The authors analysed a proportional valve with electrical position feedback for its failure behaviour. Several failures were introduced into the feedback loop, especially into the 2 solenoids and the inductive position transducer. The behaviour of the valve for square and ramp reference signals was recorded and systematically analysed. It was shown that failures could be detected by monitoring the residual signal from the equipment under control or the residual signal from the sensor. It was possible to achieve the safe position within twice the normal response time of the valve by switching off the current of both solenoids. The application of these results for a new generation of safe proportional valves is discussed. The use of the results of these investigations obviates the need for redundancy of the electrical position monitoring arrangement in a safe proportional valve.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies