Transmission of ultrafine particles through separating systems of dust samplers

Tytuł:
Transmission of ultrafine particles through separating systems of dust samplers
Autorzy:
Skubacz, K.
Powiązania:
https://bibliotekanauki.pl/articles/92165.pdf
Data publikacji:
2018
Wydawca:
Główny Instytut Górnictwa
Tematy:
underground mine
short-lived radon progeny
ultrafine particles
cyclone
deposition of particles
górnictwo podziemne
krótkożyciowe produkty rozpadu radonu
cząstki ultradrobne
cyklon
depozycja cząstek
Źródło:
Journal of Sustainable Mining; 2018, 17, 2; 48-55
2300-1364
2300-3960
Język:
angielski
Prawa:
CC BY-NC-ND: Creative Commons Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0
Dostawca treści:
Biblioteka Nauki
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
In underground mines there is a radiation hazard associated with natural radioactive nuclides. The main sources of radiation exposure in Polish mines are short-lived radon decay products, radioactive mine water containing radium and the sediments precipitated from these waters. For miners, the most common hazard is usually the short-lived radon decay products. Aspirators, equipped with separation systems, are mostly used in order to control this hazard. Inside these aspirators there are meters which measure the radiation emitted by radioactive aerosols collected on the filter. The purpose of these systems is to remove particles from the air stream that do not form the respirable fraction. At the same time, however, a deposition of small-size aerosols takes place in them because of the high values of their corresponding diffusion coefficients. This excludes the possibility of their proper detection by radiation meters. In this paper, the transmission of particles up to 100 nm in size by the separating systems is evaluated. The evaluated transmission ranged from about 60% for sizes of 7 nm, reaching up to 95% at the boundary values of the tested range. The influence of the particle distribution of the aerosols on the radiation calibration coefficients was also investigated in a radon chamber, through their exposure to conditions where the air contained low aerosol concentrations of about 4.0×108 particles/m3 and also when it was nearly 100-times higher. In the first case, the measured sensitivity of the meters was about 20-30% lower, which was probably due to a higher number of small aerosols and, as a result, particle transmission decreased. However, at higher aerosol concentrations, the sensitivity of the meters remained practically the same, regardless of whether the air reached the filters by the separation systems or if they were omitted.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies