Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

The combined effect of fractional filter and Smith Predictor for enhanced closed-loop performanceof integer order time-delay systems: some investigations

Tytuł:
The combined effect of fractional filter and Smith Predictor for enhanced closed-loop performanceof integer order time-delay systems: some investigations
Autorzy:
Nagarsheth, Shaival Hemant
Sharma, Shambhu Nath
Powiązania:
https://bibliotekanauki.pl/articles/229571.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
generalized fractional controller
Smith predictor
time delay system
generalized inverse
Bode’s ideal transfer function
Źródło:
Archives of Control Sciences; 2020, 30, 1; 47-76
1230-2384
Język:
angielski
Prawa:
CC BY-NC-ND: Creative Commons Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 PL
Dostawca treści:
Biblioteka Nauki
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
This paper proposes a generalized fractional controller for integer order systems with time delay. The fractional controller structure is so adopted to have a combined effect of fractional filter and Smith predictor. Interestingly, the resulting novel controller can be decomposed into fractional filter cascaded with an integer order PID controller. The method is applied to two practical examples i.e. liquid level system and Shell control fractionator system. The closed-loop responses resulting from the proposed method are compared with that of the available methods in the literature. For quantitative evaluations of the proposed method, Integral Absolute Error (IAE) and Integral Square Control Input (ISCI) performance criteria are employed. The proposed method effectively enhances the closed-loop response by improving the IAE values, reducing the control effort inputs to achieve the desired output. The disturbance rejection and robustness tests are also carried out. The robustness test reveals a significant improvement in the maximum absolute sensitivity measure. That is displayed in numerical simulations of the paper.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies