Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF TIZANIDINE HCL AND MELOXICAM IN BILAYER MUCOADHESIVE BUCCAL FILMS

Tytuł:
DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF TIZANIDINE HCL AND MELOXICAM IN BILAYER MUCOADHESIVE BUCCAL FILMS
Autorzy:
Zaman, Muhammad
hanif, Muhammad
Murtaza, Hassan
Powiązania:
https://bibliotekanauki.pl/articles/895591.pdf
Data publikacji:
2018-08-31
Wydawca:
Polskie Towarzystwo Farmaceutyczne
Tematy:
RP-HPLC
method development
simultaneous determination
Recoveries
Źródło:
Acta Poloniae Pharmaceutica - Drug Research; 2018, 75, 4; 851-859
0001-6837
2353-5288
Język:
angielski
Prawa:
CC BY-NC: Creative Commons Uznanie autorstwa - Użycie niekomercyjne 4.0
Dostawca treści:
Biblioteka Nauki
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
Tizanidine HCl (TZN HCl) is a muscle relaxant and Meloxicam (MLX) is a non-steroidal anti-inflammatory drug used for various pain disorders. They are extensively used as combination therapy in various pain disorder and the need is to develop a suitable method for their simultaneous determination loaded in a single dosage form. Objective of the study was to develop a simple, specific, and accurate reverse phase high performance liquid chromatographic (RP-HPLC) method was developed for the simultaneous determination of TZN HCl and MLX. A kromasil C18 (250×4.60 mm dimensions, 5 μm particle size) column with mobile phase consisting of methanol:water (80:20) was used at isocratic mode. pH of the mobile phase was adjusted to 3.0 by using ortho phosphoric acid and 228nm was taken as lambda max for the detection of drugs. Flow rate was adjusted to 0.8ml/min at ambient temperature with average operating pressure of 140 bar. The retention time of TZN HCl was 2.613 min and of MLX was 6.992 min with resolution of 3.23 and both drugs showed satisfactory linearity in the range of 5-50 μg/mL with correlation coefficient (R2) 0.09997 and 0.9993 respectively. The method was validated as per ICH guidelines and found to be précised with less than 2% relative standard deviation (%RSD). % Recoveries of TZN HCl and MLX were in the range of 99.01% to 100.47% and 98.18% to 100.88% respectively. From the result, it was concluded that the method is suitable for the simultaneous quantification of TZN HCl and MLX.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies