The baffle factor is a parameter widely used to describe flow system characteristics. This indicator
is very important in designing disinfection devices. For example, it is used to convert the
plug flowtime to the actual fluid residence time in the flowsystem of interest. Its accurate determination
is a complex problem requiring tracer experiments or computational fluid dynamics
simulations. Therefore, in practice, it is often taken from tables provided in the literature. The
literature sources, however, state that the baffle factor for a flow in a straight pipe is equal
to unity, which implies the identity between the pipe flow model and the plug flow model.
This assumption is doubtful. The aim of the present work is to verify the baffle factor values
assumed for the pipe flow. The merit of this study is the analytical derivation of the expression
describing the baffle factor value with respect to flow characteristics. To this purpose, the
analytical solution of a one-dimensional advection-diffusion equation with a Heaviside initial
condition was used. It was demonstrated that the aforementioned assumption is wrong, as the
baffle factor for a straight pipe is significantly less than unity.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies