The influence of ODM technique on the radiation dose received by patients during head CT scan

Tytuł:
The influence of ODM technique on the radiation dose received by patients during head CT scan
Autorzy:
Sobczyk, Joanna
Pusz-Sapa, Aleksandra
Wojtasik, Aneta
Gaweł, Greta
Truszkiewicz, Adrian
Guz, Wiesław
Powiązania:
https://bibliotekanauki.pl/articles/454704.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Rzeszowski. Wydawnictwo Uniwersytetu Rzeszowskiego
Tematy:
organ dose modulation
computed tomography
protection against ionizing radiation
Źródło:
European Journal of Clinical and Experimental Medicine; 2018, 3; 198-203
2544-2406
2544-1361
Język:
angielski
Prawa:
Wszystkie prawa zastrzeżone. Swoboda użytkownika ograniczona do ustawowego zakresu dozwolonego użytku
Dostawca treści:
Biblioteka Nauki
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
Introduction. Computed tomography (CT) is inexpensive radiological examination of high diagnostic effectiveness. However, common use of CT tests has led to increased exposure to ionizing radiation in the population. Aim. To assess the effect of organ dose modulation (ODM) technique on the radiation dose received by patients during head CT scan. Material and methods. A retrospective analysis of 120 tests in two groups of patients who had CT scans without and with ODM. Every group consisted of 60 people (30 women and 30 men in each). The ability to perform tests in two algorithms (without and with ODM) resulted from the fact that after installing the apparatus, tests were carried out using standard technique, and only then the ODM function was launched. Results. We found that during examinations with ODM, patients received a reduced dose of ionizing radiation. The mean DLP value with ODM is 9.4% lower than the mean DLP value without ODM by comparing the tests with and without contrasting agent. The mean DLP value obtained in men using ODM was 11.9% lower than the mean dose without ODM, and in women this difference was 6.6%. Conclusion. The mean DLP value received by men with ODM was by 11.9% lower than the mean dose without ODM, and in women this difference was 6.6%. Patients receive a lower dose both in tests with and without a contrasting agent compared to the tests where ODM was not used. A statistical significance of the obtained results was found.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies