Numerous firms dealing with widely understood natural environment protection
offer various solutions for domestic sewage treatment plants. While
choosing the suitable variant of such installation, an investor is driven in the first
place by economic factors, easy operation and high operational reliability.
The article presents and assesses four domestic sewage treatment systems
working on the basis of activated sludge technology, biofilter and combinations of
these two methods, selected in view of the results they achieved.
Because of the specific character of sewage produced in the areas with dispersed
buildings, sewage treatment plant installations must prove highly reliable
under variable operating conditions, they should be cheap to construct and utilize
and not require complicated service. It seems that Sequencing Batch Rectors
(SBR) treatment plants meet these requirements, as well as combined installations
which join a classic activated sludge method and submerged or mobile biofilter
systems. In case of SBR reactors, the whole process of sewage treatment occurs in
a single tank where individual phases of the working cycle are controlled by computer.
Regulation of supplied air quantity allows to modify the bioreactor work cycle
in the way making possible additional reduction of biogenic compounds from
sewage.
Technical solutions which combine activated sludge and biofilter methods
are becoming increasingly more popular. Such treatment plants incorporate advantages
of both methods. They are especially recommended in holiday resorts
where considerable irregularity of sewage inflow and storage occurs. During the
period of low hydraulic loading or when no sewage outflow is registered, biocenosis
in the form of activated sludge will not die back fast because the substrate necessary
for microorganism development will be obtained from forming biofilm
covering the biofilter. The examples of domestic sewage treatments plants presented in the article
are characterized by high reduction of organic and biogenic pollutants as has been
revealed by the tests conducted in the operated installations. Because of that they
may be particularly recommended in the areas susceptible to water eutrophication.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies