In this paper the experimental studies of the screen working in the parametric resonance condition are discussed. The investigations
are conducted for laboratory parametric resonance screen. The measuring test is performed for four cases of tension force values.
The full sheet metal instead of the sieve is used. For each considered case the natural frequency of the plate and the parameter modulation
frequency are determined.The achieved results are presented and discussed. It is shown that the highest sieve plate amplitude is obtained
when the parameter modulation frequency is two times larger than natural frequency of the sieve plate. This parametric resonance
vibration was observed only for tension force equal to 4000 N because of the rotational speed limits of electrical vibratos.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies