentowano konstrukcję i wykorzystanie stanowiska dedykowanego do pomiarów parametrów procesu automatycznej identyfikacji RFID w warunkach dynamicznych. Podstawowym jego elementem jest opracowany pozycjoner 3D, którego konstrukcja zapewnia weryfikację funkcjonowania pojedynczego lub wielokrotnego systemu RFID. Użyteczność stanowiska zobrazowano na przykładzie modelu zmiennej orientacji identyfikatorów, wykorzystywanego podczas wyznaczania obszaru poprawnej pracy indukcyjnie sprzężonego systemu RFID. Szczególną uwagę zwrócono na problem prawidłowego zasilania identyfikatorów pasywnych.
The correct preparation of model for bilateral interaction between objects during their dynamic changes of mutual orientation in space is usually crucial to the accurate operating of a future system in real environment [1, 2]. This type of two-sided relation between elements is also the basis for operation of the Radio Frequency IDentification (RFID) systems for labelling objects (Section 1). The main parameter determining the quality of the interaction between Read/Write Device (RWD) and an identifier (transponder) is described as an interrogation zone [3]. The need for the proposed model (Figs. 1-3 - detailed described in Section 2) verification was the inspiration for developing a special measuring stand. The designed and constructed structure of a two-axle positioner (Fig. 4) is presented in the paper (Section 3). This unit is the main component of the stand (Fig. 5) and allows any change of spatial orientation according to the elements of RFID system. Furthermore, in accordance with the project assumption, an impact of its parts on the magnetic field generated by the RWD antenna is negligible. Its spatial and time parameters are fully controlled by the dedicated software application (Fig. 5a). An integration of the positioner with specialized equipment of RFID technology laboratory in Rzeszów University of Technology allows measuring the impact of dynamicchanges in the position of a few identifiers on the parameters of the anticollision identification process for labelled objects [6].
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 12, 12; 1473-1476
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model nadzoru metrologicznego nad urządzeniami procesowymi do pomiaru THT
A model of metrological supervision of process analyzers for THT measuring
Autorzy:
Huszał, Anna
Powiązania:
https://bibliotekanauki.pl/articles/1834043.pdf
Data publikacji:
2020
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
analizatory procesowe
nawanianie gazu
kontrola procesu nawaniania
process analyzers
gas odorization
odorization process control
Opis:
The increasing demand for process analyzers used in the supervision of the gaseous fuels odorizing process and the related higher and higher users’ requirements in terms of the quality of the results obtained lead to the growing need to verify the correctness of operation thereof and to confirm the reliability of measurement results. At present, however, there are no appropriate legal regulations concerning the control over this type of apparatus, as well as specifying the uncertainty level that the gas odorant concentration should be determined with. The normative regulations existing in this area are not unequivocal and can be interpreted in different ways, which leads to the situation when process equipment for measuring tetrahydrothiophene (THT) concentration in the gas can often lack proper metrological supervision. It is therefore necessary to properly select and verify appropriate methods to control the correctness of the process equipment indications and their implementation into the periodic check program. An extremely desirable method of supervision is to check or calibrate the analyzers in process conditions, without their dismantling for the time of checking. In turn, this entails the necessity to determine the possibility of conducting periodic metrological supervision over the measurement results correctness of THT process analyzers with the use of reference devices. The article presents a comparison of two methods currently used in metrological supervision of process analyzers for measuring the concentration of THT in the natural gas distribution gird. The results of checks of the proper functioning of these devices obtained by means of comparison with the laboratory test and the on-line comparative measurement method were analyzed. The conducted research verified the main sources of errors that have a significant impact on the correctness of results obtained by means of selected test methods. The results obtained showed the existence of a systematic error for the comparison method with a laboratory test. They also demonstrated the possibility of using the on-line comparative measurement method to carry out periodic calibrations or checks of the correct operation of THT analyzers in process conditions.
Źródło:
Nafta-Gaz; 2020, 76, 12; 955--963
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies