The paper presents a tentative solution to the problem
of olfaction-based mobile robot navigation in the chemical
plume. This type of navigation requires fast and reliable
detection of small gradient of gas concentration in
3D space. The special sensor system designed to detect
odour plume with significantly reduced inertia named
”chemical scanner” was proposed [5]. A special aƩention
has been given to evaluate sensing system performance
in stable and repeatable conditions. The ability to detect
small gradient of gas concentration was examined on a
special test bench. The real spatial distribution of tested
gas in the air was estimated using CFD simulation. The results
proved that the real-time detection of small (a few
percent of measured value) difference in gas concentration on very short distance (a several centimetres range)
is possible. The next stage of research will examine of the
developed sensor system on the mobile plaƞorm for its
navigation.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies