The effect of shell side and coil side volume flow rate on overall
heat transfer coefficient, effectiveness, pressure drop and exergy loss of shell
and helical coil heat exchanger were studied experimentally under steady
state conditions. The working fluid, i.e., water was allowed to flow at three
different flow rates of 1, 2, and 3 l/min on shell side (cold water) and at 1,
1.5, 2, 2.5, and 3 l/min on coil side (hot water) for each shell side flow rate
at the temperatures of 298±0.4 K and 323±0.4 K, respectively. The results
found that the overall heat transfer coefficient increased with increasing
both shell side and coil side volume flow rates. The inner Nusselt number
significantly increased with the coil side Dean number.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies