The paper describes tests intended to examine the occurrence of natural convection within the space occupied by 40x20 mm rectangular steel sections. Within these tests the bed of four layers of section was heated by the electric palate heater. Depending on the manner in which the heater was positioned, the tests were divided into two series. In the case of heating from above, the heat flowing through the bed is transferred only by conduction and radiation. When heating the bed from below, in addition to conduction and radiation, also a convective heat transfer will occur. Should this be the case, it will result in the intensification of the heat exchange. The results of measurements carried out have not demonstrated that the occurrence of any possible natural convection would influence the development of a temperature field in this type of charge.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies
Informacja
SZANOWNI CZYTELNICY!
UPRZEJMIE INFORMUJEMY, ŻE BIBLIOTEKA FUNKCJONUJE W NASTĘPUJĄCYCH GODZINACH:
Wypożyczalnia i Czytelnia Główna: poniedziałek – piątek od 9.00 do 19.00