The paper presents the phenomenon of thermal bridges caused by air infiltration. The problem of poor air tightness is very common in the former Eastern Bloc countries. The laboratory investigation was set up to recognize the impact of air infiltration on heat flux through the building envelope. The frame wall model insulated with loose mineral wool was investigated in non-isothermal climatic chamber. As a result of cold air infiltration, surfaces of gaps and areas adjacent to them were cooled, which is illustrated on temperature profiles. The forty minutes infiltration of 0o C air resulted as a 3.5o C cooling of gap area. The thermal simulation in Delphin confirmed the laboratory results.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies