The paper discusses results of tests performed by authors, related to the engine bearings
diagnostic using vibration and stator current measurements.
Vibration methods for bearing diagnostics have one disadvantage - they require the
availability of the machine for sensors installation. This is the reason for seeking new
methods based on motor supply current analysis. It can be assumed that each bearing defect
causes radial movement between the rotor and stator of the machine. These changes
generate additional stator current harmonics. The paper contains the description of an
automatic measurement system, developed for the measurement of those harmonics and
processing that data to obtain bearing diagnostic information. System was tested on objects
with intentionally made defects in bearings, results of this test was also shown in the paper.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies